On Variations of Space-heating Energy Use in Office Buildings

Space heating is the largest energy end use, consuming more than 7 quintillion joules of site energy annually in the U.S. building sector. A few recent studies showed discrepancies in simulated space-heating energy use among different building energy modeling programs, and the simulated results are suspected to be underpredicting reality. While various uncertainties are associated with building simulations, especially when simulations are performed by different modelers using different simulation programs for buildings with different configurations, it is crucial to identify and evaluate key driving factors to space-heating energy use in order to support the design and operation of low-energy buildings. In this study, 10 design and operation parameters for space-heating systems of two prototypical office buildings in each of three U.S. heating climates are identified and evaluated, using building simulations with EnergyPlus, to determine the most influential parameters and their impacts on variations of space-heating energy use. The influence of annual weather change on space-heating energy is also investigated using 30-year actual weather data. The simulated space-heating energy use is further benchmarked against those from similar actual office buildings in two U.S. commercial-building databases to better understand the discrepancies between simulated and actual energy use. In summary, variations of both the simulated and actual space-heating energy use of office buildings in all three heating climates can be very large. However these variations are mostly driven by a few influential parameters related to building design and operation. The findings provide insights for building designers, owners, operators, and energy policy makers to make better decisions on energy-efficiency technologies to reduce space-heating energy use for both new and existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupled Induction Machine and HVAC Models for Simulating HVAC Performance Considering Grid Dynamics in Buildings

This paper presents the development of novel models that integrate induction machines with HVAC equipment, such as pumps, heat pumps, and chillers, to analyze the impact of electrical parameters on the operational performance of thermo-fluid systems. The proposed model employs a coupling technique that captures the dynamic interactions between induction machines and HVAC systems. By integrating electrical, thermal, and mechanical dynamics, the models provide a comprehensive framework for simulating real-world scenarios, including interactions with the electrical grid. This achievement was made possible through the development of a Computationally Efficient and Accurate Induction Machine (CEAIM) model. Implemented using the equation-based Modelica language, the CEAIM model has been validated against experimental results, manufacturer data sheets, and various operating conditions. Its performance has been compared with existing induction machine models in the Modelica Standard Library (MSL), demonstrating superior accuracy and computational efficiency. The CEAIM model predicts torque, speed, and power consumption with a coefficient of determination (R 2 ) ranging from 0.98 to 1 and a coefficient of variation of root mean square error (CVRMSE) between 0.27% and 6.67%. Additionally, CEAIM scales more efficiently than conventional MSL models, with a slower computational growth rate in large-scale simulations. After thorough validation of the CEAIM model, it was coupled with HVAC equipment as this approach provides a detailed multi-dimensional view of capturing electrical transients and mechanical performance. To support this, a case study was conducted to showcase its capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rooftop unit comparison calculator: a framework for comparing performance of rooftop units with building energy simulation

The applications of building energy simulation (BES) in designing heating, ventilation, and air conditioning (HVAC) systems are limited by the high costs of developing simulation models and the lack of references for determining the model parameters. This paper presents a software framework for selecting designs for rooftop unit HVAC (RTU) systems with BES. Specifically, this framework reduces the cost of using BES by automating the generation of EnergyPlus models. It also employs a systematic method for determining model parameters based on well-accepted datasets. We applied this framework in a comprehensive assessment of an advanced design of RTU systems in which 478 EnergyPlus models were developed without human involvement. The assessment reveals that replacing a constant-speed fan/coil with a multiple-speed fan/coil may not guarantee better overall performance. In conclusion, it also suggests the benefits of replacing furnace coils with heat pumps are subject to utility cost, weather conditions, and heating load profiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation-aided occupant-centric building design: A critical review of tools, methods, and applications

Occupants are active participants in their built environment, affecting its performance while simultaneously being affected by its design and indoor environmental conditions. With recent advances in computer modeling, simulation tools, and analysis techniques, topics such as human-building interactions and occupant behavior have gained significant interest in the literature given their premise of improving building design processes and operating strategies. In practice, the focus of occupant-centric literature has been mostly geared towards the latter (i.e., operation), leaving the implications on building design practices underexplored. This paper fills the gap by providing a critical review of existing studies applying computer-based modeling and simulation to guide occupant-centric building design. The reviewed papers are organized along four main themes, namely occupant-centric: (i) metrics of building performance, (ii) modeling and simulation approaches, (iii) design methods and applications, and (iv) supporting practices and mechanisms. Important barriers are identified for a more effective application of occupant-centric building design practices, including the limited consideration of metrics beyond energy efficiency (e.g., occupant well-being and space planning), the limited implementation and validation of the proposed methods, and the lack of integration of occupant behavior modeling in existing building performance simulation tools. Finally, future research directions are discussed, covering large-scale international data collection efforts to move from generic assumptions about occupant behavior to specific/localized knowledge, improved metrics of measuring building performance, and improved industry practices, such as building codes, to promote an occupant-in-the-loop approach to the building design process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupling fast fluid dynamics and multizone airflow models in Modelica Buildings library to simulate the dynamics of HVAC systems

