Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ansys”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

PRD3000: A novel Personnel Radiation Detector with Radiation Exposure Monitoring

PRD3000{sup TM} is a novel Personal Radiation Detector (PRD) with personnel radiation dose exposure monitoring. It is intended for First Responders, Law Enforcement, Customs Inspectors protecting critical infrastructures for detecting unexpected radioactive sources, who also need real time Hp(10) dose equivalent information. Traditional PRD devices use scintillator materials instrumented through either a photomultiplier tube or a photodiode photodetector. While the former is bulky and sensitive to magnetic fields, the latter has to compromise radiation sensitivity and energy threshold given its current noise per unit of photo-detection surface. Recently, solid state photodetectors (SiPM), based on arrays of Geiger operated diodes, have emerged as a scalable digital photodetector for photon counting. Their strong breakdown voltage temperature dependence (on the order of tens of milli-volts per K) has however limited their use for portable instruments where strong temperature gradients can be experienced, and limited power is available to temperature stabilize. The PRD3000 is based on the industry standard DMC3000 active dosimeter that complies with IEC 61526 Ed. 3 and ANSI 42.20 for direct reading personal dose equivalent meters and active personnel radiation monitors. An extension module is based on a CsI(Tl) scintillator readout by a temperature compensated SiPM. Preliminary nuclear tests combined with a measured continuous operation in excess of 240 hours from a single AAA battery cell indicate that the PRD3000 complies with the IEC 62401 Ed.2 and ANSI 42.32 without sacrificing battery life time. We present a summary of the device test results, starting with performance stability over a temperature range of - 20 deg. C to 50 deg. C, false alarm rates and dynamic response time. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3-60B Type-B shipping cask enhanced operational features to facilitate leakage rate testing - 15585

EnergySolutions is fabricating a new 3-60B Type B Shipping Cask that will be ready for use in spring 2015, designed for shipping Type B quantities of activated and/or non-fuel-bearing reactor or accelerator components. EnergySolutions, in consult with Leak Testing Specialists, Inc., has implemented an improved design of the 3-60B cask closures to better facilitate periodic and maintenance leakage rate testing and to allow end users to more easily perform pre-shipment leakage rate testing to confirm proper assembly of the cask closures. A typical Type B cask closure lid design incorporates a double O-ring configuration, where the inner O-ring provides containment and the outer O-ring is used for leakage rate testing of the containment O-ring seal. Leakage rate testing of a double O-ring configuration is typically accomplished by filling the cask cavity with helium, pulling a vacuum on the annular space between the two O-rings and monitoring for helium leakage through the containment O-ring. One issue is the potential for helium saturation of the O-ring elastomeric material, which can result in leakage rate test failures. The cask cavity volume is typically large, and takes a significant amount of time to fill with helium. As a result, the saturation time for certain elastomeric compounds may be exceeded, leading to potential false-negative leakage rate testing results. To avoid this, that the cask cavity typically is loaded with sealed container(s) to reduce the free volume and the fill time. The improved 3-60B cask closure lid incorporates a triple O-ring seal configuration that facilitates maintenance leak rate testing of the closure lid containment O-ring seal and eliminates the issues discussed above. The triple O-ring configuration uses the middle O-ring as the containment seal, with the inner and outer test O-rings creating relatively small annular volumes for testing purposes. These small annular volumes are quick to fill, minimizing the issue of Helium saturation of the O-ring material. This seal configuration also makes it possible to detect and replace a damaged O-ring seal during loading operations, or dress a damaged sealing surface, and perform the required maintenance leakage rate testing of the replacement O-ring at the plant site without the need to unload the cask and send it to a maintenance facility. Also, a second test port has been added to each O-ring annulus to allow leakage rate testing to be accomplished using a formal system calibration that complies with the requirements and recommendations of ASME Section V, Article 10 [4], ANSI N14.5-97 [2], and ANSI N14.5-2014 [3]. This provides a simple, reliable, and accurate means to perform leakage rate testing with a test confidence level that cannot be achieved without the second test port. The improved closure and test port design simplifies and shortens the time required to perform leakage testing, resulting in reduced operating costs, greater schedule security, and dose savings for the cask users. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Time Scale Effects on the Temperature Coefficient of Reactivity

