Search NASA⌕ Search

SEARCH · Search NASA

Results for “Anode and cathode resistance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

113 records · Page 7

Temperature-dependent Battery Performance of a Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT Cathode and In-situ Heat Generation on Cycling

Excellent structural stability, high operating voltage, and high capacity have made Na 3 V 2 (PO 4 ) 2 F 3 a promising cathode material for sodium-ion batteries. However, high-temperature battery performances and heat generation measurements have not been systematically reported yet. Carbon-coated Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT (multi-walled carbon nanotube) samples are fabricated by a hydrothermal-assisted sol-gel method and the electrochemical performances are evaluated at three different temperatures (25, 45, and 55 °C). Furthermore, the well-crystallized Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT samples exhibit good cycling stability at both low and high temperatures; they deliver an initial discharge capacity of 120–125 mAhg -1 at a 1 C rate with a retention of 53 % capacity after 1,400 cycles with 99 % columbic efficiency. The half-cell delivers a capacity of 100 mAhg -1 even at a high rate of 10 C at room temperature. Furthermore, the Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT samples show good long-term durability; the capacity loss is an average of 0.05 % per cycle at a 1 C rate at 55 °C. Additionally, ionic diffusivity and charge transfer resistance are evaluated as functions of state of charge, and they explain the high electrochemical performance of the Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT samples. In-situ heat generation measurements reveal reversible results upon cycling owing to the high structural stability of the material. Excellent electrochemical performances are also demonstrated in the full-cell configuration with hard carbon as well as antimony Sb/C anodes.

25 ENERGY STORAGE↗

Electro-chemo-mechanically Driven Ni Exsolution from (Pr,Ce,Ni)O 2−δ : Controlled Nucleation Density and Enhanced Electrode Kinetics

In situ exsolution of metal nanoparticles is a promising strategy to prepare electrocatalysts with enhanced activity and resistance to agglomeration for efficient chemical transformations and energy conversion. Achieving a high nucleation density of nanoparticles under mild conditions and understanding how to tailor the process is important for performance of these electrodes in electrochemical cells. In this work, we demonstrate facile exsolution of Ni nanoparticles using fluorite-structured (Pr,Ce)O 2−δ as the support oxide, driven by electrochemical potential and aided by the metastability of Ni in the solid solution (elastic driving force). We prepare single-phase oriented thin films of (Pr,Ce,Ni)O 2−δ (NPCO) on (Zr,Y)O 2−δ (YSZ) substrates by pulsed laser deposition. With the aid of a high-throughput electrochemical cell that provides a lateral gradient in Nernst voltage, we apply in situ near-ambient pressure synchrotron X-ray photoelectron spectroscopy and ex situ atomic force microscopy to investigate the impact of electrochemical potential on Ni nucleation density. We find that metallic Ni can be successfully exsolved at 550 °C upon cathodic biasing in 20 mTorr O 2 , and its nucleation density increases with increasing electrochemical driving force/decreasing oxygen chemical potential. We further evaluate the electrochemical performance under highly reducing (fuel electrode) conditions by electrochemical impedance spectroscopy. With the exsolved Ni nanoparticles, the surface exchange coefficient of the NPCO is found to be ∼4× higher than for PCO without exsolution. This work confirms mixed conducting fluorites as beneficial host lattices for facile transition-metal exsolution and suggests the possibility for constructing an all ceria-based electrochemical cell with PCO serving as both the cathode and the anode.

