Effect of a hypergravity environment on cortical bone elasticity in rats

There is considerable interest in determining whether hypergravity can be used as a countermeasure for microgravity-induced bone loss. This study was conducted on 20 immature male rats in order to investigate possible elastic adaptations of cortical bone in rapidly growing rats exposed to chronic hypergravity. Ten rats were continuously centrifuged for 14 days at twice gravitational acceleration (2G) on a 12.75 foot radius centrifuge and 10 rats concurrently acted as stationary controls. The effect of hypergravity on the elastic characteristics of cortical bone was quantified via ultrasonic wave propagation. Propagation velocities of longitudinal and shear waves were measured through cubic cortical specimens from the posterior femoral diaphyses. Density was measured with an Archimedes' technique. The orthotropic elastic properties were calculated and used to compare the difference between groups. Results showed an average increase in both the Young's moduli (Eii, + 2.2%) and shear moduli (Gij, + 4.3%) with a statistically significant increase only in G12 (+15.7%, P = 0.046). The ratio of transverse to axial strain (Poisson's ratio, nuij) demonstrated statistically significant changes in nu12, nu21, nu13, and nu31 (P < 0.05). These findings suggest that although slight elastic changes were incurred via a hypergravity environment, the treatment level or duration in this study do not dramatically perturb the normal elastic behavior of cortical bone and that dramatic biomechanical differences noted in previous studies were due more to structural changes than material elasticity changes. Hypergravity applied post facto to a microgravity environment would offer further illucidation of this method as treatment for a degenerative spaceflight experience.

Non-NASA Center↗

Microgravity-Induced Physiological Fluid Redistribution: Computational Analysis to Assess Influence of Physiological Parameters

Space flight impacts human physiology in many ways, the most immediate being the marked cephalad (headward) shift of fluid upon introduction into the microgravity environment. This physiological response to microgravity points to the redistribution of blood and interstitial fluid as a major factor in the loss of venous tone and reduction in heart muscle efficiency which impact astronaut performance. In addition, researchers have hypothesized that a reduction in astronaut visual acuity, part of the Visual Impairment and Intracranial Pressure (VIIP) syndrome, is associated with this redistribution of fluid. VIIP arises within several months of beginning space flight and includes a variety of ophthalmic changes including posterior globe flattening, distension of the optic nerve sheath, and kinking of the optic nerve. We utilize a suite of lumped parameter models to simulate microgravity-induced fluid redistribution in the cardiovascular, central nervous and ocular systems to provide initial and boundary data to a 3D finite element simulation of ocular biomechanics in VIIP. Specifically, the lumped parameter cardiovascular model acts as the primary means of establishing how microgravity, and the associated lack of hydrostatic gradient, impacts fluid redistribution. The cardiovascular model consists of 16 compartments, including three cerebrospinal fluid (CSF) compartments, three cranial blood compartments, and 10 thoracic and lower limb blood compartments. To assess the models capability to address variations in physiological parameters, we completed a formal uncertainty and sensitivity analysis that evaluated the relative importance of 42 input parameters required in the model on relative compartment flows and compartment pressures. Utilizing the model in a pulsatile flow configuration, the sensitivity analysis identified the ten parameters that most influenced each compartment pressure. Generally, each compartment responded appropriately to parameter variations associated with itself and adjacent compartments. However, several unexpected interactions between components, such as between the choroid plexus and the lower capillaries, were found, and are due to simplifications in the formulation of the model. The analysis illustrates that highly influential parameters and those that have unique influences within the model formulation must be tightly controlled for successful model application.

gravitational physiology↗

Influence of Population Variation of Physiological Parameters in Computational Models of Space Physiology

