Electrochemical Measurement of Atmospheric Corrosion

Corrosion of Shuttle thruster components in atmospheres containing high concentrations of nitrogen tetroxide (NTO) and water is an important issue in ground operations of bipropellant systems in humid locations. Measurements of the corrosivities of NTO-containing atmospheres and the responses of different materials to these atmospheres have been accomplished using an electrochemical sensor. The sensor is composed of alternating aluminum/titanium strips separated by thin insulating layers. Under high humidity conditions a thin film of water covers the surface of the sensor. Added NTO vapor reacts with the water film to form a conductive medium and establishes a galvanic cell. The current from this cell can be integrated with respect to time and related to the corrosion activity. The surface layer formed from humid air/NTO reacts in the same way as an aqueous solution of nitric acid. Nitric acid is generally considered an important agent in NTO corrosion situations. The aluminum/titanium sensor is unresponsive to dry air, responds slightly to humid air (> 75% RH), and responds strongly to the combination of humid air and NTO. The sensor response is a power function (n = 2) of the NTO concentration. The sensor does not respond to NTO in dry air. The response of other materials in this type of sensor is related to position of the material in a galvanic series in aqueous nitric acid. The concept and operation of this electrochemical corrosion measurement is being applied to other corrosive atmospheric contaminants such as hydrogen chloride, hydrogen fluoride, sulfur dioxide, and acidic aerosols.

DeArmond, Anna H.↗

Electrochemical Corrosion of SIMFUEL: Effects of dissolved H2 and noble metal particles

This report describes the results from electrochemical corrosion tests that were conducted using simulated spent fuel (SIMFUEL) materials comprised of UO2 and surrogate fission products. Two SIMFUEL compositions were tested to quantify the effect of noble metal inclusions and dissolved H2 on the UO2 dissolution rate. One material consisted of UO2 with added lanthanide oxides (UO2 N) and the other consisted of UO2 with added lanthanide oxides and noble metals (UO2-H) at concentrations to simulate high burnup fuel. The electrochemical corrosion tests on the SIMFUEL materials were conducted in aqueous electrolyte solutions (pH 10) that were either saturated with air or purged with a H2/Ar gas mixture to maintain a constant dissolved H2 concentration. The results from electrochemical corrosion tests on SIMFUEL can be applied to qualitatively understand and also quantify the separate effects of water chemistry and fuel composition on the degradation behavior of the UO2 matrix. Open circuit potential (OCP) measurements on a SIMFUEL material of known composition (i.e., known fraction of NMPs at the fuel surface) immersed in a known solution chemistry (i.e., pH, Eh, [O2], [H2]) at known temperature provide qualitative insight into the degradation behavior of the UO2 matrix. If the OCP is above the threshold potential at which the oxidative dissolution of U(IV) to U(VI) occurs, the SNF is expected to degrade by oxidative processes under the experimental conditions. The net currents that are measured during potentiostatic tests, during which the surface potential of the SIMFUEL material is fixed by a potentiostat, can be used to quantify the UO2 degradation rate and optimize the rate constant values used in the Fuel Matrix Degradation Model (FMDM) for half reactions that occur on the SNF surface. Specifically, electrochemical measurements enable the estimation of the total anodic current at ECORR–which is the surface potential at which the total anodic and total cathodic currents are equal–so that the rate constant values for key reactions can be calculated. The open circuit potential measurements, potentiostatic tests, surface property measurements (scanning electron microscopy images and electrochemical impedence spectroscopy plots), and solution elemental composition analyses are being performed to update and optimize the FMDM. A case study is presented herein to show how electrochemical corrosion test results and accompanying characterization results for the UO2 N material in air-saturated solution can be used to validate the SNF surface reaction module of the FMDM. Future electrochemical tests will be conducted to provide quantitative information on the effects of NM content (burnup), H2 concentration, water chemistry, temperature, and galvanic couples with cladding and EBS alloys on UO2 degradation that can be used to improve the accuracy and functionality of the FMDM.

