Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atomic Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Visualizing Materials Chemistry at Atomic Resolution

Analytical electron microscopy—empowered by advances in electron optics and detectors—is poised to radically transform the understanding of the complex phenomena arising from atomic and electronic structure in materials chemistry. In their Feature article, Sergio I. Sanchez, Matthew W. Small, Shankar Sivaramakrishnan, Jianguo Wen, Jian-Min Zuo, and Ralph G. Nuzzo of the University of Illinois Urbana-Champaign discuss these recent advances in depth. The cover shows a rendering of an electron beam probing the atomic structure of a metal nanoparticle. In the background is an STEM image of an Au nanoparticle illustrating the capacities of state-of-the-art electron microscopy as a characterization tool in materials chemistry. Furthermore, the cover art is courtesy of Alex Jerez of the Imaging Technology Group at the Beckman Institute, University of Illinois Urbana-Champaign.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Signatures of distinct impurity configurations in atomic-resolution valence electron-energy-loss spectroscopy: Application to graphene

The detection and identification of impurities and other point defects in materials is a challenging task. Signatures for point defects are typically obtained using spectroscopies without spatial resolution. Here in this paper, we demonstrate the power of valence electron-energy-loss spectroscopy (VEELS) in an aberration-corrected scanning transmission-electron microscope (STEM) to provide energy-resolved and atomically resolved maps of electronic excitations of individual impurities which, combined with theoretical simulations, yield unique signatures of distinct bonding configurations of impurities. We report VEELS maps for isolated Si impurities in graphene, which are known to exist in two distinct configurations. We also report simulations of the maps, based on density functional theory and dynamical scattering theory, which agree with and provide direct interpretation of observed features. We show that theoretical VEELS maps exhibit distinct and unambiguous signatures for the threefold- and fourfold-coordinated configurations of Si impurities in different energy-loss windows, corresponding to impurity-induced bound states, resonances, and antiresonances. With the advent of new monochromators and detectors with high energy resolution and low signal-to-noise ratio, the present work ushers an atomically resolved STEM-based spectroscopy of individual impurities as an alternative to conventional spectroscopies for probing impurities and defects.

36 MATERIALS SCIENCE↗

Detection of defects in atomic-resolution images of materials using cycle analysis

The automated detection of defects in high-angle annular dark-field Z-contrast (HAADF) scanning-transmission-electron microscopy (STEM) images has been a major challenge. Here, we report an approach for the automated detection and categorization of structural defects based on changes in the material’s local atomic geometry. The approach applies geometric graph theory to the already-found positions of atomic-column centers and is capable of detecting and categorizing any defect in thin diperiodic structures (i.e., “2D materials”) and a large subset of defects in thick diperiodic structures (i.e., 3D or bulk-like materials). Despite the somewhat limited applicability of the approach in detecting and categorizing defects in thicker bulk-like materials, it provides potentially informative insights into the presence of defects. The categorization of defects can be used to screen large quantities of data and to provide statistical data about the distribution of defects within a material. This methodology is applicable to atomic column locations extracted from any type of high-resolution image, but here we demonstrate it for HAADF STEM images.

36 MATERIALS SCIENCE↗

Spectroscopy of the extreme ultraviolet dayglow at 6.5A resolution - Atomic and ionic emissions between 530 and 1240A

EUV spectra (530-1500A) of the day airglow in up, down and horizontal aspect orientations have been obtained with 6.5A resolution and a limiting sensitivity of 5R from a rocket experiment. Below 834A the spectrum is rich in previously unobserved OII transitions connecting with 4S(0), 2D(0), and 2P(0) states. Recent broad-band photometric observations of geocoronal HeI 584A emission in terms of the newly observed OII emissions are shown. The OI 989A and OI 1304A emissions exhibit similar dependence on altitude and viewing geometry with the OI 989A brightness 1/15 that of OI 1340. Emission at 1026A is identified as geocoronal HI Lyman beta rather than OI multiplet emission and observed intensities agree well with model estimates. An unexpectedly high NI 1200/NI 1134A brightness ratio is evidence of a significant contribution from photodissociative excitation of N2 to the NI 1200A source function.

Gentieu, E. P.↗

Contrast Reversal in Atomic-Resolution Chemical Mapping

We report an unexpected result obtained using chemical mapping on the new, aberration corrected Nion UltraSTEM at Daresbury. Using different energy windows above the L{sub 2,3} edge in <011> silicon to map the position of the atomic columns we find a contrast reversal which produces an apparent and misleading translation of the silicon columns. Using simulations of the imaging process, we explain the intricate physical mechanisms leading to this effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Understanding Atom Probe Tomography of Oxide-Supported Metal Nanoparticles by Correlation with Atomic Resolution Electron Microscopy and Field Evaporation Simulation

