Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air separation unit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Bulk Anion Recognition Kinetically Holds Back Interfacial Adsorption

The competition between bulk and interfacial phenomena underlies many key processes in complex chemical phenomena and transport. While competitive processes are often framed in a thermodynamic context, opportunities to leverage transient species found away from equilibrium can provide a kinetic handle to achieve unconventional reaction outcomes. In this work, we outfit an iminoguanidinium headgroup capable of selective SO 4 2– complexation with alkyl tails of varying complexity to probe competitive bulk and interfacial reaction pathways and tune kinetic pathways for selective chemical separations. Using sum frequency generation (SFG) vibrational spectroscopy we unexpectedly find that adsorption of ligands to the air–aqueous interface was dramatically slowed down for species with increasingly hydrophobic tails. Underlying this phenomenon, we show that the formation of bulk colloidal species with differing propensities for SO 4 2– inhibited surface adsorption via a kinetic bottleneck in the exchange of molecular extractants with colloidal aggregates. This kinetic effect could open up avenues to access unconventional selectivity via complexation of strongly coordinating species in the bulk phase, allowing for more weakly coordinating species to transport via interfacial mechanisms. Furthermore, this work broadly probes nonequilibrium phenomena in chemical separations that arise through unexpected interfacial events that are neglected in traditional equilibrium descriptions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SPRUCE Whole Ecosystem Warming (WEW) Environmental Data and Water Table Summaries, Marcell Experimental Forest, Minnesota, 2015-2024

This data set contains observations of photosynthetically active radiation (PAR), precipitation, soil temperature, soil volumetric water content, air temperature, relative humidity, and normalized water table depth that are summarized on a daily, weekly, monthly, and annual basis for each of the SPRUCE plots. Observations span 2015-2024. This dataset draws on several datasets (Hanson et al. 2016; Hanson et al. 2020; and Warren, unpublished data) and compiles these environmental observations into useful formats for data analysis. These environmental metrics can be used to understand the environmental conditions inside SPRUCE environmental chambers throughout the durations of the experiment and can be paired with other data for modeling and analysis. R code used to generate these files is provided as part of the data package. This dataset contains four data files in comma separate (.csv) format and a compressed folder (*.zip) containing three R (*.r) scripts. Additional metadata are provided: one data dictionary and a file-level metadata file in comma separate (.csv) format and a user guide in PDF (*.pdf) format. User note: Users must cite the original dataset/s along with this dataset when publishing any analyses using this dataset. Details on the dataset used to compile each variable are available in the header row of the files and in the user guide.

air temperature↗

Direct Air Capture Using Aqueous Amino Acid Solvents in a Crossflow Absorber

Carbon dioxide (CO 2 ) is the most abundant of all greenhouse gases (GHGs). CO 2 levels in the atmosphere are 50% higher than in the preindustrial era, trapping heat. CO 2 removal from the atmosphere by direct air capture (DAC) is needed to achieve the internationally agreed global temperature goals. The most common CO 2 capture technology is absorption by aminebased solvents in packed columns. Amino acid solutions have recently gained attention due to their advantages over traditional amine solvents. To be implemented effectively, DAC industrial processes need to handle large airflow rates in separation absorbers. The large air and solvent flow rates preclude the use of countercurrent columns due to high-pressure drops and the occurrence of flooding. Crossflow air−liquid absorbers are used to handle large air and liquid volumes due to their lower-pressure drop. The objective of this work is to study the influence of crossflow absorber geometric parameters and operating conditions on product formation and process efficiency. An already derived theoretical model for countercurrent absorbers has been modified to simulate the operation of a crossflow DAC absorber. The predictive model was implemented into a computer code that was used to study the efficiency of the processes as geometric equipment dimensions and operating parameters vary. Practical suggestions are made to design more efficient DAC processes.

