Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Energy Codes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Residential Slab Component Calculations

Modern residential building energy codes provide a component tradeoff mechanism by which builders can trade reductions in the efficiency of some building components in trade for corresponding improvement in other components. One common tradeoff approach is based on maintaining a building "UA value," which represents the building envelope's overall thermal conductance. The building UA is the sum of individual component UA values, each of which is calculated as the product of the component's U-factor and area. Current codes, however, provide little guidance on including slab-on-grade components in the overall UA calculation. This brief provides information on calculating effective slab UA values and provides recommended text for building codes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Commercial Zero Code Plug-In: Zero Energy and Operational Emissions Overlay for Model Energy Codes (Technical Brief)

Model energy codes (MEC) describe requirements needed to demonstrate building energy performance compliance. They can be readily adopted by states and local jurisdictions to support desirable energy efficiency investment in new buildings and major renovations. This report provides commercial building energy code language as an overlay to current MEC, which is recognized by the U.S. DOE as ASHRAE Standard 90.1 2022. The code language provides a performance-based compliance path for achieving net zero energy or net zero operational energy emissions buildings with MEC. The path requires meeting two compliance metric target values: 1) a required minimum level of efficiency and 2) a measure of zero energy or emissions. The supporting documentation illustrates the magnitude of needed efficiency improvement and the additional offsets to be achieved from renewable energy sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy Efficiency in India: Compliance Evaluation of Energy Conservation Building Code

India is experiencing unprecedented construction boom. The country doubled its floorspace between 2001 and 2005 and is expected to add 35 billion m 2 of new buildings by 2050. Buildings account for 35% of total final energy consumption in India today, and building energy use is growing at 8% annually. Studies have shown that carbon policies will have little effect on reducing building energy demand. Chaturvedi et al. predicted that, if there is no specific sectoral policies to curb building energy use, final energy demand of the Indian building sector will grow over five times by the end of this century, driven by rapid income and population growth. The growing energy demand in buildings is accompanied by a transition from traditional biomass to commercial fuels, particularly an increase in electricity use. This also leads to a rapid increase in carbon emissions and aggravates power shortage in India. Growth in building energy use poses challenges to the Indian government.

Code Compliance Evaluation↗

Systematic approach to define a prototype building model: Convenience Store

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities, continuous efforts have been made to convert 30 prototype building models, which cover 80% of commercial building floor space in the United States, into OpenStudio Standards prototype buildings. In this paper, we provide a systematic approach to define the building and system characteristics of a convenience store, which has the largest energy use intensity among the commercial building types not covered by current prototype models. This study will be used as a basis for developing the prototype convenience store building model.

Yoon, Yeobeom↗

Multi-Year Program Plan - Building Regulatory Programs

This document presents DOE’s multi-year plan for the three components of the Buildings Regulatory Program: Appliance and Equipment Efficiency Standards, ENERGY STAR, and the Building Energy Codes Program. This document summarizes the history of these programs, the mission and goals of the programs, pertinent statutory requirements, and DOE’s 5-year plan for moving forward.

Appliance and Equipment Efficiency Standards↗

Developing Commercial Code Precalculated Packages

ACEEE Building Summer Study Conference paper to discuss the Developing Commercial Code Precalculated Packages as related to Building Energy codes and standards.

2016 ACEEE Summer Study on Energy Efficiency in Bu↗

West Virginia Residential Codes Study

The U.S. Department of Energy (DOE) Building Energy Codes Program launched a series of research studies in 2014 across several U.S. states to investigate typical energy efficiency practices in residential buildings and identify opportunities to reduce household utility bills. A primary goal of the study was to help document baseline practices in new single-family construction, target areas for improvement relative to the state energy code, and quantify related savings potential. This information was intended to assist states in measuring energy compliance with their codes and to identify areas of focus for future education and training initiatives. Following the original baseline studies, project teams in each state conducted a series of education, training and outreach activities aimed at improving compliance with the state residential energy code. A second baseline study was then implemented in several states with the objective of determining whether the investment in education, training and outreach programs had produced a significant and measurable change in statewide residential energy use. Through the program, DOE planned to establish a sufficient data set to represent baseline construction trends across states and detect significant changes in energy use resulting from education and training activities. The three basic phases employed were as follows: I. Pre-Study: A baseline study to identify the energy use in typical single-family residential buildings in a given state and opportunities for improving energy efficiency II. Education & Training: Education, training and outreach activities targeting issues identified through the baseline study III. Post-Study : A second study to identify the change in energy use following the education and training activities This report outlines the application of the study in the state of West Virginia with a focus on the experiences of the project team across the multi-phased approach. Data gathered through phase I has been submitted to Pacific Northwest National Laboratory (PNNL) for analysis. Findings available to date are published as PNNL technical reports on the DOE Building Energy Codes Program website with final analysis pending publication later in 2018.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Determination for the 2006 International Energy Conservation Code, Residential Buildings – Technical Support Document

