Search NASA⌕ Search

SEARCH · Search NASA

Results for “Angular dependence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Directional dependence of equilibrated TLD-400 chips in multiple radiation fields

Fielding of thermoluminescent dosimeters (TLDs) for measurement of photon radiation dose in experiments is the standard practice for γ-irradiation facilities, pulsed power x-ray facilities, and reactor facilities at Sandia National Laboratories (SNL). Due to the high-dose experimental conditions and the mixed ( 1 n, γ) fields in these facilities, SNL radiation metrologists have historically used CaF 2 :Mn TLDs (also known as TLD-400). Recent inquiries to the radiation metrology staff have raised concerns that the aluminum-equilibrated TLD-400 chips may exhibit a directionally dependent response. The metrologists were asked whether the dose measured by the chip may be impacted by the angle of incidence on the equilibrated TLD. To provide a thorough answer to this query, a set of adjoint Monte Carlo radiation transport calculations was performed for three different equilibrated TLDs as well as bare TLD chips using the Integrated Tiger Series (ITS) code. The key feature of the adjoint calculations performed in this study is that each photon escaping the modeled geometry was tallied into angular bins to provide information on both the energy and angular dependence of the equilibrated chip. After the adjoint Monte Carlo calculations were completed, the resulting energy-dependent response function for each angular bin was convolved with multiple photon energy spectra representing various radiation facilities at SNL. The radiation facilities selected for analysis span a range of photon energies from approximately 1 keV up to approximately 20 MeV. Thus, the presented results are applicable to a wide variety of radiation facilities around the world. Although the bare TLD-400 chip was expected to display the largest variation due to the photon angle of impact on the dosimeter, the dosimeter with the thinnest aluminum equilibrator (SNL thin equilibrated TLD-400) was determined to have the biggest differential between the impact angle with the maximum dose ( D max ) and the impact angle with the minimum dose ( D min ). However, the SNL normal equilibrated TLD-400 chip demonstrated a dramatic reduction in that differential between maximum and minimum dose angles. The reduction in this differential is one of the dominant factors in experimenters’ choice to field these dosimeters at SNL radiation facilities. The results from the PNNL (Hanford) energy-flattening field capsule are consistent with the previous publications. The differential dose responses due to the photon impact angle indicate that experimenters should strive to field their TLD-400 dosimeters in a consistent manner to avoid additional uncertainty in the measurements based on dosimeter orientation.

Adjoint radiation transport↗

A novel method to measure ion density in ICF experiments using x-ray spectroscopy of cylindrical tracers

The indirect drive approach to inertial confinement fusion has undergone important advances in the past few years. Improvements in temperature and density diagnostic methods are leading to more accurate measurements of the plasma conditions inside the Hohlraum and therefore to more efficient experimental designs. The implementation of dot spectroscopy has proven to be a versatile approach to extracting space- and time-dependent electron temperatures. In this method, a microdot of a mid-Z material is placed inside the Hohlraum and its K-shell emission spectrum is used to determine the plasma temperature. However, radiation transport of optically thick lines acting within the cylindrical dot geometry influences the outgoing spectral distribution in a manner that depends on the viewing angle. This angular dependence has recently been studied in the high energy density regime at the OMEGA laser facility, which allowed us to design and benchmark appropriate radiative transfer models that can replicate these geometric effects. By combining these models with the measurements from the dot spectroscopy experiments at the National Ignition Facility, we demonstrate here a novel technique that exploits the transport effects to obtain time-resolved measurements of the ion density of the tracer dots, without the need for additional diagnostics. Furthermore, we find excellent agreement between experiment and simulation, opening the possibility of using these geometric effects as a density diagnostic in future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of gravity opientation on the thermal performance of Stirling-type pulse tube cryocoolers

This paper extends the investigation of angular orientation effects to the refrigeration performance of high frequency (-40 Hz) Stirling-type pulse tube cryocoolers typical of those used in long-life space applications. Strong orientation effects on the performance of such cryocoolers have recently been observed during system-level testing of both linear and U-tube type pulse tubes. To quantify the angular dependency effects, data have been gathered on both U-tube and linear type pulse tubes of two different manufacturers as a function of orientation angle, cold-tip temperature, and compressor stroke.

