Search NASA⌕ Search

SEARCH · Search NASA

Results for “Band emission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Rare Earth Garnet Selective Emitter

Thin film Ho-YAG and Er-YAG emitters with a platinum substrate exhibit high spectral emittance in the emission band (epsilon(sub lambda) approx. = 0.75, sup 4)|(sub 15/2) - (sup 4)|(sub 13/2),for Er-YAG and epsilon(sub lambda) approx. = 0.65, (sup 5)|(sub 7) - (sup 5)|(sub 8) for Ho-YAG) at 1500 K. In addition, low out-of-band spectral emittance, epsilon(sub lambda) less than 0.2, suggest these materials would be excellent candidates for high efficiency selective emitters in thermophotovoltaic (TPV) systems operating at moderate temperatures (1200-1500 K). Spectral emittance measurements of the thin films were made (1.2 less than lambda less than 3.0 microns) and compared to the theoretical emittances calculated using measured values of the spectral extinction coefficient. In this paper we present the results for a new class of rare earth ion selective emitters. These emitters are thin sections (less than 1 mm) of yttrium aluminum garnet (YAG) single crystal with a rare earth substitutional impurity. Selective emitters in the near IR are of special interest for thermophotovoltaic (TPV) energy conversion. The most promising solid selective emitters for use in a TPV system are rare earth oxides. Early spectral emittance work on rare earth oxides showed strong emission bands in the infrared (0.9 - 3 microns). However, the emittance outside the emission band was also significant and the efficiency of these emitters was low. Recent improvements in efficiency have been made with emitters fabricated from fine (5 - 10 microns) rare earth oxide fibers similar to the Welsbach mantle used in gas lanterns. However, the rare earth garnet emitters are more rugged than the mantle type emitters. A thin film selective emitter on a low emissivity substrate such as gold, platinum etc., is rugged and easily adapted to a wide variety of thermal sources. The garnet structure and its many subgroups have been successfully used as hosts for rare earth ions, introduced as substitutional impurities, in the development of solid state laser crystals. Doping, dependent on the particular ion and crystal structure, may be as high as 100 at. % (complete substitution of yttrium ion with the rare earth ion). These materials have high melting points, 1940 C for YAG (Yttrium Aluminum Garnet), and low emissivity in the near infrared making them excellent candidates for a thin film selective emitter. As previously stated, the spectral emittance of a rare earth emitter is characterized by one or more well defined emission bands. Outside the emission band the emittance(absorptance) is much lower. Therefore, it is expected that emission outside the band for a thin film selective emitter will be dominated by the emitter substrate. For an efficient emitter (power in the emission band/total emitted power) the substrate must have low emittance, epsilon(sub S). This paper presents normal spectral emittance, epsilon(sub lambda), measurements of holmium(Ho) and erbium (Er) doped YAG thin film selective emitters at (1500 K), and compares those results with the theoretical spectral emittance.

Lowe, Roland A.↗

Preliminary Assessment of Suomi-NPP VIIRS On-orbit Radiometric Performance

The Visible-Infrared Imaging Radiometer Suite (VIIRS) is a key instrument on-board the Suomi National Polar-orbiting Partnership (NPP) spacecraft that was launched on October 28th 2011. VIIRS was designed to provide moderate and imaging resolution of most of the globe twice daily. It is a wide-swath (3,040 km) cross-track scanning radiometer with spatial resolutions of 370.and 740 m at nadir for imaging and moderate bands, respectively. It has 22 spectral bands covering the spectrum between 0.412 11m and 12.01 11m, including 14 reflective solar bands (RSB), 7 thermal emissive bands (TEB), and 1 day-night band (ON B). VIIRS observations are used to generate 22 environmental data products (EORs). This paper will briefly describe NPP VIIRS calibration strategies performed by the independent government team, for the initial on-orbit Intensive Calibration and Validation (ICV) activities. In addition, this paper will provide an early assessment of the sensor on-orbit radiometric performance, such as the sensor signal to noise ratios (SNRs), dual gain transition verification, dynamic range and linearity, reflective bands calibration based on the solar diffuser (SO) and solar diffuser stability monitor (SOSM), and emissive bands calibration based on the on-board blackbody calibration (OBC). A comprehensive set of performance metrics generated during the pre-launch testing program will be compared to VIIRS on-orbit early performance, and a plan for future cal/val activities and performance enhancements will be presented.