For a nuclear reactor, the temperature coefficient of reactivity (TCR) is of significance for both power control and safety analysis, but it is not always a constant. For example, the TCR may be dependent upon temperature due to Doppler broadening, and may be also dependent upon time scale due to heat transfer and thermal expansion. A fast burst reactor is a favorable nuclear facility to simulate the time scale effects on the TCR. Fast burst reactors are generally unmoderated research reactors of enriched uranium metal or uranium alloys. The neutrons are fast and the Doppler broadening effects can be neglected, and the TCR is mainly contributed by fuel thermal expansion. Fast burst reactors can operate on both steady state power mode and burst power mode. In steady state power mode, the systems are assumed to be in thermal equilibrium. In burst mode, the full width at half maximum (FWHM) of the power is from tens of microseconds to a few milliseconds, and the heat transfer is generally neglected. If FWHM is short enough, thermal expansion will have a time delay due to inertial effect. This paper is aimed to study the exact time scale effects on the TCR due to thermal expansion. The TCR contributed by the Doppler broadening effects was neglected, because it is relatively small (The k{sub eff} as a function of temperature was also calculated using the Monte Carlo particle transport code JMCT by our group, and no definite difference due to the temperature change was obtained near room temperature), and there is no method to evaluate the time scale dependence of the Doppler broadening effects yet. In the time scale from 1 x 10{sup -6} s to 1 x 10{sup 5} s, the TCR of a Godiva-like spherical fast burst reactor was calculated with perturbation theory. A Godiva-like spherical fast burst reactor was studied, the calculation of the time scale effects on TCR involved thermal conduction, thermoelasticity and reactivity variation analysis. Both the thermal and the thermoelastic problems were solved using ANSYS software. ANSYS is software implementation of finite element simulations, which is widely used in engineering field. The reactivity variation due to thermal expansion was calculated with perturbation theory.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improving and Automating Building Model Data Exchange

There are many instances throughout a project’s lifecycle where there arises a need for quick and accurate risk assessment of building designs. For example, an unexpected design change during construction may necessitate structural engineers to perform a seismic risk assessment on analytical models of the updated building design using high fidelity structural analysis software, such as ANSYS or Abaqus. However, the efficiency of such workflows often depends upon the interoperability of architectural design software and structural analysis software. When the quality of this interoperability is lacking or even non-existent, the efficiency of virtual engineering workflows is hampered, which increases project costs. A McGraw Hill industry survey of professional users of Building Information Modeling (BIM) technologies found that there is high demand for BIM interoperability for structural analysis, but that the value/difficulty ratio is currently too low for practical use. There have been efforts by the academic community to facilitate model data exchange between the architectural design and structural analysis domains, but such solutions have not been widely adopted by industry, face technical challenges, and oftentimes are limited in applicability for users of various BIM software. Therefore, INL is developing capabilities to improve, automate, and generalize model data exchange between architectural BIM software (e.g., Revit) and structural analysis software (e.g., SAP2000, ANSYS). The goal is to help expedite and automate as much of the pre-processing step for creating analytical models in finite element analysis software as reasonably as possible. Such a "BIM-to-FEA" conversion tool should provide direct benefit to end-users through accuracy, automation, quick turn-around, and wide applicability. To generalize the application of this BIM-to-FEA conversion tool and increase its useability among the many different commercial BIM software currently used by industry, the program is being developed with the concept of openBIM. OpenBIM is the application of non-proprietary, open data standards that allow for BIM model data exchange in a format that is accessible, retainable, and useable for all users. The most widely used open, non-proprietary data exchange format for BIM is the Industry Foundation Classes (IFC) schema. IFC is developed by buildingSMART international and is ISO certified (ISO 16739-1:2018). The BIM-to-FEA conversion tool is being developed for compatibility with typical commercial building designs of steel framed structures. The tool is currently capable of importing architectural BIM data of framed building structures, recognizing and extracting the aspects of the model that are required for structural analysis, adjusting the connectivity of frame members, and finally exporting to an analytical model stored in the IFC format. The exported IFC analytical model can then be imported into various openBIM compliant software, such as SAP2000. Such capabilities have already been tested on commercial software, as shown above, and continue to be improved. Work is underway to test the conversion on various commercial BIM software, develop a user-friendly interface, incorporate the program into the broader DeepLynx data warehouse project being developed by INL, and to eventually open-source the tool for the benefit of the community. Future development of the tool envisions the ability for efficient iterative risk assessment of generative building designs, all within a workflow utilizing open-source tools. One such open-source tool will be MOOSE, an advanced finite element analysis tool developed at INL. The conversion tool will also branch out from typical commercial building designs and will aim to incorporate nuclear construction. The aim will be to convert both structural and non-structural components of nuclear facilities, such as curved concrete containment structures and piping systems, respectively.