angular dependency↗

New insights gained on mechanisms of low-energy proton-induced SEUs by minimizing energy straggle

In this study, we present low-energy proton single-event upset (SEU) data on a 65 nm SOI SRAM whose substrate has been completely removed. Since the protons only had to penetrate a very thin buried oxide layer, these measurements were affected by far less energy loss, energy straggle, flux attrition, and angular scattering than previous datasets. The minimization of these common sources of experimental interference allows more direct interpretation of the data and deeper insight into SEU mechanisms. The results show a strong angular dependence, demonstrate that energy straggle, flux attrition, and angular scattering affect the measured SEU cross sections, and prove that proton direct ionization is the dominant mechanism for low-energy proton-induced SEUs in these circuits.

74 ATOMIC AND MOLECULAR PHYSICS↗

Performance of absorptive liners in the presence of spinning modes.

Results of free field measurements of the absorption coefficient of fiberglass, which indicate that the material has a high coefficient over a broad frequency range with little angular dependence. This material is also a very effective duct liner and attenuates spinning modes more rapidly than plane waves. The resonant absorber tested exhibits a strong angular and frequency dependence of the absorption coefficient, is only a moderately effective duct liner for spinning modes, and produces no measurable attenuation for plane waves.

Mcdaniel, O. H.↗

Time-dependent hydrodynamic phenomena in the envelopes of the Be stars

Temporal and angular variations in the motion and distribution of circumstellar material about Be stars are studied by means of a simple hydrodynamical approach. The flow variables are each written as the sum of a known, steady-state axisymmetric term and a smaller component which contains both temporal and angular dependence. Substitution of these dichotomous expressions for the flow variables into Euler's equation and the continuity equation leads to a set of linearized equations for the terms which depend on time and angle. Solutions can be found to a somewhat approximated version of the linearized equations, and these solutions explain the qualitative features of the observed short-time variations.

Morgan, T. H.↗

Self-induced spin-orbit torques in metallic ferromagnets

Herein we present a phenomenological theory of spin-orbit torques in a metallic ferromagnet with spin-relaxing boundaries. The model is rooted in the coupled diffusion of charge and spin in the bulk of the ferromagnet, where we account for the anomalous Hall effects as well as the anisotropic magnetoresistance in the corresponding constitutive relations for both charge and spin sectors. The diffusion equations are supplemented with suitable boundary conditions reflecting the spin-sink capacity of the environment. In inversion-asymmetric heterostructures, the uncompensated spin accumulation exerts a dissipative torque on the order parameter, giving rise to a current-dependent linewidth in the ferromagnetic resonance with a characteristic angular dependence. We compare our model to recent spin-torque ferromagnetic resonance measurements, illustrating how rich self-induced spin-torque phenomenology can arise even in simple magnetic structures.

36 MATERIALS SCIENCE↗

SU-F-T-322: A Comparison of Two Si Detectors for in Vivo Dosimetry

Purpose: To compare two types of semiconductor detectors for in vivo dosimetry by their dependence from various parameters in different conditions. Methods: QED yellow (Sun Nuclear) and EDP (Scanditronix) Si detectors were radiated by a Varian Clinac 2300 ix with 6 and 18 MV energies. 10 cm thickness water equivalent phantom consisted of 30×30 cm{sup 2} squared plates was used for experiments. Dose dependencies for different beam angles (0 – 180°), field size (3–40 cm), dose (50 – 300 MU), and dose rates (50 – 300 MU/min) were obtained and calibrated with Standard Farmer chamber (PTW). Results: Reproducibility, linearity, dose rate, angular dependence, and field size dependence were obtained for QED and EDP. They show no dose-rate dependence in available clinical dose rate range (100–600 MU/min). Both diodes have linear dependence with increasing the dose. Therefore even in case of high radiation therapy (including total body irradiation) it is not necessary to apply an additional correction during in vivo dosimetry. The diodes have different behavior for angular and field size dependencies. QED diode showed that dose value is stable for beam angles from 0 to 60°, for 60–180° correction factor has to be applied for each beam angle during in vivo measurements. For EDP diode dose value is sensitive to beam angle in whole range of angles. Conclusion: The study shows that QED diode is more suitable for in vivo dosimetry due to dose value independence from incident beam angle in the range 0–60°. There is no need in correction factors for increasing of dose and dose rate for both diodes. The next step will be to carry out measurements in non-standard conditions of total body irradiation. After this modeling of these experiments with Monte Carlo simulation for comparison calculated and obtained data is planned.

