Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMPRESSORS - BLADES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Stall Margin Improvement in a Transonic Compressor with a Casing Treatment: Flow Mechanism

Effects of casing treatments for improved stall margin in transonic compressors are investigated. Two types of compressor casing treatments, circumferential grooves and axial slots casing treatments, are studied in detail. The primary objective of the current paper is to identify the underlying fluid mechanics that change the stall margin of transonic compressors with these two casing treatments. Large eddy simulation (LES) is applied to calculate the compressor flow fields with these two types of casing treatments. Calculated flow fields are first compared with measured experimental data to validate the LES simulation. Details of the calculated unsteady flow structures are examined to unearth the underlying flow mechanism for the improved stall margin. Further possible design optimization of the casing treatment for the stall margin extension without any performance penalty near the design condition is also explored.

compressor↗

Conceptual design study of a nuclear Brayton turboalternator-compressor

A comprehensive analysis and conceptual design study of the turboalternator-compressor components using HeXe as the working fluid was performed. The study was conducted in three phases: general configuration analysis (Phase 1), design variations (Phase 2), and conceptual design study (Phase 3). During the Phase 1 analysis, individual turbine, alternator, compressor, and bearing and seal designs were evaluated. Six turboalternator-compressor (TAC) configurations were completed. Phase 2 consisted of evaluating one selected Phase 1 TAC configuration to calculate its performance when operating under new cycle conditions, namely, one higher and one lower turbine inlet temperature and one case with krypton as the working fluid. Based on the Phase 1 and 2 results, a TAC configuration that incorporated a radial compressor, a radial turbine, a Lundell alternator, and gas bearings was selected. During Phase 3 a new layout of the TAC was prepared that reflects the cycle state points necessary to accommodate a zirconium hydride moderated reactor and a 400 Hz alternator. The final TAC design rotates at 24,000 rpm and produces 160 kWe, 480 V, 3-phase, 400 hertz power.

Source record↗

Preliminary performance of the Brayton 4.25 inch radial compressor operating in a helium xenon gas mixture

Compressor performance was mapped during the Brayton cycle power system testing. The range of testing included three shaft speeds: the design speed of 36,000 rpm, 10 percent overspeed (39,600 rpm), and 10 percent underspeed (32,400 rpm). A range of compressor inlet temperatures from 60 F to 120 F and discharge pressures from 20 to 45 psia were included. The effects of turbine inlet temperatures (from 1200 F to 1600 F) on the compressor were also studied. The data presented include plots of weight flow, compressor pressure ratio, efficiency, and temperature-rise ratio.

Asadourian, A. S.↗

Nuclear Brayton turboalternator-compressor (TAC) conceptual design study

A comprehensive analysis and conceptual design study of the turboalternator-compressor components was performed using HeXe as the working fluid. Individual turbine, alternator, compressor, and bearing and seal designs were evaluated. Six turboalternator-compressor TAC configurations were completed. One TAC configuration was evaluated to calculate its performance when operating under new cycle conditions,namely, one higher and one lower turbine inlet temperature and one case with krypton as the working fluid. Based on the results, a TAC configuration that incorporated a radial compressor, a radial turbine, a Lundell Alternator, and gas bearings was selected. A new layout of the TAC was prepared that reflects the cycle state points necessary to accommodate a zirconium hydride moderated reactor and a 400 Hz alternator. The final TAC design rotates at 24,000 rpm and produces 160 kWe, 480V, 3-phase, 400 hertz power.

Mock, E. A.↗

Thermodynamic properties of UF sub 6 measured with a ballistic piston compressor

From experiments performed with a ballistic piston compressor, certain thermodynamic properties of uranium hexafluoride were investigated. Difficulties presented by the nonideal processes encountered in ballistic compressors are discussed and a computer code BCCC (Ballistic Compressor Computer Code) is developed to analyze the experimental data. The BCCC unfolds the thermodynamic properties of uranium hexafluoride from the helium-uranium hexafluoride mixture used as the test gas in the ballistic compressor. The thermodynamic properties deduced include the specific heat at constant volume, the ratio of specific heats for UF6, and the viscous coupling constant of helium-uranium hexafluoride mixtures.

Sterritt, D. E.↗

Some comparisons of the flow characteristics of a turbofan compressor system with and without inlet pressure distortion

The measured effects of a circumferential distortion in inlet total pressure on the fan, low, and high compressor of an afterburning turbofan engine are presented and discussed. Extensive inner-stage instrumentation, combined with a unique test technique offered an accurate means of measuring the shifts in flow, performance, and stall mechanisms within the compressor. These effects are compared at one speed to the corresponding effects measured with undistorted inlet flow. The results show the rate at which the distorted flow areas were attenuated and rotated as well as the change in flow velocities that occurred at various points in the compressor. High response pressure traces indicated the location of stalls including the sequence of dynamic events from the onset and propagation of various stall-recovery events, to compressor surge, to the resulting hammershock.