Absorption↗

Particulate Effluent Characterization (Final Report)

Understanding particulate emissions from nuclear facilities could help differentiate between normal nuclear operations and potential nuclear accidents or nuclear weapons tests. Oak Ridge National Laboratory (ORNL) is unique in that there are several types of nuclear facilities on site: an operating production reactor, radiochemical separation facilities, and a spallation neutron source. This project deployed a high-volume particulate air filter sampler to collect airborne particulate effluent from the nuclear facilities on site at ORNL. Collections occurred regularly from November 1, 2024, through June 30, 2025, and were analyzed via gamma spectroscopy in the laboratory. The radioisotope iodine-123 ( 123 I) was detected in several samples throughout the collection period. Detailed atmospheric transport modeling was performed on all detections for source attribution, and the most likely source of the 123 I was determined to be the Spallation Neutron Source. The project demonstrated the viability of ORNL as a test bed for effluent monitoring studies.

54 ENVIRONMENTAL SCIENCES↗

Reversible self-assembly of small molecules for recyclable solid-state battery electrolytes

Performance often overshadows recyclability in contemporary battery designs, leading to sustainability challenges. Preemptive strategies integrating recyclable chemistry from the outset are thus increasingly critical for addressing the complexities in conventional recycling. Here we harness bio-inspired molecular self-assembly to create inherently recyclable battery materials. We use aramid amphiphiles that self-assemble in water through strong, collective hydrogen bonding and π–π stacking, forming air-stable, high-aspect-ratio nanoribbons with gigapascal-level stiffness. When processed into bulk solid-state electrolytes, these nanoribbons retain their ordered molecular arrangement and exhibit total conductivities of 1.6 × 10 −4 S cm −1 at 50 °C, Young’s moduli of 70 MPa and toughness values of 1 MJ m −3 , despite being stabilized solely by reversible non-covalent bonds. We further demonstrate clean separation of battery components by exposing used cells to an organic solvent, which disrupts the non-covalent cohesion and reverts all battery components to their original forms. Furthermore, this study underscores the potential of molecular self-assembly for specialized recyclable designs in energy storage applications.

Batteries↗

Dry Deactivation of Sodium Metal in a Molten LiCl-KCl-CsCl-NaCl System

An experimental study was performed with the objective of investigating and characterizing a dry technique for deactivation of sodium metal in a molten salt system. The study was performed in three parts. First, proof-of-principle testing of the technique was performed at bench scale. It involved loading and melting tens of grams of clean sodium metal atop a pool of LiCl-KCl-CsCl eutectic at ∼300°C and then adding ammonium chloride particles while mixing. The ammonium chloride reacted with sodium to form sodium chloride and nitrogen/hydrogen off-gases. The sodium chloride assimilated into the salt pool, forming a quaternary salt mixture of LiCl-KCl-CsCl-NaCl. The proof-of-principle testing repeatedly exhibited complete deactivation of the loaded sodium metal. Second, characterization of a LiCl-KCl-CsCl-NaCl system was performed using differential scanning calorimetry to produce a partial phase diagram of LiCl-KCl-CsCl eutectic versus NaCl, which identified the liquidus, solidus, and two-phase regions of the quaternary system. Third, the dry deactivation technique was demonstrated at kg-scale in an inert atmosphere radiological glovebox with sodium metal that was previously separated in the same glovebox from uranium metal in unirradiated blanket elements for the Fermi-1 nuclear reactor. The quaternary salt product at the end of the demonstration was sampled and showed complete deactivation of the sodium metal. Here, in short, this study qualified a technique to completely deactivate batches of sodium metal in the absence of air or water. While this study focused on the deactivation of sodium metal, including bond sodium from unirradiated blanket elements, the technique is applicable to other sources of sodium metal, such as sodium metal from batteries. Furthermore, the technique could also be extended to other alkali metal systems, including lithium, sodium, potassium, rubidium, cesium, and mixtures thereof.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a versatile plate spectrometer for electron beam characterization

