Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air Conditioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Heat Pipes

Phoenix Refrigeration Systems, Inc.'s heat pipe addition to the Phoenix 2000, a supermarket rooftop refrigeration/air conditioning system, resulted from the company's participation in a field test of heat pipes. Originally developed by NASA to control temperatures in space electronic systems, the heat pipe is a simple, effective, heat transfer system. It has been used successfully in candy storage facilities where it has provided significant energy savings. Additional data is expected to fully quantify the impact of the heat pipes on supermarket air conditioning systems.

Source record↗

Adaptive-wall wind-tunnel research at NASA-Ames Research Center

Adaptive wall wind tunnel research is summarized. Small scale two and three dimensional wind tunnel experiments and numerical experiments with a three dimensional adaptive wall simulator are included. A NACA 0012 airfoil was tested in a 25 by 13 cm slotted wall test section. Airflow through the test section walls was controlled by adjusting the pressures in segmented plenums. Interference free conditions were successfully attained in subsonic and transonic flows. For the three dimensional experiment, the 25 by 13 cm wind tunnel was modified to permit cross stream wall adjustments. The test model was a semispan wing mounted to one sidewall. Wall interference was substantially reduced at several angles of attack at Mach 0.60. A wing on wall configuration was also modeled in the numerical experiments. These flow simulations showed that free air conditions can be approximated by adjusting boundary conditions at only the floor and ceiling of the test section. No sidewall control was necessary. Typical results from these experiments are discussed.

Schairer, E. T.↗

Potential of a Plant Gas Exchange Mechanistic Model to Predict Plant Transpiration in Veggie on ISS

Plants are an essential part of long-duration space travel, as they enable food production and contribute to air revitalization through photosynthesis, and water recycling through transpiration. Understanding their growth mechanisms is essential to use them to sustain human life in space. In particular, gas exchange – e.g., CO2 absorption and water transpiration – are modified in microgravity because of the lack of buoyancy-driven convection, and in the long run, this could result in impaired plant growth. Water absorbed by the plants mainly depends on their size and on environmental conditions (air temperature, humidity and ventilation), but in microgravity watering plants is a delicate operation – too much water results in flooded roots and too little water leads in a few hours to wilted plants. This is regularly experienced in the Veggie system on ISS, which enables small-scale food production in microgravity since 2014. This presentation explores how a mechanistic model of plant gas exchange can help predict plant transpiration in Veggie and thus better predict daily watering. For each plant, inputs on canopy leaf area (acquired with daily photos), air temperature and relative humidity in the plant compartment, as well as airspeed at the top of its canopy enable accurate predictions of transpiration in microgravity. This brings a better understanding of water movement through the plant in microgravity in relation to ventilation and plant size and would result in easier management of plant watering in Veggie. Ultimately, this work could be applied to any space crop production in microgravity and be used for water management and yield predictions. This work was funded by NASA Space Biology through NASA postdoctoral program / USRA.

Lucie Poulet↗

Potential of a Plant Gas Exchange Mechanistic Model to Predict Plant Transpiration in Veggie on ISS

Plants are an essential part of long-duration space travel, as they enable food production and contribute to air revitalization through photosynthesis, and water recycling through transpiration. Understanding their growth mechanisms is essential to use them to sustain human life in space. In particular, gas exchange – e.g., CO2 absorption and water transpiration – are modified in microgravity because of the lack of buoyancy-driven convection, and in the long run, this could result in impaired plant growth. Water absorbed by the plants mainly depends on their size and on environmental conditions (air temperature, humidity and ventilation), but in microgravity watering plants is a delicate operation – too much water results in flooded roots and too little water leads in a few hours to wilted plants. This is regularly experienced in the Veggie system on ISS, which enables small-scale food production in microgravity since 2014. This presentation explores how a mechanistic model of plant gas exchange can help predict plant transpiration in Veggie and thus better predict daily watering. For each plant, inputs on canopy leaf area (acquired with daily photos), air temperature and relative humidity in the plant compartment, as well as airspeed at the top of its canopy enable accurate predictions of transpiration in microgravity. This brings a better understanding of water movement through the plant in microgravity in relation to ventilation and plant size and would result in easier management of plant watering in Veggie. Ultimately, this work could be applied to any space crop production in microgravity and be used for water management and yield predictions. This work was funded by NASA Space Biology through NASA postdoctoral program / USRA.