The earliest manifestations of Visual Impairment and Intracranial Pressure (VIIP) syndrome become evident after months of spaceflight and include a variety of ophthalmic changes, including posterior globe flattening and distension of the optic nerve sheath. Prevailing evidence links the occurrence of VIIP to the cephalic fluid shift induced by microgravity and the subsequent pressure changes around the optic nerve and eye. Deducing the etiology of VIIP is challenging due to the wide range of physiological parameters that may be influenced by spaceflight and are required to address a realistic spectrum of physiological responses. Here, we report on the application of an efficient approach to interrogating physiological parameter space through computational modeling. Specifically, we assess the influence of uncertainty in input parameters for two models of VIIP syndrome: a lumped-parameter model (LPM) of the cardiovascular and central nervous systems, and a finite-element model (FEM) of the posterior eye, optic nerve head (ONH) and optic nerve sheath. Methods: To investigate the parameter space in each model, we employed Latin hypercube sampling partial rank correlation coefficient (LHSPRCC) strategies. LHS techniques outperform Monte Carlo approaches by enforcing efficient sampling across the entire range of all parameters. The PRCC method estimates the sensitivity of model outputs to these parameters while adjusting for the linear effects of all other inputs. The LPM analysis addressed uncertainties in 42 physiological parameters, such as initial compartmental volume and nominal compartment percentage of total cardiac output in the supine state, while the FEM evaluated the effects on biomechanical strain from uncertainties in 23 material and pressure parameters for the ocular anatomy. Results and Conclusion: The LPM analysis identified several key factors including high sensitivity to the initial fluid distribution. The FEM study found that intraocular pressure and intracranial pressure had dominant impact on the peak strains in the ONH and retro-laminar optic nerve, respectively; optic nerve and lamina cribrosa stiffness were also important. This investigation illustrates the ability of LHSPRCC to identify the most influential physiological parameters, which must therefore be well-characterized to produce the most accurate numerical results.

biomechanics↗

Modeling Microgravity Induced Fluid Redistribution Autoregulatory and Hydrostatic Enhancements

Space flight induces a marked cephalad (headward) redistribution of blood and interstitial fluid potentially resulting in a loss of venous tone and reduction in heart muscle efficiency upon introduction into the microgravity environment. Using various types of computational models, we are investigating how this fluid redistribution may induce intracranial pressure changes, relevant to reported reductions in astronaut visual acuity, part of the Visual Impairment and Intracranial Pressure (VIIP) syndrome. Methods: We utilize a lumped parameter cardiovascular system (CVS) model, augmented by compartments comprising the cerebral spinal fluid (CSF) space, as the primary tool to describe how microgravity, and the associated lack of hydrostatic gradient, impacts fluid redistribution. Models of ocular fluid pressures and biomechanics then accept the output of the above model as boundary condition input to allow more detailed, local analysis (see IWS Abstract by Ethier et al.). Recently, we enhanced the capabilities our previously reported CVS model through the implementation of robust autoregulatory mechanisms and a more fundamental approach to the implementation of hydrostatic mechanisms. Modifying the approach of Blanco et al., we implemented auto-regulation in a quasi-static manner, as an averaged effect across the span of one heartbeat. This approach reduced the higher frequency perturbations from the regulatory mechanism and was intended to allow longer simulation times (days) than models that implement within-beat regulatory mechanisms (minutes). A more fundamental approach to hydrostatics was implemented by a quasi-1D approach, in which compartment descriptions include compartment length, orientation and relative position, allowed for modeling of body orientation, relative body positioning and, in the future, alternative gravity environments. At this time the inclusion of hydrostatic mechanisms supplies additional capabilities to train and validate the CVS model with terrestrial data. Results and Conclusions: With the implementation of auto-regulation and hydrostatic modeling capabilities, the model performs as expected in the maintaining the CA (Central Artery) compartment pressure when simulating orientations ranging from supine to standing. The model appears to generally overpredict heart rate and thus cardiac output, possibly indicating sensitivity to the nominal heart rate, which is used as an initial set point of the regulation mechanisms. Despite this sensitivity, the model performs consistently for many hours of simulation time, indicating the success of our quasi-static implementation approach.

biomechanics↗

Estimation of Lower-Body Kinetics from Loading Profile and Kinematics Alone, Without Measured Ground Reaction Forces