97 MATHEMATICS AND COMPUTING↗

PERFORMANCE TESTING OF SPRING ENERGIZED C-RINGS FOR USE IN RADIOACTIVE MATERIAL PACKAGINGS CONTAINING TRITIUM

This paper describes the sealing performance testing and results of silver-plated inconel Spring Energized C-Rings used for tritium containment in radioactive shipping packagings. The test methodology used follows requirements of the American Society of Mechanical Engineers (ASME) summarized in ASME Pressure Vessel Code (B&PVC), Section V, Article 10, Appendix IX (Helium Mass Spectrometer Test - Hood Technique) and recommendations by the American National Standards Institute (ANSI) described in ANSI N14.5-1997. The tests parameters bound the predicted structural and thermal responses from conditions defined in the Code of Federal Regulations 10 CFR 71. The testing includes an evaluation of the effects of pressure, temperature, flange deflection, surface roughness, permeation, closure torque, torque sequencing and re-use on performance of metal C-Ring seals.

42 ENGINEERING↗

Engineered and Administrative Safety Systems for the Control of Prompt Radiation Hazards at Accelerator Facilities

The ANSI N43.1 Standard, currently in revision (ANSI 2007), sets forth the requirements for accelerator facilities to provide adequate protection for the workers, the public and the environment from the hazards of ionizing radiation produced during and from accelerator operations. The Standard also recommends good practices that, when followed, provide a level of radiation protection consistent with those established for the accelerator communities. The N43.1 Standard is suitable for all accelerator facilities (using electron, positron, proton, or ion particle beams) capable of producing radiation, subject to federal or state regulations. The requirements (see word 'shall') and recommended practices (see word 'should') are prescribed in a graded approach that are commensurate with the complexity and hazard levels of the accelerator facility. Chapters 4, 5 and 6 of the N43.1 Standard address specially the Radiation Safety System (RSS), both engineered and administrative systems, to mitigate and control the prompt radiation hazards from accelerator operations. The RSS includes the Access Control System (ACS) and Radiation Control System (RCS). The main requirements and recommendations of the N43.1 Standard regarding the management, technical and operational aspects of the RSS are described and condensed in this report. Clearly some aspects of the RSS policies and practices at different facilities may differ in order to meet the practical needs for field implementation. A previous report (Liu et al. 2001a), which reviews and summarizes the RSS at five North American high-energy accelerator facilities, as well as the RSS references for the 5 labs (Drozdoff 2001; Gallegos 1996; Ipe and Liu 1992; Liu 1999; Liu 2001b; Rokni 1996; TJNAF 1994; Yotam et al. 1991), can be consulted for the actual RSS implementation at various laboratories. A comprehensive report describing the RSS at the Stanford Linear Accelerator Center (SLAC 2006) can also serve as a reference.

