Search NASA⌕ Search

SEARCH · Search NASA

Results for “Airflow distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Cruise Propulsion System Thermal Analysis for NASA’s X-57 “Maxwell” Mod II Configuration

The X-57 “Maxwell” is NASA’s flight demonstrator for distributed electric propulsion technologies. The X-57 Mod II configuration is designed to test the electric cruise propulsion system for X-57 and features an electric cruise motor mounted in an integral nacelle on each wing. The electric motors and associated control equipment for X-57 Mod II are air-cooled; therefore, they require adequate cooling airflow to stay within temperature limits in all relevant flight conditions within the operational ambient temperature limits set by the X-57 project. A computational flow analysis was conducted to estimate the internal flow properties of the X-57 Mod II cruise nacelles in three critical flight conditions. These flow properties were then used to determine the boundary conditions for individual component thermal models, which were used to estimate individual component operating temperatures. The results indicated that the low-speed, low-altitude initial takeoff climb during hot day conditions was the sizing condition from a cooling perspective. The analysis found that the cooling flowpaths in the X-57 Mod II cruise nacelles are adequate to provide cooling to all components with the appropriate amount of thermal margin except two of the low-voltage control boards in the cruise motor controller. These components would violate required thermal margins by less than two degrees Celsius in the Project Hot Day reference atmosphere.

Nicholas K Borer↗

Investigation of inter-subject variation in ultrafine particle deposition across human nasal airways: A study involving children, adults, and the elderly

Occupational and environmental exposure to toxic nanoparticles, driven by the rapid expansion of nanotechnology, raises significant respiratory health concern. Numerous studies have explored airflow and particle dynamics in adult nasal airways, but understanding the impact of age-related anatomical changes in children and the elderly remains limited. This study systematically investigates age-related anatomical variations and associated influence on nasal airflow dynamics and ultrafine particle deposition characteristics. Using Computational Fluid-Particle Dynamics (CFPD) method, simulation was conducted under diverse inhalation conditions spanning a wide age range, including: two children (5 years old), two young adults (in their twenties), and two elderly (over 77 years old). Our results reveal distinctive variations across age groups in anatomical dimensions, which affect distribution of wall shear stress where the elderly and children display unique patterns distinct from the young adults. While total deposition efficiency differs significantly between children and adults, filtration efficiency in the subregion with most deposition, main respiratory, remains consistent. However, inter-subject differences are observed in the vestibular and olfactory regions,emphasizing nuanced impact of age-related anatomical variations. Overall and subregional empirical equations for deposition efficiency were developed by incorporating the combined diffusion parameter, Sc a Δ b , corroborating the use of geometrical characteristic parameters for each specific subject in predicting nasal deposition efficiency across age groups. Our findings contribute to predictive nanoparticle exposure analysis in nasal airways across different age groups, thereby enhancing respiratory healthcare for individuals across the life span.

60 APPLIED LIFE SCIENCES↗

Solar heating system at Quitman County Bank, Marks, Mississippi

Information on the Solar Energy Heating System installed in a single story wood frame, cedar exterior, sloped roof building is presented. The system has on-site temperature and power measurements readouts. The 468 square feet of Solaron air flat plate collectors provide for 2,000 square feet of space heating, an estimated 60 percent of the heating load. Solar heated air is distributed to the 235 cubic foot rock storage box or to the load (space heating) by a 960 cubic feet per minute air handler unit. A 7.5 ton Carrier air-to-air heat pump with 15 kilowatts of electric booster strips serve as a back-up (auxiliary) to the solar system. Motorized dampers control the direction of airflow and back draft dampers prevent thermal siphoning of conditioned air.