Biomechanical models of human motion can estimate kinetic outcomes, such as joint moments, joint forces and muscle forces. Typically, one performs an inverse dynamics (ID) analysis to compute joint moments from joint angles and measured external forces. Sometimes it is impractical to measure ground reaction forces and moments (GRF&M). We devised an empirical method for performing ID analysis of resistance exercises without measured GRF&M. The method solves the multibody dynamics equations of motion with four key assumptions about the GRF&M that reduce the number of unknowns. The assumptions are 1) negligible ground reaction moments, 2) fixed lateral/medial location of the center of pressure (COP), 3) equal fore/aft location of the COP between the feet, and 4) constant angle of the GRF vector relative to the vertical axis in the frontal plane. We used evaluation trials from a spaceflight countermeasure resistance training device to test this approach. Four participants performed squat and deadlift exercises at various loads. We compared results from traditional ID analysis to results without measured GRF&M using our method. We found that joint moment trajectories in the sagittal plane were qualitatively similar in shape between the two methods, and the amount of root mean squared error (RMSE), measured by difference in joint moment impulse, was typically under 10 percent. Non-sagittal joint moment trajectories, which are much lower in overall magnitude, were not qualitatively similar in shape between the two methods. Non-sagittal moments displayed much higher RMSE, with typical values well over 50 percent. These findings were further supported by validation metrics (Sprague and Geers' P and M metrics, Pearson's r correlation coefficient). Based on these findings, we concluded that useful kinetic results are obtained from ID analysis of squat and deadlift exercises, even when GRF&M are not measured, as long as the outcomes of interest lie in the sagittal plane.

computational modeling↗

Study of Advanced Occupant Models to Quantify Injury Risk for eVTOL Vehicles

Urban transportation is currently evolving from traditional ground-based vehicles (cars, taxis, and buses) to include air-based electric vertical take-off and landing (eVTOL) vehicles which can be utilized for on-demand transportation, cargo transport, and emergency services. These new eVTOL vehicles are designed to be small, lightweight, and able to operate autonomously without user intervention. Safety is a big part of eventual eVTOL adoption, however gaps in the consideration of safety features exist. Anthropomorphic test devices (ATDs) are used in aerospace crashworthiness standards to quantify occupant injury risk and develop improved safety designs for emergency landing situations, but the ATDs currently used in aircraft certification requirements were developed many decades ago. Developments have occurred over the years involving ATD technology, which includes a host of newer and more biofidelic ATDs such as the Test Device for Human Occupant Restraint (THOR). Increased computing power has also allowed for detailed computational human body models (HBMs) to be created, such as the Global Human Body Model Consortium (GHBMC). This study aims to assess the capability of both HBMs and new ATD designs to identify injury mechanisms within eVTOL relevant emergency landing conditions. Finite element (FE) analysis was used to expand upon full-scale and seat level impact testing conducted by researchers at the National Aeronautics and Space Administration (NASA) to look at effects of occupant model configurations on prediction of injury. The GHBMC HBM and THOR ATD models were simulated in the seat level test conditions to characterize differences between these advanced assessment tools and traditional ATDs in the isolated seat loading environment. Results identified key differences in the responses from each of the models utilized and compared their impact response in head, neck, and spinal injury metrics. The THOR model identified potential risks for head injuries due to head impacts on the seat, however it predicted lower spinal loads than the other occupant surrogates. The GHBMC showed distinctly different biomechanical responses compared to the ATD. The GHBMC model is much more deformable than the ATDs and it exhibited higher distribution of forces and increased sensitivity to the duration of acceleration pulses. Both models incorporated into this study identified key mechanisms for injury that should be considered for passenger safety in the development of these novel aircraft. In addition, this study demonstrated the value of FE modeling for running a variety of complex human surrogates to identify potential injury mechanisms for consideration in regulation and development of new aircraft. Continued research in this field to improve validation these models will only lead to safer aircraft and more comprehensive safety measures.