Oudrari, Hassan↗

An Overall Assessment of JPSS-2 VIIRS Radiometric Performance Based on Pre-Launch Testing

The Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the second Joint Polar Satellite System (JPSS) completed its sensor level testing in February 2018. The JPSS-2 (J2) mission is scheduled to launch in 2022 and will be very similar to its two predecessor missions, the Suomi National Polar-orbiting Partnership (SNPP) mission, launched on 28 October 2011 and JPSS-1 (renamed NOAA-20) launched on 18 November 2017. VIIRS instrument has 22 spectral bands covering the spectrum between 0.4 and 12.6 μm: 14 reflective solar bands (RSB), 7 thermal emissive bands (TEB) and one day-night band (DNB). It is a cross-track scanning radiometer capable of providing global measurements through observations at two spatial resolutions, 375 m and 750 m at nadir for the imaging bands and moderate bands, respectively. This paper will provide an overview of J2 VIIRS characterization methodologies and calibration performance during the pre-launch testing phases performed by the National Aeronautics and Space Administration (NASA) VIIRS Characterization Support Team (VCST) to evaluate the at-launch baseline radiometric performance and generate the parameters needed to populate the sensor data record (SDR) Look-Up-Tables (LUTs). Our analysis results confirmed the good performance of J2 VIIRS, in general as good as previous VIIRS instruments and all non-compliances are expected to have low impact on data quality. Key sensor performance metrics include the signal to noise ratio (SNR), radiance dynamic range, reflective and emissive bands calibration performance, polarization sensitivity, spectral performance, response versus scan-angle (RVS) and scattered light response. A set of performance metrics generated during the pre-launch testing program will be compared to both the SNPP and JPSS-1 VIIRS sensors.

Oudrari, Hassan↗

Dependence of ion-cyclotron range of frequencies instabilities on species mix and fast-ion distribution: II. Time evolution

Dedicated DIII-D experiments studied instabilities below the ion cyclotron frequency f ci and at cyclotron harmonics by injecting thirteen different neutral beam populations into plasmas with different thermal compositions of H and D at five different values of toroidal field. The resulting database of 2529 conditions is described in Part 1: Stability. This paper focuses on the temporal evolution. For some beam geometries, the ion cyclotron emission (ICE) is much stronger at the beginning of injection, suggesting the importance of ‘bump-on-tail’ energy drive. Sawtooth crashes cause the emission to cease for some beam types and emission bands, but the opposite effect occurs for others. When unstable, for virtually all conditions and frequency bands, the emission bursts in a cycle reminiscent of predator-prey oscillations. Evidence for nonlinear interaction between ICE harmonics is observed. Strongly unstable modes typically appear within 1 ms from the start of beam injection and often decay within 0.1 ms when the beam turns off, but both the initial rise and final decay of the mode power exhibit a wide variety of behavior.

electromagnetic ion cyclotron instabilities↗

Upper limits on spacecraft-induced ultraviolet emissions from the Space Shuttle (STS-61C)

Results are reported from a search for band emission of N2, OH, O2, and NO in nightglow spectra obtained in January 1986 with the Johns Hopkins UV background experiment (UVX) flown on the Space Shuttle Columbia (STS-61C) at an altitude of 330 km. The experiment consisted of two Ebert monochromators spanning the spectral range from 1200 to 1700 A at 17-A resolution and from 1600 to 3200 A at 29-A resolution. UV shuttle glow emission was not detected at a 330-km altitude with 3-sigma upper limits based on counting statistics on N2 LBH, O2 Herzberg, and NO delta, gamma, and beta of 5.3, 4.5, 0.6, 0.7, and 3.5 R of total band emission, respectively. The upper limit on the OH (A 2Sigma-u(+) - X2Pi)(0,0) and (1,0) band emission is 0.1 R. The branching ratio of the NO C2Pi state to the A2Sigma(+) state was determined from the UVX experiment by measuring the ratio of the total emission rate from the delta-band system to that of the gamma-band system. The branching ratio for the C2Pi state to the A2Sigma(+) state is 0.37 +/-0.03.