A new instrument for electron beam characterization has been developed, based on measuring the range of beam electrons in different thicknesses of aluminum, to determine both the current and energy of an electron beam traveling in open air. This instrument is referred to as a ‘plate spectrometer’ as the thickness of the spectrometer is adjusted by adding or removing aluminum plates. This spectrometer was assembled and then characterized at the Idaho Accelerator Center (IAC) with three different beam energies and with one beam energy at the University of Maryland Radiation Facilities. The plate spectrometer was able to match the median energies and provide a reasonable constraint to the beam distributions seen in the IAC magnetic spectrometer. Finally, in a separate experiment, the plate spectrometer was also seen to agree with a dosimetry characterization of the beam at the University of Maryland Radiation Facilities and improved upon the uncertainties of this measurement.

43 PARTICLE ACCELERATORS↗

Advances in Desiccant Wheels for Dehumidification, VOC Mitigation, and CO 2 Removal for Energy-Efficient IAQ Management

Humidity control is pivotal to maintain occupant thermal comfort and suppress mold growth in indoor environments. Furthermore, poor indoor air quality (IAQ) due to the presence of volatile organic compounds (VOCs) and high concentrations (>1,000 ppm) of CO 2 can cause health issues and negatively affect cognitive performance. Therefore, providing high-quality indoor air has gained significant attention over the past decade. Conventional cooling coil and filter-based HVAC systems have limited capability to meet the augmented demand for occupant thermal comfort and high indoor air quality. Moreover, modern buildings are increasingly airtight to save energy, and increasing ventilation to mitigate VOC and CO 2 concentration is discouraged. Separate sensible and latent cooling technology using a rotary desiccant wheel presents a promising solution in this respect. Because of the development of desiccant materials with high water vapor, VOC, and CO 2 uptake, desiccant wheels can be used as an integrated technology option for IAQ management. Here, to promote desiccant wheel use for energy-efficient management of IAQ in buildings, this article reviews recent advancements in using desiccant wheels for dehumidification, VOC mitigation, and CO 2 capture from outdoor air. Finally, the article presents the authors’ perspective by summarizing the key research gaps in the field and discussing the future direction of research to address these gaps from two different aspects, namely, suitable adsorbent material development and desiccant wheel design.

CO2 capture↗

ALARA Review for Venting of Flanged Tritium Waste Containers (FTWCs) at TA-54

This project will vent headspace hydrogen and oxygen from specialized high-pressure storage vessels called flanged tritium waste containers (FTWCs). There are four of these containers located in Los Alamos National Laboratory’s (LANL’s) Technical Area 54 (TA-54), Building 1028. This building is in the southwest corner of LANL’s Material Disposal Area G. The vented headspace gas is expected to contain tritium in the form of water vapor, elemental hydrogen or a combination of both. The venting operation is expected to take place in 2025. There will be a series of operational readiness reviews prior to venting activities commencing. The FTWCs at TA-54 contain tritium-contaminated metal parts and molecular sieve media, which is a pebble-like material used to absorb water vapor from the air. This molecular sieve media inside the FTWCs is contained in metal canisters, along with some loose media material in bags. Over time, tritiated water vapor that had been adsorbed onto the media can become liberated into the FTWC headspace gas. Radiolysis can cause separation of the water vapor into its hydrogen and oxygen components, resulting in the potentially hazardous gas mixture within the FTWC. LANL has determined that continued tritium storage in these containers can pose an unsafe condition due to possible hydrogen and oxygen gas buildup within the FTWCs with a potential for explosion if sparks are generated within the FTWCs. To mitigate this hazard, the FTWCs will be stabilized by venting them in-place to remove hazardous gases.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Techno Economic Analysis for Production of Renewable Natural Gas and Value-Added Chemicals from Forest Biomass Residues (CRADA Final Report)

