Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air mass”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Thermal Analysis Evaluations Using the Dry Cask Simulator

Different thermal analysis models were developed to simulate the dry cask simulator (DCS). The DCS is an experiment designed to simulate dry storage of a single boiling water reactor fuel assembly under a variety of heat loads and internal pressures. The DCS was set up and tested in both a vertical and horizontal configuration to determine cladding temperatures in vertical and horizontal dry cask storage systems. The models included a detailed STAR-CCM+ model with the fuel assembly geometry explicitly modeled, a porous STAR-CCM+ model with the fuel assembly geometry modeled as porous media region with calculated effective properties, and a COBRA-SFS model. COBRA-SFS is a thermal-hydraulic code developed for steady-state and transient analysis of multi assembly spent-fuel storage and transportation systems. STAR-CCM+ is a commercial computation fluid dynamics (CFD) code. Both a detailed and porous STARCCM+ model were developed to look at the effective thermal conductivity (keff) approach to modeling a fuel assembly. A keff fuel model is typically model in CFD thermal analyses due to its significantly lower computational costs. The models were run for a combination of low and high canister pressures (100 kPa and 800 kPa) and low and high internal heat loads (0.5 kW and 5 kW). Results from all three models were compared against experimental data taken from the DCS for the peak cladding temperature (PCT) and inlet air mass flow.

Suffield, Sarah R.↗

Validation of an Erythema-Weighted UV Model Using Broadband Solar Irradiance Measurements From Eleven U.S. Sites: Preprint

Erythema-weighted UV solar irradiance (UV-E) has a potential impact on human health if the recommended maximum exposure times are exceeded. In spite of this, it is not measured at most sites that measure Global Horizontal Irradiance (GHI). However, since UV-E is highly correlated with GHI and total ozone content it can be estimated from this information with sufficient accuracy to assisst in public health recommendations. The Power Model (PM) provides a simple method to estimate the erythema-weighted UV irradiance (UV-E) from measured GHI, total ozone column and air mass. In this work, the performance of the PM method is assessed using high-quality data from 11 sites in the continental U.S. (part of SURFRAD and SOLRAD networks) and total ozone estimates publicly available from the MERRA-2 re-analysis database. A three year period (2021- 2023) at 1-minute frequency is considered. The results (for time aggregations of 5 and 60 minutes) show a high Pearson's correlations (> 0.99), consistently positive mean bias deviations (below 13%) and dispersions in the 8-19% range at all sites. Relative values are expressed in terms of the corresponding measurement mean. The performance indicators remain consistent across time resolutions (5 or 60 minutes), suggesting that the model's performance is robust and not significantly affected by short-term variability (which is captured by GHI). Spatial patterns reveal higher biases and RMSD in northern and eastern locations. These values represent a significant improvement over widely used satellite-based global UV-E estimates and open the possibility of using the PM with satellite-based GHI estimates for operational UV-E mapping over the contiguous U.S. territory.

14 SOLAR ENERGY↗

Resolving Graphite‐Electrolyte Interphase of Lithium‐Ion Batteries using Air‐Tight Ambient Mass Spectrometry

Abstract The formation of a stable solid electrolyte interphase (SEI) at graphite electrode is necessary for lithium‐ion batteries (LIB) to prevent excessive degradation of electrolytes. Until now, the exact organic composition of SEI has not been decisively determined with lithium ethylene mono‐carbonate (LEMC) being one of the debated components. An air‐tight ambient mass spectrometry (MS) platform is developed to directly characterize the air‐sensitive organic components present in SEI. Ionization occurs via a solvent‐free field‐induced process at atmospheric pressure. Our experimental data, based on tandem MS analysis, revealed LEMC to be the major organic component in SEI. This result resolves a long‐standing mystery surrounding the composition of native SEI in LIB, where no trace of the other debated compound, lithium ethylene dicarbonate, was detected. The energetics of fragmentation of LEMC and the corresponding stabilities of various ionic species detected during the air‐tight ambient MS analysis were calculated using density functional theory (DFT). Our findings confirmed favorable protonation energies and suggested the molecular structures for many of the detected species. Solvent (i. e., ethylene carbonate)‐induced stabilization effects observed during the ionization process were also confirmed by DFT. The reported study encourages the routine use of ambient mass spectrometry to characterize both anodic and cathodic electrodes of all battery types as well as to study other air‐sensitive materials in their native state.