60 APPLIED LIFE SCIENCES↗

Development and assessment of hierarchical multi-reward reinforcement learning based potential for silicene with state-of-the-art models

We develop a new interatomic force field for Silicene, a 2D material with a buckled hexagonal lattice structure with high polymorphism. We introduce new parameterizations of a Tersoff model using a hierarchical multi-reward reinforcement learning (RL) methodology coupled with a continuous Monte Carlo Tree Search optimization. Our model significantly outperforms existing methods by enhancing the accuracy of predictions for the structural and thermodynamic properties of seven silicene polymorphs-including structure, energy, equation of state, elasticity, and phonon dispersion-when compared to established models. We further make a comprehensive comparison of the various models in predicting the mechanical and thermal properties of silicene. We trace the origin of the improved performance to the description of the angular dependence in the bond-order term, suggesting that modifying the angular terms in short-range models is essential to capture the structural diversity in low dimensional systems.

2D materials↗

Reconstruction of the complex angle-dependent photoionization transition dipole from a laser-dressed streaking experiment

We study the retrieval of the angular dependence of the photoionization transition dipole phase of an attosecond XUV pulse in order to reconstruct the whole photoelectron wave packet after the photoemission process. Using a one-electron model Ar atom, we show that the full electron wave packet can be reconstructed from IR-free photoelectron angular distributions and the streaking electron spectra in an IR-dressed XUV photoionization, with photoelectrons along the common polarization direction of the two pulses. The method relies on the validity of the strong-field approximation so it is valid only for higher energy photoelectrons. Here, we also point out that a single photoionization group time delay is not enough to represent a photoemission process; instead, a complete characterization of the electron wave packet requires the retrieval of the spectral phase over the whole bandwidth of the wave packet.

74 ATOMIC AND MOLECULAR PHYSICS↗

Acceleration and evolution of a hollow electron beam in wakefields driven by a Laguerre-Gaussian laser pulse

We show that a ring-shaped hollow electron beam can be injected and accelerated by using a Laguerre-Gaussian laser pulse and ionization-induced injection in a laser wakefield accelerator. The acceleration and evolution of such a hollow, relativistic electron beam are investigated through three-dimensional particle-in-cell simulations. We find that both the ring size and the beam thickness oscillate during the acceleration. The beam azimuthal shape is angularly dependent and evolves during the acceleration. The beam ellipticity changes resulting from the electron angular momenta obtained from the drive laser pulse and the focusing forces from the wakefield. The dependence of beam ring radius on the laser-plasma parameters (e.g., laser intensity, focal size, and plasma density) is studied. Such a hollow electron beam may have potential applications for accelerating and collimating positively charged particles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SCEPTRE 2.2 Angular Quadrature Sets

This document includes details of the angular quadrature sets available in SCEPTRE for performing numerical integrations in the angular phase space. The angular dependence of the boundary and fixed-source terms an d initial angular flux are specified by angular index rather than by direction. It is, therefore, necessary to know the mapping from a specific direction to a direction index. This document includes angular quadrature weights and direction cosines for most of the quadrature sets available in SCEPTRE.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurements of angle-resolved reflectivity of PTFE in liquid xenon with IBEX

