Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry

Purpose: A surface electronic brachytherapy (EBT) device is in fact an x-ray source collimated with specific applicators. Low-energy (<100 kVp) x-ray beam dosimetry faces several challenges that need to be addressed. A number of calibration protocols have been published for x-ray beam dosimetry. The media in which measurements are performed are the fundamental difference between them. The aim of this study was to evaluate the surface dose rate of a low-energy x-ray source with small field applicators using different calibration standards and different small-volume ionization chambers, comparing the values and uncertainties of each methodology. Methods: The surface dose rate of the EBT unit Esteya (Elekta Brachytherapy, The Netherlands), a 69.5 kVp x-ray source with applicators of 10, 15, 20, 25, and 30 mm diameter, was evaluated using the AAPM TG-61 (based on air kerma) and International Atomic Energy Agency (IAEA) TRS-398 (based on absorbed dose to water) dosimetry protocols for low-energy photon beams. A plane parallel T34013 ionization chamber (PTW Freiburg, Germany) calibrated in terms of both absorbed dose to water and air kerma was used to compare the two dosimetry protocols. Another PTW chamber of the same model was used to evaluate the reproducibility between these chambers. Measurements were also performed with two different Exradin A20 (Standard Imaging, Inc., Middleton, WI) chambers calibrated in terms of air kerma. Results: Differences between surface dose rates measured in air and in water using the T34013 chamber range from 1.6% to 3.3%. No field size dependence has been observed. Differences are below 3.7% when measurements with the A20 and the T34013 chambers calibrated in air are compared. Estimated uncertainty (with coverage factor k = 1) for the T34013 chamber calibrated in water is 2.2%–2.4%, whereas it increases to 2.5% and 2.7% for the A20 and T34013 chambers calibrated in air, respectively. The output factors, measured with the PTW chambers, differ by less than 1.1% for any applicator size when compared to the output factors that were measured with the A20 chamber. Conclusions: Measurements using both dosimetric protocols are consistent, once the overall uncertainties are considered. There is also consistency between measurements performed with both chambers calibrated in air. Both the T34013 and A20 chambers have negligible stem effect. Any x-ray surface brachytherapy system, including Esteya, can be characterized using either one of these calibration protocols and ionization chambers. Having less correction factors, lower uncertainty, and based on measurements, performed in closer to clinical conditions, the TRS-398 protocol seems to be the preferred option.

60 APPLIED LIFE SCIENCES↗

Specification of EBR-II Contact Profilometry Data

All contact profilometry data stored in FIPD was originally measured using the HFEF vertical contact profilometer, which was an electronic gauge to measure the diameter profile of an element or capsule continuously over the region of interest. The element could be rotated as it passed through the probes if the wire wrap was not to be removed and the element could be returned to reactor for further irradiation. If the wire wrap was removed, the element could be drawn vertically through the probes, rotated, and the process repeated. In this way any cladding ovality could be observed. Figure 1 shows the setup used to measure the fuel pin diameter profile. The ambient temperature during the measurement was ~21-23 ºC. The cladding temperature during the measurement is considered to be similar to the ambient temperature by assuming the fuel decay heat did not impact the cladding temperature. Two documents contain most of the important details about contact profilometry measurements. The first one is the operational manual of the contact profilometer (title: Element contact profilometer operation and maintenance, HFEF/N OMM 4326, DOC. NO. W0202-0007-SA-01). This manual provides: (1) description of the contact profilometer including the functions of each component (support stage, sensing head, control system, and calibration standards, etc.); (2) step-by-step guidance on calibrations, operations, and measurements; and (3) maintenance procedures and other details of the contact profilometer. The second document is a publicly accessible report entitled “A Fuel-element Profilometer for the HFEF.” This report describes the development of the contact profilometer, including the design requirements, features, and details of each component, as well as the acceptance tests for the built system. This document is important because it reports the uncertainties of the measurements with detailed deduction procedures. The reported uncertainties should apply to all hard-copy contact profilometry data in FIPD. Some key information about contact profilometry measurements was extracted from these two documents. Combining the information with other sources, a specification for interpretating the contact profilometry data in FIPD was established.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mass spectrometry in the stratosphere

