Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atmospheric Limb”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The Retrieval of Ozone Profiles from Limb Scatter Measurements: Theory

An algorithm is presented for retrieving vertical profiles of O3 concentration using measurements of UV and visible light scattered from the limb of the atmosphere. The UV measurements provide information about the O3 profile in the upper and middle stratosphere, while only visible wavelengths are capable of probing the lower stratospheric O3 profile. Sensitivity to the underlying scene reflectance is greatly reduced by normalizing measurements at a tangent height high in the atmosphere (approximately 55 km), and relating measurements taken at lower altitudes to this normalization point. To decrease the effect of scattering by thin aerosols/clouds that may be present in the field of view, these normalized measurements are then combined by pairing wavelengths with strong and weak O3 absorption. We conclude that limb scatter can be used to measure O3 between 15 km and 50 km with 2-3 km vertical resolution and better than 10% accuracy.

Flittner, D. E.↗

Climate Suite Study for the National Polar-Orbiting Operational Environmental Satellite System Internal Concepts Study: Ozone Sensors - Part A

Our recommendations to NPOESS for the sensors it should adopt to meet threshold requirements for global monitoring of ozone and, to some extent, of aerosols and of atmospheric temperature, pressure, and water vapor content are summarized in this report. The degree to which these sensors fulfill other NPOESS requirements than ozone is also summarized. The number of sensors that should be in the constellation is discussed in terms of desired reliability, continuity of coverage, and the ability to cross-calibrate successive sensors. Our recommendations for specific ozone measurement requirements, IORD item 4.1.6.2.28, are given. We make the case that the monitoring of three minor constituents in the upper atmosphere (N20, ClO or ClONO2, and HNO3) should be added to the list of NPOESS requirements because of their importance to long-term ozone studies and the small additional cost required (ozone sensors are already designed to measure them). Specific measurement requirements, which should be regarded as supplementary to the ozone requirement, are given here. The necessity of using two types of sensors, nadir-viewers and limb-scanners, for atmospheric studies is discussed.

Lucke, R. L.↗

Variability of ozone loss during Arctic winter (1991 to 2000) estimated from UARS Microwave Limb Sounder measurement

A comprehensive analysis of version 5 Upper Atmosphere Research Satellite (UARS) Microwave Limb Sounder (MLS) ozone data using a Lagrangian Transport (LT) model provides estimates of chemical ozone depletion for the 1991-1992 through 1997-1998 Arctic winters. These new estimates give a consistent, three-dimensional picture of ozone loss during seven Arctic winters; previous Arctic ozone loss estimates from MLS were based on various earlier data versions and were done only for late winter and only for a subset of the years observed by MLS. We find large interannual variability in the amount, timing, and patterns of ozone depletion and in the degree to which chemical loss is masked by dynamical processes.

Arctic ozone loss↗

Interannual Variability of Dust and Ice in the Mars Atmosphere: Comparison of MRO Mars Climate Sounder Retrievals with MGS-TES Limb Sounding Retrievals

Dust and ice play important roles in Martian atmospheric dynamics on all time scales. Dust loading in particular exerts an important control on atmospheric temperatures and thereby on the strength of the atmospheric circulation in any given year. We present the first comparisons of MGS-TES aerosol opacity profiles with MRO-MCS aerosol opacity profiles. While the differences in vertical resolution are significant (a factor of 2), we find good agreement at particular seasons between nightside zonal average dust opacity profiles from the two instruments. Derived water ice opacities are likewise similar but show greater variability.

Mars Climate Sounder (MCS)↗

Dynamical and chemical contributions to variability in microwave limb sounder Arctic stratoshperic column ozone

Analyses of column ozone above 100 hPa (Col100) derived from Upper Atmosphere Research Satellite Microwave Limb Sounder (MLS) data in February/March 1992-1998 show that about half of the interannual variability in Col100 in the Arctic polar vortex in late winter results from interannual variability in chemical loss. A majority of the remainder results from interannual variability in day-to-day dynamical motions including adiabatic warming/cooling and poleward advection of underlying upper tropospheric subtropical air on short timescales, rather than from variations in descent rates and large-scale transport over the winters. The morphology of Col100 from MLS remains very similar to that in the dynamical models even in the years with most chemical ozone loss. The amount and character of day-to-day variability in dynamical models closely follows that in MLS Col100. Although the morphology of and day-to-day variability in Arctic column ozone are controlled by dynamical processes, chemical ozone loss was a major factor in producing both the low values of and the large interannual variability in Arctic column ozone observed during the 1990s.

