Search NASA⌕ Search

SEARCH · Search NASA

Results for “CFRP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Joining of Thermoset Carbon Fiber Reinforced Polymer and AZ31 Magnesium Alloy Sheet Via Friction Stir Interlocking

A new technique called friction stir interlocking (FSI) was applied for lap-joining of AZ31 magnesium sheet and thermoset carbon fiber reinforced polymer (TS-CFRP) sheet. Instead of directly joining AZ31 and TS-CFRP, a series of magnesium interlocks were used to friction stir weld with AZ31 sheet to enable joining with TS-CFRP. Microstructural characterization of joint cross sections showed that a tool rotation rate of 800 rpm produced incomplete mixing of magnesium interlocks and the top AZ31 sheet, while 1200 rpm achieved sufficient material mixing to avoid unwelded regions. Mechanical property characterization showed that AZ31/TS-CFRP dissimilar joints failed through the magnesium interlock shanks during lap shear tensile testing, with a maximum normalized joint strength reaching ~100 MPa.

Wang, Tianhao↗

Metallization of Carbon Fiber Reinforced Polymers for Lightning Strike Protection

Carbon fiber reinforced polymers (CFRPs) are increasingly used in the latest generations of aircraft, but their low electrical conductivity is a concern for lightning strike protection. During the past few years, development of lightning strike protection solutions for CFRP has attracted increasing interest, and cold spray is one coating approach to achieving this. In this work, pure tin coatings and tin–copper composite coatings were cold sprayed on CFRP as possible lightning strike protection materials. The coatings were subjected to various mechanical and electrical characterizations. The effect of annealing on electrical conductivity was also examined. Furthermore, continuous current injection tests, which duplicated component C of a lightning waveform, were performed on the coatings. The results showed that the cold-sprayed coatings can provide effective protection to the CFRP underneath when subjected to currents up to 200 A with 1-s duration.

36 MATERIALS SCIENCE↗

Significant slowdown of plasma-optimized surface energy deactivation by vacuum sealing for efficient adhesive bonding

This work proposes an approach to minimize surface energy deactivation of plasma-treated metal and carbon fiber-reinforced polymer (CFRP) surfaces by vacuum sealing. Plasma treatments enhance adhesive wettability on post-treated surfaces for adhesive joints, but the treated surfaces deactivate quickly in air. The surface energy of aluminum alloy AA6061 and carbon fiber-reinforced polymer-polyamide (CFRP-PA66) optimally treated by a blown air plasma instrument returns to the original surface energy within one hour. Vacuum sealing of AA6061 and CFRP-PA66 reduced the surface energy deactivation over 7 days by at least 230 times and 970 times compared to in air. Double Cantilever Beam (DCB) tests performed on adhesively-bonded AA6061/CFRP-PA66 joints showed that the total energy release and energy dissipation before failure of plasma-treated and vacuum-sealed materials was up to 60% more than plasma-treated materials without vacuum sealing and up to 125% more than non-plasma-treated materials.

42 ENGINEERING↗

Failure criteria of unidirectional carbon fiber reinforced polymer composites informed by a computational micromechanics model

Failure prediction for carbon fiber reinforced polymer (CFRP) composites has been a longstanding challenge. In this paper, we address this challenge by first applying a well-established computational micromechanics model based on representative volume element to predict the failure envelopes of unidirectional (UD) CFRP composites. Then, these failure envelopes are compared with the classical failure criteria. We have evaluated the performances of these failure criteria and identified the aspects for further improvement in their accuracies for the UD CFRP composites studied herein. Based on the failure mechanisms from computational analyses and the comparisons between predicted failure envelopes and classical failure criteria, a new set of homogenized failure criteria is proposed. Additionally, the newly proposed failure criteria show significant improvement according to our computational and experimental results. Furthermore, we have compared the proposed failure criteria with existing experimental data and computational results available in the literature for different types of composites. Good agreements are generally observed.

36 MATERIALS SCIENCE↗

Thickness threshold study of polyaniline-based lightning strike protection coating for carbon/glass fiber reinforced polymer composites

Different polyaniline (PANI) based lightning strike protection (LSP) coating thicknesses were tested against simulated lightning strike tests to evaluate the threshold thickness of the coating. A series of lightning strike tests were performed on carbon/glass fiber reinforced polymer (CFRP/GFRP) composites subjected to simulated lightning currents ranging from 40 to 100 kA. Five LSP-coated specimens were considered herein: two CFRP and three GFRP composites. A minimum of ~ 345 μm thick PANI-based LSP coating on CFRP and GFRP composites under a 40 kA peak current retained 83 % and 100 % residual strength, respectively. Additionally, GFRP specimens tested against 60 and 100 kA peak currents exhibited 100 % residual strength. Finally, this study proposes that a PANI-based LSP coating is suitable for protecting GFRP composites, while the careful design is necessary for CFRP composites to avoid any catastrophic failure.