Source record↗

Low-Cost, User-Friendly, Rapid Analysis of Dynamic Data System Established

An issue of primary importance to the development of new jet and certain other airbreathing combined-cycle powered aircraft is the advancement of airframe-integrated propulsion technologies. Namely, engine inlets and their systems and subsystems are required to capture, convert, and deliver the atmospheric airflow demanded by such engines across their operating envelope in a form that can be used to provide efficient, stable thrust. This must be done while also minimizing aircraft drag and weight. Revolutionary inlet designs aided by new technologies are needed to enable new missions. An unwanted byproduct of pursuing these inlet technologies is increased time-variant airflow distortion. Such distortions reduce propulsion system stability, performance, operability, and life. To countermand these limitations and fully evaluate the resulting configurations, best practices dictate that this distortion be experimentally measured at large scale and analyzed. The required measurements consist of those made by an array of high-response pressure transducers located in the flow field at the aerodynamic interface plane (AIP) between the inlet and engine. Although the acquisition of the necessary pitot-pressure time histories is relatively straight-forward, until recent years, the analysis has proved to be very time-consuming, tedious, and expensive. To transform the analysis of these data into a tractable and timely proposition, researchers at the NASA Glenn Research Center created and established the Rapid Analysis of Dynamic Data (RADD) system. The system provides complete, near real-time analysis of time-varying inlet airflow distortion datasets with report quality output. This fully digital approach employs Institute of Electrical and Electronics Engineers (IEEE) binary data file format standardization to establish data-acquisition-system-independent processing on low cost personal computers. Features include invalid instrumentation code-out, logging, and multiple replacement schemes as needed for each channel of instrumentation. The AIP pressure distribution can be interpolated to simulate measurements by alternate AIP probe arrays, if desired. In addition, the RADD system provides for the application of filters that can be used to focus the analysis on the frequency range of interest.

Arend, David J.↗

Experimental testing of additively manufactured embedded fiber optic smart devices for clean energy applications

Abstract An additively manufactured prototype smart device was created to investigate in-flow temperature distributions using embedded high-definition fiber optic sensors within a component for clean energy systems. The devices were created using Ultrasonic Additive Manufacturing to create a unique embedded pathway within a flow conditioner for the high-definition fiber optic sensors to be placed within. The fibers used allowed for temperature measurements to be taken every 0.65 mm along the fiber. The high-resolution fibers were thermally calibrated enable the 2D reconstruction of the temperature profile in the flow path of the structure. This is due to the temperature-related strain response of the material and strain measurements of the fibers. Hot airflow testing of these devices showed the ability to identify localized temperature differences in the flow. The observed strain response within the smart device had higher strain concentrations in the thicker web regions than in the thinner web regions. These higher strain regions resulted in higher uncertainties for the temperature responses. Further calibration is needed to improve the accuracy of the smart devices, specifically within the inner web structures of a flow straightening component. Further investigations of the devices within flow showed the temperature sensing to be independent of the effects of flow velocity. The devices were able to distinguish temperature differences within single and two-phase flow and showed local sensitivity to the temperature changes with the identification of hot and cold spots. The presented results showed the viability of the smart device for obtaining detailed temperature distributions using common industrial components. Eventually, the goal for these smart devices will be to withstand higher temperature and pressure environments such as those experienced in nuclear, fusion, and concentrated solar energy systems.

Donlan, Connor F. (ORCID:0000000223317882)↗

High spatial resolution studies of galaxies in the far IR: Observations with the KAO, and the promise of SOFIA

NASA, in collaboration with the West German Science Ministry (BMFT), plans a larger airborne telescope as a successor to the Kuipper Airborne Observatory (KAO) that will achieve these goals. The Stratospheric Observatory for Infrared Astronomy (SOFIA) is entering the final stages of Phase B review with targeted new start early in the next decade. SOFIA is a 2.7 m diameter telescope that is carried in a Boeing 747SP. In addition to having 3 times the spatial resolution of the KAO, and 10 times the light gathering power, it will incorporate improvements over the KAO in lower optical emissivity and better telescope tracking stability. The thin primary mirror will equilibrate quickly to ambient temperature at an altitude which, accompanied by airflow improvements across the telescope cavity, will result in better image quality. The sensitivity of SOFIA will allow us to see a large number of typical bright galactic HII regions in local group galaxies. The spatial resolution of 8 seconds (full width half maximum Airy disk) at 100 microns will allow these regions to be measured independently, if they are distributed similarly to those in our own galaxy. At this spatial resolution, the disks of normal galaxies will be easily resolved out to distances of several hundred Mpc. This portion of space includes many of the superluminous galaxies discovered by the Infrared Astronomy Satellite (IRAS), and this spatial scale is relevant for studies of the morphology of regions of interaction among the majority of these galaxies that are members of colliding pairs.