25 ENERGY STORAGE↗

TRACER-CAT-LANL Aerosol Optics and Chemical Speciation - SPAMS

Aerosol size distribution, optical properties, and speciation data collected in La Port TX, during TRACER-CAT-LANL, July 2022, with basic trace gas measurements. All sampling was conducted with an identical aerosol inlet as the standard ARM-AOS systems. The TRacking Aerosol Convection interactions ExpeRiment Carbonaceous Aerosols Thrust by Los Alamos National Laboratory (TRACER-CAT-LANL, July 2022) was designed to complement the larger ARM TRACER science goals to understand convective cloud lifecycles and aerosol-convection interactions. TRACER-CAT-LANL is focused on understanding the relationship between particle composition and light absorption and the influence of water uptake on this relationship. This aerosol and trace gas data can be used to understand the relationship between particle composition and light absorption and the influence of water uptake on this relationship. Instruments Include: Picarro GHG Photoacoustic Soot Spectrometer (PASS-3) Humidified-cavity attenuated phase shift-single scattering albedo particulate matter monitor (H-CAPS-PMSSA) Soot Particle Aerosol Mass Spectrometer (SPAMS) Single-Particle Soot Photometer (SP2) Cloud Condensation Nuclei Counter (CCNc) Aerodynamic Particle Sizer (APS) Scanning Mobility Particle Sizer (SMPS)

54 ENVIRONMENTAL SCIENCES↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mass transfer coefficients, kL, and air-CO2 ingassing rates in 3.4 m2 and 1-acre raceway ponds.

The US DOE 2016 Billion Ton Update (Langholtz 2016) projected that CO2 in flue-gas from power plants or similar sources would limit U.S. algal biofuel potential to under 5 billion gallons gasoline equivalent (gge) per year, due to lack of sufficient land, water and other requirements near such flue gas sources. 2nd generation carbon capture technologies are proposed to overcome this constraint (Davis 2017), and could expand this resource potential nearly 10-fold, assuming CO2 costs near the future, 2025 DOE NETL, goal of $40/metric ton CO2. An alternative pathway is the direct uptake of air CO2 into the algal ponds through an increase in the air-CO2 transfer rate resulting from the reaction of CO2 with hydroxide ions. However, such a ‘chemical enhancement’ in mass transfer depends on a high pH in the culture, and, by extension, the ability of microalgae to maintain high rates of carbon assimilation under such conditions. Abiotic experiments characterized the air-CO2 mass-transfer rate in 1-acre and 3.4 m2 raceway ponds as a function of pH, with rates approaching 10 g C/m2-day at pH 12 in the brackish water tested, equivalent to a biomass productivity potential of near 20 g AFDW/m2-day (@ 0.47 g C/g AFDW). The mass transfer rate was found to be nearly independent of the mass-transfer coefficient, indicating that at turbulence levels achievable in typical raceway ponds, the system is reaction rate, rather than diffusion limited. In biotic trials with an unknown green microalga, biomass productivity in ponds receiving CO2 from only direct surface air-CO2 exchange averaged 5 +/- 0.5 g AFDW/m2-day in August - September central California conditions, about half-that of experimental controls fertilized with supplemental CO2. pH in the air-only treatment reached a maximum of 10.5, supporting a model predicted air-CO2 ingassing rate between 2-3 g C/m2-day, consistent with the observed biomass carbon assimilation rate. Results suggest that unique alkaliphilic strains are required if reliant on direct in-pond air-CO2 transfer for algal inorganic carbon supply, and that reaching an economically viable biomass productivity will require strains that thrive at pH 11 and above.