Evans, D. G.↗

Some comparisons of the flow characteristics of a turbofan compressor system with and without inlet pressure distortion

The measured effects of a circumferential distortion in inlet total pressure on the fan, low, and high compressor of an afterburning turbofan engine are presented and discussed. Extensive inner-stage instrumentation, combined with a unique test technique offered an accurate means of measuring the shifts in flow, performance, and stall mechanisms within the compressor. These effects are compared at one speed to the corresponding effects measured with undistorted inlet flow. The results show the rate at which the distorted flow areas were attenuated and rotated, as well as the change in flow velocities that occurred at various points in the compressor. High response pressure traces indicated the location of stalls including the sequence of dynamic events from the onset and propagation of various stall-recovery events, to compressor surge, to the resulting hammershock.

Evans, D. G.↗

Effects of casing treatment on a small, transonic axial-flow compressor

Improved axial compressor surge margin through effective rotor casing treatment has been identified from test results on large axial compressors. A modified scale of a large compressor was built and tested to determine if similar improvements in surge margin could be duplicated in small-size turbomachinery. In addition, the effects of rotor radial running clearance, both with and without casing treatment, were investigated and are discussed. Test results of the scale configuration are presented and compared to the parent compressor.

Holman, F. F.↗

Analysis of dynamic inlet distortion applied to a parallel compressor model

An investigation of surge was conducted by using a parallel compressor model of the J85-13 compressor implement on an analog computer. Surges were initiated by various types of dynamic disturbances in inlet pressure. The compressor model was less sensitive to disturbances of short duration, high frequency, and long duration where the compressor discharge pressure could react. Adding steady distortion to dynamic disturbances reduced the amount of dynamic disturbance required to effect surge. Steady and unsteady distortions combined linearly to reduce surge margin.

Wenzel, L. M.↗

Field verification of lateral-torsional coupling effects on rotor instabilities in centrifugal compressors

Lateral and torsional vibration data obtained on a centrifugal compressor train which had shaft instabilities and gear failures is examined. The field data verifies that the stability of centrifugal compressors can be adversely affected by coincidence of torsional natural frequencies with lateral instability frequencies. The data also indicates that excitation energy from gear boxes can reduce stability margins if energy is transmitted either laterally or torsionally to the compressors. The lateral and torsional coupling mechanisms of shaft systems is discussed. The coupling mechanisms in a large industrial compressor train are documented and the potential effect on rotor stability is demonstrated. Guidelines are set forth to eliminate these potential problems by minimizing the interaction of torsional and lateral responses and their effect on rotor stability.

Wachel, J. C.↗

Effect of humidity on jet engine axial-flow compressor performance

Two problems related to the ingestion of humid air into jet engine axial compressors have been studied: (1) the changes in the performance of the compressor in the absence of condensation and (2) the changes in the entry conditions to the compressor when condensation occurs. Regarding the first, the extent of changes are predicted and also measured in the case of a six-stage compressor operated with air-methane gas mixture utilizing the similarities in the thermodynamic properties between water vapor and methane. For the condensation process in an inlet, a model is described that takes into account the presence of micro particulates and the flow field changes in the vicinity of the inlet wall. Finally, the effects of humidity on engine performance are discussed in relation to engine trim and control schemes.

Ehresman, C. M.↗

A theory of rotating stall of multistage axial compressors. I - Small disturbances

An analysis is made of rotating stall in compressors of many stages, finding conditions under which a flow distortion can occur which is steady in a traveling reference frame, even through upstream total and downstream static pressure are constant. In the compressor, a pressure-rise hysteresis is assumed. Flow in entrance and exit ducts yield additional lags. These lags balance to give a formula for stall propagation speed. For small disturbances, it is required that the compressor characteristics be flat in the neighborhood of average flow coefficient. Results are compared with the experiments of Day and Cumpsty. If a compressor lag of about twice that due only to fluid inertia is used, predicted propagation speeds agree almost exactly with experimental values, taking into account changes of number of stages, stagger angle, row spacing, and number of stall zones. The agreement obtained gives encouragement for the extension of the theory to account for large amplitudes.