Lucie Poulet↗

Gateway Integrated Environmental Control and Life Support System (ECLSS) Overview and Status

The Gateway comprised of modules provided by commercial and international partners will be a lunar orbiting platform that is a critical element in the Moon to Mars architecture. Of the 4 modules that comprise the Gateway, the core Environmental Control and Life Support System (ECLSS) is provided by the Habitation and Logistics Outpost (HALO) module provided by NASA, and the International Habitat (I-Hab) provided by the European Space Agency (ESA) with the ECLSS provided by the Japanese Space Agency (JAXA). These modules work together to provide pressure control, air revitalization, and air conditioning capabilities for the Gateway integrated habitable volumes and attached visiting vehicles during open hatch crewed operations. Individually, they maintain the internal atmosphere during the long periods of dormancy between crewed operations to support payload operations and ensure a safe environment when the crew returns. Additionally, NASA bolsters crew survivability by providing government furnished equipment (GFE) to support crew survival in the face of catastrophic hazards (such as fire or a cabin air leak) until the Gateway stack reaches a point in the orbit where crew can safely abort on Orion. This paper explains the key driving requirements, architecture, and development status of the Gateway ECLSS.

Gateway↗

Effects of Ambient Conditions on Helicopter Harmonic Noise Radiation: Theory and Experiment

The effects of ambient atmospheric conditions, air temperature, and density on rotor harmonic noise radiation are characterized using theoretical models and experimental measurements of helicopter noise collected at three different test sites at elevations ranging from sea level to 7000 ft above sea level. Significant changes in the thickness, loading, and blade–vortex interaction noise levels and radiation directions are observed across the different test sites for an AS350 helicopter flying at the same indicated airspeed and gross weight. However, the radiated noise is shown to scale with ambient pressure when the flight condition of the helicopter is defined in nondimensional terms. Although the effective tip Mach number is identified as the primary governing parameter for thickness noise, the nondimensional weight coefficient also impacts lower harmonic loading noise levels, which contribute strongly to low-frequency harmonic noise radiation both in and out of the plane of the horizon. Strategies for maintaining the same nondimensional rotor operating condition under different ambient conditions are developed using an analytical model of single main rotor helicopter trim and confirmed using a CAMRAD II model of the AS350 helicopter. The ability of the Fundamental Rotorcraft Acoustics Modeling from Experiments (FRAME) technique to generalize noise measurements made under one set of ambient conditions to make accurate noise predictions under other ambient conditions is also validated.

rotorcraft↗

Simultaneous measurements of ozone outside and inside cabins of two B-747 airliners and a Gates Learjet business jet

The average amount of ozone measured in the cabins of two B-747 airliners varied from 40 percent to 80 percent of the atmospheric concentrations without special ozone destruction systems. A charcoal filter in the cabin air inlet system of one B-747 reduced the ozone to about 5 percent of the atmospheric concentration. A Learjet 23 was also instrumented with monitors to measure simultaneously the atmospheric and ozone concentrations. Results indicate that a significant portion of the atmospheric ozone is not destroyed in the pressurization system and remains in the aircraft cabin of the Learjet. For the two cabin configurations tested, the ozone retentions were 63 and 41 percent of the atmospheric ozone concentrations. Ozone concentrations measured in the cabin near the conditioned-air outlets were reduced only slightly from atmospheric ozone concentrations. It is concluded that a constant difference between ozone concentrations inside and outside the cabin does not exist.

Perkins, P. J.↗

Using spacecraft trace contaminant control systems to cure sick building syndrome

Many residential and commercial buildings with centralized, recirculating, heating ventilation and air conditioning systems suffer from 'Sick Building Syndrome.' Ventilation rates are reduced to save energy costs, synthetic building materials off-gas contaminants, and unsafe levels of volatile organic compounds (VOC's) accumulate. These unsafe levels of contaminants can cause irritation of eyes and throat, fatigue and dizziness to building occupants. Increased ventilation, the primary method of treating Sick Building Syndrome is expensive (due to increased energy costs) and recently, the effectiveness of increased ventilation has been questioned. On spacecraft venting is not allowed, so the primary methods of air quality control are; source control, active filtering, and destruction of VOC's. Four non-venting contaminant removal technologies; strict material selection to provide source control, ambient temperature catalytic oxidation, photocatalytic oxidation, and uptake by higher plants, may have potential application for indoor air quality control.