09 BIOMASS FUELS↗

Evaluation of a Process to Separate Ensiled Corn Grain and Stover for Improved Utilization as a Biomass Feedstock

Corn grain and chopped stover were stored anaerobically at 37% to 50% (w.b.) aggregate moisture content to create a unique biomass feedstock. However, after storage, the two fractions must be separated to accommodate different conversion pathways. In this work, a modified cleaning system from a grain combine harvester was evaluated to investigate its effectiveness in separating the grain from the stover. While this system has been purposefully built for this task, there is no previous literature on separating grain at high material other than grain (MOG) to grain ratios. Using this system, material was separated into four fractions: Grain, Tailings, Heavy MOG, and Light MOG. Subsamples were collected, oven dried, and then hydrodynamically separated to quantify the grain content in the four fractions. Several different configurations of air velocities, mass flow rate, material MOG: grain ratios, and sieve types and openings were investigated. Grain capture was defined as the fraction of the total grain dry mass collected in the grain and tailings fractions. In five experiments, the grain capture effectiveness varied from 89.2% to 99.4% on a dry basis. The dry basis foreign matter (FM) in the clean grain was 0.6% to 10.8%. As a result, the use of a modified combine cleaning system has the potential to be one step in a system to fractionate corn grain from stover (i.e., MOG) in a biorefinery that uses both starch and cellulose as biomass feedstocks.

09 BIOMASS FUELS↗

Controlled dehumidification to extract clean water from a multicomponent gaseous mixture of organic contaminants

Rapid expansion of the unconventional oil and gas extraction has increased American energy independence, but also led to increased production of large amounts of contaminated water. Wastewater from the oil and gas industry contains a wide range of contaminants. Injecting such contaminated water into disposal wells or discharging it to the environment jeopardizes freshwater resources. Conventional and membrane-based wastewater treatment techniques are often not effective choices to treat highly contaminated wastewater; however, a suitable way to remove contaminants from wastewater is to selectively separate water in a process analogous to humidification-dehumidification (HDH). Only a few studies have investigated the use of HDH for wastewater treatment. In this study, a novel HDH system is introduced for treating highly contaminated water, such as oil and gas flowback and produced water. In this HDH process, a non-condensable gas, such as air, mixes with wastewater vapor to facilitate the separation of contaminants. As a result, clean water condenses from the multicomponent gaseous mixture while air carries organic contaminants out of the dehumidification section. A laboratory apparatus was constructed and experiments were performed to investigate the HDH process for wastewater treatment and to study the effects of flow dynamics including air flow rate on the composition of treated water. Different contaminants including benzene, toluene, 2-propanol and 2-butoxyethanol were tested. Experimental results showed that the system can be successfully applied for removing volatile and/or toxic organic contaminants from wastewater. A representative multicomponent mixture of fracking wastewater was successfully treated using the experimental setup and clean water with quality of 98.3% was obtained. It was revealed that increasing the air-to-vapor mass ratio improves purity of treated water. Quantitative analysis showed that by increasing the air-to-vapor mass ratio from 0.6 to 5.9, the fraction of separated 2-propanol through the air was improved from 43% to more than 96% of the initial amount. ASPEN software was employed to simulate equilibrium conditions. Finally, experimental results were observed to have lower mass fraction of residual contaminant in the treated water compared to equilibrium state.

42 ENGINEERING↗

Skyshine Calculations for a Large Spent Nuclear Fuel Storage Facility with SCALE 6.2.3

The SCALE code system developed at Oak Ridge National Laboratory includes state-of-the-art capabilities for radiation source term and radiation transport simulations that can be used in numerous applications, including dose rate analyses of complex consolidated interim storage facilities (CISFs). A licensed CISF could be used to store tens of thousands of tonnes of spent nuclear fuel discharged from commercial power reactors using various cask and storage pad designs. A CISF design must comply with the regulatory requirements provided in 10 CFR Part 72, including requirements related to annual dose limits applicable to real individuals located beyond the area controlled by the licensee. Therefore, calculating a dose to the public is a necessary part of the licensing process for the construction of a CISF. These calculations are very challenging because of the complexity of the CISF design and the low magnitude of dose rate at large distances from the facility. This paper describes detailed far-field dose rate calculations performed for a proposed CISF using MAVRIC, the Monte Carlo radiation shielding sequence in SCALE 6.2.3, with automated variance reduction based on discrete ordinates calculations. The method presented in this paper uses a detailed Monte Carlo radiation transport simulation in one step from source to dose rate. A series of independent simulations was made using the complete site geometry (all casks present), but with only one cask containing radiation sources to obtain the dose rate maps produced by each storage cask. The CISF dose rate map was obtained by adding the dose rate maps produced by the independent individual cask simulations. Ample volumes of air and soil extending beyond the location of interest for dose rate calculation were included in the calculation model to properly simulate important radiation attenuation and scattering events that affect far-field dose rates. Furthermore, a comprehensive sensitivity study is included in this paper to illustrate the importance of selecting appropriate air volume, mass density, and composition for CISF skyshine dose rate calculations. Dry soil and soil containing water were analyzed to determine their effects on groundshine radiation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of Expedited Results from Samples Supporting Tank Closure Cesium Removal (TCCR) Batch 3