Moore, F. K.↗

Experimental on-stream elimination of resonant whirl in a large centrifugal compressor

Resonant whirl condition during operation of a multi-stage centrifugal compressor at higher than anticipated speeds and loads was reported. The condition was diagnosed by a large scale computerized Machinery Condition Monitoring System (MACMOS). This computerized system verified that the predominant subsynchronous whirl frequency locked in on the first resonant frequency of the compressor rotor and did not vary with compressor speed. Compressor stability calculations showed the rotor system had excessive hearing stiffness and inadequate effective damping. An optimum bearing design which was developed to minimize the unbalance response and to maximize the stability threshold is presented.

Bhat, G. I.↗

The design and development of an oil-free compressor for Spacelab Refrigerator/Freezer

Design features and test results of an oil-free compressor developed for Spacelab Mission-4 Refrigerator/Freezer are detailed. The compressor has four identical pistons activated by a common eccentric shaft, operated by a brushless dc motor at 1300 rpm. The stroke of each piston is 0.28 cm, with the piston ends connected to the shaft by means of sealed needle bearings, eliminating the ned for oil. The mass flow rates produced by the compressor are by over 100 percent higher compared to the original Amfridge unit. Test results show that the compressor can meet the Spacelab refrigerator/freezer requirements.

Hye, A.↗

Improved heat switch for gas sorption compressor

Thermal conductivities of the charcoal bed and the copper matrix for the gas adsorption compressor were measured by the concentric-cylinder method. The presence of the copper matrix in the charcoal bed enhanced the bed conductance by at least an order of magnitude. Thermal capacities of the adsorbent cell and the heat leaks to two compressor designs were measured by the transient method. The new gas adsorption compressor had a heat switch that could transfer eight times more heat than the previous one. The cycle time for the new prototype compressor is also improved by a factor of eight to within the minute range.

Chan, C. K.↗

Extended parametric representation of compressor fans and turbines. Volume 1: CMGEN user's manual

A modeling technique for fans, boosters, and compressors has been developed which will enable the user to obtain consistent and rapid off-design performance from design point input. The fans and compressors are assumed to be multi-stage machines incorporating front variable stators. The boosters are assumed to be fixed geometry machines. The modeling technique has been incorporated into time sharing program to facilitate its use. Because this report contains a description of the input output data, values of typical inputs, and examples cases, it is suitable as a user's manual. This report is the first of a three volume set describing the parametric representation of compressors, fans, and turbines. The titles of the three volumes are as follows: (1) Volume 1 CMGEN USER's Manual (Parametric Compressor Generator); (2) Volume 2 PART USER's Manual (parametric Turbine); (3) Volume 3 MODFAN USER's Manual (Parametric Modulating Flow Fan).

Converse, G. L.↗

Extended parametric representation of compressor fans and turbines. Volume 3: MODFAN user's manual (parametric modulating flow fan)

A modeling technique for single stage flow modulating fans or centrifugal compressors has been developed which will enable the user to obtain consistent and rapid off-design performnce from design point input. The fan flow modulation may be obtained by either a VIGV (variable inlet guide vane) or a VPF (variable pitch rotor) option. Only the VIGV option is available for the centrifugal compressor. The modeling technique has been incorporated into a time-sharing program to facilitate its use. Because this report contains a description of the input output data, values of typical inputs, and examples cases, it is suitable as a user's manual. This report is the last of a three volume set describing the parametric representation of compressor fans, and turbines. The titles of the three volumes are as follows: (1) Volume 1 CMGEN USER's Manual (Parametric Compressor Generator); (2) Volume 2 PART USER's Manual (Parametric Turbine); (3) Volume 3 MODFAN USER's Manual (Parametric Modulating Flow Fan).

Converse, G. L.↗

T55-L-712 turbine engine compressor housing refurbishment-plasma spray project

A study was conducted to assess the feasibility of reclaiming T55-L-712 turbine engine compressor housings with an 88 wt percent aluminum to 12 wt percent silicon alloy applied by a plasma spray process. Tensile strength testing was conducted on as-sprayed and thermally cycled test specimens which were plasma sprayed with 0.020 to 0.100 in. coating thicknesses. Satisfactory tensile strength values were observed in the as-sprayed tensile specimens. There was essentially no decrease in tensile strength after thermally cycling the tensile specimens. Furthermore, compressor housings were plasma sprayed and thermally cycled in a 150-hr engine test and a 200-hr actual flight test during which the turbine engine was operated at a variety of loads, speeds and torques. The plasma sprayed coating system showed no evidence of degradation or delamination from the compressor housings. As a result of these tests, a procedure was designed and developed for the application of an aluminum-silicon alloy in order to reclaim T55-L-712 turbine engine compressor housings.

Leissler, George W.↗