Thomas, Sara↗

A Direct Ammonia Fuel Cell with a KOH-Free Anode Feed Generating 180 mW cm −2 at 120 °C

The motivations to operate the direct ammonia fuel cell (DAFC) with no addition of aqueous base, include facilitated fuel management and prevention of corrosion and shunt currents in the DAFC stack. We describe here a polymer electrolyte DAFC, operating at a cell temperature (T cell ) of 120 °C on ammonia and water alone as anode feed, that demonstrated peak power of 180 mW cm −2 —a record for this type of fuel cell. We offer a detailed analysis of polarization curves recorded for PE-DAFCs in the T cell range of 60 °C–120 °C, allowing to estimate the effects of KOH-free operation on the ionic and faradaic resistances, R i and R F , that determine together the value of R app , CL – an , the apparent resistance of the anode catalyst layer. The latter resistance drops ten times between 60 °C and 120 °C as result mainly of the drop in R F . Consequently, DAFC performance at T cell > 100 °C improves substantially, including the cell performance on a KOH-free anode feed. The demsontrated performance levels reported here for KOH-free DAFCs support further development of this type of ammonia/air fuel cells.

Achrai, Ben↗

An effective air–liquid contactor for CO 2 direct air capture using aqueous solvents

Here, the development of a cost-effective, corrosion resistant, high-flux direct air capture (HiDAC) contactor for a solvent-based direct air capture (DAC) process is reported. Literature technoeconomic analyses suggest that the air–liquid contactor can cost over 20 % of the overall DAC plant’s annualized capital costs. To bring down the overall cost of DAC, it is imperative that an effective contactor is developed. A hybrid contactor consisting of a commercial polyvinylchloride structured packing enhanced with stainless-steel 410 random packing has been developed to provide a high surface area for air–liquid contact. The contactor geometry, wettability, corrosion resistance, pressure drop, along with its CO 2 uptake efficiency, CO 2 uptake rates, and extended loading potential using potassium sarcosinate solutions are investigated. Results show that the HiDAC contactor has a relatively high specific surface area (885 m 2 /m 3 ), which allows for CO 2 uptake efficiencies of up to 75 % and capture rates of up to 550 g of CO 2 per day for a 0.3 × 0.25 × 0.3 m contactor. The contactor also exhibits high levels of wettability and corrosion resistance with amino acid-based DAC solvents. A CO 2 uptake model was developed, and modeling results are compared to experimental data to simulate and predict the performance of the contactor in a DAC process using potassium sarcosinate solvent. The system’s overall mass transfer coefficient and theoretical pressure drop were also calculated, and these results were compared to DAC data found in literature. The results presented indicate that the HiDAC contactor is well suited for DAC due to its high specific surface area, resistance to corrosion, and high degree of wettability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CO 2 Capture with Capsules of Ionic Liquid/Amines

Carbon capture remains an urgent issue that has gained a great deal of attention over the past few decades. Aqueous amines have excellent selectivity, but present corrosion and volatility issues, whereas ionic liquids (ILs) have negligible volatility and tunable physical properties, but high viscosities. One approach to improve the practical performance of these liquids is encapsulating them in a CO 2 permeable polymer shell to enhance the accessibility of the liquid and the CO 2 absorption rate. In this work, we report the encapsulation of a mixture of amine and IL (i.e., monoethanolamine (MEA) and 1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM][BF 4 ])) and demonstrate enhanced carbon capture performance. A soft-template approach and interfacial polymerization are used to give capsules with liquid core (64 wt %) and polyurea shell. Compared to the bulk liquid, the encapsulated liquid shows improved thermal stability over cycles of absorption at 25 °C, and desorption at 75 °C. The capsules with core of [BMIM][BF 4 ]-MEA show 0.2 mol CO 2 /kg of capsules at 1 bar CO 2 , compared to the bulk liquid, which has 0.05 mol CO 2 /kg of sorbent. This is attributed to the limited evaporation of the amines. Alternatively, the same capsules but with 5 wt % of piperazine (Pz) in the core have doubled gravimetric CO 2 capacity of the capsules (0.4 mol CO 2 /kg of capsules); performance is evaluated over 10 capture–release cycles showing minimal mass loss. Characterization of the CO 2 uptake of the polymer shell itself reveals that the shell contributes only ~10% of the observed capacity, likely attributed to amine functionalities of the polymer. Here, this facile approach to encapsulating such “active” liquids can be applied to other CO 2 selective solvents that are volatile, viscous, and corrosive.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Specific-ion electrodes for measuring Ag ions