Arctic ozone loss↗

Photometric Studies of Heat Flow at the Photosphere

Continuum photometry is carried out and the results of comparing these observations with models of photospheric heat flow are described. The main results are: (1) a possible detection of weak bright rings around some spot penumbrae; (2) no evidence is found for large scale photospheric brightness inhomogeneities exceeding 2-3 K which places tighter constraints on models of global scale convection; (3) supergranular scale continuum structures observed across the photosphere appear mainly due to random clumping of granules; (4) the one case observed of a sunspot emergence shows no thermal shadow exceeding 1.5 K rms one day prior to umbra appearance; (5) network and faculae are found to show a small excess brightness even at mu = 1, so detection of faculae at mu = 1 by differential photometry indicates a gentler temperature gradient near tau = 1 in the facular (relative to cell) atmosphere; (6) the limb darkening study shows no significant global variations to within 0.1% rms.

Foukal, P.↗

Scanning imaging absorption spectrometer for atmospheric chartography

The SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY is an instrument which measures backscattered, reflected, and transmitted light from the earth's atmosphere and surface. SCIAMACHY has eight spectral channels which observe simultaneously the spectral region between 240 and 1700 nm and selected windows between 1940 and 2400 nm. Each spectral channel contains a grating and linear diode array detector. SCIAMACHY observes the atmosphere in nadir, limb, and solar and lunar occultation viewing geometries.

Burrows, John P.↗

Tentative identification of formaldehyde in the Martian atmosphere

Solar occultation observations of the Martian atmosphere near the limb of the planet were performed during the Phobos mission by means of the Auguste infrared spectrometer in the ranges 2707-2740 and 5392-5272/cm with a resolving power of approximately = 1300. The spectra exhibit features at 2710 and 2730/cm which have not been identified previously. After applying a set of corrections to the data and examining the spectra of various molecules, we are led to conclude that the best candidate for the above-mentioned features is formaldehyde (CH2O). It was observed in eight of the nine successful occultation sequences, mainly between 8 and 20 km with an average mixing ratio of 0.5 (+0.8, - 0.3) ppm (there are no good data below 8 km). The observations are performed in equatorial spring conditions. The altitude distribution of formaldehyde reveals correlation with the permanent haze opacity.

Korablev, O. I.↗

Study of a Vuilleumier cycle cryogenic refrigerator for detector cooling on the limb scanning infrared radiometer

A program to detect and monitor the presence of trace constituents in the earth's atmosphere by using the Limb Scanning Infrared Radiometer (LSIR) is reported. The LSIR, which makes radiometric measurements of the earth's limb radiance profile from a space platform, contains a detector assembly that must be cooled to a temperature of 65 + or - 2 K. The feasibility of cooling the NASA-type detector package with Vuilleumier (VM) cryogenic refrigerator was investigated to develop a preliminary conceptual design of a VM refrigerator that is compatible with a flight-type LSIR instrument. The scope of the LSIR program consists of analytical and design work to establish the size, weight, power consumption, interface requirements, and other important characteristics of a cryogenic cooler that would meet the requirements of the LSIR. The cryogenic cooling requirements under the conditions that NASA specified were defined. Following this, a parametric performance analysis was performed to define the interrelationships between refrigeration characteristics and mission requirements. This effort led to the selection of an optimum refrigerator design for the LSIR mission.

Russo, S. C.↗

Thermal Emission Spectrometer Results: Mars Atmospheric Thermal Structure and Aerosol Distribution

Infrared spectra returned by the Thermal Emission Spectrometer (TES) are well suited for retrieval of the thermal structure and the distribution of aerosols in the Martian atmosphere. Combined nadir- and limb-viewing spectra allow global monitoring of the atmosphere up to 0.01 mbar (65 km). We report here on the atmospheric thermal structure and the distribution of aerosols as observed thus far during the mapping phase of the Mars Global Surveyor mission. Zonal and temporal mean cross sections are used to examine the seasonal evolution of atmospheric temperatures and zonal winds during a period extending from northern hemisphere mid-summer through vernal equinox (L(sub s) = 104-360 deg). Temperature maps at selected pressure levels provide a characterization of planetary-scale waves. Retrieved atmospheric infrared dust opacity maps show the formation and evolution of regional dust storms during southern hemisphere summer. Response of the atmospheric thermal structure to the changing dust loading is observed. Maps of water-ice clouds as viewed in the thermal infrared are presented along with seasonal trends of infrared water-ice opacity. Uses of these observations for diagnostic studies of the dynamics of the atmosphere are discussed.