43 PARTICLE ACCELERATORS↗

Toroidal magnetic field ripple in the presence of misaligned toroidal field coils on the COMPASS-U tokamak

Homogeneity of the toroidal magnetic field is a critical aspect of the tokamak fusion device. It is affected by the design of toroidal magnetic field coils and their manufacturing and assembly misalignments. The magnetic field of the COMPASS-U project is analysed using toroidal field ripple quantity. Here ANSYS modelling of bitter-plate-designed toroidal field coils is performed to prepare an accurate simplistic representation of the coils using a virtual current line. Toroidal field ripple is analysed using a Gaussian distribution of possible misalignments. The worst-case toroidal field ripple corresponding to the technical drawings only slightly exceeds the chosen limit of 0.5%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A review of computational methods for studying oscillating water columns – the Navier-Stokes based equation approach

This review evaluates the state-of-the-practice numerical tools used to predict the performance of Oscillating Water Column (OWC). The OWC is a widely studied Wave Energy Converter that provides a reliable form of renewable form of electricity that can potentially meet global energy needs. However, the fluid-flow phenomena affecting its hydrodynamic performance are not fully understood. While there has been the successful full-scale deployment of OWCs, various computational methods are being explored to optimize this technology. Potential flow theory is commonly used to evaluate the efficiency of OWCs; however, this assumption tends to over-predict the hydrodynamic performance. Recently, numerical studies using a diverse set of commercial, open-source, or in-house Computational Fluid Dynamics (CFD) using Reynolds Averaged Navier Stokes (RANS) and Large-Eddy Simulation codes show a better comparison to available experimental results but are computationally expensive. ANSYS Fluent was found to be the most widely used CFD code applied to the study of the OWCs, with a high degree of accuracy in terms of experimental validation of numerical results.

16 TIDAL AND WAVE POWER↗

High-Fidelity CFD Modeling of Cryogenic Hydrogen Isotope Extrusion for Fusion Reactor Pellet Fueling

This study investigates the extrusion processes of deuterium and protium using ANSYS-Polyflow. The geometries and computational fluid dynamics (CFD) settings closely replicate the experimental setups and data acquired from the extruder experiments at Oak Ridge National Laboratory (ORNL) for validation purposes. We explore the impacts of (1) slip versus non-slip boundary conditions and (2) the use of constant, temperature-, and shear rate–dependent viscosities, concluding that the implementation of non-slip wall boundary conditions combined with shear rate–dependent viscosity produced more accurate predictions. The simulations achieved excellent agreement with the experimental data, with relative differences of only 5% for deuterium, and 3% to 6% for protium. This is the first time that experimental extrusion data at ORNL have been accurately predicted through high-fidelity CFD modeling. In conclusion, the advancements offer valuable insights and a foundational modeling tool for optimizing pellet injectors for ITER and other future reactor-scale devices.

ANSYS-Polyflow↗

Technical Assessment of Internal Surface Smoothness and Particle Transmission to the American National Standard ANSI/HPS N13.1-2011

Clause 6.4.4 in the American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1 standard, Sampling and Monitoring Releases of Airborne Radioactive Substances From the Stacks and Ducts of Nuclear Facilities, addresses the internal smoothness of sample transport lines present between the nozzle and the analyzer (or collector). This paper evaluates the appropriateness of this clause by comparing roughness length of various materials against the required relative roughness, and by conducting computational fluid dynamic modeling. The results indicate that the inclusion of numerical criteria for the relative roughness of pipe by the ANSI Standard N13.1 (Section 6.4.4) is not appropriate. Recommended alternatives would be elimination of the numerical criteria, or modification of the standard to include a variable criteria for relative roughness.

operational topics, aerosols, air sampling, atmosp↗

Full-Wave and Circuit-Based Simulations of Cable Insulation Aging/Damage Using Time-Frequency Domain Reflectometry