Morrison, D.↗

Identification of Gas Phase PAHs in Absorption Towards Protostellar Sources

The infrared emission bands (also known as the UIR bands.) have recently been observed in absorption at 3.25 micrometers in the ices surrounding a few proto-stellar objects at 11.2 micrometers in MonR2, and at 6.2 micrometers towards two sources near the galactic center. The UIR bands have been observed in emission for many years, but identifying these bands has proven to be both difficult and contentious as no one has yet found a single material that provides a good match to the features. However, most investigators agree that some form of carbon-based material with aromatic bonds is the most likely candidate, and many arguments favor free molecules (polycyclic aromatic hydrocarbons, PAHs) as the carriers of at least the narrow emission bands. Since the emission arises not from a single molecule but from a family of molecules, identifying which PAHs are contributing to the infrared emission bands is difficult. The identification is further complicated by the fact that the emission at short wavelengths is dominated by small molecules while at long wavelengths it is dominated by large molecules. Thus, for example, the emission at 3.3 micrometers is from a different mix of molecules than those which produce the 11.2 micrometer band. To complicate matters further, the molecular mix includes both neutral and ionic species. In absorption, the same mixture of molecules contributes at all wavelengths and the molecules should be neutral, potentially simplifying comparisons with lab data. Also, absorption strengths measured in the lab are directly applicable to interstellar absorption bands without the need to model an emission spectrum of an unknown mixture of ionized and neutral PAHs. In this paper we show that a mixture of argon matrix isolated PAH molecules can reproduce the 3.25 micrometers absorption band seen in the ISO SWS spectra of four embedded Infrared sources, S140 IRS1, AFGL 2591, Elias 29, and AFGL 989. In section 2 we describe the ISO SWS data analysis and in section 3 discuss the results.

Bregman, Jesse D.↗

Model Development for MODIS Thermal Band Electronic Crosstalk

MODerate-resolution Imaging Spectroradiometer (MODIS) has 36 bands. Among them, 16 thermal emissive bands covering a wavelength range from 3.8 to 14.4 m. After 16 years on-orbit operation, the electronic crosstalk of a few Terra MODIS thermal emissive bands developed substantial issues that cause biases in the EV brightness temperature measurements and surface feature contamination. The crosstalk effects on band 27 with center wavelength at 6.7 m and band 29 at 8.5 m increased significantly in recent years, affecting downstream products such as water vapor and cloud mask. The crosstalk effect is evident in the near-monthly scheduled lunar measurements, from which the crosstalk coefficients can be derived. The development of an alternative approach is very helpful for independent verification.In this work, a physical model was developed to assess the crosstalk impact on calibration as well as in Earth view brightness temperature retrieval. This model was applied to Terra MODIS band 29 empirically to correct the Earth brightness temperature measurements. In the model development, the detectors nonlinear response is considered. The impact of the electronic crosstalk is assessed in two steps. The first step consists of determining the impact on calibration using the on-board blackbody (BB). Due to the detectors nonlinear response and large background signal, both linear and nonlinear coefficients are affected by the crosstalk from sending bands. The second step is to calculate the effects on the Earth view brightness temperature retrieval. The effects include those from affected calibration coefficients and the contamination of Earth view measurements. This model links the measurement bias with crosstalk coefficients, detector non-linearity, and the ratio of Earth measurements between the sending and receiving bands. The correction of the electronic cross talk can be implemented empirically from the processed bias at different brightness temperature. The implementation can be done through two approaches. As routine calibration assessment for thermal infrared bands, the trending over select Earth scenes is processed for all the detectors in a band and the band averaged bias is derived at a certain time. In this case, the correction of an affected band can be made using the regression of the model with band averaged bias and then corrections of detector differences are applied. The second approach requires the trending for individual detectors and the bias for each detector is used for regression with the model. A test using the first approach was made for Terra MODIS band 29 with the biases derived from long-term trending of brightness temperature over ocean and Dome-C.

Chang, Tiejun↗

The MODIS TEBs Calibration and Look-up Table Delivery Process for Collections 6 and 6.1

MODIS is a cross-track, whisk-broom scanning imaging radiometer with a double-sided scan mirror that collects data in 36 spectral bands. Sixteen of the 36 MODIS spectral bands are Thermal Emissive Bands (TEBs) whose spectral wavelengths range from 3.5 μm to 14.4 μm. The TEB detectors are calibrated on a scan-by-scan basis using a quadratic calibration algorithm by observing both the MODIS on-board blackbody (BB) and a background space view reference. Blackbody warm-up/cool-down (WUCD) events are performed quarterly to track on-orbit changes associated with the TEB detectors' non-linearity. Following each WUCD, the calibration coefficients in the quadratic algorithm, and their associated contributions to the total uncertainty, are updated and delivered through separate look-up tables (LUTs) when all update criteria are met. Afterwards, the LUTs are incorporated into the Level 1B (L1B) product. Since the Terra MODIS mission began, a steady increase in electronic cross-talk has been observed for TEBs 27{30. Starting from Collection 6.1, an algorithm has been applied using correction coefficients derived from regularly-scheduled lunar observations, with the correction LUT update dependent on its impact on the current L1B product. The MODIS Characterization Support Team (MCST) has established a comprehensive set of procedures to assure timely and accurate LUT updates, and maintain the quality and accuracy of the L1B and science products. This paper provides an overview of the current calibration and LUT delivery process for the MODIS TEBs in Collections 6 and 6.1.