Graf, John C.↗

Octafluoropropane Concentration Dynamics on Board the International Space Station

Since activating the International Space Station s (IS9 Service Module in November 2000, archival air quality samples have shown highly variable concentrations of octafluoropropane in the cabin. This variability has been directly linked to leakage from air conditioning systems on board the Service Module, Zvezda. While octafluoro- propane is not highly toxic, it presents a significant chal- lenge to the trace contaminant control systems. A discussion of octafluoropropane concentration dynamics is presented and the ability of on board trace contami- nant control systems to effectively remove octafluoropro- pane from the cabin atmosphere is assessed. Consideration is given to operational and logistics issues that may arise from octafluoropropane and other halo- carbon challenges to the contamination control systems as well as the potential for effecting cabin air quality.

Perry, J. L.↗

The Effects of Ambient Conditions on Helicopter Harmonic Noise Radiation: Theory and Experiment

The effects of ambient atmospheric conditions, air temperature and density, on rotor harmonic noise radiation are characterized using theoretical models and experimental measurements of helicopter noise collected at three different test sites at elevations ranging from sea level to 7000 ft above sea level. Significant changes in the thickness, loading, and blade-vortex interaction noise levels and radiation directions are observed across the different test sites for an AS350 helicopter flying at the same indicated airspeed and gross weight. However, the radiated noise is shown to scale with ambient pressure when the flight condition of the helicopter is defined in nondimensional terms. Although the effective tip Mach number is identified as the primary governing parameter for thickness noise, the nondimensional weight coefficient also impacts lower harmonic loading noise levels, which contribute strongly to low frequency harmonic noise radiation both in and out of the plane of the horizon. Strategies for maintaining the same nondimensional rotor operating condition under different ambient conditions are developed using an analytical model of single main rotor helicopter trim and confirmed using a CAMRAD II model of the AS350 helicopter. The ability of the Fundamental Rotorcraft Acoustics Modeling from Experiments (FRAME) technique to generalize noise measurements made under one set of ambient conditions to make accurate noise predictions under other ambient conditions is also validated.

Greenwood, Eric↗

The Effects of Engine Speed and Mixture Temperature on the Knocking Characteristics of Several Fuels

Six 100-octane and two 87-octane aviation engine fuels were tested in a modified C.F.R. variable-compression engine at 1,500, 2,000 and 2,500 rpm. The mixture temperature was raised from 50 to 300 F in approximately 50 degree steps and, at each temperature, the compression ratio was adjusted to give incipient knock as shown by a cathode ray indicator. The results are presented in tabular form. The results are analyzed on the assumption that the conditions which determine whether a given fuel will knock are the maximum values of density and temperature reached by the burning gases. A maximum permissible density factor, proportional to the maximum density of the burning gases just prior to incipient knock, and the temperature of the burning gases at that time were computed for each of the test conditions. Values of the density factors were plotted against the corresponding end-gas temperatures for the three engine speeds and also against engine speed for several and end-gas temperatures. The maximum permissible density factor varied only slightly with engine speed but decreased rapidly with an increase in the end-gas temperature. The effect of changing the mixture temperature was different for fuels of different types. The results emphasize the desirability of determining the anti knock values of fuels over a wide range of engine and intake-air conditions rather that at a single set of conditions.

Lee, Dana W↗

Development of an in-line filter to prevent intrusion of NO2 toxic vapors into A/C systems

The hypergolic propellant nitrogen tetroxide (N2O4 or NTO) is routinely used in spacecraft launched at Kennedy Space Center (KSC) and Cape Canaveral Air Station (CCAS). In the case of a catastrophic failure of the spacecraft, there would be a release of the unspent propellant in the form of a toxic cloud. Inhalation of this material at downwind concentrations which may be as high as 20 parts per million (ppm) for 30 minutes in duration, may produce irritation to the eyes, nose and respiratory tract. Studies at both KSC and CCAS have shown that the indoor concentrations of N2O4 during a toxic release may range from 1 to 15 ppm and depend on the air change rate (ACR) for a particular building and whether or not the air conditioning (A/C) system has been shut down or left in an operating mode. This project was initiated in order to assess how current A/C systems could be easily modified to prevent personnel from being exposed to toxic vapors. A sample system has been constructed to test the ability of several types of filter material to capture the N2O4 vapors prior to their infiltration into the A/C system. Test results will be presented which compare the efficiencies of standard A/C filters, water wash systems, and chemically impregnated filter material in taking toxic vapors out of the incoming air stream.