Multizone models are widely used in building airflow and energy performance simulations due to their fast computing speed. However, multizone models assume that the air in a room is well mixed, consequently limiting their application. In specific rooms where this assumption fails, the use of computational fluid dynamics (CFD) models may be an alternative option. Previous research has mainly focused on coupling CFD models and multizone models to study airflow in large spaces. While significant, most of these analyses did not consider the coupled simulation of the building airflow with the building’s Heating, Ventilation, and Air-Conditioning (HVAC) systems. This paper tries to fill the gap by integrating the models for HVAC systems with coupled multizone and CFD simulations for airflows, using the Modelica simulation platform. To improve the computational efficiency, we incorporated a simplified CFD model named fast fluid dynamics (FFD). We first introduce the data synchronization strategy and implementation in Modelica. Then, we verify the implementation using two case studies involving an isothermal and a non-isothermal flow by comparing model simulations to experiment data. Afterward, we study another three cases that are deemed more realistic. Furthermore, this is done by attaching a variable air volume (VAV) terminal box and a VAV system to previous flows to assess the capability of the models in studying the dynamic control of HVAC systems. Finally, we discuss further research needs on the coupled simulation using the models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation and Field Evaluation Support for ESTCP Dynamic Windows: Cooperative Research and Development Final Report, CRADA Number CRD-12-492

We will leverage new building performance and daylighting simulation tools to characterize the performance of a new electrochromic (EC) glazing as well as perform a field evaluation of the same product installed in a DoD facility. The in situ data will be used to validate and calibrate the simulation model, which will then be used to extrapolate the performance of the product across all US climate zones. The property as part of this agreement will be installed at MCAS Miramar, California.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation-based characterization of the variability of earthquake risk to buildings in the near-field

Recent advancements in high performance computing platforms and computational workflow for regional-scale simulations are enabling unprecedented modeling of fault-to-structure earthquake processes. Regional simulations resolving ground motions at frequencies relevant to engineered systems are becoming computationally viable and provide a new capability to improve understanding of the geographical distribution and intensity of risk to buildings and critical infrastructure. As computational capabilities advance, it is essential to move beyond illustrative single rupture realizations for scenario earthquake events towards the development of a full suite of rupture realizations that appropriately characterize the range of risk to building systems. The work described in this article investigates the application of a suite of fault rupture realizations with the objective of assessing near-fault, site-specific seismic demand variability for building structures. A representative high-performance regional-scale computational model is utilized to execute ground motion and building response simulations based on 18 kinematic rupture realizations of an M7 strike-slip scenario earthquake. The fault rupture models for the scenario earthquake are created by systematically perturbing the hypocenter location and stochastically generating rupture parameters (slip, rise time, rake angle) to represent a breadth of ground motion intensities resulting from the spatial and temporal variabilities of an earthquake rupture process. The resulting seismic demand variability for three-story (short period) and forty-story (long period) steel moment-resisting frame buildings is characterized in terms of the median and distribution of peak inter-story drift ratio for a range of near-fault sites. The full suite of 18 fault rupture realizations and approximately 280,000 nonlinear dynamic building simulations indicate that the three-story building undergoes higher median seismic demand and significantly greater variability of demand at a given site than the forty-story building, which has important implications for the level of certainty in predicting building performance during an earthquake. The simulations performed provide deeper insight into the relationship between fault rupture parameterization and building response, which is essential information for developing a representative suite of rupture realizations for specific earthquake scenarios.

58 GEOSCIENCES↗

Development of city buildings dataset for urban building energy modeling

Urban building energy modeling (UBEM) is becoming a proven tool to support energy efficiency programs for buildings in cities. Development of a city-scale dataset of the existing building stock is a critical step of UBEM to automatically generate energy models of urban buildings and simulate their performance. This study introduces data needs, data standards, and data sources to develop city building datasets for UBEM. First, a literature review of data needs for UBEM was conducted. Then, the capabilities of the current data standards for city building datasets were reviewed. Moreover, the existing public data sources from several pioneer cites were studied to evaluate whether they are adequate to support UBEM. The results show that most cities have adequate public data to support UBEM; however, the data are represented in different formats without standardization, and there is a lack of common keys to make the data mapping easier. Finally, a case study is presented to integrate the diverse data sources from multiple city departments of San Francisco. The data mapping process is introduced and discussed. It is recommended to use the unique building identifiers as the common keys in the data sources to simplify the data mapping process. Furthermore, the integration methods and workflow are applied to other U.S. cities for developing the city-scale datasets of their existing building stock, including San Jose, Los Angeles, and Boston.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A High-Granularity Approach to Modeling Energy Consumption and Savings Potential in the U.S. Residential Building Stock