MODIS↗

Analysis of chorus emissions at Jupiter

The emissions in the chorus frequency band which were detected on the Voyager 1 inbound pass between about ten and six Jupiter radii are surveyed. An overview of the plasma and wave observations during the inbound pass is presented and the spatial regions in which chorus band signals were observed are discussed. A series of wide-band frequency-time frames which characterize the onset of two observed intervals of chorus band activity is displayed. A detailed examination is made of the spectra for rising chorus which sweeps upward in frequency from 0.2 to 0.5 times the electron cyclotron frequency f(c). Two temporally successive wide-band frames in which several types of chorus band emissions were observed are discussed. The spatial morphology of chorus is discussed in terms of the electron energies which resonate with whistler mode waves. A recent theory of chorus generation is reviewed along with theories and a model explaining the narrow-band emissions above f(c)/2.

Coroniti, F. V.↗

Role of defects in ultra-high gain in fast planar tin gallium oxide UV-C photodetector by MBE

Here we report ultra-high responsivity of epitaxial (Sn x Ga 1–x ) 2 O 3 (TGO) Schottky UV-C photodetectors and experimentally identified the source of gain as deep-level defects, supported by first principles calculations. Epitaxial TGO films were grown by plasma-assisted molecular beam epitaxy on (–201) oriented n-type β-Ga 2 O 3 substrates. Fabricated vertical Schottky devices exhibited peak responsivities as high as 3.5 ×10 4 A/W at –5 V applied bias under 250 nm illumination with sharp cutoff shorter than 280 nm and fast rise/fall time in milliseconds order. Hyperspectral imaging cathodoluminescence (CL) spectra were examined to find the mid-bandgap defects, the source of this high gain. Irrespective of different tin mole fractions, the TGO epilayer exhibited extra CL peaks at the green band (~2.20 eV) not seen in β-Ga 2 O 3 along with enhancement of the blue emission-band (~2.64 eV) and suppression of the UV emission-band. Based on hybrid functional calculations of the optical emission expected for defects involving Sn in β-Ga 2 O 3 , V Ga –Sn complexes are proposed as potential defect origins of the observed green and blue emission-bands. Such complexes behave as acceptors that can efficiently trap photogenerated holes and are predicted to be predominantly responsible for the ultra-high photoconductive gain in the Sn-alloyed Ga 2 O 3 devices by means of thermionic emission and electron tunneling. Regenerating the V Ga –Sn defect complexes by optimizing the growth techniques, we have demonstrated a planar Schottky UV-C photodetector of the highest peak responsivity.

36 MATERIALS SCIENCE↗

3.3 and 11.3 micron images of HD 44179 - Evidence for an optically thick polycyclic aromatic hydrocarbon disk

Images of HD 44179 (the Red Rectangle) obtained in the 3.3 and 11.3 micron emission bands show two different spatial distributions. The 3.3 micron band image is centrally peaked and slightly extended N-S while the 11.3 micron image shows a N-S bipolar shape with no central peak. If the 3.3 micron band image shows the intrinsic emission of the 11.3 micron band, then the data suggest absorption of the 11.3 micron emission near the center of HD 44179 by a disk with an optical depth of about one, making HD 44179 the first object in which the IR emission bands have been observed to be optically thick. Since there is no evidence of absorption of the 3.3 micron emission band by the disk, the absorption cross section of the 3.3 micron band must be substantially less than for the 11.3 micron band. Since the 3.3 and 11.3 micron bands are thought to arise from different size PAHs, the similar N-S extents of the two images implies that the ratio of small to large PAHs does not change substantially with distance from the center.