Savannah River Remediation (SRR) is currently operating the Tank Closure Cesium Removal (TCCR) process to remove 137 Cs from tank waste supernate using an ion exchange process. As part of that process, Savannah River National Laboratory (SRNL) receives and analyzes samples in support of the qualification of each batch to be processed. SRNL recently received supernate samples retrieved from Tank 10H as well as in-tank batch contact samples for characterization in support of qualifying Batch 3 for processing through the TCCR unit. SRNL received and characterized a set of dip samples collected from Tank 10H (one surface and one variable depth sample). No solids were observed in either sample and therefore the samples were combined, and a suite of analyses were performed on the composite sample. The density of the combined sample was 1.174 g/mL (0.18 %RSD), which was consistent with the measured sodium concentration of 3.54 M (0.08 %RSD). The 137Cs activity in the sample was 4.75E+07 dpm/mL (4.28 %RSD) and the total Cs concentration was calculated to be 1.54 mg/L (1.16E-05 M). The in-tank batch contact samples consist of 0.1 g of crystalline silicotitanate (CST) contained within a teabag device. Duplicate samples were submerged in Tank 10H supernate for a period of about 13 days, after which time they were retrieved and transferred to SRNL for analysis. At SRNL the CST was rinsed to remove excess salt solution and the CST was then air dried before being digested for analysis. Results of the analysis indicated a 137 Cs loading of 3.66E+10 ± 1.40E+09 dpm/g or 16.5 ± 0.63 Ci/kg CST . This value represents a bounding upper limit as it includes the addition of two sigma uncertainty from replicate analysis of the individual teabag samples as well as the addition of the small amount of 137 Cs activity measured in the rinse solutions. The above values are based on the air-dried mass of CST. Correcting to the true dry mass using a F-factor of 0.8191 results in a maximum loading of 20.2 ± 0.77 Ci/kg CST .

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Creating an Advanced Sensor Network to calculate real-time, mass-weighted flue gas composition and air heater leakage of a coal-fired utility boiler under dynamic operating conditions

Utilization of renewable energy sources to minimize the environmental impact of energy production has changed the way utility boilers operate, requiring frequent load cycling between full load and partial loads as low as 30%. Dynamic operation of coal-fired utility boilers significantly reduces boiler efficiency when compared to steady state at full load. Data-driven plant optimization has shown success with coal-fired utility boilers under dynamic operating conditions. The purpose of this work was to create an Advanced Sensor Network (ASN) to provide more extensive real-time data to inform dynamic plant optimization of Net Unit Heat Rate (NUHR). The ASN consists of gas sampling grids in the convective pass of the boiler and downstream of the air heater. These sampling grids allow for quantification of spatial variation of flue gas within the boiler and calculation of mass-weighted composition of flue gas through the combination of composition, velocity, and temperature measurements. The comparison of O 2 between the inlet and outlet of the air heater is used to calculate air leakage in real time. Flue gas composition and air heater leakage are both important factors in boiler efficiency and NUHR. Further, the results of this work support the value of mass-weighted averages for determining flue gas composition accurately. The measurements from the ASN show increased composition stratification during dynamic operation, with an average standard deviation 38% higher than observed during steady-state operation. Air heater leakage was also observed to increase from 2.8% to 5.1% following a load change. Prior to the installation of the ASN, these data would not have been available for dynamic control. These real-time data will be leveraged to calculate and optimize for NUHR during dynamic operation in future work.

