Search NASA⌕ Search

SEARCH · Search NASA

Results for “Battery sizing optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Effect of Calcination Temperature on the Electrochemical Properties of Nickel-rich LiNi0.76Mn0.14Co0.10O2 Cathodes for Lithium-ion Batteries

High energy density nickel (Ni)-rich layered LiNixMnyCozO2 (NMC, x = 0.6) materials are promising cathodes for lithium-ion batteries. However, several technical challenges, such as fast capacity fading, are hampering their large scale application. Herein, we demonstrate that a Ni-rich cathode LiNi0.76Mn0.14Co0.10O2 (NMC76) calcined at an optimal temperature of 750~775oC exhibits a high discharge capacity (~215 mAh g-1 when charged to 4.5 V) and an excellent high rate capability. Even at a 10C rate, it still exhibits a capacity of more than 160 mAh g-1 and retains ca. 79% of its initial capacity after 200 cycles. The high performance of NMC76 is directly related to its optimized primary particle size (that constitute the spherical secondary particles of >10 m) and cation mixing. Higher calcination temperature (= 800 oC) leads to rapid increase of primary particle size, poor cycling stability, and inferior rate capability of NMC76 due to its severe micro strain and crack formation upon repeated lithium ion de/intercalations. Therefore, NMC76 calcined at 750~775oC is a very good candidate for the next generation of Li ion batteries.

nickel-rich cathodes, calcination temperature, cyc↗

Grace DAKASEP alkaline battery separator

The Grace DAKASEP separator was originally developed as a wicking layer for nickel-zinc alkaline batteries. The DAKASEP is a filled non-woven separator which is flexible and heat sealable. Through modification of formulation and processing variables, products with a variety of properties can be produced. Variations of DAKASEP were tested in Ni-H2, Ni-Zn, Ni-Cd, and primary alkaline batteries with good results. The properties of DAKASEP which are optimized for Hg-Zn primary batteries are shown in tabular form. This separator has high tensile strength, 12 micron average pore size, relatively low porosity at 46-48 percent, and consequently moderately high resistivity. Versions were produced with greater than 70 percent porosity and resistivities in 33 wt percent KOH as low as 3 ohm cm. Performance data for Hg-Zn E-1 size cells containing DAKASEP with the properties shown in tabular form, are more reproducible than data obtained with a competitive polypropylene non-woven separator. In addition, utilization of active material is in general considerably improved.

Giovannoni, R. T.↗

An analytical method for identifying synergies between behind-the-meter battery and thermal energy storage

Electric utilities build generation capacity to meet the highest demand period, and they often pass on the costs associated with these peaking generators to building owners through demand charges. Building owners can minimize these demand charges by shifting energy use away from peak periods with behind-the-meter storage. This storage can include batteries, which can directly shift the metered load, or thermal energy storage, which can shift thermal-driven electric loads like air conditioning. However, there is a lack of research on how best to combine battery and thermal energy storage. In this study, we develop an analytical sizing method to calculate the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. We show that adding batteries to a thermal energy storage system can increase the total system's load shaving potential. This is particularly true when the building has onsite photovoltaic generation or electric vehicle charging, which add significant variability to the load shape. We also show that for a given total storage size, selecting a higher fraction of thermal energy storage can significantly lower the cycling of the battery, and therefore extend the battery life. This, combined with the expected lower first cost of thermal energy storage materials compared to batteries, shows that hybrid energy storage systems can outperform a standalone battery or standalone thermal storage system. Assuming the thermal storage has a capital cost 6x lower than the battery, our analysis shows that the optimal system is 71% thermal energy storage and 29% battery energy storage for a scenario with electric vehicle charging. The annualized cost savings for this system are $48.6 k/yr, whereas an equivalently sized standalone thermal energy storage system would provide annualized cost savings of $28.5 k/yr and a standalone battery would lead to savings of $8.72 k/yr. The hybrid system also reduces battery cycling by 52% compared to a standalone battery, extending battery lifetime.