Provides a technical analysis showing that the 2006 International Energy Conservation Code contains improvements in energy efficiency compared to its predecessor, the 2003 International Energy Conservation Code. DOE is required by law to issue "determinations" of whether or not new editions of the IECC improve energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Alabama Energy Code Compliance Project

The U.S. Department of Energy (DOE) Building Energy Codes Program launched a series of research studies in 2014 across eight U.S. states (shown in Figure 1) to investigate typical energy efficiency practices in residential buildings and identify opportunities to reduce household utility bills. A primary goal of the study was to help document baseline practices for new single-family construction, target areas for improvement relative to the state energy code, and quantify the related savings potential. This information is intended to assist states in measuring compliance with their energy codes and to identify areas of focus for future education and training initiatives. Following the original baseline studies, project teams in each state conducted a series of education, training, and outreach activities aimed at improving compliance with the state residential energy code. A second baseline study was then implemented in each state with the objective of determining whether the investment in education, training, and outreach programs had produced a significant and measurable change in statewide residential energy use. Through the program, DOE planned to establish a sufficient data set to represent baseline construction trends across states and detect significant changes in energy use resulting from education and training activities. This report outlines the application of the study in the state of Alabama, which was led by the Institute for Market Transformation (IMT). Data gathered have been submitted to Pacific Northwest National Laboratory (PNNL) for analysis. Findings available to date are published as PNNL technical reports on the DOE Building Energy Codes Program website.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HVAC Controls Guide for Plan Examiners and Building Inspectors

The information in this guide will make it easier to understand, apply, and validate compliance with heating, ventilation, and air-conditioning (HVAC) control requirements found in building energy codes .HVAC controls are a key driver of building performance from both energy and comfort standpoints, the latter of which impacts productivity, sales, and the general success of the activities in the buildings. Ensuring compliance with HVAC control requirements in the energy codes can be a challenging task; controls can be difficult to identify on plans and their proper installation and functionality are a challenge to assess in the field. The guide addresses requirements defined by the 2009 and 2012 IECC and the 2007 and 2010 editions of ASHRAE Standard 90.1, which are common bases for codes adopted by state and local jurisdictions.

HVAC, IECC, code compliance, thermostat, humidity↗

Residential Energy Code Compliance in The Southeast: Georgia and Arkansas

The U.S. Department of Energy (DOE) Building Energy Codes Program launched a series of research studies in 2014 across several U.S. states to investigate typical energy efficiency practices in residential buildings and identify opportunities to reduce household utility bills. A primary goal of the study was to help document baseline practices in new single-family construction, target areas for improvement relative to the state energy code, and quantify related savings potential. This information was intended to assist states in measuring energy compliance with their codes and to identify areas of focus for future education and training initiatives. Following the original baseline studies, project teams in each state conducted a series of education, training and outreach activities aimed at improving compliance with the state residential energy code. A second baseline study was then implemented in each state with the objective of determining whether the investment in education, training, and outreach programs had produced a significant and measurable change in statewide residential energy use. Through the program, DOE planned to establish a sufficient data set to represent baseline construction trends across states and detect significant changes in energy use resulting from education and training activities. The three basic phases employed in the study were as follows: I. Pre-Study : A baseline study to identify the energy use in typical single-family residential buildings in a given state and opportunities for improving energy efficiency II. Education & Training : Education, training, and outreach activities targeting issues identified through the baseline study III. Post-Study : A second study to identify the change in energy use following the education and training activities This report outlines the application of the study in the states of Arkansas, Georgia, Tennessee, and Virginia with a focus on the experiences of the project team across the “Pre-Study” and “Education and Training” phases. Data gathered through Phase I has been submitted to Pacific Northwest National Laboratory (PNNL) for analysis. Findings available to date are published as PNNL technical reports on the DOE Building Energy Codes Program website with Post-Study analysis pending publication in 2019.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of a Supermarket Prototype Building Model

The U.S. Department of Energy supports the development of commercial building energy codes and standards by participating in industry reviews, update processes, and providing technical analyses to support both published model codes and potential changes. In support of ANSI/ASHRAE/IES Standard 90.1 and the International Energy Conservation Code, 16 commercial prototype building models were developed that cover 80% of the commercial building floor area in the United States for new construction, including both commercial buildings and mid- to high-rise residential buildings, across all U.S. climate zones. However, the current set of commercial prototype building models does not include a supermarket building type, which is one of major building types defined in the Energy Information Administration’s Commercial Building Energy Consumption Survey. As part of an ongoing effort to expand the current Commercial Building Prototype Model suite, this paper presents the procedure used to develop the prototype supermarket building model based on multiple studies as well as a previously developed reference building model. The final set of prototype models includes 68 models for different vintages of ASHRAE Standard 90.1 (i.e., 2004, 2007, 2010, and 2013) and for 17 ASHRAE climate zones.