Smith, Michael D.↗

Calculation of infrared limb emission by ozone in the terrestrial middle atmosphere. I - Source functions. II - Emission calculations

The departure from LTE in the vibration-rotation bands of ozone in the middle atmosphere is analyzed using two statistical equilibrium models: the energy gap model and the simplified single model. The diurnal variations in the fundamental band source functions nu(1) and nu(3) is determined by the diurnal change in the rate of ozone photolysis by the solar radiation. Source functions are presented for the vibration-rotation bands of ozone that emit in the 9-11-micron spectral interval, over an altitude range of 1-110 km. Results are also reported of the evaluation of the radiative transfer equation incorporating these source functions and energy level populations. Using the results of the two statistical equilibrium models, calculations are carried out of the spectrally integrated limb radiance for the limb viewing geometry for daytime conditions. Results indicate that the interpretation of the measurements of spectrally integrated limb radiance from ozone will be greatly complicated by the breakdown of LTE in the vibration-rotational bands of ozone.

Mlynczak, Martin G.↗

Limb Correction of RGB Composite Imagery for Improved Interpretation

RGB (Red‐Green‐Blue) imagery, created by integrating several spectral channels into one composite image, is currently used by the operational weather community to aid in quick, real‐time analysis of atmospheric processes. However, the limb effect - a result of an increasing optical path length of the absorbing atmosphere between the satellite and the earth as scan angle increases - interferes with the qualitative interpretation of RGB composites at large scan angles. It also makes the comparison of similar products from multiple satellite sensors difficult. Recent work has indicated that correcting for the limb effect in the basic channel imagery using simple statistical relationships greatly improves the utility of the derived RGB imagery. However, it is hypothesized that the limb correction coefficients vary with respect to latitude, season, cloud cover, and surface albedo. This poster will highlight an improved approach to the limb correction of RGB imagery using varying coefficients. The Joint Center for Satellite and Data Assimilation (JCSDA) Community Radiative Transfer Model (CRTM) was used to simulate top of atmosphere brightness temperatures at varying scan angles for infrared channels corresponding to the Aqua and Terra Moderate Resolution Imaging Spectroradiometer (MODIS), Suomi NPP Visible Infrared Imaging Radiometer Suite (VIIRS), and Meteosat‐10 Spinning Enhanced Visible and Infrared Imager (SEVIRI) sensors. A subset of European Center for Medium‐Range Weather Forecasts (ECMWF) temperature, specific humidity, and ozone mixing ratio profiles from March 2013 through February 2014 were used as input to the CRTM. The simulated brightness temperatures were used to determine the best fit slope of the linear relationship between the natural log of the cosine of the scan angle and the difference of the simulated brightness temperature at nadir and on the limb. The correction coefficients were then analyzed for variability with respect to latitude, season, cloud cover, and surface type and used to produce improved limb corrected imagery. Applications of the results will be presented.

Elmer, Nicholas↗

Solar chromospheric modeling based on submillimeter limb brightness profile

A method of modeling the solar chromosphere is developed, based on submillimeter continuum observations of the solar limb. Submillimeter radiation from the solar limb emanates from the chromosphere in local thermodynamic equilibrium, making it an important chromospheric diagnostic. Also, the use of high-resolution limb profiles allows for atmospheric modeling independent of gravitational hydrostatic equilibrium. The chromospheric model is constructed to match high-resolution solar limb profiles at 30, 50, 100, and 200 microns, determined by an occultation of the solar limb observed from the Kuiper Airborne Observatory during the total solar eclipse of July 31, 1981. This matching is achieved by 'stretching' the solar model atmosphere of Vernazza, Avrett, and Loesser (1981) vertically out of hydrostatic equilibrium, while maintainingn its vertical temperature-optical depth profile.