Abstract Liquid xenon particle detectors rely on excellent light collection efficiency for their performance. This depends on the high reflectivity of polytetrafluoroethylene (PTFE) at the xenon scintillation wavelength of 178 nm, but the angular dependence of this reflectivity is not well-understood. IBEX is designed to directly measure the angular distribution of xenon scintillation light reflected off PTFE in liquid xenon. These measurements are fully described by a microphysical reflectivity model with few free parameters. Dependence on PTFE type, surface finish, xenon pressure, and wavelength of incident light is explored. Total internal reflection is observed, which results in the dominance of specular over diffuse reflection and a reflectivity near 100% for high angles of incidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Angular distribution of 𝛾 rays from a neutron-induced 𝑝-wave resonance of 132 Xe

A neutron-energy dependent angular distribution was measured for individual 𝛾 rays from the 3.2 eV 𝑝-wave resonance of 131 Xe+⁢𝑛, that shows enhanced parity violation owing to a mixing between 𝑠- and 𝑝-wave amplitudes. The 𝛾-ray transitions from the 𝑝-wave resonance were identified, and the angular distribution with respect to the neutron momentum was evaluated as a function of the neutron energy for 7132 keV 𝛾 rays, which correspond to a transition to the 1807 keV excited state of 132 Xe. The angular distribution is considered to originate from the interference between 𝑠- and 𝑝-wave amplitudes, and will provide a basis for a quantitative understanding of the enhancement mechanism of the fundamental parity violation in compound nuclei.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bulk photovoltaic effect in hexagonal LuMnO 3 single crystals

Hexagonal manganites, such as h-LuMnO 3 , are ferroelectric and have a narrow electronic band gap of ≈1.5eV. Here we report on the photoresponse of h-LuMnO 3 single crystals. It is found that the short circuit photocurrent density (J sc ) and the open circuit voltage (V oc ) are dependent on the direction of the polarization plane of a linearly polarized impinging light. Its angular dependence indicates the contribution of bulk photovoltaic effect to the short circuit photocurrent (J BPE ). It is also observed that a switchable drift photocurrent, originating from the depoling field of the ferroelectric and thus tunable(<10%) by its polarization direction, also contributes to J sc . Although its presence precludes accurate determination of the bulk photovoltaic tensor elements and Glass coefficients, some bounds can be established. The Glass coefficients are found to be significantly larger than those obtained in BiFeO 3 . We argue that the smaller band gap of h-LuMnO 3 , its distinctive bipyramidal crystal field, and electronic configuration (3d 4 vs 3d 5 ), account for the difference and suggest a path towards ferroelectrics of higher photoconversion efficiency.

14 SOLAR ENERGY↗

Multiangle Implementation of Atmospheric Correction (MAIAC):: Radiative Transfer Basis and Look-up Tables - 1

This paper describes a radiative transfer basis of the algorithm MAIAC which performs simultaneous retrievals of atmospheric aerosol and bidirectional surface reflectance from the Moderate Resolution Imaging Spectroradiometer (MODIS). The retrievals are based on an accurate semianalytical solution for the top-of-atmosphere reflectance expressed as an explicit function of three parameters of the Ross-Thick Li-Sparse model of surface bidirectional reflectance. This solution depends on certain functions of atmospheric properties and geometry which are precomputed in the look-up table (LUT). This paper further considers correction of the LUT functions for variations of surface pressure/height and of atmospheric water vapor, which is a common task in the operational remote sensing. It introduces a new analytical method for the water vapor correction of the multiple ]scattering path radiance. It also summarizes the few basic principles that provide a high efficiency and accuracy of the LUT ]based radiative transfer for the aerosol/surface retrievals and optimize the size of LUT. For example, the single-scattering path radiance is calculated analytically for a given surface pressure and atmospheric water vapor. The same is true for the direct surface-reflected radiance, which along with the single-scattering path radiance largely defines the angular dependence of measurements. For these calculations, the aerosol phase functions and kernels of the surface bidirectional reflectance model are precalculated at a high angular resolution. The other radiative transfer functions depend rather smoothly on angles because of multiple scattering and can be calculated at coarser angular resolution to reduce the LUT size. At the same time, this resolution should be high enough to use the nearest neighbor geometry angles to avoid costly three ]dimensional interpolation. The pressure correction is implemented via linear interpolation between two LUTs computed for the standard and reduced pressure levels. A linear mixture and a modified linear mixture methods are used to represent different aerosol types in the aerosol/surface retrievals from several base models of the fine and coarse aerosol fractions. In summary, the developed LUT algorithm allows fast high-accuracy simulations of the outgoing radiance with full variability of the atmospheric and surface bidirectional reflectance properties for the aerosol/surface remote sensing.