Metal-dielectric composite materials, specifically metal nanoparticles supported on or embedded in metal oxides, are widely used in catalysis. The accurate optimization of such nanostructures warrants the need for detailed three-dimensional characterization. Atom probe tomography is uniquely capable of generating sub-nanometer structural and compositional data with part-per-million mass sensitivity, but there are reconstruction artifacts for composites containing materials with strongly differing fields of evaporation, as for oxide-supported metal nanoparticles. By correlating atom probe tomography with scanning transmission electron microscopy for Au nanoparticles embedded in an MgO support, deviations from an ideal topography during evaporation are demonstrated directly, and correlated with compositional errors in the reconstructed data. Finite element simulations of the field evaporation process confirm that protruding Au nanoparticles will evolve on the tip surface, and that evaporation field variations lead to an inaccurate assessment of the local composition, effectively lowering the spatial resolution of the final reconstructed dataset. Cross-correlating the experimental data with simulations results in a more detailed understanding of local evaporation aberrations during APT analysis of metal-oxide composites, paving the way towards a more accurate three-dimensional characterization of this technologically important class of materials.

Environmental Molecular Sciences Laboratory↗

In situ atomic-resolution imaging of water vapor–driven multistep oxidation dynamics in strontium cobaltite

Understanding how water vapor interacts with transition metal oxides (TMOs) is critical for tailoring material properties to improve performance and enable new technologies. Despite extensive research efforts, atomic-scale mechanisms underpinning dynamic reactions and reaction-induced phase transitions remain elusive. Here, we use in situ environmental transmission electron microscopy to investigate how water vapor oxidizes vacancy-ordered SrCoO 2.5 at moderately elevated temperatures, demonstrating that water molecules can initiate oxidation more effectively than oxygen under comparable conditions. We discover a distinct “staging” behavior during the oxidation process: A fully ordered intermediate phase, SrCoO 2.75 , forms before transitioning into a near-perovskite SrCoO 3−δ . In addition, antiphase boundaries, originating at step terraces of SrTiO 3 , alleviate strain by creating reversible nanoscale “gaps” during lattice contraction under oxidation, providing a pathway for preserving structural integrity throughout redox cycling. This work provides atomic-level guidance for engineering TMOs by leveraging water vapor to control their redox behavior and tailor functional properties.

Science & Technology - Other Topics↗

Metal ions and flexibility in a viral RNA pseudoknot at atomic resolution

Many pathogenic viruses use programmed -1 ribosomal frameshifting to regulate translation of their structural and enzymatic proteins from polycistronic mRNAs. Frameshifting is commonly stimulated by a pseudoknot located downstream from a slippery sequence, the latter positioned at the ribosomal A and P sites. We report here the structures of two crystal forms of the frameshifting RNA pseudoknot from beet western yellow virus at resolutions of 1.25 and 2.85 {angstrom}. Because of the very high resolution of 1.25 {angstrom}, ten mono- and divalent metal ions per asymmetric unit could be identified, giving insight into potential roles of metal ions in stabilizing the pseudoknot. A magnesium ion located at the junction of the two pseudoknot stems appears to play a crucial role in stabilizing the structure. Because the two crystal forms exhibit mostly unrelated packing interactions and local crystallographic disorder in the high-resolution form was resolvable, the two structures offer the most detailed view yet of the conformational preference and flexibility of an RNA pseudoknot.

59 BASIC BIOLOGICAL SCIENCES↗

Simulating the mechanisms of serrated flow in interstitial alloys with atomic resolution over diffusive timescales

Abstract The Portevin-Le Chatelier (PLC) effect is a phenomenon by which plastic slip in metallic materials becomes unstable, resulting in jerky flow and the onset of inhomogeneous deformation. The PLC effect is thought to be fundamentally caused by the dynamic interplay between dislocations and solute atoms. However, this interplay is almost always inaccessible experimentally due to the extremely fine length and time scales over which it occurs. In this paper, simulations of jerky flow in W-O interstitial solid solutions reveal three dynamic regimes emerging from the simulated strain rate-temperature space: one resembling standard solid solution strengthening, another one mimicking solute cloud formation, and a third one where dislocation/solute coevolution leads to jerky flow as a precursor of dynamic strain aging. The simulations are carried out in a stochastic framework that naturally captures rare events in a rigorous manner, providing atomistic resolution over diffusive time scales using no adjustable parameters.

36 MATERIALS SCIENCE↗

Atomic-resolution visualization and doping effects of complex structures in intercalated bilayer graphene

Molecules intercalating two-dimensional materials form complex structures that have been characterized primarily by spatially averaged techniques. In this work, we use aberration-corrected scanning transmission electron microscopy and density-functional-theory (DFT) calculations to study the atomic structure of bilayer graphene (BLG) and few-layer graphene (FLG) intercalated with FeC l 3 . In BLG, we discover two distinct intercalated structures that we identify as monolayer FeC l 3 and monolayer FeC l 2 . The two structures are separated by atomically sharp boundaries and induce large free-carrier densities on the order of 10 13 c m - 2 in the graphene layers. In FLG, we observe multiple FeC l 3 layers stacked in a variety of possible configurations with respect to one another. Lastly, we find that the microscope's electron beam can convert the FeC l 3 monolayer into FeOCl monolayers in a rectangular lattice. These results reveal the need for a combination of atomically resolved microscopy, spectroscopy, and DFT calculations to identify intercalated structures and study their properties.