25 ENERGY STORAGE↗

Cost Effectiveness Analysis of Quasi-Static Wireless Power Transfer for Plug-In Hybrid Electric Transit Buses: Preprint

This study evaluates the costs and benefits associated with the use of a plug-in hybrid electric bus and determines the cost effectiveness relative to a conventional bus and a hybrid electric bus. A sensitivity sweep analysis was performed over a number of a different battery sizes, charging powers, and charging stations. The net present value was calculated for each vehicle design and provided the basis for the design evaluation. In all cases, given present day economic assumptions, the conventional bus achieved the lowest net present value while the optimal plug-in hybrid electric bus scenario reached lower lifetime costs than the hybrid electric bus. The study also performed parameter sensitivity analysis under low market potential assumptions and high market potential assumptions. The net present value of plug-in hybrid electric bus is close to that of conventional bus.

33 ADVANCED PROPULSION SYSTEMS↗

MiGRIDS

MiGRIDS is a software that models islanded microgrid power systems with different controls and components. For example, using load and resource data from a microgrid, you could model it with additional wind turbines, battery etc. You could also try out different dispatch schemes to see which one worked best. MiGRIDS is designed to help optimize the size and dispatch of grid components in a microgrid. While a grid connect feature is expected to be added in the future, islanded operation is the focus. Note that this is a basic implementation and more features and functionality (such as a GUI) are coming! MiGRIDS runs time-step energy balance simulations for different grid components and controls. In smaller microgrid environments, dispatch decisions are being made on the order of seconds. In order to fully capture their effect, this tool lets you run simulations on the order of seconds. The end result is a more realistic representation of what can be achieved by integrating different components and control strategies in a grid.

Morgan, Tawna↗

Keep it short: Exploring the impacts of configuration choices on the recent economics of solar-plus-battery and wind-plus-battery hybrid energy plants

Coupled renewable-battery powerplants differ from the traditional concept of independent siting of electricity resources within transmission networks. Prior research on the value proposition and cost savings from coupling did not consider the geographic constraint of co-location. This paper fills the gap by assessing how pricing volatility differences between nodes within electricity markets impact the system value of coupled renewable-battery projects as compared to independent VRE and battery installations. We use wholesale power market prices from 2012–2019 across the seven main U.S. independent system operators (ISOs) with a linear optimization program to compare the electricity market value of coupled projects to the value of the same underlying sub-components, deployed separately. We find that additional value from adding a 4-hour battery sized to 50% of renewable-plant nameplate capacity is $\$10$/MWh across ISOs on average. The highest boost occurs in California ($\$15$/MWh), where the value of adding storage to solar rises over time in tandem with increased solar penetration in the region. If renewables and batteries are deployed independently, we estimate that $\$12.5$/MWh of additional value could be achieved because of more flexibility on battery siting and operation. The $\$12.5$/MWh coupling penalty is reduced to $\$1.6$/MWh when considering alternative approaches to integrating battery storage. This result implies that renewable-battery power plants will play an increasing role in electricity systems if they can be built for $\$2$–$\$13$/MWh less than independent projects of comparable size. However, the wide regional variation in coupling penalties, along with the importance of conditions captured in our sensitivity cases, suggests the tradeoff between coupling penalties and savings will vary by situation. Therefore, roles exist for independent and coupled projects from a system optimization perspective.