West Biofuels - in collaboration with the University of California San Diego, the University of California Davis, the National Laboratory of the Rockies (NLR), the Colorado School of Mines’ Center for Hydrate Research, Placer County Air Pollution Control District, the Sierra Business Council, and the Southern California Gas Company (SoCalGas)-will demonstrate an innovative pathway to convert forest biomass to renewable gas (RG). The project, Production of Pipeline Grade Renewable Natural Gas and Value-Added Chemicals from Forest Biomass Residues, will utilize an existing pilot-scale gasification system and data and lessons learned from a lab-scale catalytic reactor design, develop, and demonstrate an integrated pilot-scale RG process with a scaled-up catalytic reactor and hydrate-based gas separation process. This robust and simple process uses a commercial proven gasifier, a commercially available catalyst that can tolerate gas contaminants, and a gas separation process that simplifies the downstream processing. Current testing has shown that the process can yield a large amount of methane rich renewable gas in addition to a mixture of propanol, ethanol and other higher alcohols and the relative amounts can be controlled by shifting the process conditions. This process is novel and groundbreaking because the product mixture of RG and valuable alcohols byproducts makes RG production economically feasible at $\$$12 per million British thermal units (MMBtu) or less using forest biomass from high hazard zones.

09 BIOMASS FUELS↗

The Argonne SuperGel for CBRN Decontamination - 20160

The Argonne SuperGel was developed between 2003 and 2015 to fill a gap in our nation's capability to quickly decontaminate important structures following a radiological or nuclear release event. Specifically, the decontamination technology was developed to minimize damage to monuments, high valued structures, and critical infrastructure while reducing environmental and health impacts. An important criterion during its development, common reagents were employed that could be easily acquired in order to minimize the timeline for its deployment. Its current formulation uses off-the-shelf super-absorbing hydrogels common to the food and agricultural industry and common salts. Over the years, two formulations of the Argonne SuperGel have been developed to specifically target radioactive cesium contaminations and then, more generically, actinide and fission product contaminations. A biodegradable derivative of phosphoric acid is used in small amounts to promote the removal of insoluble actinide species. The original order of unit operations for the SuperGel technology was 1) applying the wash solution to promote mobility of the contaminants on the surface, 2) applying the hydrogel to absorb the wash solution and contaminants, and 3) removing the hydrogel for disposal. During the course of our studies, we tested a new formulation of the gel technology that eliminated the need for a separate step to apply the wash solution without a compromise in decontamination factors. Greater than 70% and >95% of Cs-137 were removed from concrete and tile coupons, respectively, after two decontaminations, with the best results using wash solutions of 1.0 M KCl and 1.0 M NH{sub 4}Cl formulations. We found no statistical difference between results at 30 deg. C and 40 deg. C or at 70% and 90% relative humidity. We tested the gel under strong UV irradiation to simulate extreme environments. While a tropical noontime UV flux did not adversely affect the gel system decontamination of Cs-137 from concrete or tile coupons, the noontime flux resulted in significant dehydration of the gel after two hours of constant exposure. The rehydration of the gel by the humid air (at 90% humidity and 40 deg. C) was slow and may not be sufficient to offset dehydration by the sun. Americium decontamination from concrete was 70% after optimizing the phosphoric acid derivative and carbonate salt concentration in the wash solution. Since its development, we have had the opportunity to test the SuperGel in the removal of legacy contaminations in hot cell facilities and former glovebox facilities at Argonne. This has provided a unique opportunity to evaluate the SuperGel on a range of contaminants outside the original specifications for its use. We will report on the origin of the gel formulation, some highlighted experimental data including independent testing by the US EPA which has never been reported, and its efficacy for removing legacy alpha contaminations and its potential use for removal of chemical and biological hazardous agents. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NFE-24-10417: Durability and Life-time Energy Performance Enhancement of Vapor Compression Systems