A gas expansion system incorporating a mass spectrometer that has been successfully flown in the stratosphere is described. Neutral gas particles are formed into a molecular beam that traverses the ion source of the mass spectrometer without wall interactions. It is noted that vertical profiles of such constituents as H2O, CO2, and O3 have been measured in the altitude range of 20 to 40 km during balloon descents. Isotopes of important gases (N2, O2, Ar) provided in-flight calibration standards. Before each flight the mass spectrometer system is calibrated in the laboratory for many gases of interest, including ozone. Mixing ratios of ozone established from recent flights have accuracies of better than 5 percent. The sensitivity of the system is sufficient to detect as well the heavy isotope of ozone at mass 50. A noticeable enhancement of heavy ozone in the upper stratosphere has been found. The mass spectrometer system is seen as providing a unique opportunity to perform in situ measurements in the stratosphere in combination with isotopic studies.

Mauersberger, K.↗

The Thermal Structure and Composition of Jupiter's Great Red Spot From JWST/MIRI

Jupiter's Great Red Spot (GRS) was mapped by the James Webb Space Telescope (JWST)/Mid-Infrared Instrument (4.9–27.9 μm) in July and August 2022. These observations took place alongside a suite of visual and infrared observations from; Hubble, JWST/NIRCam, Very Large Telescope/VISIR and amateur observers which provided both spatial and temporal context across the jovian disc. The stratospheric temperature structure retrieved using the NEMESIS software revealed a series of hot-spots above the GRS. These could be the consequence of GRS-induced wave activity. In the troposphere, the temperature structure was used to derive the thermal wind structure of the GRS vortex. These winds were only consistent with the independently determined wind field by JWST/NIRCam at 240 mbar if the altitude of the Hubble-derived winds were located around 1,200 mbar, considerably deeper than previously assumed. No enhancement in ammonia was found within the GRS but a link between elevated aerosol and phosphine abundances was observed within this region. North-south asymmetries were observed in the retrieved temperature, ammonia, phosphine and aerosol structure, consistent with the GRS tilting in the north-south direction. Finally, a small storm was captured north-west of the GRS that displayed a considerable excess in retrieved phosphine abundance, suggestive of vigorous convection. Despite this, no ammonia ice was detected in this region. The novelty of JWST required us to develop custom-made software to resolve challenges in calibration of the data. This involved the derivation of the “FLT-5” wavelength calibration solution that has subsequently been integrated into the standard calibration pipeline.

Jake Harkett↗

Blackbody cavity radiometer has rapid response

Fast response, spectrally linear standard detector in the form of a blackbody cavity radiometer calibrates rapidly responding photodetectors against a calibrated standard detector. A power amplifier with maximum available gain reduces error signal without stability loss. It may be used as a blackbody radiator by manipulation of the bridge variable arm.

Haley, F. C.↗

Measurements by a Vector Network Analyzer at 325 to 508 GHz

Recent experiments were performed in which return loss and insertion loss of waveguide test assemblies in the frequency range from 325 to 508 GHz were measured by use of a swept-frequency two-port vector network analyzer (VNA) test set. The experiments were part of a continuing effort to develop means of characterizing passive and active electronic components and systems operating at ever increasing frequencies. The waveguide test assemblies comprised WR-2.2 end sections collinear with WR-3.3 middle sections. The test set, assembled from commercially available components, included a 50-GHz VNA scattering- parameter test set and external signal synthesizers, augmented with recently developed frequency extenders, and further augmented with attenuators and amplifiers as needed to adjust radiofrequency and intermediate-frequency power levels between the aforementioned components. The tests included line-reflect-line calibration procedures, using WR-2.2 waveguide shims as the "line" standards and waveguide flange short circuits as the "reflect" standards. Calibrated dynamic ranges somewhat greater than about 20 dB for return loss and 35 dB for insertion loss were achieved. The measurement data of the test assemblies were found to substantially agree with results of computational simulations.

