Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building occupancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Evaluating Thermostats’ Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies

Thermostats play a crucial role in energy consumption, user control, and occupant comfort by serving as the interface between the heating, ventilation, and air conditioning (HVAC) system and the building's occupants. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on or off. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different thermostats, tested with a residential heat pump, aiming to identify variations in their deadband settings and implications for energy usage and management. The experimental study was conducted using a HVAC hardware-in-the-loop (HIL) system that allows thermostats to be connected with physical HVAC equipment, driven by conditions in a simulated residential building. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats cycle differently based on their deadband settings. The findings offer valuable insights into how thermostat deadband affects comfort and energy use, as well as the cycling frequency of a heat pump.

Ramaraj, Sugirdhalakshmi [National Renewable Energ↗

Performance Simulation and Analysis of Occupancy-Based Control for Office Buildings with Variable-Air-Volume Systems

Variable-air-volume (VAV) systems are used in many office buildings. The minimum airflow rate setting of VAV terminal boxes has a significant impact on both energy consumption and indoor air quality. Conventional controls usually have the terminal’s minimum airflow rate at a constant (e.g., 30% or more of the terminal design airflow rate), irrespective of the occupancy status, which may cause problems, such as excessive simultaneous heating and cooling, under ventilation, and thermal comfort issues. This paper examines the potential of energy savings from occupancy-based controls (OBCs). The sensed occupancy information, either occupant presence or people count, is used to determine the airflow rate of terminal boxes, the thermostat setpoints, and the lighting control. Using EnergyPlus, a whole-building energy modeling software, the energy savings of OBC strategies are evaluated for representative existing medium office buildings in the U.S. The simulation results show that the conventional OBC, based on occupant presence sensing, can save 8% of whole-building energy use in Miami (hot climate) for systems without air-side economizer and about 13% in both Baltimore (mixed climate) and Chicago (cold climate). Comparatively, the advanced OBC, based on people counting, can save 8% in Miami to 23% in Baltimore for systems with economizers. The outdoor-air fraction of the supply air from air-handling units significantly affects the potential energy savings from the advanced OBC strategy. In addition to energy savings, the advanced OBC satisfies the zone ventilation during all occupied hours over the whole year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Review of Existing Test Methods for Occupancy Sensors

One of the key new features of connected lighting systems (CLS) is their ability to collect data from various types of integral sensors and share that data with other lighting or building systems. Occupancy and vacancy sensors have been widely adopted as an energy-saving strategy in buildings, yet published test methods for reproducibly characterizing their performance remain few and limited in their sophistication. As a result, it has been difficult to predict their performance in a specific application, and in practice, they frequently do not meet energy-savings expectations. Occupants at times remove or otherwise bypass occupancy sensors that hinder their work or otherwise do not perform as expected, thereby compromising the sensors’ potential to reduce energy consumption. Poor performance can result from multiple causes – ranging from fundamental limitations of the sensor technology, to misconfiguration, to poor placement in the room or space. Innovative occupancy sensors, some of them combining multiple sensing technologies, have come on the market over the years, with claims of improved performance compared to their predecessors; yet in practice, their performance has led to neither high deployment nor high user satisfaction in any significant application, nor has it differed enough from the performance of previous products to necessitate a test method that facilitated comparison between them. While the performance of both common and novel occupancy sensors has been the subject of many published research articles, the test methods that have been employed for them have typically been loosely described and incorporated custom equipment or techniques that render them difficult to reproduce, or have been limited in their ability to fairly characterize devices that utilize varying sensor technology. The lack of a well-described, technology-agnostic test method that yields reproducible results across different implementations has been a barrier to the commercial success of new occupancy sensor products, as users and specifiers who have been disappointed with previous products are often unwilling to take a chance with new ones. Motivated by a desire to fairly characterize new technologies that continue to enter the market and claim not only improved occupancy detection but, in some cases, also additional capabilities (e.g., the ability to measure traffic or discern between different object types), this report presents the results of a literature review of recent published, well-described test methods for characterizing occupancy sensor performance, as well as research articles containing ad-hoc test methods. The review also identifies and consolidates the best techniques for characterizing sensor performance in indoor spaces and identifies test method gaps that need to be filled in order to evaluate emerging technologies and products.