Im, Piljae↗

Prototype Supermarket Building Energy Model

The U.S. Department of Energy supports the development of commercial building energy codes and standards by participating in industry reviews, update processes, and providing technical analyses to support both published model codes and potential changes. In support of ANSI/ASHRAE/IES Standard 90.1 and the International Energy Conservation Code, 16 commercial prototype building models were developed that cover 80% of the commercial building floor area in the United States for new construction, including both commercial buildings and mid- to high-rise residential buildings, across all U.S. climate zones. However, the current set of commercial prototype building models does not include a supermarket building type, which is one of major building types defined in the Energy Information Administration’s Commercial Building Energy Consumption Survey. As part of an ongoing effort to expand the current Commercial Building Prototype Model suite, this report presents the procedure used to develop the prototype supermarket building model based on multiple studies as well as a previously developed reference building model. The final set of prototype models includes 60 models for different vintages of ASHRAE Standard 90.1 (i.e., 2004, 2007, 2010, and 2013) and for 15 ASHRAE climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Updated OpenStudio Small and Medium Office Prototype Models

The U.S. Department of Energy supports the development of commercial building energy codes and standards by participating in industry review, update processes, and providing technical analyses to support both published model codes and potential changes. In support of ANSI/ASHRAE/IES Standard 90.1 and International Energy Conservation Code, 16 commercial prototype building models were developed that cover 80% of the commercial building floor area in the United States for new construction, including both commercial buildings and mid- to high-rise residential buildings, across all U.S. climate zones. Of these, the small, medium, and large office buildings take about 12% of total commercial building floor area.Currently, small, medium, and large office prototype building models have simplified, single space type, while other building types includes more detailed space types. As such, the office prototype could not be easily used to properly assess changes (i.e. measures applied) to difference spaces commonly found in an office. This work has added new space types to the small and medium office, with properties based on several vintages of ASHRAE Standard 90.1 in different climate zones, and compared energy use of these newly-improved models with that of the original models.

Im, Piljae↗

Clean Energy in City Codes: A Baseline Analysis of Municipal Codification across the United States

Municipal governments in the United States are well positioned to influence clean energy (energy efficiency and alternative energy) and transportation technology and strategy implementation within their jurisdictions through planning, programs, and codification. Municipal governments are leveraging planning processes and programs to shape their energy futures. There is limited understanding in the literature related to codification, the primary way that municipal governments enact enforceable policies. The authors fill the gap in the literature by documenting the status of municipal codification of clean energy and transportation across the United States. More directly, we leverage online databases of municipal codes to develop national and state-specific representative samples of municipal governments by population size. Our analysis finds that municipal governments with the authority to set residential building energy codes within their jurisdictions frequently do so. In some cases, communities set codes higher than their respective state governments. Examination of codes across the nation indicates that municipal governments are employing their code as a policy mechanism to address clean energy and transportation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparison of Building Energy Modeling Programs: Building Loads