36 MATERIALS SCIENCE↗

Vortex Beams for Atomic Resolution Dichroism

Vortex beams carrying orbital angular momentum have been produced recently with electron microscopy by interfering an incident electron beam with a grid containing dislocations. Here, we present an analytical derivation of vortex wave functions in reciprocal and real space. We outline their mathematical and physical properties and describe the conditions under which vortex beams can be used in scanning transmission microscopy to measure magnetic properties of materials at the atomic scale.

99 GENERAL AND MISCELLANEOUS↗

Vortex Beams for Atomic Resolution Dichroism

Vortex beams carrying orbital angular momentum have been produced recently with electron microscopy by interfering an incident electron beam with a grid containing dislocations. Here, we present an analytical derivation of vortex wave functions in reciprocal and real space. We outline their mathematical and physical properties and describe the conditions under which vortex beams can be used in scanning transmission microscopy to measure magnetic properties of materials at the atomic scale.

99 GENERAL AND MISCELLANEOUS↗

High resolution atomic force microscopy with an active piezoelectric microcantilever

Active microcantilevers with on-chip sensing and actuation provide significant advantages in tapping mode Atomic Force Microscopy (AFM). Collocated transduction allows for effective manipulation of cantilever dynamics through feedback control, enabling higher scan rates. However, the adjacency of the sensing and actuation electrodes is known to result in a high level of feedthrough, leading to a low imaging resolution. Readout circuit noise further deteriorates the imaging precision. Here, we investigate the noise sources that affect AFM microcantilevers with collocated aluminum nitride (AlN) actuator–sensor pairs. We reported these cantilevers in earlier work and demonstrated that they display a very low level of feedthrough between the actuation and sensing electrodes. We present a high signal-to-noise ratio (SNR) sensing method that enables us to demonstrate high-resolution AFM on a calibration grating with nm-step silicon carbide (SiC) terraces. In conclusion, measuring the Lorentzian response of the cantilever’s Brownian motion with the on-chip active sensor at resonance enables us to calibrate the dynamic stiffness at the first fundamental resonance mode, without utilizing an optical sensor.

47 OTHER INSTRUMENTATION↗

Integrating Novel Microscopy into Battery Research: From Atomic Resolution to In Situ and Functional Imaging

Regardless of their different configurations and chemistries, current energy-storage systems, e.g. Li-ion, Li-S, Li-air, and all-solid-state Li batteries, rely on the use of solid-state ion conducting materials as electrodes and/or electrolytes. Continuous ion hopping from one mobile ion site to adjacent vacancy sites in a crystalline lattice forms the basis for ion conduction in solids. Atomic-scale factors, such as lattice structure and the concentration and distribution of mobile carriers and vacancies, decide the ion conductivity in solids, and thus dictate the rate capability and capacity in batteries.

25 ENERGY STORAGE↗

Atomic Resolution Imaging of Light Elements in a Crystalline Environment using Dynamic Hollow-Cone Illumination Transmission Electron Microscopy

Multiple electron scattering and the nonintuitive nature of image formation with coherent radiation complicate the interpretation of conventional transmission electron microscopy images. Precession of the illuminating beam in transmission electron microscopy (TEM) can lead to more robust and interpretable images with some penalty to image contrast, a technique known as dynamic hollow-cone illumination TEM. Here, we demonstrate direct and robust imaging of light and heavy atoms in a crystalline environment with this technique. This method is similar to the annular bright-field technique in scanning transmission electron microscopy, via the principle of reciprocity. Dynamic hollow-cone illumination TEM is challenging in practice due to sensitivity to the misalignment of the precession axis, microscope objective aperture, and crystal zone axis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Unusual Cu(I)/Ag(I) Coordination of Escherichia Coli CusF As Revealed By Atomic Resolution Crystallography And X-Ray Absorption Spectroscopy

Elevated levels of copper or silver ions in the environment are an immediate threat to many organisms. Escherichia coli is able to resist the toxic effects of these ions through strictly limiting intracellular levels of Cu(I) and Ag(I). The CusCFBA system is one system in E. coli responsible for copper/silver tolerance. A key component of this system is the periplasmic copper/silver-binding protein, CusF. Here the X-ray structure and XAS data on the CusF-Ag(I) and CusF-Cu(I) complexes, respectively, are reported. In the CusF-Ag(I) structure, Ag(I) is coordinated by two methionines and a histidine, with a nearby tryptophan capping the metal site. EXAFS measurements on the CusF-Cu(I) complex show a similar environment for Cu(I). The arrangement of ligands effectively sequesters the metal from its periplasmic environment and thus may play a role in protecting the cell from the toxic ion.

74 ATOMIC AND MOLECULAR PHYSICS↗