This project investigated the use of a Centrifugal Particle Separation (CPS) system to improve the durability and operational reliability of outdoor heat exchangers in vapor-compression based heating, ventilation, air conditioning, and refrigeration (HVACR) systems. The developed method introduced a novel dust and fouling mitigation approach by integrating an ambient air pre-cleaner that employs centrifugal forces to remove particulate matter from incoming air before it reaches the heat exchanger. By reducing the accumulation of dust and debris on coil surfaces, the CPS system aims to lower maintenance requirements and extend equipment lifespan. The project specifically involves coupling a centrifugal air pre-cleaner with a single-zone ductless mini-split system and evaluating its effectiveness in maintaining cleaner coil surfaces. Additionally, the study examined the impact of CPS integration on system energy performance. Through controlled experimental testing and performance monitoring, this work seeks to validate CPS-based air pre-cleaning as a practical, efficient solution for mitigating outdoor coil dust accumulation and fouling in both residential and commercial HVACR applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) HEPA Filtration System - 20165

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous High Efficiency Particulate Air (HEPA) filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The integrated system design provides for reducing the salt, clay and diesel particulates from the exhaust airflow from the mine, prior to full filtration using Nuclear Safety Significant HEPA filters. The SSCVS design and equipment provides for continuous HEPA filtration over a wide range of operating and environmental conditions. The new exhaust system connects to the existing underground exhaust shaft, and the exhaust air flows from the underground through Salt Reduction Units (SRUs) to protect the final filter banks from excessive moisture and rapid salt/dust buildup. Each of the six (6) SRUs consists of a demister to remove entrained moisture, a dry salt remover unit to filter approximately 90% of the entrained salt/dust, and an automated water treatment system to periodically clean the demisters and to remove salt from the SRU filters. At the maximum expected exhaust flowrate of 540,000 Cubic Feet per Minute (CFM) / 255 Cubic Meters per Second (m{sup 3}/s), five (5) salt removal units will be in operation with one unit in standby or maintenance. An in-line variable frequency drive booster fan will offset pressure losses through each SRU and reduce the relative humidity of the air exiting the SRUs. In the event of a high radiation alarm from the underground Continuous Air Monitors (CAMs), the SRUs will be automatically bypassed, which places the SRS and building outside of the Safety Significant confinement boundary. From the SRUs, the exhaust is directed to the HEPA filter banks located in the New Filter Building. The exhaust system is designed to provide continuous HEPA filtration prior to release to the exhaust stack. There are 22 HEPA filter banks rated at 27,000 CFM / 12.75 m{sup 3}/s each. Each filter bank has two stages of pre-filters and two stages of HEPA filters. The filtered air from each of the 22 filter banks discharges into a common concrete plenum, which is maintained under a negative pressure by the main exhaust fans. Six 1,000 HP variable frequency drive exhaust fans are provided on the south side of the plenum. At the maximum expected exhaust flow of 540,000 CFM, four exhaust fans and twenty filter banks will be in operation. The fans discharge vertically to a separate concrete exhaust plenum. The filtered exhaust is routed from the exhaust plenum to a 125-foot-tall exhaust stack via a 13-foot diameter duct. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Uniform Methods Project: Smart Thermostat Evaluation Protocol