42 ENGINEERING↗

Turbulence and Cloudiness in Cumulus-Topped Marine Boundary Layers

Turbulence and cloudiness in cumulus-topped marine boundary layers are studied using data from the Atmospheric Radiation Measurement (ARM) Eastern North Atlantic (ENA) site. The analysis includes eight periods of nonprecipitating shallow cumulus clouds, spanning 141 h and encompassing 603 individual clouds. On average, the cumulus had bases at 558 m, were 99 m thick, had a chord length of 500 m, and exhibited an hourly base-layer cloudiness of 12%. Changes in cloud fraction were primarily driven by variations in cloud number not chord length. High-resolution Doppler lidar and cloud radar observations were used to estimate updraft and downdraft mass fluxes in the cumulus base layer under both clear and cloudy regions. Cloudy updrafts contributed only ∼23% of the total updraft mass flux at cloud base, indicating that most upward mass flux originated from clear-air eddies. Updraft strength, rather than updraft fraction, was found to predominantly control both clear and cloudy updraft mass fluxes. Cloud-base cloudiness strongly correlated with cloudy updraft mass flux but showed negligible correlation with clear-air updraft mass flux. Clear-air downdraft mass flux exhibited a strong relationship with the ratio of surface buoyancy to inversion strength. Mesoscale analysis revealed that moist patches had greater cloudiness, updraft mass flux, and vertical velocity variance compared to dry patches. Additionally, mesoscale base-layer cloud fraction was highly and significantly correlated with cloudy updraft mass flux in both dry and moist environments. Results presented herein have implications for cumulus parameterization development along with climatological and model evaluation studies conducted at the ENA site.

cumulus clouds↗

BSEC Air Quality: Stationary Aerosol Composition and Mass Concentration at Baltimore

Data is 10-min average mass composition and mass concentration from the TOF-ACSM-X and Aethalometer AE33. TOF-ACSM-X reports fine (less than 2.5 um diameter) non-refractory aerosol, including organic aerosol, sulfate, nitrate, ammonium, and non-refractory chloride. Aethalometer measured the attenuation at different wavelengths for aerosol collected onto tape; one wavelength is used to convert to black carbon mass concentration. Also reported is the elemental ratios determined for organic aerosol (O/C, H/C, and organic matter to organic carbon ratio, OM/OC).

aerosol↗

BSEC Air Quality: Stationary Aerosol Composition and Mass Concentration at Baltimore

Data is 10-min average mass composition and mass concentration from the TOF-ACSM-X. TOF-ACSM-X reports fine (less than 2.5 um diameter) non-refractory aerosol, including organic aerosol, sulfate, nitrate, ammonium, and non-refractory chloride. Also reported is the elemental ratios determined for organic aerosol (O/C, H/C, and organic matter to organic carbon ratio, OM/OC). Finally, ion ratios of key ions used for identifying sources, ammonium balance, and fractional contribution of organic nitrate aerosol to total aerosol nitrate has been included.

aerosol↗

Modeling and Experiments on a Dedicated Outdoor Air System Using Liquid Desiccant Heat and Mass Exchangers

Liquid desiccants can provide efficient dehumidification but have yet to see widespread adoption. Most systems studied previously use natural gas-combustion to heat and regenerate the desiccant, and a central chiller plant or cooling tower for removing the heat of absorption. Here we present modeling and experimental results on a novel packaged air conditioner integrating liquid-desiccant heat and mass exchangers with a vapor compression cycle. The packaged system does not need cold or hot water from a central plant or cooling tower and is suitable for rooftop unit air conditioners. The system uses the evaporator to cool the liquid desiccant that is absorbing moisture from the air, and the condenser to heat the liquid desiccant to regenerate it. Efficiency is improved by reducing the load on the evaporator for a given supply-air dewpoint. This paper presents the measured dehumidification efficiency for a 10- ton packaged air conditioner, focusing on dehumidifying ventilation air. The paper also presents a numerical model to predict the outlet conditions and dehumidification efficiency, which we compare with the measured data.