36 MATERIALS SCIENCE↗

Characterization of the structure and chemistry of the solid–electrolyte interface by cryo-EM leads to high-performance solid-state Li-metal batteries

Solid-state lithium-metal (Li 0 ) batteries are gaining traction for electric vehicle applications because they replace flammable liquid electrolytes with a safer, solid-form electrolyte that also offers higher energy density and better resistance against Li dendrite formation. Solid polymer electrolytes (SPEs) are highly promising candidates because of their tunable mechanical properties and easy manufacturability; however, their electrochemical instability against lithium metal (Li 0 ), mediocre conductivity, and poorly understood Li 0 /SPE interphases have prevented extensive application in real batteries. In particular, the origin of the low Coulombic efficiency (CE) associated with SPEs remains elusive, as the debate continues as to whether it originates from unfavored interfacial reactions or lithium dendritic growth and dead lithium formation. In this work, we use state-of-the-art cryo-electromicroscopy (cryoEM) imaging and spectroscopic techniques to characterize the structure and chemistry of the interface between Li 0 and a polyacrylate-based SPE. Contradicting the conventional knowledge, we find that no protective interphase forms, owing to the sustained reactions between deposited Li dendrites and polyacrylic backbones and succinonitrile plasticizer. Due to the reaction induced volume change, large amounts of cracks form inside the Li dendrites with a stress corrosion-cracking behavior, indicating that Li0cannot be passivated in this SPE system. Based on this observation, we then introduce additive engineering leveraging on the knowledge of liquid electrolytes, and demonstrate that the Li 0 surface can be effectively protected against corrosion using fluoroethylene carbonate (FEC), leading to densely packed Li 0 domes with conformal and stable solid-electrolyte interphases (SEIs) films. Owing to the high room temperature ionic conductivity of 1.01 mS/cm -1 , the high transference number of 0.57 and the stabilized lithium electrolyte interface, this improved new SPE delivers an excellent lithium plating/stripping CE of 99% and 1800 hours of stable cycling in Li||Li symmetric cells (0.2 mA/cm -2 , 1mAh/cm -2 ). Furthermore, this improved cathodic stability along with the high anodic stability enables record high cycle life of >2000 cycles for Li||LiFePO 4 and >400 cycles for Li||LiCoO 2 full cells.

25 ENERGY STORAGE↗

Super p-sulfur cathodes for quasi-solid-state lithium-sulfur-batteries

Lithium-Sulfur (Li-S) batteries have become a promising candidate to meet the current energy storage demand, with its natural abundance of materials, high theoretical capacity of 1672 mAhg-1, high energy density of 2600 Whkg-1, low cost and lower environmental impact. Sulfide based solid state electrolytes (SSEs) have received greater attention due to their higher ionic conductivity, compatible interface with sulfur-based cathodes, and lower grain boundary resistance. However, the interface between SSEs and cathodes has become a challenge in all solid-state Li-S batteries due to the rigidity of the participating surfaces. A hybrid electrolyte containing SSE coupled with a small amount of ionic liquid, was essential to improve the interface contact of the SSE with the electrodes. Coating-based cathodes were successfully fabricated using water-based carboxymethyl cellulose (CMC) solution and Styrene butadiene rubber (SBR) as the binder with low sulfur loading (0.70 mgcm-2) as well as high sulfur loading (4.0 mgcm-2). Solid-state composite powder-based cathodes pressed onto SSE (loading 4.0 mgcm-2) with enhanced electronic and ionic conductivity were fabricated with Super P: Sulfur (SP:S) and SSE. Ionic Liquids (IL) prepared using Lithium bis(trifluoromethyl sulfonyl)imide (LiTFSI) as salt, with premixed pyrrolidinium bis(trifluoromethyl sulfonyl)imide (PYR) as solvent and 1,3-dioxolane (DOL) as diluent were used to wet both SSE-electrode interfaces. The effect of IL dilution, co-solvent amount, LiTFSI concentration, C rate at which the batteries are tested and the effect of SSE inside the cathode, were systematically studied and optimized to develop a quasi-solid-state electrolyte Li-S battery (QSSLSB) with higher capacity retention and cyclability. LiTFSI (2M) dissolved in PYR:DOL(1:1) found to be optimum IL combination for low sulfur loading QSSLSBs reaching 500 mAh/g after 100 cycles while LiTFSI (3M) in PYR:DOL(1:3) was the optimum IL concentration for higher loading QSSLSBs reaching 400 mAh/g after 100 cycles. This work reports promising results of QSSLSB based on novel Li6PS5F0.5Cl0.5 Li-argyrodite solid-state electrolyte (SSE) with minute amount of IL, Super P-Sulfur (SP:S) cathode, and Li-anode. It also offers a new insight into the intimate interfacial contacts between the SSE and carbon-sulfur cathodes, which will be critical for improved electrochemical performance of quasi-solid-state lithium-sulfur batteries with high sulfur loading in the future.