A smart thermostat is an internet-connected device that controls home heating, ventilation, and air-conditioning (HVAC) equipment and can automatically adjust temperature set points to optimize performance and achieve energy savings. Smart thermostat features often include two way communication, occupancy detection (such as geofencing and occupancy sensors), schedule learning, and seasonal optimization algorithms. Smart thermostats can control most conventional HVAC systems, including central air conditioners, heat pumps, and forced air furnaces. Several types of residential utility programs offer smart thermostats as replacements measures. Working with smart thermostat vendors, utilities can offer separate optimization programs to produce energy savings beyond those achieved by installing a smart thermostat. From an evaluation perspective, smart thermostat programs have several noteworthy features. First, the energy savings from a smart thermostat may change over the life of the device. As a smart thermostat is connected to the internet, original equipment manufacturers can update the thermostat software to improve the thermostat's energy efficiency. Likewise, users can adjust the thermostat settings and schedules over time in response to changes in weather, thermal comfort, energy prices, or preferences for energy efficiency. Additionally, many thermostat manufacturers offer seasonal optimization programs that recommend changes or make minor, automated adjustments to the thermostat settings to improve energy efficiency. These opt-in programs are now standard offerings for many smart thermostat manufacturers and provided at no additional cost to users. The potential for software updates and continuous optimization and the evolving nature of user interactions mean future energy savings may differ from first-year savings and the energy savings of smart thermostats may need to be evaluated more than once. Second, smart thermostats often have small unit energy savings relative to a home's total energy consumption, especially in comparison to whole- home retrofit programs. This can make it difficult to detect the smart thermostat savings in billing or advanced metering infrastructure (AMI) meter consumption data. For example, as cooling loads in many regions average about 20% of annual electricity consumption, smart thermostat savings of 10% of cooling energy use would equate to a 2% reduction in home electricity consumption. Evaluators should use regression analysis of whole-home billing consumption or advanced metering infrastructure (AMI) meter consumption data to evaluate smart thermostat savings because, as explained at greater length below , these data are usually available to evaluators and regression can control for the impacts of weather and other potentially confounding factors on a home's energy consumption. Finally, as with other energy efficiency programs, participation in smart thermostat programs is self-selective. As discussed at greater length below , smart thermostat participants tend to be, among other things, younger, higher-income, and more likely to adopt electric vehicles (EVs) and internet connected devices than nonparticipants. These differences are often unobservable to the evaluator and correlated with a home's energy consumption, creating the potential for bias in estimating savings. Due to the small unit savings of thermostats, errors and biases from self-selection that may not be very consequential when evaluating a whole- home retrofits (e.g., ±2% of home electricity consumption) can have a major impact when evaluating the savings and cost-effectiveness of smart thermostat programs. A percentage point change in the estimated savings could affect the cost-effectiveness of a program. This means it is important for evaluators to assess and to minimize the potential for error from selection bias in estimating smart thermostat program savings. The Uniform Methods Project provides model protocols for determining energy savings and demand reductions that result from specific energy efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol ; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The UMP protocols can be used by utilities, program administrators, public utility commissions, evaluators, and other stakeholders for both program planning and evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of PRIM for understanding patterns in carbon dioxide model-observation differences

Reducing uncertainties in regional carbon balances requires a better understanding of CO 2 transport in synoptic weather systems. Here, we apply the Patient Rule Induction Method (PRIM), a data-mining method to identify high-density regions for a target-class within an input parameter space, to airborne observations of potential temperature, wind speed, water vapor mixing ratio, and CO 2 dry mol fraction gathered during the Atmospheric Carbon and Transport (ACT)-America Summer 2016 and Winter 2017 campaigns. ACT observations were targeted at expert-designated cases of fair weather and near-frontal warm and cold sector air at atmospheric boundary-layer, lower-, and higher free tropospheric levels (ABL, LFT, and HFT, respectively). We investigate atmospheric characteristics of these pre-defined cases and associated CO 2 model-observation-differences in the mesoscale WRF-Chem model. PRIM results separate winter- and summertime observations as well as observations from ABL, LFT, and HFT with enrichment factors of 4.0–20.5 inside the PRIM box compared to the entire dataset but cannot distinguish between near-frontal warm and cold sector observations in the higher free troposphere. Analyzing of the parameter space constrained by PRIM, we find that large magnitude model observation differences preferentially associated with times when atmospheric conditions are less typical. This association suggests that PRIM could provide a useful tool for isolating atmospheric conditions with large-magnitude and non-Gaussian CO 2 -residuals for targeted transport model evaluation and to potentially improve inversion results during synoptically active periods.