Fung, King Man↗

Atmospheric H 2 observations from the NOAA Cooperative Global Air Sampling Network

Abstract. The NOAA Global Monitoring Laboratory (GML) measures atmospheric hydrogen (H2) in grab samples collected weekly as flask pairs at over 50 sites in the Cooperative Global Air Sampling Network. Measurements representative of background air sampling show higher H2 in recent years at all latitudes. The marine boundary layer (MBL) global mean H2 was 552.8 ppb in 2021, 20.2 ± 0.2 ppb higher compared to 2010. A 10 ppb or more increase over the 2010–2021 average annual cycle was detected in 2016 for MBL zonal means in the tropics and in the Southern Hemisphere. Carbon monoxide measurements in the same-air samples suggest large biomass burning events in different regions likely contributed to the observed interannual variability at different latitudes. The NOAA H2 measurements from 2009 to 2021 are now based on the World Meteorological Organization Global Atmospheric Watch (WMO GAW) H2 mole fraction calibration scale, developed and maintained by the Max Planck Institute for Biogeochemistry (MPI-BGC), Jena, Germany. GML maintains eight H2 primary calibration standards to propagate the WMO scale. These are gravimetric hydrogen-in-air mixtures in electropolished stainless steel cylinders (Essex Industries, St. Louis, MO), which are stable for H2. These mixtures were calibrated at the MPI-BGC, the WMO Central Calibration Laboratory (CCL) for H2, in late 2020 and span the range 250–700 ppb. We have used the CCL assignments to propagate the WMO H2 calibration scale to NOAA air measurements performed using gas chromatography and helium pulse discharge detector instruments since 2009. To propagate the scale, NOAA uses a hierarchy of secondary and tertiary standards, which consist of high-pressure whole-air mixtures in aluminum cylinders, calibrated against the primary and secondary standards, respectively. Hydrogen at the parts per billion level has a tendency to increase in aluminum cylinders over time. We fit the calibration histories of these standards with zero-, first-, or second-order polynomial functions of time and use the time-dependent mole fraction assignments on the WMO scale to reprocess all tank air and flask air H2 measurement records. The robustness of the scale propagation over multiple years is evaluated with the regular analysis of target air cylinders and with long-term same-air measurement comparison efforts with WMO GAW partner laboratories. Long-term calibrated, globally distributed, and freely accessible measurements of H2 and other gases and isotopes continue to be essential to track and interpret regional and global changes in the atmosphere composition. The adoption of the WMO H2 calibration scale and subsequent reprocessing of NOAA atmospheric data constitute a significant improvement in the NOAA H2 measurement records.

Pétron, Gabrielle↗

(abstract) Absolute Flux Calibrations of Venus and Jupiter at 32 GHz

The microwave flux densities of Venus and Jupiter at 32 GHz have been measured using a calibration standard radio telescope system at the Owens Valley Radio Observatory (OVRO) during April and May of 1993. These measurements are part of a joint JPL/Caltech program to accurately calibrate a catalog of other radio sources using the two bright planets as flux standards.

microwave flux densities Venus Jupiter catalog cal↗

Automated Test Systems for Toxic Vapor Detectors

The NASA Toxic Vapor Detection Laboratory (TVDL) at the Kennedy Space Center (KSC), Florida, has been using Personal Computer based Data Acquisition and Control Systems (PCDAS) for about nine years. These systems control the generation of toxic vapors of known concentrations under controlled conditions of temperature and humidity. The PCDAS also logs the test conditions and the test article responses in data files for analysis by standard spreadsheets or custom programs. The PCDAS was originally developed to perform standardized qualification and acceptance tests in a search for a commercial off-the-shelf (COTS) toxic vapor detector to replace the hydrazine detectors for the Space Shuttle launch pad. It has since become standard test equipment for the TVDL and is indispensable in producing calibration standards for the new hydrazine monitors at the 10 part per billion (ppb) level. The standard TVDL PCDAS can control two toxic vapor generators (TVG's) with three channels each and two flow/temperature/humidity (FIFH) controllers and it can record data from up to six toxic vapor detectors (TVD's) under test and can deliver flows from 5 to 50 liters per minute (L/m) at temperatures from near zero to 50 degrees Celsius (C) using an environmental chamber to maintain the sample temperature. The concentration range for toxic vapors depends on the permeation source installed in the TVG. The PCDAS can provide closed loop control of temperature and humidity to two sample vessels, typically one for zero gas and one for the standard gas. This is required at very low toxic vapor concentrations to minimize the time required to passivate the sample delivery system. Recently, there have been several requests for information about the PCDAS by other laboratories with similar needs, both on and off KSC. The purpose of this paper is to inform the toxic vapor detection community of the current status and planned upgrades to the automated testing of toxic vapor detectors at the Kennedy Space Center.