14 SOLAR ENERGY↗

Co-optimized trading of hybrid wind power plant with retired EV batteries in energy and reserve markets under uncertainties

To be competitive in the electricity markets, various technologies have been reported to increase profits of wind farm owners. Combining battery storage system, wind farms can be operated as conventional power plants which promotes the integration of wind power into the power grid. However, high expenses on batteries keep investors away. Retired EV batteries, fortunately, still have enough capacity to be reused and could be obtained at a low price. In this work, a two-stage optimization of a wind energy retired EV battery-storage system is proposed. The economic performance of the proposed system is examined concerning its participation in the frequency containment normal operation reserve (FCR-N) market and the spot market simultaneously. To account uncertainties in the wind farm output, various electricity market prices, and up/down regulation status, a scenario-based stochastic programming method is used. The sizing of the equipment is optimized on top of daily operations of the hybrid system which formulates a mixed-integer linear programming (MILP) problem. Scenarios are generated with the Monte Carlo simulation (MCS) and Roulette Wheel Mechanism (RWM), which are further reduced with the simultaneous backward method (SBM) to increase computational efficiency. A 21 MW wind farm is selected as a case study. Here, the optimization results show that by integrating with a retired EV battery-storage system (RESS) and a bi-directional inverter, the wind farm can increase its profits significantly when forwarding bids in both of the aforementioned electricity markets.

17 WIND ENERGY↗

Drive Cycles, Battery Pack Scaling, and Usage Considerations for Long-Haul and Regional-Haul Electric Trucks

Electrifying Class-8 heavy-duty trucks presents a promising opportunity to enhance energy efficiency and reduce freight transport costs. Battery electric trucks (BETs), once considered niche, are gaining traction due to advancements in battery technology and cost reductions. However, accurately predicting battery lifespan under realistic usage conditions remains a key challenge. Understanding battery failure mechanisms and their links to design, operation, and management is essential for developers and fleet operators. This study introduces a method to develop simplified, lab-testable dynamic stress test (DST) cycles for regional and long-haul Class-8 BETs, derived from real-world diesel truck usage. These DSTs enable benchmarking of battery technologies, identification of aging stressors, and optimization of battery design, life, and cost. The approach supports evaluation of key metrics such as levelized cost of driving and total cost of ownership, aiding fair comparisons and adoption decisions. We also propose feasible battery pack sizes that meet current driving demands with strategic charging, and a method to scale pack-level DSTs to cell-level cycles for lab-based testing. These tools facilitate tradeoff analysis across battery chemistries, pack sizing, and charging strategies, while offering means to get insights into battery aging under realistic conditions-ultimately supporting informed BET deployment decisions.

25 ENERGY STORAGE↗

MINER - A Mobile Imager of Neutrons for Emergency Responders

We have developed a mobile fast neutron imaging platform to enhance the capabilities of emergency responders in the localization and characterization of special nuclear material. This mobile imager of neutrons for emergency responders (MINER) is based on the Neutron Scatter Camera, a large segmented imaging system that was optimized for large-area search applications. Due to the reduced size and power requirements of a man-portable system, MINER has been engineered to fit a much smaller form factor, and to be operated from either a battery or AC power. We chose a design that enabled omnidirectional (4π) imaging, with only a ~twofold decrease in sensitivity compared to the much larger neutron scatter cameras. The system was designed to optimize its performance for neutron imaging and spectroscopy, but it does also function as a Compton camera for gamma imaging. This document outlines the project activities, broadly characterized as system development, laboratory measurements, and deployments, and presents sample results in these areas. Additional information can be found in the documents that reside in WebPMIS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Battery Evaluation Profiles for X-57 and Future Urban Electric Aircraft