47 OTHER INSTRUMENTATION↗

Occupancy schedule development and its effect on OpenStudio prototype college building model

College buildings have unique characteristics compared with school buildings. Therefore, defining the realistic occupancy schedule in a prototype college building has significant research opportunities. In this study, the actual operating schedules of each space type were collected and generated based on the class reservation schedule and compared with the previous reference schedule (primary/secondary school). Here, the schedules were analyzed for their effect on the OpenStudio prototype college building model. The findings highlight that the use of a typical school building schedule in a college building impairs the granularity of information. The analysis shows significant differences between the previous occupancy schedule and the updated occupancy schedule of the college building, leading to a considerable decrease in occupancy density. Furthermore, the effect of these occupancy pattern changes on the prototype building model is examined. The variations were observed in minimum ventilation requirements, the average mechanical ventilation rate, and energy consumption attributed to changes in occupancy density.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Fidelity Building Emulator for Integrated Comfort and Energy Analysis using EnergyPlus and Radiance

The growing need for smart, energy-efficient, and occupant-centric buildings has created a demand for advanced control systems that can optimize building operations to balance energy savings, demand flexibility, and comfort. However, current building energy simulation tools, such as EnergyPlus, have limitations that hinder the development and evaluation of these complex control systems. To address this challenge, we introduce a high-fidelity building emulator that dynamically couples EnergyPlus with Radiance for enhanced daylight modeling. The introduced workflow allows researchers and practitioners to rapidly develop and evaluate innovative control solutions. An example study looking at a south-facing office zone revealed up to 67% deviation in predicted light levels, which can significantly impact building assessment.

Yu, Tammie↗

Optimizing HVAC Operations in Multi-unit Buildings for Grid Demand Response

The thermal inertia of buildings, along with the flexibility associated with thermostatically controlled loads (TCL) allows heating ventilation and cooling (HVAC) systems to be used for grid demand response (DR). In this work, we consider an HVAC system that serves multiple units in a residential building to meet their space heating requirements. We aim to determine the optimal power flow to each unit that minimizes the power costs incurred by the building's occupants while keeping in consideration their thermal comfort. The DR program is assumed to allow the building temperatures to deviate from the set-points up to a maximum limit. Despite the complex, non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using quadratic programming. Since HVAC systems can run on either electricity or natural gas, we study the efficacy of the DR regime for both hourly electricity prices and flat gas prices over the course of 24 hours. Finally, we run simulations to determine the optimal thermal power and the evolution of unit temperatures for various energy pricing schemes.

Naqvi, Syed A.↗

Air Return Strategies and Airborne SARS-CoV-2

Dedicated ducted air return per zone for heating, ventilating, and air-conditioning (HVAC) systems is sometimes claimed to be a superior technique over plenum return strategy from the viewpoint of exposure reduction to airborne pathogens. While both the return strategies have advantages, there is limited evidence in the literature as to which strategy is superior merely from a standpoint of building vulnerability to airborne contaminants. We performed multizonal airborne contaminant dispersion modelling using CONTAM to simulate the overall building vulnerability to airborne SARS-CoV-2 aerosols when released in an office building and evaluated the two air return strategies. Results showed that for ducted returns, maintaining negative pressure in the release zone coupled with 100% outdoor air supply can greatly reduce overall building vulnerability. However, for a building maintained under a slight positive pressure and a recirculated air percentage as low as 31%, ducted returns do not necessarily outperform plenum returns in terms of overall building vulnerability to airborne pathogens. Building-specific details and factors that are not easily represented with multizone modelling are important, making general preferential statements for either strategy difficult to make. Insights from this study can guide new construction and retrofits of buildings both during and after the COVID-19 pandemic with the aim of safe re-occupancy of buildings while keeping the buildings resilient against potential future epidemics spread by airborne agents.