Migration of aqueous solutions through electrode pellet, and thus corrosion of soldered connection, is prevented by coating pellet and silver wire attachment with silver-conductive epoxy.

Day, J. L.↗

Deep Learning Potential For Investigation of Chemical Conversion of CO2 at Air-Reactive Deep Eutectic Solvent Interface

Capturing CO2 from air is urgent to battle against the climate change. Traditional CO2 capture by alkaline solution or aqueous amine has high regeneration cost, equipment corrosion, and amine leakage. Deep eutectic solvents (DESs) are promising alternatives with low corrosion, non-toxicity, and biodegradable nature. Functionalized DESs can capture and convert CO2 at low partial pressures. Developing reactive DESs for efficient CO2 capture needs a foundational understanding of the reaction-transport coupling of CO2 at the air-DES interface. In this study, we develop a deep learning potential (DLP) to investigate the absorption and reaction of CO2 at the air-DES interface (DES: 1-ethyl-3-methylimidazolium 2-cyanopyrrolide ([Emim][2-CNpyr]) and ethylene glycol (EG)). The DLP model allows us to simulate chemical reactions at a lower computational cost with ab initio accuracy. By analyzing reaction free energy surfaces, molecular interactions among CO2, DES components and reaction products, and transport of CO2 through the interface, we identify three main reaction pathways of CO2 at the interface: forming carboxylate with [Emim], carbamate with [2-CNpyr], and carbonate with EG. The mechanistic understanding of CO2 chemisorption at the interface will facilitate the development of novel direct air capture technology using DESs.

Nguyen, Manh Tien↗

The effects of pitting on fatigue crack nucleation in 7075-T6 aluminum alloy

A high-strength aluminum alloy, 7075-T6, was studied to quantitatively evaluate chemical pitting effects of its corrosion fatigue life. The study focused on pit nucleation, pit growth, and fatigue crack nucleation. Pitting corrosion fatigue experiments were conducted in 3.5 percent NaCl aqueous solution under constant amplitude sinusoidal loading at two frequencies, 5 and 20 Hz. Smooth and unnotched specimens were used in this investigation. A video recording system was developed to allow in situ observation of the surface changes of the specimens during testing. The results indicated that pitting corrosion considerably reduces the fatigue strength by accelerating fatigue crack nucleation. A metallographic examination was conducted on the specimens to evaluate the nature of corrosion pits. First, the actual shapes of the corrosion pits were evaluated by cross-sectioning the pits. Secondly, the relation between corrosion pits and microstructure was also investigated. Finally, the possibility of another corrosion mechanism that might be involved in pitting was explored in this investigation. The fractography of the tested specimens showed that corner corrosion pits were responsible for fatigue crack nucleation in the material due to the associated stress concentration. The pits exhibited variance of morphology. Fatigue life for the experimental conditions appeared to be strongly dependent on pitting kinetics and the crack nucleation stage.