Battery energy density is one of the most critical design parameters for sizing all-electric aircraft, however it’s easily overestimated. Establishing the effective, usable energy density is confused by varying degrees of margin needed to account for structural and thermal management between different cell chemistry and pack designs. Therefore, a better methodology is needed to fairly compare emerging battery technologies for electric aircraft. Currently, there is a loss of critical information when vehicle trade studies are performed using “nominal” published cell-level performance metrics. Aircraft power demands rarely match these nominal power profiles, and aircraft designers lack the ability to accurately simulate the battery performance and temperature off-nominally unless the battery chemistry is well established. Conversely, battery suppliers have no generalized reference cases to publish more realistic performance metrics. This can lead to poor assumptions, such as aircraft studies assuming a fixed discharge efficiency of a battery, when in reality the usable energy in a pack is dependent on the power and thermal profile. Information needed to properly assess weight penalties for thermal management is also typically poorly characterized when assessing candidate batteries. This paper serves to better inform battery development, and similarly, provide aircraft designers with more realistic assumptions for applying knockdown margins in their designs. Detailed power and thermal performance estimates are provided, which provide a starting point for sizing power and thermal budgets using experimentally derived battery models. Results show that the X-57 battery-to-shaft efficiency is 77.3% for a particular optimized mission. Considering a 25% reserve on the battery capacity, this means that only roughly half of the original 55.3kWh ‘nominal’ pack energy can be converted to useful work during a mission. Further estimates on a clean-sheet VTOL optimization show an average 82.7% battery-to-shaft efficiency, using 98% peak efficiency inverters and 97.4% peak efficiency motors. Although higher battery efficiencies are possible, the resulting weight penalty negates improvement in vehicle performance. These trade-offs and resulting power profiles are provided as a starting point to better assess future battery designs.

Battery Electric Aircraft↗

Battery Evaluation Profiles for X-57 and Future Urban Electric Aircraft

Battery energy density is one of the most critical design parameters for sizing all-electric aircraft, however it’s easily overestimated. Establishing the effective, usable energy density is confused by varying degrees of margin needed to account for structural and thermal management between different cell chemistry and pack designs. Therefore, a better methodology is needed to fairly compare emerging battery technologies for electric aircraft. Currently, there is a loss of critical information when vehicle trade studies are performed using “nominal” published cell-level performance metrics. Aircraft power demands rarely match these nominal power profiles, and aircraft designers lack the ability to accurately simulate the battery performance and temperature off-nominally unless the battery chemistry is well established. Conversely, battery suppliers have no generalized reference cases to publish more realistic performance metrics. This can lead to poor assumptions, such as aircraft studies assuming a fixed discharge efficiency of a battery, when in reality the usable energy in a pack is dependent on the power and thermal profile. Information needed to properly assess weight penalties for thermal management is also typically poorly characterized when assessing candidate batteries. This paper serves to better inform battery development, and similarly, provide aircraft designers with more realistic assumptions for applying knockdown margins in their designs. Detailed power and thermal performance estimates are provided, which provide a starting point for sizing power and thermal budgets using experimentally derived battery models. Results show that the X-57 battery-to-shaft efficiency is 77.3% for a particular optimized mission. Considering a 25% reserve on the battery capacity, this means that only roughly half of the original 55.3kWh ‘nominal’ pack energy can be converted to useful work during a mission. Further estimates on a clean-sheet VTOL optimization show an average 82.7% battery-to-shaft efficiency, using 98% peak efficiency inverters and 97.4% peak efficiency motors. Although higher battery efficiencies are possible, the resulting weight penalty negates improvement in vehicle performance. These trade-offs and resulting power profiles are provided as a starting point to better assess future battery designs.

Battery↗

Advanced Wireless Power Transfer Vehicle and Infrastructure Analysis (Presentation)

This presentation discusses current research at NREL on advanced wireless power transfer vehicle and infrastructure analysis. The potential benefits of E-roadway include more electrified driving miles from battery electric vehicles, plug-in hybrid electric vehicles, or even properly equipped hybrid electric vehicles (i.e., more electrified miles could be obtained from a given battery size, or electrified driving miles could be maintained while using smaller and less expensive batteries, thereby increasing cost competitiveness and potential market penetration). The system optimization aspect is key given the potential impact of this technology on the vehicles, the power grid and the road infrastructure.

