Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atomic Frequency Standard”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Design concept for the microwave interrogation structure in PARCS

In this paper we will describe key aspects of the conceptual design of the microwave interrogation structure in the laser-cooled cesium frequency standard that is part of the Primary Atomic Reference Clock in Space (PARCS) experiment.

frequency standard phase shift microwave cavity↗

Mission definition study for a VLBI station utilizing the Space Shuttle

The uses of the Space Shuttle transportation system for orbiting VeryLong-Baseline Interferometry (OVLBI) were examined, both with respect to technical feasibility and its scientific possibilities. The study consisted of a critical look at the adaptability of current technology to an orbiting environment, the suitability of current data reduction facilities for the new technique, and a review of the new science that is made possible by using the Space Shuttle as a moving platform for a VLBI terminal in space. The conclusions are positive in all respects: no technological deficiencies exist that would need remedy, the data processing problem can be handled easily by straightforward adaptations of existing systems, and there is a significant new research frontier to be explored, with the Space Shuttle providing the first step. The VLBI technique utilizes the great frequency stability of modern atomic time standards, the power of integrated circuitry to perform real-time signal conditioning, and the ability of magnetic tape recorders to provide essentially error-free data recording, all of which combine to permit the realization of radio interferometry at arbitrarily large baselines.

Burke, B. F.↗

Physical origin of the frequency shifts in cesium beam frequency standards: Related environmental sensitivity

When observed in a cesium beam frequency standard, the hyperfine transition frequency of the atoms differs slightly from the invariant transition frequency of the unperturbed atoms at rest. The various physical and technical origins of the frequency offsets are stated. They relate to fundamental physical effects, to the method of probing the atomic resonance and to the frequency control of the slaved oscillator. The variation of the frequency offsets under a change of the value of the internal operating characteristics is considered. The sensitivity to a change of the magnetic induction, the microwave power, and the temperature is given. A comparison is made of the sensitivity of cesium beam frequency standards of the commercially available type, making use of magnetic state selection, and of devices under study, in which the state preparation and detection is accomplished optically. The pathways between the external stimuli and the physical origin of the frequency offsets are specified.

Audoin, Claude↗

Performance evaluation of the SAO VLG-11 atomic hydrogen masers

A new generation of frequency standards, the VLG-11 hydrogen maser, has been designed and built at the Smithsonian Astrophysical Observatory (SAO). A comprehensive series of environmental and short-term stability tests on three VLG-11 masers has been completed and evaluated. The test results reported here show substantial improvements over previous hydrogen masers in measured sensitivity to variations in ambient temperature, barometric pressure, and magnetic fields. The maser frequency stability, as represented by the two-sample (Allan) variance, has been measured for averaging times ranging from 1 to 100,00 seconds. The variance is lower than 1 x 10 to the -15th for averaging intervals between 1400 and 20,000 seconds. For times shorter than 4000 seconds, the measured stability data agree remarkably well with theoretical values calculated from thermal noise mechanisms and the 'noise within the linewidth' regime is clearly discernable in the data.

Levine, M. W.↗

Hydrogen-maser frequency standard

Wall shift in frequency of proposed variable-shift maser that is caused by collisions between hydrogen atoms and container walls, could easily be determined, thereby allowing building of frequency standard with accuracy of 1 part in 10 to 14th power.

Reinhardt, V.↗

MIL-STDS and PTTI: What's available and what needs to be done

The systems developer who needs Precise Time and Time Interval (PTTI) capability has relatively little guidance in the form of military standards, particularly for systems using atomic clocks or other sources of very precise time and frequency. The existing standards, including MIL-STD-188-115, MIL-F-2991(EC), and DOD-STD-1399 are discussed. These documents were written several years ago and do not always reflect current practice or take advantage of more recent technology improvements. User needs have also changed over the years and some of those needs such as more detailed time codes are not being met. We will summarize what's available and what's good and bad about it. The second part will make suggestions about what should be done in the future to promote and facilitate good PTTI design practice. Topics will include clock performance parameters, environmental considerations, time codes, signal isolation, and time dissemination.

Murray, James A.↗

Relating the Hadamard Variance to MCS Kalman Filter Clock Estimation

The Global Positioning System (GPS) Master Control Station (MCS) currently makes significant use of the Allan Variance. This two-sample variance equation has proven excellent as a handy, understandable tool, both for time domain analysis of GPS cesium frequency standards, and for fine tuning the MCS's state estimation of these atomic clocks. The Allan Variance does not explicitly converge for the nose types of alpha less than or equal to minus 3 and can be greatly affected by frequency drift. Because GPS rubidium frequency standards exhibit non-trivial aging and aging noise characteristics, the basic Allan Variance analysis must be augmented in order to (a) compensate for a dynamic frequency drift, and (b) characterize two additional noise types, specifically alpha = minus 3, and alpha = minus 4. As the GPS program progresses, we will utilize a larger percentage of rubidium frequency standards than ever before. Hence, GPS rubidium clock characterization will require more attention than ever before. The three sample variance, commonly referred to as a renormalized Hadamard Variance, is unaffected by linear frequency drift, converges for alpha is greater than minus 5, and thus has utility for modeling noise in GPS rubidium frequency standards. This paper demonstrates the potential of Hadamard Variance analysis in GPS operations, and presents an equation that relates the Hadamard Variance to the MCS's Kalman filter process noises.