Lyapustin, Alexei↗

Insights into the Mechanism of Chiral‐Induced Spin Selectivity: The Effect of Magnetic Field Direction and Temperature

Chiral oligopeptide monolayers are adsorbed on a ferromagnetic surface and their magnetoresistance is measured as a function of the angle between the magnetization of the ferromagnet and the surface normal. These measurements are conducted as a function of temperature for both enantiomers. The angle dependence is found to follow a changing trend with a period of 360°. Quantum simulations reveal that the angular distribution can be obtained only if the monolayer has significant effective spin orbit coupling (SOC), that includes contribution from the vibrations. The model shows that SOC only in the leads cannot reproduce the observed angular dependence. The simulation can reproduce the experiments if it included electron–phonon interactions and dissipation.

36 MATERIALS SCIENCE↗

Beam’s-eye-view imaging during non-coplanar lung SBRT

Purpose: Beam’s-eye-view (BEV) imaging with an electronic portal imaging device (EPID) can be performed during lung stereotactic body radiation therapy (SBRT) to monitor the tumor location in real-time. Image quality for each patient and treatment field depends on several factors including the patient anatomy and the gantry and couch angles. The authors investigated the angular dependence of automatic tumor localization during non-coplanar lung SBRT delivery. Methods: All images were acquired at a frame rate of 12 Hz with an amorphous silicon EPID. A previously validated markerless lung tumor localization algorithm was employed with manual localization as the reference. From ten SBRT patients, 12 987 image frames of 123 image sequences acquired at 48 different gantry–couch rotations were analyzed. δ was defined by the position difference of the automatic and manual localization. Results: Regardless of the couch angle, the best tracking performance was found in image sequences with a gantry angle within 20° of 250° (δ = 1.40 mm). Image sequences acquired with gantry angles of 150°, 210°, and 350° also led to good tracking performances with δ = 1.77–2.00 mm. Overall, the couch angle was not correlated with the tracking results. Among all the gantry–couch combinations, image sequences acquired at (θ = 30°, ϕ = 330°), (θ = 210°, ϕ = 10°), and (θ = 250°, ϕ = 30°) led to the best tracking results with δ = 1.19–1.82 mm. The worst performing combinations were (θ = 90° and 230°, ϕ = 10°) and (θ = 270°, ϕ = 30°) with δ > 3.5 mm. However, 35% (17/48) of the gantry–couch rotations demonstrated substantial variability in tracking performances between patients. For example, the field angle (θ = 70°, ϕ = 10°) was acquired for five patients. While the tracking errors were ≤1.98 mm for three patients, poor performance was found for the other two patients with δ ≥ 2.18 mm, leading to average tracking error of 2.70 mm. Only one image sequence was acquired for all other gantry–couch rotations (δ = 1.18–10.29 mm). Conclusions: Non-coplanar beams with gantry–couch rotation of (θ = 30°, ϕ = 330°), (θ = 210°, ϕ = 10°), and (θ = 250°, ϕ = 30°) have the highest accuracy for BEV lung tumor localization. Additionally, gantry angles of 150°, 210°, 250°, and 350° also offer good tracking performance. The beam geometries (θ = 90° and 230°, ϕ = 10°) and (θ = 270°, ϕ = 30°) are associated with substantial automatic localization errors. Overall, lung tumor visibility and tracking performance were patient dependent for a substantial number of the gantry–couch angle combinations studied.

60 APPLIED LIFE SCIENCES↗