2014 AMR↗

Improving Computational Efficiency of Prognostics Algorithms in Resource-Constrained Settings

The field of prognostics and health management provides quantitative methods for monitoring and predicting the health of physical systems. Prognostics algorithms are useful in that they can be employed to assess the current state of a system, propagate the system state throughout time, and predict potential anomalies or failures that may occur. However, effective prognosis can be challenging to achieve in resource-constrained settings due to computational limitations and high computational latency, leading to obsolete predictions. Thus, computationally efficient and accurate algorithms are necessary for some prognostics applications. In this work, we implement three new algorithmic approaches to prediction (sampling methods, variable prediction time step, variable prediction sample size) with the goal of improving computational efficiency while minimizing decrease in model accuracy. To quantitatively analyze our results, we examine a use-case of degradation of a Lithium-ion battery. Notably, through this work it was found that none of the sampling approaches had a significant impact on computational efficiency or model accuracy in predicting EOD of the battery. However, our results show that prediction accuracy is highly dependent on the time step used, and that an appropriate time step can optimize both model accuracy and simulation efficiency. Finally, implementing a variable sample size also affected prediction, and our results show that tuning both the magnitude and timing of the sample size adjustment in an application-specific manner may prove useful in some applications. Taken together, our findings highlight the challenge of performing prognostics in resource-constrained settings, and illustrate the potential of developing new prediction algorithms to improve computational efficiency of prognosis.

Prognostics↗

Multidisciplinary Optimization of A Transonic Truss-Braced Wing Aircraft Using Aviary

The continuous push to decrease fuel burn of single-aisle commercial aircraft has led to interest in a Transonic Truss-Braced Wing (TTBW) concept vehicle. Sporting high-slung wings that are long and slender to increase aerodynamic efficiency, a TTBW can also accommodate higher-bypass turbine engines. The combination of these two changes potentially leads to an overall decrease in fuel consumption. In this paper, a TTBW concept vehicle is assembled in the Aviary open-source tool for conceptual aircraft design. The conceptual-level aerodynamics and propulsion systems that come prepackaged with Aviary are replaced with higher-fidelity vortex lattice method for aerodynamics (VSPAERO) and a one-dimensional cycle analysis tool for propulsion (pyCycle). The vehicle is then optimized to minimize fuel burn for a representative commercial mission. Design parameters for the vehicle include the electrified turbine size, the size of the electric motors which are used for takeoff and climb assist, and battery capacity. The TTBW concept vehicle presented in this paper represents the first application of Aviary to an aircraft design problem.

Optimization↗

Addressing the split incentive challenge for rooftop solar PV and battery energy storage in multifamily rental buildings (CRADA 638 Final Report)

This project advances the understanding of how roof solar PV systems and battery energy storage systems (BESS) can be effectively deployed in multifamily residential buildings, a sector that has historically faced barriers due to misaligned incentives between landlords and tenants. By leveraging high-resolution building stock data and simulation tools, the research demonstrates how energy consumption patterns vary across building types, climates, and occupant characteristics, and how these variations influence the optimal sizing and operation of distributed energy resources. A key contribution is the development of a publicly accessible, web-based tool named RESIDE (Residential Energy Systems & Infrastructure Data Evaluation) that allows users to explore building energy use and evaluate solar and battery configurations without requiring specialized expertise. This significantly lowers the barrier to entry for stakeholders such as property owners, utilities, and policymakers. From a technical perspective, the project shows that integrating rooftop solar PV with battery energy storage can substantially reduce electricity costs and peak demand through strategies such as energy arbitrage and peak shaving. The modeling framework incorporates real-world constraints, including time-of-use electricity pricing and battery degradation, providing realistic and actionable insights. Economically, the results indicate that properly sized systems can deliver meaningful cost savings, improving the feasibility of energy investments in multifamily housing. More broadly, the project benefits the public by supporting the transition to affordable and reliable energy, particularly in rental multifamily housing where adoption has traditionally lagged.