Crashworthiness↗

Study of Advanced Occupant Models to Quantify Injury Risk for eVTOL Vehicles

Urban transportation is currently evolving from traditional ground-based vehicles (cars, taxis, and buses) to include air-based electric vertical take-off and landing (eVTOL) vehicles which can be utilized for on-demand transportation, cargo transport, and emergency services. These new eVTOL vehicles are designed to be small, lightweight, and able to operate autonomously without user intervention. Safety is a big part of eventual eVTOL adoption, however gaps in the consideration of safety features exist. Anthropomorphic test devices (ATDs) are used in aerospace crashworthiness standards to quantify occupant injury risk and develop improved safety designs for emergency landing situations, but the ATDs currently used in aircraft certification requirements were developed many decades ago. Developments have occurred over the years involving ATD technology, which includes a host of newer and more biofidelic ATDs such as the Test Device for Human Occupant Restraint (THOR). Increased computing power has also allowed for detailed computational human body models (HBMs) to be created, such as the Global Human Body Model Consortium (GHBMC). This study aims to assess the capability of both HBMs and new ATD designs to identify injury mechanisms within eVTOL relevant emergency landing conditions. Finite element (FE) analysis was used to expand upon full-scale and seat level impact testing conducted by researchers at the National Aeronautics and Space Administration (NASA) to look at effects of occupant model configurations on prediction of injury. The GHBMC HBM and THOR ATD models were simulated in the seat level test conditions to characterize differences between these advanced assessment tools and traditional ATDs in the isolated seat loading environment. Results identified key differences in the responses from each of the models utilized and compared their impact response in head, neck, and spinal injury metrics. The THOR model identified potential risks for head injuries due to head impacts on the seat, however it predicted lower spinal loads than the other occupant surrogates. The GHBMC showed distinctly different biomechanical responses compared to the ATD. The GHBMC model is much more deformable than the ATDs and it exhibited higher distribution of forces and increased sensitivity to the duration of acceleration pulses. Both models incorporated into this study identified key mechanisms for injury that should be considered for passenger safety in the development of these novel aircraft. In addition, this study demonstrated the value of FE modeling for running a variety of complex human surrogates to identify potential injury mechanisms for consideration in regulation and development of new aircraft. Continued research in this field to improve validation these models will only lead to safer aircraft and more comprehensive safety measures.

Crashworthiness↗

Finite Element Modeling of Extravehicular Mobility Units for Use With Human Body Models – Motivation, Major Challenges, Use Cases and Preliminary Work

Finite element modeling of pressurized spacesuits and implementation with human body models offers many advantages over physical experimentation, but also presents significant challenges. A model of pressurized spacesuit softgoods was developed, integrated with an existing hardgoods model, and fitted to a human body model. Two representative loading scenarios were simulated: dynamic external suit loading and internal occupant-driven loading, to serve as proof-of-concept for the modeling techniques employed. The modeled interactions behaved as intended and illustrate that finite element models of pressurized spacesuits can be used in conjunction with human body models to assess the biomechanical behavior. Further model development and experimental validation are needed.

Finite Element↗

Finite Element Modeling of Extravehicular Mobility Units for Use With Human Body Models – Motivation, Major Challenges, Use Cases and Preliminary Work

Finite element modeling of pressurized spacesuits and implementation with human body models offers many advantages over physical experimentation, but also presents significant challenges. A model of pressurized spacesuit softgoods was developed, integrated with an existing hardgoods model, and fitted to a human body model. Two representative loading scenarios were simulated: dynamic external suit loading and internal occupant-driven loading, to serve as proof-of-concept for the modeling techniques employed. The modeled interactions behaved as intended and illustrate that finite element models of pressurized spacesuits can be used in conjunction with human body models to assess the biomechanical behavior. Further model development and experimental validation are needed.

Finite Element↗

Vibration

Physiological and biomechanical responses of humans to vibrations during manned space flight and threshold data on tolerances to various vibrational modes and conditions

Chambers, A. N.↗

Aeroelasticity

Aeroelasticity problems, discussing unrestrained flexible structures design, nonconservative systems stability, biomechanics, etc

Ashley, H.↗

Human strength simulations for one and two-handed tasks in zero gravity

A description is given of a three dimensional hand force capability model for the seated operator and a biomechanical model for analysis of symmetric sagittal plane activities. The models are used to simulate and study human strengths for one and two handed tasks in zero gravity. Specific conditions considered include: (1) one hand active, (2) both hands active but with different force directions on each, (3) body bracing situations provided by portable foot restraint when standing and lap belt when seated, (4) static or slow movement tasks with maximum length of 4 seconds and a minimum rest of 5 minutes between exertions, and (5) wide range of hand positions relative to either the feet or bisection of a line connecting the hip centers. Simulations were also made for shirt sleeved individuals and for the male population strengths with anthropometry matching that of astronauts.

Source record↗

Solution of a system of dual integral equations.

The solution of a presented system of differential equations with initial values is shown to satisfy a system of dual integral equations of a type appearing in the study of axisymmetric problems of potential theory. Of practical interest are possible applications in biomechanics, particularly, for the case of trauma due to impact.

Buell, J.↗

Impact

Impact, emergency escape and crash survival protection are studied. Accleration, the G system of units, data interpretation, and human tolerance limits are summarized, along with physiological and biochemical response to impact. Biomechanical factors of impact are also cited.

Snyder, R. G.↗