Shrestha, Prateek↗

Modelling urban-scale occupant behaviour, mobility, and energy in buildings: A survey

The proliferation of urban sensing, IoT, and big data in cities provides unprecedented opportunities for a deeper understanding of occupant behaviour and energy usage patterns at the urban scale. This enables data-driven building and energy models to capture the urban dynamics, specifically the intrinsic occupant and energy use behavioural profiles that are not usually considered in traditional models. Although there are related reviews, none have investigated urban data for use in modelling occupant behaviour and energy use at multiple scales, from buildings to neighbourhood to city. This survey paper aims to fill this gap by providing a critical summary and analysis of the works reported in the literature. We present the different sources of occupant-centric urban data that are useful for data-driven modelling and categorise the range of applications and recent data-driven modelling techniques for urban behaviour and energy modelling, along with the traditional stochastic and simulation-based approaches. Finally, we present a set of recommendations for future directions in data-driven modelling of occupant behaviour and energy in buildings at the urban scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Leveraging Fine-Grained Occupancy Estimation Patterns for Effective HVAC Control

As occupancy sensing technologies become mature, various occupancy sensors are increasingly deployed in commercial buildings for pervasive occupancy monitoring. These sensors provide occupant-count data, which contains rich spatiotemporal information about occupancy patterns. With long-term occupant-count data collected from a commercial building, we design three different predictive models that capture the occupancy dynamics and examine how a model predictive control of the HVAC system benefits from actual occupancy count prediction. Our analysis reveals that mispredictions of occupancy states, especially false positives and false negatives, may introduce inefficient control that leads to energy waste or user discomfort. To address this issue, we take a step further to design an adaptive model predictive controller that minimizes inefficient control actions according to misprediction types and distributions. A comprehensive evaluation is performed in OpenBuild and EnergyPlus simulators to study the effectiveness of the proposed end-to-end control strategy. The evaluation shows that the proposed solution reduces energy consumption by 29.5% while improving the average weighted occupants comfort by 86.7% in Predicted Mean Vote (PMV) over the fixed schedule strategy.

97 MATHEMATICS AND COMPUTING↗

Advanced co-simulation framework for assessing the interplay between occupant behaviors and demand flexibility in commercial buildings

With buildings contributing significantly to electricity usage, enabling demand flexibility becomes a challenge, especially when accounting for occupant comfort. This study introduces an innovative co-simulation framework integrating multiple models: heating, ventilation, and air conditioning (HVAC) system, building zone load, indoor airflow, supervisory control, and occupant comfort and behavior. Uniquely, this framework allows for a comprehensive and dynamic analysis of building systems and occupant interactions in demand response events. Using this framework, we conducted a case study using a typical small office building model. Specifically, we focused on three areas: (1) the impact of indoor airflow modeling on energy use, occupant comfort, and behaviors forecasting, (2) the impact of occupant behaviors on demand flexibility, and (3) occupant comfort and behaviors under demand response events. Key performance indicators such as energy use, flexibility factor, durations of occupant discomfort and occupant behaviors were analyzed. Our findings indicated variations in energy usage and occupant comfort within demand flexibility events, marked by uncertainty boundaries, with variability in demand shedding up to 57.9%. Here, we concluded that this framework is suitable for analyzing typical commercial buildings and their HVAC systems in terms of demand flexibility potential under the impact of occupant behaviors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Opportunities to Expand Building Efficiency Programming at Community Colleges

According to the most recent U.S. Energy and Employment Report, more than 2.3 million workers in the United States are involved in activities that reduce energy usage in buildings. This workforce supports energy efficiency from the design of buildings and their systems through the manufacturing and trade of components and supplies involved in these systems to the installation, repair, and maintenance of these systems. Less than 10% of the workers in key building efficiency occupations have a bachelor’s or higher degree, compared to ~40% of the general workforce. Thus, the community college system is a key stakeholder in training and educating a large portion of the building efficiency workforce. Despite this, the literature review conducted for this report found almost no research focused on better understanding and supporting the role of community colleges as they train this workforce at scale. This report seeks to understand how and to what extent building efficiency and advanced building technology concepts are being addressed in community colleges as well as potential pathways for schools to consider to better prepare students to enter the building efficiency industry. The first section presents information from a literature review and data analysis to provide background on the building efficiency workforce, the types of building efficiency training and education available from community colleges, and the barriers and challenges that exist in the workforce. The second section offers a series of case studies that illustrate the various ways that building efficiency content can be addressed at community colleges. The final section provides an overview of the opportunities available to community colleges as well as considerations for schools that want to increase building efficiency programming.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Linking human-building interactions in shared offices with personality traits