Building simulations are increasingly used in various applications related to energy efficient buildings. For individual buildings, applications include: design of new buildings, prediction of retrofit savings, ratings, performance path code compliance and qualification for incentives. Beyond individual building applications, larger scale applications (across the stock of buildings at various scales: national, regional and state) include: codes and standards development, utility program design, regional/state planning, and technology assessments. For these sorts of applications, a set of representative buildings are typically simulated to predict performance of the entire population of buildings. Focusing on the U.S. single-family residential building stock, this paper will describe how multiple data sources for building characteristics are combined into a highly-granular database that preserves the important interdependencies of the characteristics. We will present the sampling technique used to generate a representative set of thousands (up to hundreds of thousands) of building models. We will also present results of detailed calibrations against building stock consumption data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A High-Granularity Approach to Modeling Energy Consumption and Savings Potential in the U.S. Residential Building Stock: Preprint

Building simulations are increasingly used in various applications related to energy efficient buildings. For individual buildings, applications include: design of new buildings, prediction of retrofit savings, ratings, performance path code compliance and qualification for incentives. Beyond individual building applications, larger scale applications (across the stock of buildings at various scales: national, regional and state) include: codes and standards development, utility program design, regional/state planning, and technology assessments. For these sorts of applications, a set of representative buildings are typically simulated to predict performance of the entire population of buildings. Focusing on the U.S. single-family residential building stock, this paper will describe how multiple data sources for building characteristics are combined into a highly-granular database that preserves the important interdependencies of the characteristics. We will present the sampling technique used to generate a representative set of thousands (up to hundreds of thousands) of building models. We will also present results of detailed calibrations against building stock consumption data.

building stock↗

Development of a Roof Savings Calculator

A web-based Roof Savings Calculator (RSC) has been deployed for the Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs the latest web technologies and usability design to provide an easy input interface to an annual simulation of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim. Building defaults were assigned and can provide annual energy and cost savings after the user selects nothing more than building location. In addition to cool reflective roofs, the RSC tool can simulate multiple roof types at arbitrary inclinations. There are options for above sheathing ventilation, radiant barriers and low-emittance surfaces. The tool also accommodates HVAC ducts either in the conditioned space or in the attic with custom air leakage rates. Multiple layers of thermal mass, ceiling insulation and other parameters can be compared side-by-side to generate energy/cost savings between two buildings. The RSC tool was benchmarked against field data for demonstration homes in Ft Irwin, CA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermally Anisotropic Composites for Improving the Energy Efficiency of Building Envelopes

This article describes a novel application of thermal anisotropy for improving the energy efficiency of building envelopes. The current work was inspired by existing research on improved heat dissipation in electronics using thermal anisotropy. Past work has shown that thermally anisotropic composites (TACs) can be created by the alternate layering of two dissimilar, isotropic materials. Here, a TAC consisting of alternate layers of rigid foam insulation and thin, high-conductivity aluminum foil was investigated. The TAC was coupled with copper tubes with circulating water that acted as a heat sink and source. The TAC system was applied to a conventional wood-framed wall assembly, and the energy benefits were investigated experimentally and numerically. For experimental testing, large scale test wall specimens were built with and without the TAC system and tested in an environmental chamber under simulated diurnal hot and cold weather conditions. Component-level and whole building numerical simulations were performed to investigate the energy benefits of applying the TAC system to the external walls of a typical, single-family residential building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of DOE's Roof Savings Calculator with Comparison to other Simulation Engines

A web-based Roof Savings Calculator (RSC) has been deployed for the Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs the latest web technologies and usability design to provide an easy input interface to an annual simulation of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim. Building defaults were assigned based on national averages and can provide estimated annual energy and cost savings after the user selects nothing more than building location. In addition to cool reflective roofs, the RSC tool can simulate multiple roof and attic configurations including different roof slopes, above sheathing ventilation, radiant barriers, low-emittance surfaces, HVAC duct location, duct leakage rates, multiple layers of building materials, ceiling and deck insulation levels, and other parameters. A base case and energy-efficient alternative can be compared side-by-side to generate an energy/cost savings estimate between two buildings. The RSC tool was benchmarked against field data for demonstration homes in Ft. Irwin, CA. However, RSC gives different energy savings estimates than previous cool roof simulation tools so more thorough software and empirical validation proved necessary. This report consolidates much of the preliminary analysis for comparison of RSC s projected energy savings to that from other simulation engines.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TASK 2.5.4 DEVELOPMENT OF AN ENERGY SAVINGS CALCULATOR