Hermans, L. M.↗

Line mixing in infrared atmospheric spectra

The phenomenon of line mixing in IR vibration-rotation spectra and its impact on atmospheric transmission and radiative transfer is discussed. Laboratory spectra exhibiting line mixing in both Q-branch and R-branch spectra of CO2 are examined. Methods for the calculation of line mixing in atmospheric spectra are discussed, including methods for dealing with temperature dependencies. Observations of line mixing in both limb and nadir viewing atmospheric spectra are presented.

Strow, L. Larrabee↗

Atmosphere and climate studies of Mars using the Mars Observer pressure modulator infrared radiometer

Studies of the climate and atmosphere of Mars are limited at present by a lack of meteorological data having systematic global coverage with good horizontal and vertical resolution. The Mars Observer spacecraft in a low, nearly circular, polar orbit will provide an excellent platform for acquiring the data needed to advance significantly our understanding of the Martian atmosphere and its remarkable variability. The Mars Observer pressure modulator infrared radiometer (PMIRR) is a nine-channel limb and nadir scanning atmospheric sounder which will observe the atmosphere of Mars globally from 0 to 80 km for a full Martian year. PMIRR employs narrow-band radiometric channels and two pressure modulation cells to measure atmospheric and surface emission in the thermal infrared. PMIRR infrared and visible measurements will be combined to determine the radiative balance of the polar regions, where a sizeable fraction of the global atmospheric mass annually condenses onto and sublimes from the surface. Derived meteorological fields, including diabatic heating and cooling and the vertical variation of horizontal winds, are computed from the globally mapped fields retrieved from PMIRR data.

Mccleese, D. J.↗

Ozone Temperature Correlations in the Upper Stratosphere as a Measure of Chlorine Content

We use data from the Nimbus-7 Limb Infrared Monitor of the Stratosphere (LIMS) for the 1978-1979 period together with data from the Upper Atmosphere Research Satellite Microwave Limb Sounder (UARS MLS) for the years 1993 to 1999, the Aura MLS for the years 2004 to 2011, and the Aura High Resolution Infrared Limb Sounder (HIRDLS) for the years 2005 to 2007 to examine ozone-temperature correlations in the upper stratosphere. Our model simulations indicate that the sensitivity coefficient of the ozone response to temperature (Delta ln(O3)/Delta.(l/T)) decreases as chlorine has increased in the stratosphere and should increase in the future as chlorine decreases. The data are in agreement with our simulation of the past. We also find that the sensitivity coefficient does not change in a constant-chlorine simulation. Thus the change in the sensitivity coefficient depends on the change in chlorine, but not on the change in greenhouse gases. We suggest that these and future data can be used to track the impact of chlorine added to the stratosphere and also to track the recovery of the stratosphere as chlorine is removed under the provisions of the Montreal Protocol.

Stolarski, Richard S.↗

Microwave limb sounder

Trace gases in the upper atmosphere can be measured by comparing spectral noise content of limb soundings with the spectral noise content of cold space. An offset Cassegrain antenna system and tiltable input mirror alternately look out at the limb and up at cold space at an elevation angle of about 22. The mirror can also be tilted to look at a black body calibration target. Reflection from the mirror is directed into a radiometer whose head functions as a diplexer to combine the input radiation and a local ocillator (klystron) beam. The radiometer head is comprised of a Fabry-Perot resonator consisting of two Fabry-Perot cavities spaced a number of half wavelengths apart. Incoming radiation received on one side is reflected and rotated 90 deg in polarization by the resonator so that it will be reflected by an input grid into a mixer, while the klystron beam received on the other side is also reflected and rotated 90 deg, but not without passing some energy to be reflected by the input grid into the mixer.

Gustincic, J. J.↗

Atmospheric Measurements by the MLS Experiments: Results from UARS and Plans for EOS

The Microwave Limb Sounder (MLS) on the Upper Atmosphere Research Satellite (UARS) has provided measurements of O(sub 3), H(sub 2)O, CIO, SO(sub 2), HNO(sub 3), temperature and pressure in Earth's atmosphere. These measurements are made near-globally both dat and night and are not degraded by the presence of aerosols, cirrus or polar sratospheric clouds.

Microwave Limb Sounder MLS Upper Atmosphere Resear↗