Ma, LI↗

An Impedance-Loaded Surface Acoustic Wave Corrosion Sensor for Infrastructure Monitoring

Passive surface acoustic wave (SAW) devices are attractive candidates for continuous wireless monitoring of corrosion in large infrastructures. However, acoustic loss in the aqueous medium and limited read range usually create challenges in their widespread use for monitoring large systems such as oil and gas (O&G) pipelines, aircraft, and processing plants. This paper presents the investigation of impedance-loaded reflective delay line (IL-RDL) SAW devices for monitoring metal corrosion under O&G pipeline-relevant conditions. Specifically, we studied the effect of change in resistivity of a reflector on the backscattered signal of an RDL and investigated an optimal range through simulation. This was followed by the experimental demonstrations of real-time monitoring of Fe film corrosion in pressurized (550 psi) humid CO 2 conditions. Additionally, remote monitoring of Fe film corrosion in an acidic solution inside a 70 m carbon steel pipe was demonstrated using guided waves. This paper also suggests potential ways to improve the sensing response of IL-RDLs.

47 OTHER INSTRUMENTATION↗

Space Shuttle Upgrades: Long Life Alkaline Fuel Cell

NASA has utilized the alkaline fuel cell technology to provide electrical power for manned launch vehicles such as Gemini, Apollo, and the Space Shuttle. The current Shuttle alkaline fuel cells are procured from UTC Fuel Cells, a United Technologies Company. The alkaline fuel cells are very reliable but the operating life is limited to 2600 hours due to voltage degradation of the individual cells. The main limiting factor in the life of the cells is corrosion of the cell's fiberglass/epoxy frame by the aqueous potassium hydroxide electrolyte. To reduce operating costs, the orbiter program office approved the Long Life Alkaline Fuel Cell (LLAFC) program as a shuttle upgrade in 1999 to increase the operating life of the fuel cell powerplant to 5000 hours. The LLAFC program incorporates improving the cell by extending the length of the corrosion path, which reduces the cell frame corrosion. UTCFC performed analysis to understand the fundamental mechanisms that drive the cell frame corrosion. The analysis indicated that the corrosion path started along the bond line between the cathode and the cell frame. Analysis also showed that the oxygen available at the cathode, the catalyst on the electrode, and the electrode substrate all supported or intensified the corrosion. The new cell design essentially doubled the corrosion path to mitigate the problem. A 10-cell stack was tested for 5000 hours during the development phase of this program to verify improved cell performance. A complete 96-cell stack was then tested for 5000 hours during the full manned-space qualification phase of this program. Additional upgrades to the powerplant under this program are: replacing the aluminum body in the pressure regulator with stainless steel to reduce corrosion, improving stack insulator plate with improved resistance to stress failure and improved temperature capability, and replacing separator plate elastomer seals with a more durable material and improved seal retention.

Kerri McCurdy↗

Galvanic Corrosion of Carbon Steel and Stainless Steel Couples: Effects of γ-Radiation and Solution Environment - 20348

Galvanic corrosion between carbon steel (CS) and stainless steel (SS) in different aqueous environments was investigated using a combination of electrochemical measurements and surface characterizations. In a basic environment (pH 10.6), the galvanic effect is negligible due to the high corrosion resistance of both alloys. In an acidic to near neutral environment (pH 6.0), the galvanic effect is more significant. Coupling to SS, increasing temperature, and irradiation at this pH have a synergistic effect on the corrosion progression of CS, and their effects vary with time. Initially, the oxidation rate of CS increases after galvanic coupling to SS. Increasing temperature or applying γ-radiation accelerates this oxidation process. However, at a longer time when the saturation limits of metal cations are reached, they also lead to the formation and growth of oxides on CS at a much faster rate, resulting in the suppression of the subsequent Fe dissolution. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nanostructured Black Nickel Coating as Replacement for Black Cr(VI) Finish

This work compares different electrodeposition procedures to produce nickel black coatings as greener and less toxic alternatives to Cr(VI)-based coatings used in different applications. Nickel and nickel-plated brass served as substrates in studies with a Hull cell and polarization curves. After a set of comparative experiments, the best electrodeposition procedure was further studied and optimized. Optimal conditions were found with a bath consisting of 75 g/L NiCl2·6H2O + 30 g/L NaCl and a current density of 0.143 A dm−2 applied for 5 min at room temperature. Furthermore, a pre-treatment with 18.5 vol.% of hydrochloric acid in water was found to be necessary to warrant good coating adhesion to the substrate. The black color is attributed to the development of a nanostructured surface that absorbs the incident light. Corrosion testing was performed in 0.5 M NaCl aqueous solution using electrochemical impedance spectroscopy (EIS) and polarization tests.