This paper presents a combined full-wave and circuit-based simulation study to investigate the important topic of cable insulation aging and physical damage. The analysis employs the time-frequency domain reflectometry (TFDR) technique that combines the advantages of both time domain reflectometry (TDR) and frequency domain reflectometry (FDR) for improved location identification and feature resolution. Coaxial cable sections with a location containing insulation aging or physical damage are simulated using Ansys High Frequency Structure Simulator (HFSS). Simulated scattering (S) parameters are then imported into the Advanced Design System (ADS) solver for time domain simulation where a Gaussian windowed chirp signal or ‘chirplet’ is launched. Finally, continuous wavelet transform (CWT) is applied in MATLAB to perform time-frequency analysis of the reflected waveforms. The results reveal that a small change in the relative permittivity of the insulation or the presence of a small point of physical damage on the insulation is reflected as a considerable change in the CWT magnitude demonstrating the efficacy of the method.

cable aging, Non Destructive Examination, time-fre↗

Comparison of ISO and ANSI/ANS Nuclear Criticality Safety Standards

This paper provides a high-level comparison between the international and domestic Nuclear Criticality Safety (NCS) standards, as requested by members of the Nuclear Criticality Safety Division. Currently, there are 18 enacted American National Standards Institute (ANSI)/American National Standards (ANS) and 1 ANSI/ANS standard in progress. There are 11 NCS standards from the International Organization for Standardization (ISO), Technical Committee 85 (TC85) on Nuclear Energy, Subcommittee 5 (SC5) on Nuclear Fuel Cycle, Working Group 8 (WG8). There are NCS standard revisions in progress for both standards organizations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ANSI/ASHRAE/IESNA Standard 90.1-2007 Final Determination Quantitative Analysis

The United States (U.S.) Department of Energy (DOE) conducted a final quantitative analysis to assess whether buildings constructed according to the requirements of the American National Standards Institute (ANSI)/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)/Illuminating Engineering Society of North America (IESNA) Standard 90.1-2007 would result in energy savings compared with buildings constructed to ANSI/ASHRAE/IESNA Standard 90.1-2004. The final analysis considered each of the 44 addenda to ANSI/ASHRAE/IESNA Standard 90.1-2004 that were included in ANSI/ASHRAE/IESNA Standard 90.1-2007. All 44 addenda processed by ASHRAE in the creation of Standard 90.1-2007 from Standard 90.1-2004 were reviewed by DOE, and their combined impact on a suite of 15 building prototype models in 15 ASHRAE climate zones was considered. Most addenda were deemed to have little quantifiable impact on building efficiency for the purpose of DOE’s final determination. However, out of the 44 addenda, 9 were preliminarily determined to have measureable and quantifiable impact.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ANSI/ASHRAE/IESNA Standard 90.1-2007 Final Qualitative Determination

A final qualitative analysis of all addenda to American National Standards Institute (ANSI)/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)/Illuminating Engineering Society of North America (IESNA) Standard 90.1-2004 that were included in ANSI/ASHRAE/IESNA Standard 90.1-2007 was conducted. All 44 addenda processed by ASHRAE in the creation of Standard 90.1-2007 from Standard 90.1-2004 were evaluated by the U.S. Department of Energy (DOE) for their impact on energy efficiency. DOE preliminarily determined whether that addenda would have a positive, neutral, or negative impact on overall building efficiency. Table S.1 shows the number of positive and negative changes for each section of Standard 90.1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ANSI/ASHRAE/IESNA Standard 90.1-2010 Preliminary Determination Quantitative Analysis