This technical report presented the methodologies, processes, and results of comparing three Building Energy Modeling Programs (BEMPs) for load calculations: EnergyPlus, DeST and DOE-2.1E. This joint effort, between Lawrence Berkeley National Laboratory, USA and Tsinghua University, China, was part of research projects under the US-China Clean Energy Research Center on Building Energy Efficiency (CERC-BEE). Energy Foundation, an industrial partner of CERC-BEE, was the co-sponsor of this study work. It is widely known that large discrepancies in simulation results can exist between different BEMPs. The result is a lack of confidence in building simulation amongst many users and stakeholders. In the fields of building energy code development and energy labeling programs where building simulation plays a key role, there are also confusing and misleading claims that some BEMPs are better than others. In order to address these problems, it is essential to identify and understand differences between widely-used BEMPs, and the impact of these differences on load simulation results, by detailed comparisons of these BEMPs from source code to results. The primary goal of this work was to research methods and processes that would allow a thorough scientific comparison of the BEMPs. The secondary goal was to provide a list of strengths and weaknesses for each BEMP, based on in-depth understandings of their modeling capabilities, mathematical algorithms, advantages and limitations. This is to guide the use of BEMPs in the design and retrofit of buildings, especially to support China’s building energy standard development and energy labeling program. The research findings could also serve as a good reference to improve the modeling capabilities and applications of the three BEMPs. The methodologies, processes, and analyses employed in the comparison work could also be used to compare other programs. The load calculation method of each program was analyzed and compared to identify the differences in solution algorithms, modeling assumptions and simplifications. Identifying inputs of each program and their default values or algorithms for load simulation was a critical step. These tend to be overlooked by users, but can lead to large discrepancies in simulation results. As weather data was an important input, weather file formats and weather variables used by each program were summarized. Some common mistakes in the weather data conversion process were discussed. ASHRAE Standard 140-2007 tests were carried out to test the fundamental modeling capabilities of the load calculations of the three BEMPs, where inputs for each test case were strictly defined and specified. The tests indicated that the cooling and heating load results of the three BEMPs fell mostly within the range of spread of results from other programs. Based on ASHRAE 140-2007 test results, the finer differences between DeST and EnergyPlus were further analyzed by designing and conducting additional tests. Potential key influencing factors (such as internal gains, air infiltration, convection coefficients of windows and opaque surfaces) were added one at a time to a simple base case with an analytical solution, to compare their relative impacts on load calculation results. Finally, special tests were designed and conducted aiming to ascertain the potential limitations of each program to perform accurate load calculations. The heat balance module was tested for both single and double zone cases. Furthermore, cooling and heating load calculations were compared between the three programs by varying the heat transfer between adjacent zones, the occupancy of the building, and the air-conditioning schedule.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial and Residential Hourly Load Profiles for all TMY3 Locations in the United States

Note: This dataset has been superseded by the dataset found at "End-Use Load Profiles for the U.S. Building Stock" (submission 4520; linked in the submission resources), which is a comprehensive and validated representation of hourly load profiles in the U.S. commercial and residential building stock. The End-Use Load Profiles project website includes links to data viewers for this new dataset. For documentation of dataset validation, model calibration, and uncertainty quantification, see Wilson et al. (2022). These data were first created around 2012 as a byproduct of various analyses of solar photovoltaics and solar water heating (see references below for are two examples). This dataset contains several errors and limitations. It is recommended that users of this dataset transition to the updated version of the dataset posted in the resources. This dataset contains weather data, commercial load profile data, and residential load profile data. Weather The Typical Meteorological Year 3 (TMY3) provides one year of hourly data for around 1,000 locations. The TMY weather represents 30-year normals, which are typical weather conditions over a 30-year period. Commercial The commercial load profiles included are the 16 ASHRAE 90.1-2004 DOE Commercial Prototype Models simulated in all TMY3 locations, with building insulation levels changing based on ASHRAE 90.1-2004 requirements in each climate zone. The folder names within each resource represent the weather station location of the profiles, whereas the file names represent the building type and the representative city for the ASHRAE climate zone that was used to determine code compliance insulation levels. As indicated by the file names, all building models represent construction that complied with the ASHRAE 90.1-2004 building energy code requirements. No older or newer vintages of buildings are represented. Residential The BASE residential load profiles are five EnergyPlus models (one per climate region) representing 2009 IECC construction single-family detached homes simulated in all TMY3 locations. No older or newer vintages of buildings are represented. Each of the five climate regions include only one heating fuel type; electric heating is only found in the Hot-Humid climate. Air conditioning is not found in the Marine climate region. One major issue with the residential profiles is that for each of the five climate zones, certain location-specific algorithms from one city were applied to entire climate zones. For example, in the Hot-Humid files, the heating season calculated for Tampa, FL (December 1 - March 31) was unknowingly applied to all other locations in the Hot-Humid zone, which restricts heating operation outside of those days (for example, heating is disabled in Dallas, TX during cold weather in November). This causes the heating energy to be artificially low in colder parts of that climate zone, and conversely the cooling season restriction leads to artificially low cooling energy use in hotter parts of each climate zone. Additionally, the ground temperatures for the representative city were used across the entire climate zone. This affects water heating energy use (because inlet cold water temperature depends on ground temperature) and heating/cooling energy use (because of ground heat transfer through foundation walls and floors). Representative cities were Tampa, FL (Hot-Humid), El Paso, TX (Mixed-Dry/Hot-Dry), Memphis, TN (Mixed-Humid), Arcata, CA (Marine), and Billings, MT (Cold/Very-Cold). The residential dataset includes a HIGH building load profile that was intended to provide a rough approximation of older home vintages, but it combines poor thermal insulation with larger house size, tighter thermostat setpoints, and less efficient HVAC equipment. Conversely, the LOW building combines excellent thermal insulation with smaller house size, wider thermostat setpoints, and more efficient HVAC equipment. However, it is not known how well these ...

Array↗