Meneghelli, Barry↗

Development of a solar-powered residential air conditioner: Economic analysis

The results of investigations aimed at the development of cost models to be used in the economic assessment of Rankine-powered air conditioning systems for residential application are summarized. The rationale used in the development of the cost model was to: (1) collect cost data on complete systems and on the major equipment used in these systems; (2) reduce these data and establish relationships between cost and other engineering parameters such as weight, size, power level, etc; and (3) derive simple correlations from which cost-to-the-user can be calculated from performance requirements. The equipment considered in the survey included heat exchangers, fans, motors, and turbocompressors. This kind of hardware represents more than 2/3 of the total cost of conventional air conditioners.

Source record↗

Integrated Orbiter/International Space Station Air Quality Analysis for Post-Mission 2A.1 Risk Mitigation

Even under the assumption that all Orbiter and ISS elements would be operating as designed, condensation control and crewmember comfort were paramount issues preceding each of the ISS Missions 2A and 2A.1. However, crewmember discomfort during Mission 2A.1, in addition to evidence provided by flight data and observations, suggested that countermeasures would be necessary for future flights where the Orbiter provides primary control. A review of Space Shuttle Program (SSP) and International Space Station Program (ISSP) assumptions and analytical methods that describe ECLS transport phenomena was accomplished in order to ensure the veracity of future analyses. Subsequently, various analyses and interpretations of Mission 2A.1 flight data provided the necessary information to help understand the probable causes of the flight environment. With cooperation between the SSP and ISSP, countermeasures were devised for Mission 2A.2 that would likely improve the delivery of conditioned air by the Orbiter to the ISS as well as within the ISS elements.

RISK MANAGEMENT↗

Aeroacoustic Computations of a Generic Low Boom Concept in Landing Configuration: Part 1 - Aerodynamic Simulations

Computational results are presented for a 15%-scale, full-span, generic low-boom concept aircraft model simulated as installed in the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel and in free-air conditions. The simulations were conducted with the lattice Boltzmann solver PowerFLOW® to capture the time-accurate characteristics of the flow. The aerodynamic behavior of the aircraft was investigated with various combinations of flap and landing gear deployments. To replicate the flow speed used during tests of the model, a Mach number of approximately 0.20 was chosen while varying the angle of attack through a limited range. Analyses were performed on local flow quantities, global forces, as well as flow distributions between configurations. Aerodynamic quantities were shown to be sensitive to mesh resolution levels, especially with flap and landing gear systems retracted. When comparing wind tunnel to free-air simulations, the aerodynamic quantities sampled were found to be in good agreement, suggesting that tunnel blockage and model support effects did not adversely impact the aerodynamic behavior of the model during the wind tunnel test. The results of this study improve our understanding of the highly complex, vortical flow generated by configurations with swept, low aspect-ratio wings at speeds encountered during landing operations.

low boom↗

Space station common module thermal management: Design and construction of a test bed

In this project, a thermal test bed was designed, simulated, and planned for construction. The thermal system features interior and exterior thermal loads and interfacing with the central-radiator thermal bus. Components of the test bed include body mounted radiator loop with interface heat exchangers (600 Btu/hr); an internal loop with cabin air-conditioning and cold plates (3400 Btu/hr); interface heat exchangers to the central bus (13,000 Btu/hr); and provisions for new technology including advanced radiators, thermal storage, and refrigeration. The apparatus will be mounted in a chamber, heated with lamps, and tested in a vacuum chamber with LN2-cooled walls. Simulation of the test bed was accomplished using a DEC PRO 350 computer and the software package TK! olver. Key input variables were absorbed solar radiation and cold plate loads. The results indicate temperatures on the two loops will be nominal when the radiation and cold plate loads are in the range of 25% to 75% of peak loads. If all loads fall to zero, except the cabin air system which was fixed, the radiator fluid will drop below -100 F and may cause excessive pressure drop. If all loads reach 100%, the cabin air temperature could rise to 96 F.