Occupant behavior influences office building energy performance. The level of human-building interactions (HBIs) in shared offices strongly influences building energy use and occupant well-being. This study explored the link between occupant personality types and their behaviors of sharing energy and environment control systems and interactions with their colleagues. Inspired by the Five-Factor Model (FFM), we classified HBI behaviors into four dimensions: willingness to share control, knowledge of control, group decision behavior, and adaptive strategies. These four variables can be mapped to the four personality traits proposed by the FFM: agreeableness, openness, extraversion, and conscientiousness. Our cluster analysis identified six behavioral patterns: average (17.7%), reserved (15.3%), environmentally friendly (16.6%), role model (24.2%), self-centered (17.2%), and mechanist (9.0%). We further applied association rules, a widely utilized machine learning technique, to discover how demographics, building-related contextual factors, and perception-attitudinal factors influence HBI behaviors. Country, control feature accessibility, and group dynamics were found to be the three most influential factors that determine occupants’ HBI behaviors. Finally, the study provides insights about building design and operation, as well as policy to promote socially and environmentally desirable HBI behaviors in a shared office environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New health and safety initiatives at the Department of Energy (DOE)

This document touches on some of the more important lessons learned and the more noteworthy initiatives DOE has put into motion in the last three years to protect the health and safety of our contractor employees. What we have learned in the process should come as no surprise to those of you who have been working in the field: (1) that management commitment to safety and health is critical to a successful program; (2) that meaningful employee participation in all aspects of the program enhances its effectiveness at every level; and (3) that the dedication and expertise of medical and occupational safety and health professionals are needed if the challenging problems presented by the complex and technologically advanced environment at DOE facilities are to be overcome. I believe that we have made a good beginning in the long and arduous task of building an Occupational Safety and Health Program that will serve as a model for others, and I can assure you that we intend to continue our efforts to protect every worker within the complex from occupational injury and disease.

Ziemer, Paul L.↗

Model predictive control of heating, ventilation, and air conditioning (HVAC) systems: A state-of-the-art review

Due to the fast advancement of communication and information technology, intelligent buildings have garnered great interest. These buildings can forecast weather, ambient temperature, and sun irradiation and can modify heating, ventilation, and air conditioning (HVAC) operations appropriately, based on current and previous data. This change is intended to reduce HVAC system energy usage while maintaining an appropriate degree of thermal comfort and indoor air quality. Since its inception, model predictive control (MPC) has been one of the prospective solutions for HVAC management systems to reduce both costs and energy usage. Additionally, MPC is becoming increasingly practical as the processing capacity of building automation systems increases and a large quantity of monitored building data becomes available. MPC also provides the potential to improve the energy efficiency of HVAC systems via its capacity to consider limitations, to predict disruptions, and to factor in multiple competing goals such as interior thermal comfort and building energy consumption. Although substantial research has been conducted on MPC in building HVAC systems, there is a shortage of critical reviews and a lack of a comprehensive framework that formulates and defines the applications. Here, this article provides a comprehensive state-of-the-art overview of MPC in HVAC systems. Detailed discussions of modeling approaches and optimization algorithms are included. Numerous design aspects such as prediction horizon, occupancy behavior, building type, and cost function, that impact MPC performance are discussed in detail. The technical characteristics, advantages, and disadvantages of various types of modeling software are discussed. The primary objective of this work is to highlight critical design characteristics for the MPC control scheme and to give improved suggestions for future research. Moreover, numerous prospective scenarios have been suggested that might provide future research direction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hardware-Based Emulator with Deep Learning Model for Building Energy Control and Prediction Based on Occupancy Sensors’ Data