Gerken, Tobias [James Madison Univ., Harrisonburg,↗

A Transferable Force Field for Simulating Adsorption in Metal–Organic Frameworks with Open Metal Sites Based on the 12–6–4 Lennard-Jones Potential

Metal−organic frameworks (MOFs) that contain coordinatively unsaturated open metal sites (OMSs) provide strong host− guest interactions, making them promising sorbents for low-concentration gas adsorption applications such as direct air capture and atmospheric water harvesting. However, accurately modeling host−guest interactions involving OMSs remains challenging for classical force fields (FFs) based on the 12−6 Lennard−Jones (LJ) potential, as the polarization effect of the guest molecule induced by the positively charged OMS is not considered. Here, we introduce an FF based on the 12−6−4 LJ potential, which incorporates charge−induced dipole interactions and is parametrized against a diverse set of host−guest potential energy surfaces (PESs) obtained from density functional theory (DFT). The resulting FF, trained on a generic trimetallic cluster, performs well in both host−guest binding energetics and gas adsorption isotherms across different OMS-containing MOFs, including MOF-74 series and Cu-BTC. These results highlight the excellent transferability of our approach and its potential to enhance the accuracy and robustness of high-throughput MOF discovery workflows, particularly for gas adsorption and separation in large and diverse MOF databases.

36 MATERIALS SCIENCE↗

Laser Measurements and Modeling of Shock Tunnel Freestream Velocity and Multispecies Thermal Nonequilibrium

Coherent anti-Stokes Raman scattering (CARS) and nitric oxide molecular tagging velocimetry (NO-MTV) were used to characterize the freestream in Sandia’s Hypersonic Shock Tunnel (HST) using a burst-mode laser operated at 100 kHz. Experiments were performed at nominal freestream velocities of 3 and 4 km/s using both air and N 2 test gas. The CARS diagnostic provides nonequilibrium characterization of the flow by measuring vibrational and rotational temperatures of N 2 and O 2 , which are compared to NO temperatures from separate laser absorption experiments. Simultaneous, collinear freestream velocities were measured using NO MTV along with pitot pressure measurements. Furthermore, this extensive freestream dataset is compared to nonequilibrium CFD that is capable of modeling species-specific, vibrational temperatures throughout the nozzle expansion. Significant nonequilibrium between vibrational and rotational temperatures was measured at each flow condition. N 2 exhibits the most nonequilibrium, followed by O 2 and NO. The CFD model captures this trend, although it consistently overpredicts N 2 and O 2 vibrational temperatures. At 3 km/s, the modeled NO nonequilibrium is underpredicted, whereas it is overpredicted at 4 km/s. Good agreement is seen between CFD and the velocity and rotational temperature measurements. Experiments with water added to the test gas yielded no discernable difference in vibrational relaxation.

Aerodynamics↗

Modeling and Optimization of a Rotating Packed Bed Contactor with a Tetraamine-Appended Metal−Organic Framework for CO 2 Capture

A potential contactor technology for sorbent-based CO 2 capture is the rotating packed bed that contains separate sections for continuous adsorption and desorption. A heat exchanger can be embedded to remove heat in the adsorption section and add heat in the desorption section. In this work, we develop a two-dimensional (2D) model of a rotating packed bed for use in CO 2 capture applications. Mass and energy balances for the model are developed based on a Ljungström-type air preheater, which accounts for the counter-current axial flow of gas phases in separate sections of the bed and the rotation of a solid sorbent, which cycles between adsorption and desorption sections. The sorbent used for this analysis is the tetraamine-appended metal−organic framework Mg 2 (dobpdc)(3−4− 3), chosen for its stability and affinity for CO 2 at low partial pressures, such as those from a natural gas power plant source. An optimization problem is solved that considers the trade-off between maximizing the productivity of the bed and minimizing energy consumption. Maximum productivity and minimum energy are found to be 8.53 kg/h/m 3 and 3.84 MJ/kg, respectively, when these objectives are optimized independently. It is observed that the flue gas pressure and bed rotational speed are the desired operating variables to vary for model-based design of experiments to reduce uncertainty in parameter estimation, as these two variables yielded the most information content based on the Fisher information matrix.

20 FOSSIL-FUELED POWER PLANTS↗