Mattson, C. B.↗

Automated Test Systems for Toxic Vapor Detectors

The NASA Toxic Vapor Detection Laboratory (TVDL) at the Kennedy Space Center (KSC), Florida, has been using Personal Computer based Data Acquisition and Control Systems (PCDAS) for about nine years. These systems control the generation of toxic vapors of known concentrations under controlled conditions of temperature and humidity. The PCDAS also logs the test conditions and the test article responses in data files for analysis by standard spreadsheets or custom programs. The PCDAS was originally developed to perform standardized qualification and acceptance tests in a search for a commercial off-the-shelf (COTS) toxic vapor detector to replace the hydrazine detectors for the Space Shuttle launch pad. It has since become standard test equipment for the TVDL and is indispensable in producing calibration standards for the new hydrazine monitors at the 10 part per billion (ppb) level. The standard TVDL PCDAS can control two toxic vapor generators (TVG's) with three channels each and two flow/ temperature / humidity (FTH) controllers and it can record data from up to six toxic vapor detectors (TVD's) under test and can deliver flows from 5 to 50 liters per minute (L/m) at temperatures from near zero to 50 degrees Celsius (C) using an environmental chamber to maintain the sample temperature. The concentration range for toxic vapors depends on the permeation source installed in the TVG. The PCDAS can provide closed loop control of temperature and humidity to two sample vessels, typically one for zero gas and one for the standard gas. This is required at very low toxic vapor concentrations to minimize the time required to passivate the sample delivery system. Recently, there have been several requests for information about the PCDAS by other laboratories with similar needs, both on and off KSC. The purpose of this paper is to inform the toxic vapor detection community of the current status and planned upgrades to the automated testing of toxic vapor detectors at the Kennedy Space Center.

Mattson, C. B.↗

Fiber Optic Experience with the Smart Actuation System on the F-18 Systems Research Aircraft

High bandwidth, immunity to electromagnetic interference, and potential weight savings have led to the development of fiber optic technology for future aerospace vehicle systems. This technology has been incorporated in a new smart actuator as the primary communication interface. The use of fiber optics simplified system integration and significantly reduced wire count. Flight test results showed that fiber optics could be used in aircraft systems and identified critical areas of development of fly-by-light technology. This paper documents the fiber optic experience gained as a result of this program, and identifies general design considerations that could be used in a variety of specific applications of fiber optic technology. Environmental sensitivities of fiber optic system components that significantly contribute to optical power variation are discussed. Although a calibration procedure successfully minimized the effect of fiber optic sensitivities, more standardized calibration methods are needed to ensure system operation and reliability in future aerospace vehicle systems.

Zavala, Eddie↗

Total metals, sulfur and organic carbon data; Slate River floodplain, Crested Butte, CO; March 2021-October 2021

This data package includes processed and undiluted measurements for metal, sulfur and organic carbon concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between March and October of 2021. These measurements were all recorded at the Environmental Measurements Facility (EM-1) at Stanford University in Stanford, CA. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 2C until measured at EM-1.Analysis by ICP-MS:Measurements for total metals were performed on an inductively coupled plasma optical emission spectrometer (ICP-OES; iCAP 6300, Thermo Scientific, Cambridge, U.K.). Calibration standards were prepared from the mulit element stock solution (Sigma-Aldrich Multielement standard for ICP, St. Louis, MO) using matrix matched to sample solutions (2% HNO3). Calibration curves included 5 points with correlation coefficients of >0.99. The QC protocol includes a continuing calibration blank and quality control samples that are analyzed just after calibration and again every 20 samples and at the completion of the run. Acceptable QC responses must be between 90-110% of the certified value. Analysis by Total Organic Carbon:Dissolved organic carbon concentrations were quantified on a total organic carbon (TOC) analyzer (TOC-L, Shimadzu, Kyoto, Japan) running the NPOC method. Standard curves were developed using an Organic Carbon Standard from RICCA Chemical Company (Arlington,TX). A series of 4 to 6 standards were automatically diluted by the instrument in a concentration range that spans that of the samples. A blank sample was run just after the calibration curve and at the end of the run. A QC sample was run every 25 samples. Acceptable QC responses must be between 90-110% of the certified value.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Data and Scripts associated with: “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy”