25 ENERGY STORAGE↗

Cathodic Protection Modeling for Hanford Underground Double-Shell Tank Farms

Hanford stores millions of gallons of radioactive and chemically hazardous waste from the production of weapon materials in tank farms consisting of underground carbon-steel storage tanks surrounded by reinforced concrete. Six of these Hanford tank farms use double-shell storage tanks (DSTs). The DST farms were constructed from 1968 to 1986 with a planned 40–50 year design life, so some are already operating beyond their initial life expectancy. Ultrasonic testing (UT) has indicated significant thinning on the bottom of the secondary (outer) liner of these tanks, believed to arise from groundwater intrusion driving concrete side corrosion. There is no direct access to the steel/concrete interface between the tank and the concrete pad, making it difficult to apply a chemical-based mitigation strategy or to conduct repairs, but cathodic protection (CP) is a possible method to inhibit further concrete-side corrosion. Hanford already uses CP to protect below grade steel piping within the tank farms and connected to the tanks, but this system was not designed to protect the tank bottoms. CP design must account for the structures surrounding the DSTs, including the steel reinforcing bars (rebar) within the concrete pad and vault, various process lines, and the existing CP system. In this study, finite element analysis (FEA) modeling was carried out to simulate CP protection of 1) a single tank and CP anode to develop options for modeling the rebar and to compare to a simpler circuit model and 2) the entire Hanford AN tank farm as a representative example consisting of seven tanks, associated piping, and both existing and new CP anodes. Both circuit and FEA models predict that significant protective current could be delivered to the bottoms of the tanks with the addition of tank-protection anodes below the depth of the tanks. Simulations with only the existing pipe-protection anodes active confirmed that only a very small current to the tank bottoms is predicted under present conditions. Multiple simplified representations of the dome and wall rebar were tested to reduce the computational complexity of the tank-farm simulations, resulting in modeling the rebar as edge elements with a prescribed effective circumference that matches the real rebar surface area. The geometry of the rebar is also simplified into horizontal hoops around the tank walls and radial rebar over the dome with increased effective circumference to retain the target surface area. This simplification was found to greatly reduce the complexity and solution time of the models without large changes in current distributions, especially to the tank bottom. A range of values were tested for model parameters such as soil and concrete resistivities and polarization resistance to investigate their impact on the current and electric potential distributions. Depending on the parameters used, FEA simulations predict some risk of overprotection, particularly on the piping system; since overprotection can also lead to surface damage associated with hydrogen gas generation at the interface (e.g. hydrogen embrittlement or damage to coatings), this needs to be considered when refining the design of the new CP system. Comparison between the FEA models and the circuit model representation demonstrated that the circuit model could not match the predicted FEA current distribution, even when using the exact same surface areas. This discrepancy appeared to be at least partly attributable to the impact of the relative positions of the tank components and anodes to each other and to the ground surface. The FEA model accounts for the relative positions since it solves the governing equations in three dimensions, but the circuit model cannot account for the positioning. In particular, the circuit model underpredicts the current to the tank bottom and overpredicts the current to the dome compared to FEA for the baseline geometry. The FEA models omitted the electrically isolated rebar in the bottom concrete slab. However, a circuit based stray current model estimated that only 2.1% of the total current through the slab would stray into the rebar, corresponding to ~0.21 A for a target current density of 2 mA/ft2 to the tank bottom. The estimated corrosion driven by this amount of stray current is predicted to yield a lifetime of >400 years for the minimum rebar diameter, assuming an acceptable cross-section area loss of 10%.

d'Entremont, Anna [Savannah River National Laborat↗