SEARCH · Search NASA
Results for “Bayesian model calibration”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Wildland fire mid-story: A generative modeling approach for representative fuels
Not Available
Practical Use of Computationally Frugal Model Analysis Methods
Computationally frugal methods of model analysis can provide substantial benefits when developing models of groundwater and other environmental systems. Model analysis includes ways to evaluate model adequacy and to perform sensitivity and uncertainty analysis. Frugal methods typically require 10s of parallelizable model runs; their convenience allows for other uses of the computational effort. We suggest that model analysis be posed as a set of questions used to organize methods that range from frugal to expensive (requiring 10,000 model runs or more). This encourages focus on method utility, even when methods have starkly different theoretical backgrounds. We note that many frugal methods are more useful when unrealistic process-model nonlinearities are reduced. Inexpensive diagnostics are identified for determining when frugal methods are advantageous. Examples from the literature are used to demonstrate local methods and the diagnostics. We suggest that the greater use of computationally frugal model analysis methods would allow questions such as those posed in this work to be addressed more routinely, allowing the environmental sciences community to obtain greater scientific insight from the many ongoing and future modeling efforts
Bayesian Calibration of Stochastic Agent Based Model via PCA Based Surrogate Modeling
Explore the source record for details and available documents.
Bayesian calibration of the Community Land Model using surrogates .
Abstract Not Provided
Bayesian calibration of a ??e turbulence model for predictive jet-in-crossflow simulations.
Abstract not provided.
BAYESIAN CALIBRATION OF THE COMMUNITY LAND MODEL USING SURROGATES.
Abstract not provided.
Bayesian calibration of engineering and scientific models using surrogates.
Abstract not provided.
Large-scale Deterministic Inversion and Bayesian Calibration in Land-Ice Modeling.
Abstract not provided.
Bayesian calibration of the Community Land Model using a multi-chain Markov chain Monte Carlo method.
Abstract not provided.
Bayesian calibration of a hybrid nuclear collision model using $\textit{p}$₋Pb and Pb-Pb data at energies available at the CERN Large Hadron Collider
Here, we posit a unified hydrodynamic and microscopic description of the quark-gluon plasma (QGP) produced in ultrarelativistic p₋Pb and Pb-Pb collisions at $\sqrt{s}_\text{NN}$ = 5.02 TeV and evaluate our assertion using Bayesian inference. Specifically, we model the dynamics of both collision systems using initial conditions with parametric nucleon substructure, a preequilibrium free streaming stage, event-by-event viscous hydrodynamics, and a microscopic hadronic afterburner. Free parameters of the model, which describe the initial state and QGP medium are then simultaneously calibrated to fit charged-particle yields, mean $p_T$, and flow cumulants. We argue that the global agreement of the calibrated model with the experimental data strongly supports the existence of hydrodynamic flow in small collision systems at ultrarelativistic energies, and that the flow produced develops at length scales smaller than a single proton. Posterior estimates for the model's input parameters are obtained, and new insights into the temperature dependence of the QGP transport coefficients and event-by-event structure of the proton are discussed.
Bayesian Optimal Experimental Design for Material Model Calibration
Explore the source record for details and available documents.
Bayesian Optimal Experimental Design for Constitutive Model Calibration Using Full-Field DIC Data
Explore the source record for details and available documents.
Uncertainty Quantification and Bayesian Calibration of a Powder-Scale Model for Selective Laser Melting.
Abstract not provided.
Bayesian Inference and the Effects of Varying Uncertainty Models in Charring Ablator Calibration and Uncertainty Quantification Problems
The Mars Science Laboratory (MSL) vehicle utilized a heat shield constructed from NASA’s Phenolic-Impregnated Carbon Ablator (PICA) material to protect the main structure from the high enthalpy environment encountered during hypersonic atmospheric entry. During the vehicle’s descent through Martian atmosphere, multiple thermocouples embedded within the heat shield captured in-depth material temperature data that allow for studies to be conducted on current material response reconstruction tools. In the present work, material temperature data obtained from thermocouples within the MISP-4 plug (MEDLI (Mars Science Laboratory Entry, Descent, and Landing Instrument) Integrated Sensor Plug) are utilized in the calibration of Theoretical Ablative Composite for Open Testing (TACOT) model parameters in conjunction with NASA’s Porous material Analysis Toolbox (PATO) through Bayesian inference where uncertainty due to parametric, modeling, and experimental sources is simultaneously quantified. Prior to the study, a sensitivity analysis is performed through computation of the robust Sobol indices in an effort to study the relationship between input space and model response and to reduce the dimensionality of the statistical inverse problem. The Bayesian inference methodology necessitates an a-priori choice to be made for the uncertainty model for which numerous possibilities are available. Across most works, however, only basic additive or multiplicative models are utilized with pre-defined magnitudes of uncertainty based on a-priori knowledge or to-be-calibrated multipliers of static covariance matrix structures. The present effort explores the effects of informed uncertainty models, ones with temporal dependence that are simultaneously calibrated through Bayesian inference, on calibrated results for parameters that make up the uncertain input space.
Bayesian calibration of a physics-based crystal plasticity and damage model
In this work, we present a model parameter calibration procedure for a physics-based crystal plasticity model. The calibration process utilizes a powerful statistics-based Bayesian calibration method. Calibration of the crystal plasticity parameters makes use of experimentally-measured data, i.e. compressive stress–strain response, from $\langle$100$\rangle$ and $\langle$123$\rangle$ single crystal copper dynamically loaded via Kolsky bar tests. The calibration of damage parameters is achieved using experimentally-measured free-surface velocity history data from plate impact test on $\langle$100$\rangle$ and $\langle$110$\rangle$ single crystal copper, which generates shock compression followed by dynamic tensile failure. A validation assessment is then carried out by comparing the calibrated model predictions and experimental measurements of the dynamic tensile damage generated in an impacted bicrystal copper plate. Lastly, a model-informed rationale for the experimentally-observed dependence of the spatial distribution of ductile damage (porosity) on crystallography is provided.
Bayesian calibration of thermodynamic parameters for geochemical speciation modeling of cementitious materials
Chemical equilibrium modeling of cementitious materials requires aqueous-solid equilibrium constants of the controlling mineral phases (K{sub sp}) and the available concentrations of primary components. Inherent randomness of the input and model parameters, experimental measurement error, the assumptions and approximations required for numerical simulation, and inadequate knowledge of the chemical process contribute to uncertainty in model prediction. A numerical simulation framework is developed in this paper to assess uncertainty in K{sub sp} values used in geochemical speciation models. A Bayesian statistical method is used in combination with an efficient, adaptive Metropolis sampling technique to develop probability density functions for K{sub sp} values. One set of leaching experimental observations is used for calibration and another set is used for comparison to evaluate the applicability of the approach. The estimated probability distributions of K{sub sp} values can be used in Monte Carlo simulation to assess uncertainty in the behavior of aqueous-solid partitioning of constituents in cement-based materials.