This data package is associated with the publication “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?” submitted to PLOS ONE and accepted for publication (Fulton, S.G. et al. 2023; doi not yet available).Variation in electrical conductivity (EC) of water is important to reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. This data package supports a study addressing the need for a robust performance assessment of open source (OS) EC sensors. We evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. This data package presents the results from the different testing laboratory configurations. It also includes an R script for statistical analysis of the data and an Arduino IDE file used to calibrate and collect data with the OS Atlas EC sensor. File types are .csv, .pdf, .R, and .ino.

54 ENVIRONMENTAL SCIENCES↗

Low-resolution ultraviolet spectroscopy of several hot stars observed from Apollo 17

Low-resolution ultraviolet spectra were obtained for six early-type stars in 1972 December, using an Ebert spectrometer mounted in the service module of the Apollo 17 spacecraft. The spectrometer scanned from 1180 A to 1680 A, with a speed that varied with wavelength according to a program chosen for lunar studies. Spectral resolution was 11 A. The ultraviolet absolute calibration of the instrument was determined by comparison with National Bureau of Standards calibrated photodiodes, and is believed known to plus or minus 10 percent. The absolute intensities are in good general agreement with the observations of other stars and with the predictions of stellar model-atmosphere calculations.

Henry, R. C.↗

Radiometric calibrations of portable sources in the vacuum ultraviolet

The primary UV radiometric calibration standards of the Atomic and Plasma Radiation Division of the NBS are the hydrogen arc and the blackbody line arc. The secondary standards are the argon mini- and maxiarcs, and the deuterium arc lamp. Calibration methods involving both spectral radiance and irradiance, as well as the evaluation of their uncertainties, are discussed. Attention is given to the establishment of an irradiance scale, and the absolute spectral irradiance, measured as a function of wavelength, at a 50-cm distance from the field aperture for five different continuum sources.

Klose, Jules Z.↗

Calibrating the SPECTACULAR constitutive model using legacy Sandia data for two filled epoxy systems: 828/CTBN/DEA/GMB and 828/DEA/GMB

The SPECTACULAR model is a development extension of the Simplified Potential Energy Clock (SPEC) model. Both models are nonlinear viscoelastic constitutive models used to predict a wide range of time-dependent behaviors in epoxies and other glass-forming materials. This report documents the procedures used to generate SPECTACULAR calibrations for two particulate-filled epoxy systems, 828/CTBN/DEA/GMB and 828/DEA/GMB. No previous SPECTACULAR or SPEC calibration exists for 828/CTBN/DEA/GMB, while a legacy SPEC calibration exists for 828/DEA/GMB. To generate the SPECTACULAR calibrations, a step-by-step procedure was executed to determine parameters in groups with minimal coupling between parameter groups. This procedure has often been deployed to calibrate SPEC, therefore the resulting SPECTACULAR calibration is backwards compatible with SPEC (i.e. none of the extensions specific to SPECTACULAR are used). The calibration procedure used legacy Sandia experimental data stored on the Polymer Properties Database website. The experiments used for calibration included shear master curves, isofrequency temperature sweeps under oscillatory shear, the bulk modulus at room temperature, the thermal strain during a temperature sweep, and compression through yield at multiple temperatures below the glass transition temperature. Overall, the calibrated models fit the experimental data remarkably well. However, the glassy shear modulus varies depending on the experiment used to calibrate it. For instance, the shear master curve, isofrequency temperature sweep under oscillatory shear, and the Young's modulus in glassy compression yield values for the glassy shear modulus at the reference temperature that vary by as much as 15 %. Also, for 828/CTBN/DEA/GMB, the temperature dependence of the glassy shear modulus when fit to the Young's modulus at different temperatures is approximately four times larger than when it is determined from the isofrequency temperature sweep under oscillatory shear. For 828/DEA/GMB, the temperature dependence of the shear modulus determined from the isofrequency temperature sweep under oscillatory shear accurately predicts the Young's modulus at different temperatures. When choosing values for the shear modulus, fitting the glassy compression data was prioritized. The new and legacy calibrations for 828/DEA/GMB are similar and appear to have been calibrated from the same data. However, the new calibration improves the fit to the thermal strain data. In addition to the standard calibrations, development calibrations were produced that take advantage of development features of SPECTACULAR , including an updated equilibrium Helmholtz free energy that eliminates undesirable behavior found in previous work. In addition to the previously mentioned experimental data, the development calibrations require data for the heat capacity during a stress-free temperature sweep to calibrate thermal terms.