36 MATERIALS SCIENCE↗

Effect of printing parameters on 3D-printed carbon fiber-reinforced polymer composites under magnetic field control

Magnetic field controlled (MFC) 3D printing is a promising method for realizing the intelligent control of the structural performance of carbon fiber-reinforced plastic (CFRP) composites by adjusting the fiber orientation during the printing process. However, few studies have focused on the influence of the printing parameters on the magnetic control of the fiber direction. Therefore, in this study, the mechanical properties and internal fiber distributions of MFC 3D-printed samples of CFRP composites with 10 wt% fiber content, which were printed at different speeds and layer thicknesses, were investigated. Subsequently, the effects of the fiber content on the mechanical properties and fiber distribution of the MFC 3D-printed samples were studied. Furthermore, the origin of fiber fracture was evaluated through observation and analysis of the fracture section using scanning electron microscopy. The fiber orientation could be well adjusted under the action of a magnetic field and adjustment of printing parameters, thereby improving the tensile strength, young's modulus significantly with slightly decrease of fracture elongation. The recommended parameter combinations (printing speed and layer thickness) were 40 mm/s and 0.2 mm for 10 wt% fiber content CFRP composites.

36 MATERIALS SCIENCE↗

Deformation and Fracture Behaviors of Cylindrical Battery Shell During Thermal Runaway

Thermal runaway is one of the catastrophic failure modes of lithium-ion cells. During thermal runaway in cylindrical cells, sidewall shell rupture has been identified as a contributing factor for thermal runaway propagation in battery packs. Herein, the deformation and fracture behaviors of the battery shell during thermal runaway are investigated based on in-situ and ex-situ characterization as well as physics-based modeling. The deformation and fracture modes of the battery shell with/without Carbon Fiber Reinforced Polymer (CFRP) sleeves are identified. In the simulation, the strain introduced by thermal expansion of the system is considered, as well as the thermal and strain rate effects on the plastic stage. The final cell shell modeling is validated by cell thermal runaway tests. Results reveal the quantitative relation between shell deformation behaviors and the pressure and temperature distribution. Both the experiment and model demonstrate the effectiveness of adding a tight-fitting CFRP sleeve around the cell in limiting the side-wall rupture of the shell. The use of CFRP tubes introduces a novel phenomenon in the context of uneven temperature distribution. Results shed light on the mechanistic analysis of a cell side-wall rupture during thermal runaway and provide essential guidance for the next-generation safe battery design.

battery casing↗

Glycolysis of carbon fiber-epoxy unidirectional mat catalysed by sodium hydroxide

This study was conducted to recycle carbon fibre-epoxy (CFRP) composite in woven sheet/ mat form. The CFRP was recycled through glycolysis with polyethlyene glycol (PEG 200) as the solvent. The CFRP was loaded into the solvent at a ratio of 4:1 (w/w). PEG200 was diluted with water to a ratio of 80:20 (v/v). This reaction was catalysed by sodium hydroxide (NaOH) solution with varying concentrations at 1.5, 1.7 and 1.9% (w/v). The glycolysis was conducted at 180-190 °C. The recovered CF (rCF) was analysed using Fourier Transform Infrared (FTIR), Scanning Electron Microscopy (SEM) and Energy Dispersive X-Ray (EDX) while the degraded solution was analysed using FTIR and the epoxy content was determined. The FTIR spectrum of the rCF exhibited the disappearance of the COC peak belonged to epoxy and supported by the SEM micrographs that showed clear rCF. On the other hand, the analysed filtrate detected the disappearance of oxygen peak element in the EDX spectrum for all rCF samples. This gave an indication that the epoxy resin has been removed from the surface of the carbon fiber.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanical and Corrosion Assessment of Friction Self-Piercing Rivet Joint of Carbon Fiber-Reinforced Polymer and Magnesium Alloy AZ31B