air conditioning↗

Meta-Study of Particulate Detection Losses on Radioactive Air Sample Filters

Several mathematical relationships between air sample filter mass loading and the correlated analytical self-absorption factor were developed using data from other published research in this meta-study. Gross-alpha and -beta applications are addressed for this research. As filter media becomes loaded with particulate matter, there is potential for measurement losses due to self-absorption by mass loading. Components contributing to absorption include particulate dust, radioactive particulates, and filter material. Standards indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the detection rate by more than 5%. Previously, losses due to self-absorption have been reported up to 100% over a range up to ~10 mg∙cm -2 mass loading. These absorption losses then can be used to determine a correction factor for sample results. For low mass loadings (e.g., ≤0.1 mg∙cm -2 ) corrections factors in the 0.85 - 1 range have been recommended and used, while at higher mass loadings nearer to 10 mg∙cm -2 correction factors closer to 0 (representing near 100% losses) are used. Based on data from published studies, the different methods for relating percent loss due to self-absorption to mass loading include linear, exponential, quadratic, and trinomial derived functions. Where applicable, both forced zero and non-forced zero results were evaluated. From the derived functions evaluated, the trinomial function provided the best fit. Once the sample filter mass loading is known, the trinomial function can be applied to estimate losses and the corresponding self-absorption factor. When applied to routine operating conditions for radiological facility stacks monitored at the Pacific Northwest National Laboratory for an average sample filter mass loading of 0.09 ± 0.12 (2σ) mg∙cm -2 (excluding negative values and outliers) and a range from 0 - 0.24 mg∙cm -2 , the estimated trinomial function nominal self-absorption losses are less than 5% at 0.09 mg∙cm -2 and less than 10% at 0.24 mg∙cm -2 . The trinomial function is one method that may be used to adjust the activity results of an air sample when the sample-specific mass loading is determined. The application of no correction factor when the ANSI/HPS N13.1-2021 guidance of a 5% threshold for loss is not reached with typical stack sample mass loadings may be reasonable in high-efficiency particulate air filtered systems. For simplicity, it would be conservative in assigning the self-absorption correction factor at the 5% threshold (i.e., 0.95) for general uses but in cases of heavy mass loading to calculate the factor.

air sampling↗

Cutting edge research and new technologies in heat and mass transfer processes of refrigeration and air conditioning systems

This special edition of the Science and Technology for the Built Environment (STBE) presents eight selected articles originally presented at the 17th International Refrigeration and Air Conditioning Conference held at Purdue University, West Lafayette, IN, USA, during July 9–12, 2018. All eight articles were significantly expanded with additional technical content and received full peer review before being finally accepted for publication in this special issue of the STBE. The eight articles in this special issue cover a wide range of topics from condensation and evaporation of low global warming potential (LGWP) refrigerants to phase change material storage for personal cooling systems, from frosting on hydrophilic and hydrophobic coated surfaces to geometry optimization of heat exchanger fins. Furthermore, these articles describe cutting-edge research and feasibility studies of new technologies that were recently investigated for refrigeration and air conditioning applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CROCUS Air Quality Data at Northeastern Illinois University Rooftop

This dataset is from the Department of Energy Office of Science funded project, Community Research on Urban and Climate Science (CROCUS) (https://crocus-urban.org/). The AQT (Vaisala AQT530) instrument provides observations on meteorological conditions, including particulate matter (PM2.5, PM10), gas species concentrations (NO, NO2, O3, CO), and environment temperature and moisture. These measurements are critical for understanding air quality. These measurements are useful for understanding changes in aerosol properties, air quality research, and comparing to model experiments especially in urban environments.Datasets are stored in the netCDF data format, and we we encourage users to make use the associated toolkits available from Unidata (https://www.unidata.ucar.edu/software/netcdf/), Project Pythia (https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html), and our “Instrument Cookbooks” (https://crocus-urban.github.io/instrument-cookbooks) for more information on how to process the metadata-rich datasets.

54 ENVIRONMENTAL SCIENCES↗