Bregman, Jesse D.↗

Resonance plasmonic coupling: selective enhancement of band edge emission over trap state emission of CdSe quantum dots

The photoluminescence properties of quantum dots (QDs) are often enhanced by eliminating surface trap states through chemical methods. Alternatively, a physical approach is presented here for improving photoluminescence purity in QDs by employing frequency-specific plasmon resonance coupling. Emitter-bound plasmonic hybrids are designed by electrostatically binding negatively charged QDs in water to positively charged gold nanoparticles having a thin polymer coating. Herein, two types of QDs are used: (i) bare CdSe, which exhibits both band edge and trap state emission, and (ii) CdSe overcoated with a ZnS shell (CdSe/ZnS) devoid of trap state emission. Tuning the extinction spectrum of the plasmonic system to match the band edge emission of CdSe enables the selective enhancement of band edge emission over trap state emission. Excellent match in the extinction spectrum of the gold nanoparticle with both, experimentally calculated photoluminescence enhancement factor and theoretically calculated radiative rate enhancement signifies the role of frequency-specific plasmon resonance coupling. Plasmon-coupled photoluminescence of CdSe/ZnS is further investigated by varying the number density of emitter on the surface of plasmonic nanoparticle. An enhancement in the photoluminescence is observed at a lower emitter density of CdSe/ZnS and the photoluminescence enhancement factor closely follows the plasmon resonance. However, photoluminescence quenching occurs with an increase in CdSe/ZnS due to plasmon-assisted nonradiative energy transfer between nearby QDs, as indicated by a red shift in the PL maximum. These studies establish that resonance plasmonic coupling is a convenient physical strategy for tuning the intrinsic photoluminescence properties of QDs for various optoelectronic applications.

Paul, Livin↗

Multicolor multifocal 3D microscopy using in-situ optimization of a spatial light modulator

Abstract Multifocal microscopy enables high-speed three-dimensional (3D) volume imaging by using a multifocal grating in the emission path. This grating is typically designed to afford a uniform illumination of multifocal subimages for a single emission wavelength. Using the same grating for multicolor imaging results in non-uniform subimage intensities in emission wavelengths for which the grating is not designed. This has restricted multifocal microscopy applications for samples having multicolored fluorophores. In this paper, we present a multicolor multifocal microscope implementation which uses a Spatial Light Modulator (SLM) as a single multifocal grating to realize near-uniform multifocal subimage intensities across multiple wavelength emission bands. Using real-time control of an in-situ-optimized SLM implemented as a multifocal grating, we demonstrate multicolor multifocal 3D imaging over three emission bands by imaging multicolored particles as well as Escherichia coli ( E. coli ) interacting with human liver cancer cells, at $$\sim 2.5$$ ∼ 2.5 multicolor 3D volumes per second acquisition speed. Our multicolor multifocal method is adaptable across SLM hardware, emission wavelength band locations and number of emission bands, making it particularly suited for researchers investigating fast processes occurring across a volume where multiple species are involved.

47 OTHER INSTRUMENTATION↗

Band limited emission with central frequency around 2 Hz accompanying powerful cyclones

It has been found that powerful cyclones are proceeded, accompanied and followed by narrow band electromagnetic emission with central frequency around 2 Hz. It is shown that the signal from this emission is unique and clearly distinguishable from known types of magnetic pulsations, spectra of local thunderstorms, and signals from industrial sources. This emission was first observed during an unusually powerful cyclone with tornadoes in the western European part of the Soviet Union, which passed by the observatory of Borok from south to north-east. The emission has been confirmed by analysis of similar events in Antarctica. The phenomenon described presents a new aspect of interactions of processes in the lower atmosphere and the ionosphere.

Troitskaia, V. A.↗

Variability in Comet P/Swift-Tuttle

Spatial profiles of the coma of Comet P/Swift-Tuttle perpendicular to the projected Sun-comet line were obtained for the emission bands of CN, C2, and C3 as well as for two continuum bands from spectrophotometric observations taken from Oct. 5 to 8, 1992. The intensities were converted into emissivities per sq km in the cases of the continua and into column densities for the emission band profiles. Spatial and temporal variabilities have been found in all five investigated components, which are consistent with the rotational period of the nucleus determined from the observations of the comet during its last perihelion passage in 1862. The emission band profiles were fitted with the vectorial model and the production rates of CN, C2, and C3 were determined. One half of the profiles was fitted adequately under steady state conditions for the production rate in a first approximation, whereas the other half showed prominent bumps, which could only be explained by introducing a time-dependent production rate. Further investigations showed evidence for the presence of gaseous as well as dust jets in the coma, which indicated the presence of at least two active areas on the surface of the nucleus. The projected radial expansion velocities of two different features were determined to be (430 +/- 100) and (460 +/- 100) m/sec, respectively.