In the present work, thermoset carbon fiber–reinforced polymer (CFRP) was spot joined to magnesium alloy AZ31B by a friction self-piercing riveting (F-SPR) process. Lap shear tensile and cross-tension testing were used to evaluate the mechanical joint performance. An average lap shear tensile load of 5.18 kN was achieved, while an average of 2.81 kN was found from cross-tension testing. All F-SPR samples showed a pullout of AZ31B after mechanical testing, indicating good mechanical interlocking between the steel rivet and AZ31B. Corrosion potential was measured for each material to establish the galvanic corrosion characteristics. As expected, AZ31B was found to be the most active, while thermoset CFRP was the most noble. The steel rivet fell between the AZ31B (active) and the thermoset CFRP (noble). Salt fog corrosion testing (ASTM B-117) was performed to evaluate the corrosion performance of the uncoated F-SPR joint. With up to 200 h of exposure, the post-corroded F-SPR joint integrity retained 81.2% of the pre-exposure F-SPR joint strength with AZ31B pullout failure mode. From cross-sectional analysis of the F-SPR joint, extensive corrosion of AZ31B was observed at the joint and other exposure areas. However, steel rivet was not significantly corroded due to sacrificial anode effect by which AZ31B corroded first in the galvanic couple.

36 MATERIALS SCIENCE↗

Stationary Shoulder Friction Stir Assisted Scribe Technique for Dissimilar Joining

We report on implementation of a stationary shoulder in dissimilar joints of Al-steel and Al-carbon fiber reinforced polymer (CFRP) using friction stir assisted scribe technology (FaST ). Viable joint strength similar to that with the conventional FAST process was demonstrated in Al-steel. A significant improvement in as-welded surface roughness for both Al-steel and Al-CFRP cases was achieved by using stationary shoulder. Interrupted lap shear tests performed on Al-steel joints and a corresponding computational model indicate the joint failure typically occurs in Al sheet via a crack tip that originates at the steel hook tip on the loading side. A similar fracture path was observed in an Al-CFRP joint.

Das, Hrishikesh↗

MECHANICAL AND CORROSION ASSESSMENT OF FRICTION SELF-PIERCING RIVET JOINT OF CARBON FIBER-REINFORCED POLYMER AND MAGNESIUM ALLOY AZ31B

In the present work, thermoset carbon fiber–reinforced polymer (CFRP) was spot joined to magnesium alloy AZ31B by a friction self-piercing riveting (F-SPR) process. Lap shear tensile and cross-tension testing were used to evaluate the mechanical joint performance. An average lap shear tensile load of 5.18 kN was achieved, while an average of 2.81 kN was found from cross-tension testing. All F-SPR samples showed pull-out of AZ31B after mechanical testing, indicating good mechanical interlocking between the steel rivet and AZ31B. Corrosion potential was measured for each material to establish the galvanic corrosion characteristics. As expected, AZ31B was found to be the most active, while thermoset CFRP was the most noble. The steel rivet fell between the AZ31B (active) and the thermoset CFRP (noble). Salt fog corrosion testing (ASTM B-117) was performed to evaluate the corrosion performance of the uncoated F-SPR joint. With up to 200 h of exposure, the post-corroded F-SPR joint integrity retained 81.2% of the pre-exposure F-SPR joint strength with AZ31B pull-out failure mode. From cross-sectional analysis of the F-SPR joint, extensive corrosion of AZ31B was observed at the joint and other exposure areas. However, steel rivet was not significantly corroded potentially due to sacrificial anode effect by which AZ31B corroded first in the galvanic couple.

Lim, Yong Chae↗

Enhanced lightning strike protection using vertically oriented carbon fiber melded with conventional carbon fiber-reinforced composite and its validation through damage analysis

Lightning strike protection (LSP) is one of the prime factors in aerospace and wind industries concerning safety, enhanced service life, and reduced downtime. To ensure better LSP, high electrical conductivity is required to dissipate the current, which is always a challenge for polymer composites due to the inherent insulating nature of the polymer matrix. Conventional carbon fiber-reinforced composites (CFRP) offer electrical conductivity in the planar direction while the vertical i.e. through-thickness conductivity still remains a challenge. Having been motivated by this fact, we have fabricated CFRP interleaved with vertically oriented CF (Z-fiber) for the lightning strike test (100 kA). A paint was applied to mimic the actual service condition of the composite laminates. We have prepared two Z-fiber composites: (a) Z-1 containing one Z-fiber layer on the top along with conventional CF layers and (b) Z-5 containing five interleaved Z-fiber layers and compared the properties with conventional CFRP (Z-0). Interestingly, even a single Z-fiber layer (Z-1) showed lower damage (visual damage diameter 22 mm) than Z-0 (visual damage diameter 26 mm). Z-5 displayed the lowest damage (visual damage diameter 16.7 mm), which was further confirmed by cross-sectional optical microscopy. Improved LSP was attributed to the higher through-thickness electrical conductivity in the case of Z-5 (9 times with respect to Z-0) reflecting a lower electrical anisotropy for Z-fiber composites. The residual mechanical property after the lightning test was analyzed through the flexural test, and the retention of flexural strength and modulus was 66% and 86%, respectively for Z-5 showing a significant improvement in comparison to Z-0 (>40% for both).