California s major energy utilities and the California Energy Commission (CEC) are seeking to allocate capital that yields the greatest return on investment for energy infrastructure that meets any part of the need for reliable supplies of energy. The utilities are keenly interested in knowing the amount of electrical energy savings that would occur if cool roof color materials are adopted in the building market. To meet this need the Oak Ridge National Laboratory and the Lawrence Berkeley National Laboratory (LBNL) have been collaborating on a Public Interest Energy Research (PIER) project to develop an industry-consensus energy-savings calculator. The task was coordinated with an ongoing effort supported by the DOE to develop one calculator to achieve both the DOE and the EPA objectives for deployment of cool roof products. Recent emphasis on domestic building energy use has made the work a top priority by the Department of Energy s (DOE) Building Technologies Program. The Roof Savings Calculator (RSC) tool is designed to help building owners, manufacturers, distributors, contractors and practitioners easily run complex simulations. The latest web technologies and usability design were employed to provide an easy input interface to an annual simulation of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim. Building defaults were assigned based on the best available statistical evidence and can provide energy and cost savings after the user selects nothing more than the building location. A key goal for the tool is to promote the energy benefits of cool color tile, metal and asphalt shingle roof products and other energy saving systems. The RSC tool focuses on applications for the roof and attic; however, the code conducts a whole building simulation that puts the energy and heat flows of the roof and attic into the perspective of the whole house. An annual simulation runs in about 30 sec. In addition to cool reflective roofs, the RSC tool will simulate high- medium- and low-slope roofs, and has a custom selection for the user whose house has a unique inclination. There is an option for above sheathing ventilation, which is prevalent in tile and stone-coated metal roof assemblies. The tool also accommodates the effects of radiant barriers and low-emittance surfaces in the inclined air space above the sheathing. The practitioner can select to have air-conditioning ducts either in the conditioned space or in the attic. If in the attic, the user can select one of three air leakage options. Option 1 is an inspected duct having 4% leakage and code level of duct insulation; option 2 is a poorly insulated duct having 14% air leakage; and option 3 is a custom leakage rate specified by the user. The practitioner can setup multiple layers of ceiling insulation. AtticSim is benchmarked against the field data acquired for Ft. Irwin located near Barstow, CA, first as a standalone simulation program and then again integrated within the DOE-2.1E program. The standalone benchmark was very useful to determining how well AtticSim replicates the building physics of an attic. The coupled benchmark was useful to verify that the DOE-2.1E/AtticSim code is modeling correctly the dynamic relationship between the attic and the occupied space below, as well as the interactions between the attic and the HVAC system, in particular when the ducts are located in the attic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Roof Savings Calculator

A web-based Roof Savings Calculator (RSC) has been deployed for the Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs the latest web technologies and usability design to provide an easy input interface to an annual simulation of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim. Building defaults were assigned and can provide estimated annual energy and cost savings after the user selects nothing more than building location. In addition to cool reflective roofs, the RSC tool can simulate multiple roof types at arbitrary inclinations. There are options for above sheathing ventilation, radiant barriers, and low-emittance surfaces. The tool also accommodates HVAC ducts either in the conditioned space or in the attic with custom air leakage rates. Multiple layers of building materials, ceiling and deck insulation, and other parameters can be compared side-by-side to generate an energy/cost savings estimate between two buildings. The RSC tool was benchmarked against field data for demonstration homes in Ft. Irwin, CA.

DOE cool roof calculator↗

Scout: An Impact Analysis Tool for Building Energy-Efficiency Technologies

Evaluating the national impacts of candidate U.S. building energy-efficiency technologies has historically been difficult for organizations with large energy efficiency portfolios. In particular, normalizing results from technology-specific impact studies is time-consuming when those studies do not use comparable assumptions about the underlying building stock. To equitably evaluate its technology research, development, and deployment portfolio, the U.S. Department of Energy's Building Technologies Office has developed Scout, a software tool that quantitatively assesses the energy and CO2 impacts of building energy-efficiency measures on the national building stock. Scout efficiency measures improve upon the unit performance and/or lifetime operational costs of an equipment stock baseline that is determined from the U.S. Energy Information Administration Annual Energy Outlook (AEO). Scout measures are characterized by a market entry and exit year, unit performance level, cost, and lifetime. To evaluate measures on a consistent basis, Scout uses EnergyPlus simulation on prototype building models to translate measure performance specifications to whole-building energy savings; these savings impacts are then extended to a national scale using floor area weighting factors. Scout represents evolution in the building stock over time using AEO projections for new construction, retrofit, and equipment replacements, and competes technologies within market segments under multiple adoption scenarios. Scout and its efficiency measures are open-source, as is the EnergyPlus whole building simulation framework that is used to evaluate measure performance. The program is currently under active development and will be formally released once an initial set of measures has been analyzed and reviewed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