The United States (U.S.) Department of Energy (DOE) conducted a preliminary quantitative analysis to assess whether buildings constructed according to the requirements of the American National Standards Institute (ANSI)/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)/Illuminating Engineering Society of North America (IESNA) Standard 90.1-2010 (ASHRAE Standard 90.1-2010, Standard 90.1-2010, or 2010 edition) would result in energy savings compared with buildings constructed to ANSI/ASHRAE/IESNA Standard 90.1-2007(ASHRAE Standard 90.1-2007, Standard 90.1-2007, or 2007 edition). The preliminary analysis considered each of the 109 addenda to ASHRAE Standard 90.1-2007 that were included in ASHRAE Standard 90.1-2010. All 109 addenda processed by ASHRAE in the creation of Standard 90.1-2010 from Standard 90.1-2007 were reviewed by DOE, and their combined impact on a suite of 16 building prototype models in 15 ASHRAE climate zones was considered. Most addenda were deemed to have little quantifiable impact on building efficiency for the purpose of DOE’s preliminary determination. However, out of the 109 addenda, 34 were preliminarily determined to have measureable and quantifiable impact.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ANSI/ASHRAE/IESNA Standard 90.1-2010 Preliminary Qualitative Determination

A preliminary qualitative analysis of all addenda to American National Standards Institute (ANSI)/American Society of Heating, Refrigerating, and Air Conditioning Engineers (ASHRAE)/Illuminating Engineering Society of North America (IESNA) Standard 90.1-2007 (Standard 90.1-2007 or 2007 edition) that were included in ANSI/ASHRAE/IESNA Standard 90.1-2010 (Standard 90.1-2010 or 2010 edition) was conducted. All 109 addenda processed by ASHRAE in the creation of Standard 90.1-2010 from Standard 90.1-2007 were evaluated by DOE for their impact on energy efficiency. DOE preliminarily determined whether that addenda would have a positive, neutral, or negative impact on overall building efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hysteresis and degaussing of H1 dipole magnets

Hysteresis was observed in the H1 dipole magnets in CBETA SX line. This study is the first step in order to understand and mitigate the effects this has on field reproducibility. Ansys Maxwell 19.2 was used to model the MS1DIP05 magnet with a hysteretic core. The parameter space for a degaussing procedure using the trim coils was explored. It was found that significant degaussing can be obtained with a decaying ringing waveform of magnitudes above 10 A, so long as the frequency ƒ and decay constant w were chosen such that ƒ >> w. The circuit properties of the magnet were simulated and explored using a sinusoidal voltage input. It was found that for low frequencies ƒ << 1 Hz, the magnet behaves as a series LR circuit with R = (28.3 ± 0.5) mΩ and L = (5.7 ± 0.1) mH. At higher frequencies, hysteretic effects become significant, and resistance becomes proportional to the frequency due to hysteretic losses. A drop and saturation in inductance for higher frequencies was observed in the simulation data. Numerical instabilities were found for excitations below small voltages V < 50 mV. Experimental results on degaussing and current corrections were collected with Hall probe measurements. Good qualitative agreement with simulation results was found, but due to B-H curve details quantitative comparisons were inaccurate. Two procedures, MaxOp and MaxNull, were designed to produce repeatable operating field values to within 0.1 G.

43 PARTICLE ACCELERATORS↗

Comparison of ISO and ANSI/ANS Nuclear Criticality Safety Standards [Slides]

This paper provides a high-level comparison between the international and domestic nuclear criticality safety (NCS) standards, as requested by members of the Nuclear Criticality Safety Division. Currently, there are 18 enacted American National Standards Institute (ANSI)/American National Standards (ANS) standards, and 1 ANSI/ANS standard, in progress. There are 11 NCS standards from the International Organization for Standardization (ISO), Technical Committee 85 (TC85) on Nuclear Energy, Subcommittee 5 (SC5) on Nuclear Fuel Cycle, Working Group 8 (WG8). NCS standard revisions are in progress for both standards organizations. The key differences between the ISO TC85/SC5/WG8 and ANSI/ANS-8 consensus NCS standards are summarized. The hard work done by the ANS-8 and WG8 volunteers allows for applicable, high-quality consensus standards for use by the NCS community. This paper defines the current status of each ANSI/ANS and ISO standard, the work in in progress, the revisions/amendments in progress, and WG8/ANS-8 non-standard business in progress. A forthcoming paper will compare the development process for ISO and ANSI/ANS standards.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