Barile, R. G.↗

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

Building Heating, Ventilation and Air Conditioning (HVAC) is a major contributor to urban energy use. In single story buildings with large surface area such as warehouses most of the heat enters through the roof. A rooftop modification that has not been examined experimentally is solar photovoltaic (PV) arrays. In California alone, several GW in residential and commercial rooftop PV are approved or in the planning stages. With the PV solar conversion efficiency ranging from 5-20% and a typical installed PV solar reflectance of 16-27%, 53-79% of the solar energy heats the panel. Most of this heat is then either transferred to the atmosphere or the building underneath. Consequently solar PV has indirect effects on roof heat transfer. The effect of rooftop PV systems on the building roof and indoor energy balance as well as their economic impacts on building HVAC costs have not been investigated. Roof calculator models currently do not account for rooftop modifications such as PV arrays. In this study, we report extensive measurements of a building containing a flush mount and a tilted solar PV array as well as exposed reference roof. Exterior air and surface temperature, wind speed, and solar radiation were measured and thermal infrared (TIR) images of the interior ceiling were taken. We found that in daytime the ceiling surface temperature under the PV arrays was significantly cooler than under the exposed roof. The maximum difference of 2.5 C was observed at around 1800h, close to typical time of peak energy demand. Conversely at night, the ceiling temperature under the PV arrays was warmer, especially for the array mounted flat onto the roof. A one dimensional conductive heat flux model was used to calculate the temperature profile through the roof. The heat flux into the bottom layer was used as an estimate of the heat flux into the building. The mean daytime heat flux (1200-2000 PST) under the exposed roof in the model was 14.0 Watts per square meter larger than under the tilted PV array. The maximum downward heat flux was 18.7 Watts per square meters for the exposed roof and 7.0 Watts per square meters under the tilted PV array, a 63% reduction due to the PV array. This study is unique as the impact of tilted and flush PV arrays could be compared against a typical exposed roof at the same roof for a commercial uninhabited building with exposed ceiling and consisting only of the building envelope. Our results indicate a more comfortable indoor environment in PV covered buildings without HVAC both in hotter and cooler seasons.

Dominguez, A.↗

Building Climate Resilience at NASA Ames

NASA Ames Research Center, located at the southern end of the San Francisco Bay (SFB) estuary has identified three primary vulnerabilities to changes in climate. The Ames Climate Adaptation Science Investigator (CASI) workgroup has studied each of these challenges to operations and the potential exposure of infrastructure and employees to an increased frequency of hazards. Sea level rise inundation scenarios for the SFB Area generally refer to projected scenarios in mean sea level rather than changes in extreme tides that could occur during future storm conditions. In the Summer of 2014, high resolution 3-D mapping of the low lying portion of Ames was performed. Those data are integrated with improved sea level inundation scenarios to identify the buildings, basements and drainage systems potentially affected. We will also identify the impacts of sea level and storm surge effects on transportation to and from the Center. This information will help Center Management develop future Master Plans. Climate change will also lead to changes in temperature, storm frequency and intensity. These changes have potential impacts on localized floods and ecosystems, as well as on electricity and water availability. Over the coming decades, these changes are going to be imposed on top of ongoing land use and land cover changes, especially those deriving from continued urbanization and increase in impervious surface areas. These coupled changes have the potential to create a series of cascading impacts on ecosystems, including changes in primary productivity and disturbance of hydrological properties and increased flood risk.The majority of the electricity used at Ames is supplied by hydroelectric dams, which will be influenced by reductions in precipitation or changes in the timing or phase of precipitation which reduces snow pack. Coupled with increased demand for summertime air conditioning and other cooling needs, NASA Ames is at risk for electricity shortfalls. To assess the anticipated energy usage as climate changes, the Ames CASI team is collecting historical energy usage data from Ames facilities, historical weather data, and projected future weather parameters from the CASI Climate subgroup. This data will be incorporated into the RETScreen model to predict how energy usage at Ames will change over the coming century.

climate↗