Lester, Dan F.↗

Observations of the far ultraviolet airflow by the Ultraviolet Limb Imaging experiment on STS-39

The Ultraviolet Limb Imaging (UVLIM) experiment flew on STS-39 in the spring of 1991 to observe the Earth's thermospheric airglow and included a far ultraviolet (1080-1800 A) spectrometer. We present first results from this spectrometer, including a spectroscopic analysis at 6-A resolution of H, O, N, and N2 dayglow emissions and modeling of the observed limb-scan profiles of dayglow emissions. The observed N2 Lyman-Birge-Hopfield (LBH) emission reflects a vibrational population distribution in the a(1 Pi)(sub g) state that differs significantly from those predicted for direct electron excitation and excitation with cascade from the a('1 Sigma)(sub u)(-) and w(1 Delta)(sub u) states. The vibrational population distribution and LBH brightness suggest a total cascade rate 45% that of direct excitation, in contrast to laboratory measurements. For the first time, pronounced limb brightening is observed in both the N I lambda 1200 limb emission profiles, as expected for emissions excited by N2 dissociation which produces kinetically fast N fragments; however, optically thick components of these features are also observed. Preliminary modeling of the OI lambda 1356, HI lambda 1216, and OI lambda 1304 and OI lambda 1641 emissions agrees to within roughly 10% of the observed limb-scan profiles, but the models underestimate the N2 LBH profiles by a factor of 1.4-1.6, consistent with the inferred cascade effect. Other findings include: an OI lambda 1152/lambda 1356 intensity ratio that is inconsistent with the large cascade contribution to OI lambda 1356 from np 5P states required by laboratory and nightglow observations; nightglow observations of the tropical ultraviolet arcs exhibit a wide range of OI lambda 1356/lambda 1304 intensity ratios and illustrate the complicated observing geometry and radiative transfer effects that must be modeled; and we find a 3-sigma upper limit of 8.5 R to the total LBH vehicle glow emission.

Budzien, S. A.↗

Viscous compressible flow direct and inverse computation and illustrations

An algorithm for laminar and turbulent viscous compressible two dimensional flows is presented. For the application of precise boundary conditions over an arbitrary body surface, a body-fitted coordinate system is used in the physical plane. A thin-layer approximation of tne Navier-Stokes equations is introduced to keep the viscous terms relatively simple. The flow field computation is performed in the transformed plane. A factorized, implicit scheme is used to facilitate the computation. Sample calculations, for Couette flow, developing pipe flow, an isolated airflow, two dimensional compressor cascade flow, and segmental compressor blade design are presented. To a certain extent, the effective use of the direct solver depends on the user's skill in setting up the gridwork, the time step size and the choice of the artificial viscosity. The design feature of the algorithm, an iterative scheme to correct geometry for a specified surface pressure distribution, works well for subsonic flows. A more elaborate correction scheme is required in treating transonic flows where local shock waves may be involved.

Yang, T. T.↗

Distributed Exhaust Nozzles for Jet Noise Reduction

The main objective of this study is to validate the jet noise reduction potential of a concept associated with distributed exhaust nozzles. Under this concept the propulsive thrust is generated by a larger number of discrete plumes issuing from an array of small or mini-nozzles. The potential of noise reduction of this concept stems from the fact that a large number of small jets will produce very high frequency noise and also, if spaced suitably, they will coalesce at a smaller velocity to produce low amplitude, low frequency noise. This is accomplished through detailed acoustic and fluid measurements along with a Computational Fluidic Dynamic (CFD) solution of the mean (DE) Distributed Exhaust nozzle flowfield performed by Northrop-Grumman. The acoustic performance is quantified in an anechoic chamber. Farfield acoustic data is acquired for a DE nozzle as well as a round nozzle of the same area. Both these types of nozzles are assessed numerically using Computational Fluid Dynamic (CFD) techniques. The CFD analysis ensures that both nozzles issued the same amount of airflow for a given nozzle pressure ratio. Data at a variety of nozzle pressure ratios are acquired at a range of polar and azimuthal angles. Flow visualization of the DE nozzle is used to assess the fluid dynamics of the small jet interactions. Results show that at high subsonic jet velocities, the DE nozzle shifts its frequency of peak amplitude to a higher frequency relative to a round nozzle of equivalent area (from a S(sub tD) = 0.24 to 1. 3). Furthermore, the DE nozzle shows reduced sound pressure levels (as much as 4 - 8 dB) in the low frequency part of the spectrum (less than S(sub tD) = 0.24 ) compared to the round nozzle. At supersonic jet velocities, the DE nozzle does not exhibit the jet screech and the shock-associated broadband noise is reduced by as much as 12 dB.