14 SOLAR ENERGY↗

Lithium-Ion Batteries for Aerospace Applications

This presentation reviews: (1) the goals and objectives, (2) the NASA and Airforce requirements, (3) the potential near term missions, (4) management approach, (5) the technical approach and (6) the program road map. The objectives of the program include: (1) develop high specific energy and long life lithium ion cells and smart batteries for aerospace and defense applications, (2) establish domestic production sources, and to demonstrate technological readiness for various missions. The management approach is to encourage the teaming of universities, R&D organizations, and battery manufacturing companies, to build on existing commercial and government technology, and to develop two sources for manufacturing cells and batteries. The technological approach includes: (1) develop advanced electrode materials and electrolytes to achieve improved low temperature performance and long cycle life, (2) optimize cell design to improve specific energy, cycle life and safety, (3) establish manufacturing processes to ensure predictable performance, (4) establish manufacturing processes to ensure predictable performance, (5) develop aerospace lithium ion cells in various AH sizes and voltages, (6) develop electronics for smart battery management, (7) develop a performance database required for various applications, and (8) demonstrate technology readiness for the various missions. Charts which review the requirements for the Li-ion battery development program are presented.

Surampudi, S.↗

Techno-economic analysis of the impact of dynamic electricity prices on solar penetration in a smart grid environment with distributed energy storage

This study investigates the technical and economic feasibility of using high levels of solar energy penetration up to 400 MW into a smart grid system of 60,000 smart houses. A novel non-cooperative Stackelberg game is introduced that incorporates the profitability of the supply-side and helps in solving problems related to overgeneration and photovoltaic curtailment. The non-cooperative game is intended to find the optimal dynamic prices that would leverage distributed storage through the demand-side to stabilize the power grid operation. Ten cases are studied with five photovoltaic plant sizes and two battery designs. Here, a novel quantitative analysis of high levels of solar penetration as a percentage of the total electricity demand is introduced to evaluate the technical feasibility of the studied cases. To evaluate the economic viability of the proposed smart grid system, four metrics were used: the levelized cost of energy, the levelized cost of storage, the payback period, and the net present value. Two out of ten studied cases were concluded to be the most promising cases, one with a solar photovoltaic plant size of 200 MW and the other with 300 MW. The case with 300 MW solar plant is preferred as it paves the way for more solar energy deployment with a solar penetration percentage up to 67.78%. This case had a payback period of 10.72 years and a net present value of $\$51.44$ M for the solar plant and a payback period of 12.06 years and a net present value of $\$40.75$ M for the demand-side.

14 SOLAR ENERGY↗

Optimizing Discharge Capacity of Li-O 2 Batteries by Design of Air-Electrode Porous Structure: Multifidelity Modeling and Optimization

We develop a new mathematical framework to study the optimal design of air electrode microstructures for lithium-oxygen (Li-O2) batteries. It can eectively reduce the number of expensive experiments for testing dierent air-electrodes, thereby minimizing the cost in the design of Li-O2 batteries. The design parameters to characterize an air-electrode microstructure include the porosity, surface-to-volume ratio, and parameters associated with the pore-size distribution. A surrogate model (also known as response surface) for discharge capacity is rst constructed as a function of these design parameters. The surrogate model is accurate and easy to evaluate such that an optimization can be performed based on it. In particular, a Gaussian process regression method, co-kriging, is employed due to its accuracy and eciency in predicting high-dimensional responses from a combination of multidelity data. Specically, a small amount of data from high-delity simulations are combined with a large number of data obtained from computationally ecient low-delity simulations. The high-delity simulation is based on a multiscale modeling approach that couples the microscale (pore-scale) and macroscale (device-scale) models. Whereas, the low-delity simulation is based on an empirical macroscale model. The constructed response surface provides quantitative understanding and prediction about how air electrode microstructures aect the discharge performance of Li-O2 batteries. The succeeding sensitivity analysis via Sobol indices and optimization via genetic algorithm ultimately oer a reliable guidance on the optimal design of air electrode microstructures. The proposed mathematical framework can be generalized to investigate other new energy storage techniques and materials.

25 ENERGY STORAGE↗