Saha, Subhabrata↗

High Strain Rate Mechanical Characterization of Carbon Fiber Reinforced Polymer Composites Using Digital Image Correlations

We present that the introduction of carbon fiber reinforced polymer (CFRP) composites to structural components in lightweight automotive structures necessitates an assessment to evaluate that their crashworthiness dynamic response provides similar or higher levels of safety compared to conventional metallic structures. In order to develop, integrate and implement predictive computational models for CFRP composites that link the materials design, molding process and final performance requirements to enable optimal design and manufacturing vehicle systems for this study, the dynamic mechanical response of unidirectional (UD) and 2x2 twill weave CRFP composites was characterized at deformation rates applicable to crashworthiness performance. Non-standardized specimen geometries were tested on a standard uniaxial frame and an intermediate-to-high speed dynamic testing frame, equipped with high speed cameras for 3D digital image correlation (DIC). Specimen cross-sections, according to each fiber orientation tested, were consistent across strain rates to ensure results were comparable. Tensile strength and modulus were experimentally investigated over a wide range of strain rates (0.0001 to 200 s -1 ). DIC was used to estimate strain profiles on composites surfaces, and the modulus was calculated from those strain measurements. Experimental results demonstrated an increase in the tensile strength of UD CFRP composites in the longitudinal (0°) and transverse (90°) direction with increasing strain rates. In contrast, the tensile strength of 2x2 woven composites and the tensile modulus of the UD material were insensitive to increasing strain rates. Finally, comparison of failure modes provided insights on how loading rates influenced failure mechanisms.

36 MATERIALS SCIENCE↗

Laboratory Accelerated Cyclic Corrosion Testing and On-Road Corrosion Testing of AA6××× Coupled to Carbon Fiber-Reinforced Plastics

Structures made from a combination of aluminum alloy (AA) and carbon fiber-reinforced plastic (CFRP) are susceptible to galvanic corrosion of the AA in harsh atmospheric conditions, such as might exist for closure panels in automotive applications. It is important to understand the galvanic corrosion behavior of these materials under laboratory conditions as that might allow prediction of performance in real environments. This work tested specially designed AA6×××-CFRP coupons, including AA6111 and AA6022, connected to CFRP made from two different carbon fiber fabrics (twill and random) with the aim of understanding the corrosion behaviors in a laboratory cyclic exposure chamber and during on-road exposure. The extent of corrosion was assessed by galvanic current measurements, optical profilometry, cross-sectional area analysis, and microscopic analysis. Based on the results, it was determined that the corrosion susceptibilities and morphologies observed in CFRP/AA couples tested in an environmental chamber for 12 weeks were in correspondence with those of the coupons subjected to on-road testing for 1 y in Columbus, OH.

Materials Science↗

Fracture mechanics in fiber reinforced composite materials, taking as examples B/A1 and CRFP

The validity of linear elastic fracture mechanics and other fracture criteria was investigated with laminates of boron fiber reinforced aluminum (R/A1) and of carbon fiber reinforced epoxide (CFRP). Cracks are assessed by fracture strength Kc or Kmax (critical or maximum value of the stress intensity factor). The Whitney and Nuismer point stress criterion and average stress criterion often show that Kmax of fiber composite materials increases with increasing crack length; however, for R/A1 and CFRP the curve showing fracture strength as a function of crack length is only applicable in a small domain. For R/A1, the reason is clearly the extension of the plastic zone (or the damage zone n the case of CFRP) which cannot be described with a stress intensity factor.