Heating, ventilation, and air conditioning (HVAC) is the largest source of residential energy consumption. Occupancy sensors’ data can be used for HVAC control since it indicates the number of people in the building. HVAC and sensors form a typical cyber-physical system (CPS). In this paper, we aim to build a hardware-based emulation platform to study the occupancy data’s features, which can be further extracted by using machine learning models. In particular, we propose two hardware-based emulators to investigate the use of wired/wireless communication interfaces for occupancy sensor-based building CPS control, and the use of deep learning to predict the building energy consumption with the sensor data. We hypothesize is that the building energy consumption may be predicted by using the occupancy data collected by the sensors, and question what type of prediction model should be used to accurately predict the energy load. Another hypothesis is that an in-lab hardware/software platform could be built to emulate the occupancy sensing process. The machine learning algorithms can then be used to analyze the energy load based on the sensing data. To test the emulator, the occupancy data from the sensors is used to predict energy consumption. The synchronization scheme between sensors and the HVAC server will be discussed. We have built two hardware/software emulation platforms to investigate the sensor/HVAC integration strategies, and used an enhanced deep learning model—which has sequence-to-sequence long short-term memory (Seq2Seq LSTM)—with an attention model to predict the building energy consumption with the preservation of the intrinsic patterns. Because the long-range temporal dependencies are captured, the Seq2Seq models may provide a higher accuracy by using LSTM architectures with encoder and decoder. Meanwhile, LSTMs can capture the temporal and spatial patterns of time series data. The attention model can highlight the most relevant input information in the energy prediction by allocating the attention weights. The communication overhead between the sensors and the HVAC control server can also be alleviated via the attention mechanism, which can automatically ignore the irrelevant information and amplify the relevant information during CNN training. Our experiments and performance analysis show that, compared with the traditional LSTM neural network, the performance of the proposed method has a 30% higher prediction accuracy.

Ye, Zhijing↗

Tool for Developing Integrated Strategies for Decontamination and Waste Management - 20291

Management of waste from chemical, biological, and radiological incidents is complicated by the fact that decontamination decisions have a profound impact on the characteristics of resulting waste streams. Wide-area biological and radiological incidents could produce massive quantities of waste that may need to be treated on-site and sent for subsequent disposal as non-contaminated materials, or else be directly disposed of as contaminated materials. The EPA has developed the Waste Estimation Support Tool (WEST) for characterizing and quantifying biological and radiological waste that may be generated from decontamination efforts. This paper focuses on the WEST's uses for radiological incidents. WEST combines Geographic Information System (GIS)-based analysis of externally-supplied plume data, infrastructure databases derived from the Federal Emergency Management Agency's (FEMA's) Hazus tool [1], and satellite imagery surface recognition algorithms to combine the composition and square footage of the buildings in the plume with estimates of the materials between the buildings in the plume. The resulting GIS data files are then imported into a Microsoft Access database application, where they are combined with information about the nature and concentration of contaminants, and then subjected to decontamination strategies for different contaminated surfaces. The tool provides estimates of the type and quantities of potential wastes resulting from simulated decontamination and/or demolition activities and includes estimates of the remaining contamination levels including residual contamination contained within each waste stream. Estimates are presented at several levels of detail, allowing users to obtain needed data at the desired resolution. These include estimates for the total affected area, estimates by contamination zone, estimates by decontamination method(s), and estimates by building type (occupancy classification). EPA is currently developing the next version of WEST which will include several substantial enhancements. The most significant improvement for the next version of WEST will include the ability for users to develop contamination scenarios and waste estimates based on previously developed, readily available, and geographically specific infrastructure data. Instead of using WEST's default infrastructure data based on FEMA's Hazus tool, users will be able to import their own building data specific to the geographically affected area. This capability may substantially decrease uncertainties in the resulting waste estimates because the results will be based on actual building data (numbers of each type, square footage, building height, etc.). Two other significant enhancements will be the ability to generate waste estimates for vehicles and biomass. In addition to building debris and building decontamination waste, vehicles and biomass will likely constitute a significant percentage of the total waste which may result from wide area contamination events. This presentation will present the most recent version of WEST, which includes such considerations as affected biomass (e.g., trees), vehicles, and the ability to replace the default Hazus infrastructure databases with custom infrastructure databases. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alaska's Rural Building Stock: a Validation Study Using ResStock and Field Data