36 MATERIALS SCIENCE↗

High-Temperature Characterization of Alumina Substrates and Folded Slot Antenna

The characterization of 99.6% polycrystalline alumina substrates and folded slot antennas is presented in this paper. Coplanar Waveguide (CPW) calibration standards where fabricated on 99.6% polycrystalline alumina substrates. Thru-Reflect-Line (TRL) calibrations were performed at temperatures of 25 to 400 C over a frequency range from 0.5 to 50 GHz. The effective dielectric constant of the alumina substrates was determined to be relatively constant at 5.4 from 25 to 200 C and then increased steadily to approximately 6 at 400 C. The loss of the CPW lines increased as temperature and frequency increased as well noting that the increase in loss is even more profound as both the temperature and frequency increased simultaneously. A CPW fed folded slot antenna fabricated on the alumina substrates is also presented. The Return Loss (RL) of a CPW fed folded slot antenna exhibits a self impedance matching technique. The RL of the folded slot antenna at 25 C displays a resonance at 3.5 GHz and is approximately 16 dB in magnitude. At 300 C the resonance shifts down in frequency to approximately 3.3 dB and has roughly the same magnitude. However the loss of the antenna response also increases at this elevated temperature. This work is part of the initial stages of an effort at NASA Glenn research Center to develop wireless sensors for harsh environments. This work can reduce cost, space to house all the hard wired connections, and reduce the weight of the overall units such as aerospace engines and allow for the placement of the wireless sensors in the engine which are not possible with hard wired sensors.

Scardelletti, Maximilian C.↗

ANALYTICAL LABORATORY AT IDAHO NATIONAL LABORATORY COUNTING EQUIPMENT STANDARDIZATION AND QUALITY CONTROL IMPROVEMENT

The Analytical Laboratory at Idaho National Laboratory (INL) is a growing program with an emphasis on providing high quality results to customers, and an increasing focus on independent research. The Analytical Laboratory Counting Group has a number of capabilities: six gamma-ray counters, one gamma-ray sample changer, four gas flow proportional counter drawers, an auto-changing gas flow proportional counter, two liquid scintillation counters, and an alpha spectroscopy system. Other capabilities within the Analytical Laboratory include quadrupole inductively coupled plasma mass spectrometry (ICP-MS), high resolution ICP-MS, multi-collector ICP-MS, ICP atomic emission spectrometry (ICP-AES), gas mass spectrometry, thermal ionization mass spectrometry (TIMS), several glove boxes and fume hoods for sample preparation, and six interconnected hot cells for sample receipt and dissolution. In order to position the Analytical Laboratory as a world-class research institution, the Counting Group has recently begun making improvements to its analytical techniques, calibrations, standardization, and quality control procedures. A large part of this effort is to increase the level of documentation of instrument work. One project is to re-calibrate all of the gamma systems with newly purchased standards. One of the changes made in the purchase of the new standards was to lower the total activity so that the dead time of the calibration would more closely match the dead time of typical samples. Similarly, another planned project is to use new standards to re-calibration the gas flow proportional counters. Additional work has focused on testing and improving alpha spectroscopy sample preparation techniques. Plutonium separations have been tested to improve tracer recovery and to verify the separation technique in the presence of typical sample matrices. A final planned area of improvements has focused on liquid scintillation counting. One difficulty the Counting Group has encountered in liquid scintillation counting is an inflated gross alpha count relative to other analysis methods in the presence of high gross beta activity. Ideas include investigating the impact of choice of scintillation cocktail, as well as the effects of sample dilution.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