Peters, P. W. M.↗

Common Practice Lightning Strike Protection Characterization Technique to Quantify Damage Mechanisms on Composite Substrates

To support FAA certification airworthiness standards, composite substrates are subjected to lightning direct-effect electrical waveforms to determine performance characteristics of the lightning strike protection (LSP) conductive layers used to protect composite substrates. Test results collected from independent LSP studies are often incomparable due to variability in test procedures & applied practices at different organizations, which impairs performance correlations between different LSP data sets. Under a NASA supported contract, The Boeing Company developed technical procedures and documentation as guidance in order to facilitate a test method for conducting universal common practice lightning strike protection test procedures. The procedures obtain conformity in future lightning strike protection evaluations to allow meaningful performance correlations across data sets. This universal common practice guidance provides the manufacturing specifications to fabricate carbon fiber reinforced plastic (CFRP) test panels, including finish, grounding configuration, and acceptable methods for pretest nondestructive inspection (NDI) and posttest destructive inspection. The test operations guidance elaborates on the provisions contained in SAE ARP5416 to address inconsistencies in the generation of damage protection performance data, so as to provide for maximum achievable correlation across capable lab facilities. In addition, the guidance details a direct effects test bed design to aid in quantification of the multi-physical phenomena surrounding a lightning direct attachment supporting validation data requirements for the development of predictive computational modeling. The lightning test bed is designed to accommodate a repeatable installation procedure to secure the test panel and eliminate test installation uncertainty. It also facilitates a means to capture the electrical waveform parameters in 2 dimensions, along with the mechanical displacement and thermal heating parameters which occur during lightning attachment. Following guidance defined in the universal common practice LSP test documents, protected and unprotected CFRP panels were evaluated at 20, 40 and 100KAmps. This report presents analyzed data demonstrating the scientific usefulness of the common practice approach. Descriptions of the common practice CFRP test articles, LSP test bed fixture, and monitoring techniques to capture the electrical, mechanical and thermal parameters during lightning attachment are presented here. Two methods of measuring the electrical currents were evaluated, inductive current probes and a newly developed fiberoptic sensor. Two mechanical displacement methods were also examined, optical laser measurement sensors and a digital imaging correlation camera system. Recommendations are provided to help users implement the common practice test approach and obtain LSP test characterizations comparable across data sets.

Szatkowski, George N.↗

Observations of Non-Spherical, Graphite-Epoxy Projectiles Impacting a Thermally-Insulated, Double-Wall Shield

The DebriSat hypervelocity impact experiment, performed at the Arnold Engineering Development Center (U.S.A.F. Arnold Air Force Base), is intended to update the catastrophic break-up models for modern satellites. To this end, the DebrisSat was built with many modern materials including structural panels of carbon-fiber, reinforced polymer (CFRP). Subsequent to the experiment, fragments of the DebrisSat have been extracted from porous, catcher panels used to gather the debris from the impact event. Thus far, one of the key observations from the collected fragments is that CFRP represents a large fraction of the fragments and that these fragments tend to be thin, flake-like structures or long, needle-like structures; whereas, debris with nearly equal dimensions is less prevalent. As current ballistic-limit models are all developed based upon spherical impacting particles, the experiment has pointed to a missing component in the current approach that must be considered. To begin to understand the implications of this observation, simulations like those shown in Fig. 1 have been performed using cylindrical structures at a representative orbital speed into an externally-insulated, double-wall shield that is representative of shielding of International-Space-Station-visiting vehicles. These simulations have been performed for normal impacts to the surface with three different angles-of-attack (AOA) to capture the effect on the shield performance. This paper documents the simulated shield and the models developed to study the effect of non-spherical fragments, as well as, derives the critical characteristics of CFRP impacting particles for the selected shield as shown in Fig. 2. To assist with the design of the updated debris models, this work summarizes the simulated results into a deployable form for evaluating the relative importance of fragment structures.

Miller, Joshua E.↗

Simulation of Guided-Wave Ultrasound Propagation in Composite Laminates: Benchmark Comparisons of Numerical Codes and Experiment

Ultrasonic wave methods constitute the leading physical mechanism for nondestructive evaluation (NDE) and structural health monitoring (SHM) of solid composite materials, such as carbon fiber reinforced polymer (CFRP) laminates. Computational models of ultrasonic wave excitation, propagation, and scattering in CFRP composites can be extremely valuable in designing practicable NDE and SHM hardware, software, and methodologies that accomplish the desired accuracy, reliability, efficiency, and coverage. The development and application of ultrasonic simulation approaches for composite materials is an active area of research in the field of NDE. This paper presents comparisons of guided wave simulations for CFRP composites implemented using four different simulation codes: the commercial finite element modeling (FEM) packages ABAQUS, ANSYS, and COMSOL, and a custom code executing the Elastodynamic Finite Integration Technique (EFIT). Benchmark comparisons are made between the simulation tools and both experimental laser Doppler vibrometry data and theoretical dispersion curves. A pristine and a delamination type case (Teflon insert in the experimental specimen) is studied. A summary is given of the accuracy of simulation results and the respective computational performance of the four different simulation tools.

Composite↗