Hutsell, Steven T.↗

Development of an optically-pumped cesium standard at the Aerospace Corporation

We have initiated a research program to study the performance of compact optically-pumped cesium (Cs) frequency standards, which have potential for future timekeeping applications in space. A Cs beam clock apparatus has been assembled. Basic functions of the frequency standard have been demonstrated. Clock signals are observed with optical pumping schemes using one or two lasers. With two laser pumping, we are able to selectively place up to 80 percent of the atomic population into one of the clock transition states. The observed pattern of clock signal indicates that the velocity distribution of the Cs atoms contributing to the microwave signal is beam-Maxwellian. Thus, in the optically-pumped Cs frequency standards, the entire Cs population in the atomic beam could be utilized to generate the clock signals. This is in contrast to the conventional Cs beam standards where only approx. 1 percent of the atoms in the beam are used. More efficient Cs consumption can lead to improved reliability and increased useful lifetime of the clock. Our preliminary results are summarized in this paper

Yat C. Chan↗

Time scale algorithms for an inhomogeneous group of atomic clocks

Through the past 17 years, the time scale requirements at the National Research Council (NRC) have been met by the unsteered output of its primary laboratory cesium clocks, supplemented by hydrogen masers when short-term stability better than 2 x 10(exp -12)tau(sup -1/2) has been required. NRC now operates three primary laboratory cesium clocks, three hydrogen masers, and two commercial cesium clocks. NRC has been using ensemble averages for internal purposes for the past several years, and has a realtime algorithm operating on the outputs of its high-resolution (2 x 10(exp -13) s at 1 s) phase comparators. The slow frequency drift of the hydrogen masers has presented difficulties in incorporating their short-term stability into the ensemble average, while retaining the long-term stability of the laboratory cesium frequency standards. We report on this work on algorithms for an inhomogeneous ensemble of atomic clocks, and on our initial work on time scale algorithms that could incorporate frequency calibrations at NRC from the next generation of Zacharias fountain cesium frequency standards having frequency accuracies that might surpass 10(exp -15), or from single-trapped-ion frequency standards (Ba+, Sr+,...) with even higher potential accuracies. The requirements for redundancy in all the elements (including the algorithms) of an inhomogeneous ensemble that would give a robust real-time output of the algorithms are presented and discussed.

Jacques, C.↗

Lamp reliability studies for improved satellite rubidium frequency standard

In response to the premature failure of Rb lamps used in Rb atomic clocks onboard NAVSTAR GPS satellites experimental and theoretical investigations into their failure mechanism were initiated. The primary goal of these studies is the development of an accelerated life test for future GPS lamps. The primary failure mechanism was identified as consumption of the lamp's Rb charge via direct interaction between Rb and the lamp's glass surface. The most effective parameters to accelerate the interaction between the Rb and the glass are felt to be RF excitation power and lamp temperature. Differential scanning calorimetry is used to monitor the consumption of Rb within a lamp as a function of operation time. This technique yielded base line Rb consumption data for GPS lamps operating under normal conditions.

Frueholz, R. P.↗

Status of local oscillators for operating ultra-high resolution frequency discriminators as frequency standards

The operation of new improved frequency standards based on new ultra-high-resolution frequency discriminators requires high stability local, or 'flywheel' oscillators. We review the spectral density of phase fluctuations of existing flywheel oscillators and the related time domain frequency stability of new and proposed cryogenically cooled oscillators suitable for this application. Presently used devices include the quartz crystal oscillator, the room-temperature actively oscillating atomic hydrogen (H) maser, and the superconducting maser oscillator. Future devices include the cryogenic H-maser and other cryogenic devices using resonators of superconducting metal or solid crystalline sapphire. The relation of the phase spectral density of these devices to the characteristics of present and proposed frequency discriminators based on trapped cooled ions and cold atoms is discussed in terms of their operation as frequency standards.

Vessot, R. F. C.↗

Phase modulation for reduced vibration sensitivity in laser-cooled clocks in space

The standard interrogation technique in atomic beam clocks is square-wave frequency modulation (SWFM), which suffers a first order sensitivity to vibrations as changes in the transit time of the atoms translates to perceived frequency errors. Square-wave phase modulation (SWPM) interrogation eliminates sensitivity to this noise.

frequency standard frequency modulation phase modu↗

Frequency shifts in a rubidium frequency standard due to coupling to another standard

Highly reliable timing system, such as used on board satellites, may incorporate a hot standby atomic clock besides the active one. RF couplings between them may affect the performance of the active clock. The effect of such couplings between two rubidium atomic clocks was investigated, and it was found that they will add an oscillatory term to the Allan Variance of the active clock, degrading its frequency stability, and that under certain circumstances they may also shift the active clock's operating frequency. These two effects are discussed in detail, and the level of isolation required to render them negligible is established.

Jaduszliwer, Bernardo↗

Light shift measurements in a Cesium Fountain without the use of mechanical shutters

We present measurements confirming operation of a cesium fountain frequency standard with light shift below 10^-15 (and with evidence suggesting it is several orders of magnitude below this level) but without the use of mechanical shutters. Suppression of the light shift is realized using a master-slave laser configuration by reducing the overall optical power delivered to the physics package as well as spoiling the injection of the slave, causing it to lase far off resonance (1-2 nm) as proposed by the authors several years ago [l]. In the absence of any mitigation, this (AC Stark) shift, due to near-resonant laser light reaching the atoms during their microwave interrogation period, is the largest shift in such frequency standards (2x10^-11 for Our fountain). Mechanical shutters provided adequate light attenuation but have been prone to failure.

light shift measurements↗