Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Wind Energy System Time-domain (WEST) analyzers using hybrid simulation techniques

Two stand-alone analyzers constructed for real time simulation of the complex dynamic characteristics of horizontal-axis wind energy systems are described. Mathematical models for an aeroelastic rotor, including nonlinear aerodynamic and elastic loads, are implemented with high speed digital and analog circuitry. Models for elastic supports, a power train, a control system, and a rotor gimbal system are also included. Limited correlation efforts show good comparisons between results produced by the analyzers and results produced by a large digital simulation. The digital simulation results correlate well with test data.

Hoffman, J. A.↗

A network of automatic atmospherics analyzer

The design and function of an atmospheric analyzer which uses a computer are discussed. Mathematical models which show the method of measurement are presented. The data analysis and recording procedures of the analyzer are discussed.

Schaefer, J.↗

System design for a million channel digital spectrum analyzer /MCSA/

The system design of a wideband (8 MHz) million-channel digital spectrum analyzer for use with a SETI receiver is presented. The analyzer makes use of a digital bandpass filter bank for transforming the wideband input signal into a specified number (120) of uniform narrowband output channels by the use of a Fourier transform digital processor combined with a prototype digital weighting network (finite impulse response filter). The output is then processed separately by 120 microprocessor-based discrete Fourier transform computers, each producing 8190 output channels of approximately 8 Hz bandwidth by the use of an 8190-point prime factor algorithm.

Peterson, A.↗

The integrated optic RF spectrum analyzer

The results of measurements made on a fully integrated optic RF spectrum analyzer (IOSA) are reported. The performance of the device acousto-optic bandwidth, single-tone RF resolution, two-tone RF resolution, single-tone dynamic range, two-tone dynamic range, and single-tone RF response are presented. The device parameters that control device performance are analyzed. These results demonstrate the viability of the IOSA for real time spectrum analysis of pulsed and CW RF signals. Improvements of RF bandwidth resolution can be obtained by the use of larger collimated optical beams which requires larger optical lens elements, and hence, larger crystals.

Pedinoff, M. E.↗

User's guide to noise data acquisition and analysis programs for HP9845: Nicolet analyzers

A software interface package was written for use with a desktop computer and two models of single channel Fast Fourier analyzers. This software features a portable measurement and analysis system with several options. Two types of interface hardware can alternately be used in conjunction with the software. Either an IEEE-488 Bus interface or a 16-bit parallel system may be used. Two types of storage medium, either tape cartridge or floppy disc can be used with the software. Five types of data may be stored, plotted, and/or printed. The data types include time histories, narrow band power spectra, and narrow band, one-third octave band, or octave band sound pressure level. The data acquisition programming includes a front panel remote control option for the FFT analyzers. Data analysis options include choice of line type and pen color for plotting.

Mcgary, M. C.↗

Wind energy system time-domain (WEST) analyzers

A portable analyzer which simulates in real time the complex nonlinear dynamics of horizontal axis wind energy systems was constructed. Math models for an aeroelastic rotor featuring nonlinear aerodynamic and inertial terms were implemented with high speed digital controllers and analog calculation. This model was combined with other math models of elastic supports, control systems, a power train and gimballed rotor kinematics. A stroboscopic display system graphically depicting distributed blade loads, motion, and other aerodynamic functions on a cathode ray tube is included. Limited correlation efforts showed good comparison between the results of this analyzer and other sophisticated digital simulations. The digital simulation results were successfully correlated with test data.

Dreier, M. E.↗

Pioneer 10/11 data analysis of the plasma analyzer experiment

The Pioneer 10 plasma analyzer detected the 10 plasma torus. Evidence was found of corotating ions which appear to be primarily S (++) and O (++) in the Pioneer 10 plasma data as the spacecraft moved inward from 6.9 to 5.4 R sub J. The Pioneer plasma analyzer was effective in obtaining information on the heavy ion populations in the Jovian magnetosphere. Interplanetary solar wind plasma shocks can trap energetic particles (cosmic rays) for weeks and out to distances of 17 AU. Energetic particles (o.5 MeV to 20 MeV) were confined between two plasma shocks from solar flares as the shocks propagated outward in the solar system.

Intriligator, D. S.↗

Automated analyzer for aircraft measurements of atmospheric methane and total hydrocarbons

An automated methane/total hydrocarbon analyzer is presented, which can produce alternate methane/total hydrocarbon measurements every 7 seconds to provide the spatial resolution required for regional hydrocarbon measurements at aircraft speeds. The construction and sampling techniques developed for the aircraft mounted system are discussed. A technique to periodically measure atmosphere oxygen is incorporated into the analyzer to ensure accurate hydrocarbon measurements, and a data collection methodology is developed to minimize errors resulting from changes in flame ionization detector sensitivity at different altitudes. Aircraft data acquired at the 1979 Southeastern Virginia Urban Plume Study are also presented, which illustrate the application of the instrument to a troposphere pollution plume.

Cofer, W. R., III↗

Thermal Radiation Analyzer System

Thermal Radiation Analyzer System, TRASYS/II, is computer software system with generalized capability to solve radiation-related aspects of thermal-analysis problems. When used in conjunction with generalized thermalanalysis program, such as Systems Improved Numerical Differencing Analyzer (SINDA) program, any thermal problem expressed in terms of lumped-parameter RC thermal network solved.

Skladany, J.↗

A revised version of the transfer matrix method to analyze one-dimensional structures

A new and general method to analyze both free and forced vibration characteristics of one-dimensional structures is discussed in this paper. This scheme links for the first time the classical transfer matrix method with the recently developed integrating matrix technique to integrate systems of differential equations. Two alternative approaches to the problem are presented. The first is based upon the lumped parameter model to account for the inertia properties of the structure. The second releases that constraint allowing a more precise description of the physical system. The free vibration of a straight uniform beam under different support conditions is analyzed to test the accuracy of the two models. Finally some results for the free vibration of a 12th order system representing a curved, rotating beam prove that the present method is conveniently extended to more complicated structural dynamics problems.