The availability of accurate national data on demographics, building stock, and energy use is vital for modeling residential buildings and evaluating decarbonization strategies. However, rural and Indigenous populations, including those in rural Alaska, are typically underrepresented in these datasets. These communities face unique challenges due to their remote locations, severe weather conditions, and limited access to resources, resulting in high energy burden. This report examines how rural Alaskan communities are underrepresented in the ResStock housing model and highlights the need for improved data to address their unique housing and energy challenges. Thus, this report examines the representation of rural Alaskan communities within the national housing stock model, ResStock. A validation study was conducted, considering ResStock, Field Data and Aerial and 3D-view data collection (A3DDC) datasets. The validation process started by using the down selecting approach on the ResStock building stock dataset. For the purpose of this study, only the rural Alaska Boroughs and Census areas located in ASHRAE IECC Climate Zone 8 were considered to ensure a more accurate and fair comparison with the field data, which was collected in rural areas located in climate zone 8, specifically within the Nome Census area. While ResStock may accurately represent several characteristics of the building stock for rural Alaska, some differences between modeled, field data, and aerial and 3D-view data collection datasets were identified. The following building characteristics have a high impact on modeled energy consumption and demonstrated large differences: Revisit heating setpoints and consider a substantially higher setpoint distribution, it could potentially address "missing loads" if this is the case. Develop and include Toyo heating in future modeling for ResStock and EnergyPlus. Remove natural gas as a water heater fuel type outside of North Slope County. Foundation type updated to have more crawlspaces rather than basements. Infiltration rates need reexamination for a larger distribution toward higher infiltration rates. Include more vinyl and less brick in exterior wall type and revise wall color for greater proportion of light rather than dark color. Roof material revised from majority shingles to majority metal. Update number of occupants to higher number of occupant count. Building orientation represents a higher proportion of south facing buildings rather than relatively equal. The findings suggest that updating ResStock's probability logic could better represent rural Alaskan buildings. ResStock can be utilized to identify the best upgrades or energy efficiency and energy efficiency improvements, helping community leaders in making more informed decisions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Post-occupancy evaluation of indoor environmental quality in ten nonresidential buildings in Chongqing, China

Indoor environmental quality (IEQ) is an essential element of sustainable building performance. To advance knowledge of indoor environmental quality in Chinese nonresidential buildings, this study conducted post-occupancy evaluation (POE) in varied use areas within schools, hospitals, offices, hotels and shopping malls through environmental measurements and occupant surveys in 10 buildings over four seasons in Chongqing, China. Measured thermal conditions were more frequently within comfort standards in winter than in summer according to the predicted mean vote – predicted percentage dissatisfied model; but the model did not reliably predict thermal satisfaction. There was insufficient illuminance in 28% of studied areas and high illuminance in shopping malls led to complaints about glare. Sound pressure exceeded the Chinese guideline in all buildings with shopping malls having significantly higher levels than other buildings. CO 2 was generally below the Chinese national guideline of 1000 ppm; the two percent of measurements that exceeded the guideline occurred in classrooms, hospital wards and underground supermarkets. Formaldehyde did not exceed the limit level of 0.1 mg/m3 in any space. Most of the buildings did not provide effective protection from outdoor fine particulate matter (PM2.5), and infiltration from outdoors was the main factor for exceeding health-based guidelines indoors. Shopping malls had lower IEQ satisfaction than offices, schools and hospitals. Sound was the factor with the lowest satisfaction level among the four principal environmental factors. Overall, this study demonstrates value of POE on identifying deficiencies in indoor environment and provides a reference for assessment of IEQ in nonresidential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