Ahuja, K. K.↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

ALESEP: A computer program for the analysis of airfoil leading edge separation bubbles

The ALESEP program for the analysis of the inviscid/viscous interaction which occurs due to the presence of a closed laminar transitional separation bubble on an airflow is presented. The ALESEP code provides a iterative solution of the boundary layer equations expressed in an inverse formulation coupled to a Cauchy integral representation of the inviscid flow. This interaction analysis is treated as a local perturbation to a known solution obtained from a global airfoil analysis. Part of the required input to the ALESEP code are the reference displacement thickness and tangential velocity distributions. Special windward differencing may be used in the reversed flow regions of the separation bubble to accurately account for the flow direction in the discretization of the streamwise convection of momentum. The ALESEP code contains a forced transition model based on a streamwise intermittency function and a natural transition model based on a solution of the integral form of the turbulent kinetic energy equation. Instructions for the input/output, and program usage are presented.

Davis, R. L.↗

Grid Interactive Micro-Distributed Refrigerated Display Case

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Towards replacing physical testing of granular materials with a Topology-based Model

In the study of packed granular materials, the performance of a sample (e.g., the detonation of a high-energy explosive) often correlates to measurements of a fluid flowing through it. The “effective surface area,” the surface area accessible to the airflow, is typically measured using a permeametry apparatus that relates the flow conductance to the permeable surface area via the Carman-Kozeny equation. This equation allows calculating the flow rate of a fluid flowing through the granules packed in the sample for a given pressure drop. However, Carman-Kozeny makes inherent assumptions about tunnel shapes and flow paths that may not accurately hold in situations where the particles possess a wide distribution in shapes, sizes, and aspect ratios, as is true with many powdered systems of technological and commercial interest. To address this challenge, we replicate these measurements virtually on micro-CT images of the powdered material, introducing a new Pore Network Model based on the skeleton of the Morse-Smale complex. Pores are identified as basins of the complex, their incidence encodes adjacency, and the conductivity of the capillary between them is computed from the cross-section at their interface. We build and solve a resistive network to compute an approximate laminar fluid flow through the pore structure. Here, we provide two means of estimating flow-permeable surface area: (i) by direct computation of conductivity, and (ii) by identifying dead-ends in the flow coupled with isosurface extraction and the application of the Carman-Kozeny equation, with the aim of establishing consistency over a range of particle shapes, sizes, porosity levels, and void distribution patterns.

36 MATERIALS SCIENCE↗

A supersonic fan equipped variable cycle engine for a Mach 2.7 supersonic transport

The concept of a variable cycle turbofan engine with an axially supersonic fan stage as powerplant for a Mach 2.7 supersonic transport was evaluated. Quantitative cycle analysis was used to assess the effects of the fan inlet and blading efficiencies on engine performance. Thrust levels predicted by cycle analysis are shown to match the thrust requirements of a representative aircraft. Fan inlet geometry is discussed and it is shown that a fixed geometry conical spike will provide sufficient airflow throughout the operating regime. The supersonic fan considered consists of a single stage comprising a rotor and stator. The concept is similar in principle to a supersonic compressor, but differs by having a stator which removes swirl from the flow without producing a net rise in static pressure. Operating conditions peculiar to the axially supersonic fan are discussed. Geometry of rotor and stator cascades are presented which utilize a supersonic vortex flow distribution. Results of a 2-D CFD flow analysis of these cascades are presented. A simple estimate of passage losses was made using empirical methods.

Tavares, T. S.↗

Overexpanded Performance of Conical Nozzles with Area Ratios of 6 and 9 With and Without Supersonic External Flow

An investigation of the thrust characteristics and internal pressure distributions of two convergent-divergent 15 deg. half-angle exhaust nozzles having area ratios of 6 and 9 was made in the NASA Lewis 10- by 10-foot supersonic wind tunnel. The tests were conducted at free-stream Mach numbers of 0, 2.0, 2.5, 3.0, and 3.5 over a range of nozzle pressure ratios from 3 to 105. Attempts were made to induce separation of the overexpanded nozzle flow using secondary airflow and a wedge. Nozzle flow expansion under all free-stream conditions followed one-dimensional theory until separation from the nozzle wall occurred. In quiescent air the nozzle flow expanded to a pressure approximately one-half the base pressure before separation. When the nozzles were tested with supersonic external flow at the same effective pressure ratios, the nozzle flow separated with negligible expansion below the base pressure. The effect of a supersonic stream on internal nozzle flow separation characteristics was well defined only at a free-stream Mach number of 2.0. Thrust data at supersonic free-stream conditions indicate that only a small percentage of the ideal nozzle thrust will be available at nozzle pressure ratios below design. However, the overexpanded primary nozzle thrust loss was decreased by injecting large quantities of secondary air near the nozzle exit. In most cases no net gain in thrust resulted from secondary-air injection when the nozzle thrust was compared with the ideal thrust of both the primary and secondary airflows.