Nitzsche, F.↗

Thermal Radiation Analyzer

Thermal Radiation Analyzer System TRASYS II solves radiation related aspects of thermal analysis problems. TRASYS II provides for calculation of internode radiation interchange data and for calculation of incident and absorbed heat rate data originating from environmental radiant heat sources. When TRASYS II used in conjunction with generalized thermal analysis program such as Systems Improved Numerical Differencing Analyzer (SINDA), any thermal problem expressed in terms of lumped parameter RC thermal network solved.

Vogt, R. A.↗

A portable x-ray analyzer for wearmetal particles in lubricants

An extensive program exists for the systematic sampling and analysis of lubricants in U.S. Air Force aircraft engines. The sudden development of excessive engine wear can usually be detected on the basis of monitoring the concentration of several key metallic elements for each aircraft engine. In many cases even the specific fault within an engine can be recognized. The two types of equipment which are currently being employed for the conduction of oil analyses make use of atomic emission or atomic absorption spectroscopy. In both cases, heavy, large, and relatively fragile pieces of equipment are involved. Difficulties concerning the transportation of these devices have led to the development of a small, sturdy, and easily portable wearmetal analyzer. The analyzer makes use of an X-ray fluorescence technique.

Clark, B. C.↗

The Statistical Loop Analyzer (SLA)

The statistical loop analyzer (SLA) is designed to automatically measure the acquisition, tracking and frequency stability performance characteristics of symbol synchronizers, code synchronizers, carrier tracking loops, and coherent transponders. Automated phase lock and system level tests can also be made using the SLA. Standard baseband, carrier and spread spectrum modulation techniques can be accomodated. Through the SLA's phase error jitter and cycle slip measurements the acquisition and tracking thresholds of the unit under test are determined; any false phase and frequency lock events are statistically analyzed and reported in the SLA output in probabilistic terms. Automated signal drop out tests can be performed in order to trouble shoot algorithms and evaluate the reacquisition statistics of the unit under test. Cycle slip rates and cycle slip probabilities can be measured using the SLA. These measurements, combined with bit error probability measurements, are all that are needed to fully characterize the acquisition and tracking performance of a digital communication system.

Lindsey, W. C.↗

Numerical methods for analyzing electromagnetic scattering

Numerical methods to analyze electromagnetic scattering are presented. The dispersions and attenuations of the normal modes in a circular waveguide coated with lossy material were completely analyzed. The radar cross section (RCS) from a circular waveguide coated with lossy material was calculated. The following is observed: (1) the interior irradiation contributes to the RCS much more than does the rim diffraction; (2) at low frequency, the RCS from the circular waveguide terminated by a perfect electric conductor (PEC) can be reduced more than 13 dB down with a coating thickness less than 1% of the radius using the best lossy material available in a 6 radius-long cylinder; (3) at high frequency, a modal separation between the highly attenuated and the lowly attenuated modes is evident if the coating material is too lossy, however, a large RCS reduction can be achieved for a small incident angle with a thin layer of coating. It is found that the waveguide coated with a lossy magnetic material can be used as a substitute for a corrugated waveguide to produce a circularly polarized radiation yield.

Lee, S. W.↗

Response characteristics of laser diffraction particle size analyzers - Optical sample volume extent and lens effects

The response characteristics of laser diffraction particle sizing instruments were studied theoretically and experimentally. In particular, the extent of optical sample volume and the effects of receiving lens properties were investigated in detail. The experimental work was performed with a particle size analyzer using a calibration reticle containing a two-dimensional array of opaque circular disks on a glass substrate. The calibration slide simulated the forward-scattering characteristics of a Rosin-Rammler droplet size distribution. The reticle was analyzed with collection lenses of 63 mm, 100 mm, and 300 mm focal lengths using scattering inversion software that determined best-fit Rosin-Rammler size distribution parameters. The data differed from the predicted response for the reticle by about 10 percent. A set of calibration factor for the detector elements was determined that corrected for the nonideal response of the instrument. The response of the instrument was also measured as a function of reticle position, and the results confirmed a theoretical optical sample volume model presented here.

Hirleman, E. D.↗

The Medium-energy particle analyzer (MEPA) on the AMPTE CCE spacecraft

A major objective in the design of the Charge Composition Explorer (CCE) is related to the measurement of small fluxes of ions (lithium and barium) injected in the solar wind and the deep magnetotail. A second important objective is concerned with the comprehensive measurement of the composition and dynamics of the natural-particle population. The medium-energy particle analyzer (MEPA) in the CCE is designed to cover an energy range which is normally covered by electrostatic analyzers. In order to prevent saturation by the large magnetospheric fluxes of low-energy protons, the MEPA sensor was designed to have a low efficiency for protons, but a high efficiency for the rarer heavier nuclei. The considered aims could be achieved by developing a technology, new to space flight, for measuring energetic ion composition. Particle mass is determined on the basis of the measurement of particle time of flight and total energy.

Mcentire, R. W.↗

A wide-band, high-resolution spectrum analyzer

A million-channel, 20 MHz-bandwidth, digital spectrum analyzer under evelopment for use in the SETI Sky Survey and other applications in the Deep Space Network is described. The analyzer digitizes an analog input, performs a 2(20)-point Radix-2, Fast Fourier Transform, accumulates the output power, and normalizes the output to remove frequency-dependent gain. The effective speed of the real-time hardware is 2.2 GigaFLOPS.

Wilck, H. C.↗