Schulz, Rita↗

ELM: Europa Luminescence Microscope

The Europa Luminescence Microscope (ELM) is an automated fluorescence and bright-field microscope designed to meet key objectives defined in the 2016 NASA Europa Lander Study Report, including the identification and characterization of morphological biosignatures. ELM’s heritage stems from a 2U cubesat fluorescence microscope, the Fluorescence Analysis for In situ Research imager, designed and built at NASA Ames Research Center, for the autonomous study of microbial biology in low Earth orbit. For ELM implementation, a sample is autonomously manipulated with a microfluidic system using in-line 10, 1.0, and 0.2 μm pore-size filters to capture successively smaller particles for imaging. For bright-field imaging, ELM uses deep-ultraviolet, ultraviolet and visible light to image organic and inorganic structures with submicron resolution. The ability to detect biosignatures as small as 0.2 μm in size is achieved by imaging native fluorescence and using fluorescence microscopy stains to identify key structural and functional indicators of microbial life (proteins, lipids, nucleic acids). For fluorescence imaging, ELM uses 265, 370, 470, and 530 nm LEDs with five emission bands. The use of multiple excitation and emission wavelengths for native fluorescence imaging enables the detection of a wide range of molecular species and their rough classification. Excitation at 265 nm allows for the detection of smaller polycyclic aromatic hydrocarbons (PAH), aromatic amino acids, and proteins with little to no interference from mineral fluorescence, given proper emission band selection. 370 and 470 nm light excites increasingly larger PAH structures and larger aromatic biomolecules that may be present (e.g., protective pigments). Similarly, inorganic fluorescence can be characterized and separated from organic fluorescence, allowing the recognition and in some cases classification, of minerals and other abiotic particles. ELM is based upon work supported by the NASA COLDTech and ICEE-2 programs.

Richard C Quinn↗

Europa Luminescence Microscope

The Europa Luminescence Microscope (ELM) is an automated fluorescence and dark-field mi-croscope designed to meet key objectives defined in the NASA Europa Lander Study Report, includ-ing the identification and characterization of morphological biosignatures. ELM’s heritage stems from a 2U cubesat fluorescence microscope, the Fluorescence Analysis for In-situ Research (FLAIR) im-ager, designed and built at NASA Ames Research Center, for the autonomous study of microbial bi-ology in low Earth orbit. For the ELM implementation, a sample is autonomously manipulated with a microfluidic system using in-line filter sets to capture successively smaller particles on 10, 1.0, and 0.1 µm pore-size filters for imaging. For darkfield imaging, ELM uses ultraviolet and visible light to image organic and inorganic structures with submicron resolution. The ability to detect structural and chemical biosignatures as small as 0.2 µm in size is achieved by imaging native fluorescence and us-ing fluorescence microscopy stains to identify key molecular and structural indicators of microbial life (proteins, lipids, nucleic acids). To excite fluorescence, ELM uses LEDs with wavelengths centered near 265, 370, 470, and 530 nm and five emission bands. The use of multiple excitation and emission wavelengths for native fluorescence imaging not only enables the detection of different molecular species, but also their rough classification. Excitation at 265 nm allows for the detection of smaller polyaromatic hydrocarbons (PAHs; 1-5 rings), aromatic amino acids, and proteins with little to no interference from mineral fluorescence, given proper emission band selection. 370 and 470 nm light excites increasingly larger PAH structures (e.g., coronene) and larger aromatic biomolecules that may be present (e.g., protective pigments). Similarly, inorganic fluorescence can be characterized and sep-arated from organic fluorescence, allowing the recognition and in some cases classification, of miner-als and other abiotic particles. ELM is based upon work supported by the NASA COLDTech and ICEE-2 programs.

Microscope↗

Fluorescence from photoexcitation of Cl2 at 50 to 105 nm

The photoabsorption and fluorescence cross sections of Cl2 were measured in the 50 to 105 nm region. Excitation of Cl2 in the 90 to 109 nm region emits two UV bands with peaks at 258 and 307 nm. The emission bands are attributed to the Cl2(D' to A') transition that is produced by the energy transfer from Cl*(4P 5/2) to Cl2. The Cl2(+)(A to X) emission band is produced at the excitation wavelengths shorter than 89 nm.

Ma, Guang↗