Mennucci, Marina M. (ORCID:0000000171886804)↗

Hydrothermal corrosion of laser printed SiC fibers under extreme environment

We report SiC/SiC fiber composites are proposed cladding materials to improve the accident tolerance of commercial light water nuclear reactor fuel. To evaluate their viability, understanding the kinetics of corrosion under irradiation and high-temperature, high-pressure aqueous environment is critical. In the present work, the microstructure and mechanical properties of novel SiC fibers manufactured by Laser Chemical Vapor Deposition (LCVD) are introduced. The LCVD technology has control over microstructure and stoichiometry while allowing for high purity manufacturing, all key qualities needed in search of an optimum SiC fiber for nuclear energy applications. The isolated hydrothermal corrosion of commercially available carbon-rich Hi-Nicalon Type-S fibers is compared to the LCVD stoichiometric and LCVD silicon-rich fibers. Autoclave testing was carried out at 310°C and 14 MPa in the absence of irradiation. In a separate study, the effect of gamma irradiation on the fibers in the room-temperature environment was analyzed. It was observed from the experiments that the dissolution of the fibers was highly dependent on the stoichiometric ratio, fiber surface morphology and thermal pre-treatment of fibers. Contrary to previous findings, fiber dissolution was also visible under low-temperature gamma irradiation in aqueous environment with LCVD fibers showing lower dissolution.

36 MATERIALS SCIENCE↗

Aqueous Ni-rich-cathode dispersions processed with phosphoric acid for lithium-ion batteries with ultra-thick electrodes

Lithium-ion battery (LIB) production can benefit both economically and environmentally from aqueous processing. Although these electrodes have the potential to surpass electrodes conventionally processed with N -methyl-2-pyrrolidone (NMP) in terms of performance, significant issues still exist with respect to ultra-thick cathodes ($\gg$4 mAh/cm 2 areal capacities). A major concern for these types of electrodes with high-nickel active material stems from lithium leaching from active material, which drives the pH of the dispersion in excess of 12 and subsequently corrodes the current collector interface. As this corrosion reaction proceeds, hydrogen generation at the interface creates bubbles which cause severe cracking in the dried electrode surface. When areal loadings are increased, this effect becomes more pronounced and is detrimental to both mechanical and electrochemical properties of these electrodes. In this work, a technique for mitigating corrosion at the current collector by adjusting the pH of the dispersion with the addition of phosphoric acid is investigated. Phosphoric acid was added in 0.5 wt% increments between 0.0 and 1.5 wt%, and effects on rheology, adhesion, corrosion, and electrochemical performance were investigated. A technique is reported for producing aqueous processed cathodes with areal loadings of 6–8 mAh/cm 2 with reduced surface cracking and superior high-rate discharge capacity (i.e. high-power performance) for this class of cathode loadings.

25 ENERGY STORAGE↗

Neptunium redox speciation and determination of its total concentration in dissolved fuel simulant solutions by spectrophotometry

Here, two new approaches to measure Np concentration in dissolved used nuclear fuel simulant (aqueous feed for PUREX process) by spectrophotometry are developed. The first approach is based on chemical reduction of Np in the feed to its tetravalent state using ascorbic acid with simultaneous conversion of Pu(IV) to Pu(III). Interfering effects from light absorbing fission and corrosion products are accounted for by measuring optical absorbance spectrum of aqueous raffinate after extraction of U, Np, and Pu by tributyl phosphate in dodecane. The second approach uses no chemical treatment at all and relies on spontaneous valency adjustment of Np to Np(V) by dilution of the feed with water to reduce its acidity to low decimolar range of nitric acid concentration. Results of Np determination in the feed by spectrophotometry are in good agreement with its concentration measured by ICP-MS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