Musial, Norman T.↗

Investigations of detail design issues for the high speed acoustic wind tunnel using a 60th scale model tunnel. Part 1: Tests with open circuits

This report summarizes the tests on the 1:60 scale model of the High Speed Acoustic Wind Tunnel (HSAWT) performed during the period of November 1989 to December 1990. Throughout the testing the tunnel was operated in the 'open circuit mode', that is when the airflow was induced by a powerful exhaust fan located outside the tunnel circuit. The tests were first performed with the closed test section and were subsequently repeated with the open test section. While operating with the open test section, a novel device, called the 'nozzle-diffuser,' was also tested in order to establish its usefulness of increasing pressure recovery in the first diffuser. The tests established the viability of the tunnel design. The flow distribution in each tunnel component was found acceptable and pressure recovery in the diffusers were found satisfactory. The diffusers appeared to operate without flow separation. All tests were performed at NASA LaRC.

Barna, P. Stephen↗

Coupled Model Simulation of Snowfall Events Over the Black Hills

Although many long-term simulations of snow accumulation and oblation have been made using stand-alone land surface models and surface models coupled with GCMs, less research has focused on short-term event simulations. Actually, accurate event simulations of snow-related processes are the basis for successful long-term simulation. Three advantages of event simulations of snowfall and snow melting are availability of: (1) intensive observation data from field experiments for validation; (2) more physically-realistic precipitation schemes for use in atmospheric models to simulate snowfall; and (3) a more detailed analysis of the snow melting processes. In addition to the complexities of snow related processes themselves, terrain-induced effects on snowfall/snow melting make simulations of snow events more difficult. Climatological observations indicate that terrain features such as the Black Hills of South Dakota and Wyoming can exert important effects on snow accumulation and snow oblation processes. One of the primary effects is that the orography causes forced uplift of airflow and causes atmospheric waves to form both upwind and downwind of it. Airflow often splits around the obstacle, converging on the lee side. This convergence may lead to precipitation enhancement. It also provides an elevated heat and moisture source that enhances atmospheric instability. During the period of April 5-May 5, 1999, the Upper Missouri River Basin Pilot Project (UMRBPP) made intensive observations on precipitation events occurring in the Black Hills. Two moderate snowfall events were captured during the period. The resulting high temporal and spatial resolution data provides opportunities to investigate terrain effects on snowfall amount, distribution, and melting. Successful simulation of snowfall amount, distribution, and evolution using atmospheric models is important to subsequent modeling of snow melting using snow sub-models in land surface schemes. In this paper, a coupled model system, consisting of an atmosphere model (ARPS) and a land-surface model (revised NCAR LSM), is used to simulate one of these UMRBPP cases.

Wang, Jianzhong↗

Luminescent barometry in wind tunnels

A flexible and relatively inexpensive method and apparatus are described for continuous pressure mapping of aerodynamic surfaces using photoluminescence and imaging techniques. Platinum octaethylporphyrin (PtOEP) has a phosphorescence known to be quenched by oxygen. When dissolved in a silicone matrix, PtOEP may be distributed over a surface as a thin, uniform film. When the film is irradiated with ultraviolet light, the luminescence intensity provides a readily detectable, qualitative surface flow visualization. Moreover, since the luminescence intensity is found to be inversely proportional to the partial pressure of oxygen, a quantitative measure of pressure change may be obtained using a silicon target vidicon or a charge-coupled device video sensor to measure intensity. Luminescent images are captured by a commercial frame buffer board. Images taken in wind tunnels during airflow are ratioed to images taken under ambient 'wind-off' conditions. The resulting intensity ratio information is converted to pressure using calibration curves of I0/I vs p/p0, where I0 is the intensity at ambient pressure p0 and I is the intensity at any other pressure p.

Kavandi, Janet↗