Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONDUCTIVE HEAT TRANSFER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Comprehensive Digital Twin of a Macro-fluidic Electrochemical Reactor to Optimize the Electrochemical-based Recovery of O2 from Metabolic CO2

Future long-duration missions will require a sustainable and efficient system capable of yielding a minimum of 75% O 2 recovery from metabolic CO 2 to achieve self-sufficiency for long space missions beyond Earth's low orbit. A Macro-fluidic Electrochemical Reactor (MFECR) development effort to electrochemically recover O 2 from CO 2 is underway at NASA Marshall Space Flight Center (MSFC) to increase current O 2 recovery efficiency and reduce air revitalization (AR) system complexity at the International Space Station (ISS) habitat and future long missions. The authors have developed and deployed a digital twin of an actual single cell of the MFECR via a comprehensive 3D multiphysics model that thoroughly replicates the exact configuration and fluid/material domains of the MFECR. This model's electrochemical physics consists of multicomponent-multiphase electrochemical-driven reactions leading to CO 2 conversion to C 2 H 4 and CO along with the formation of H 2 on the cathode in parallel with the generation of O 2 and H 2 O on the anode. This electrochemical model is coupled with all the physics phenomena involved in the process, including but not limited to fluid and non-ideal mass transfer of reactant and product species in free and porous media, convective/conduction/radiative heat transfer, and conduction of DC electrical current with Joule heating generation. The digital twin has proved to be an essential tool for performing different qualitative studies, including the effect of reducing the height (increasing the respect ratio) of the serpentine walls, leading to a further redesign of the EDU (the newly redesigned MFECR EDU has been fabricated and is expected to be used in future tests), the evaluation of setting different MFECRs connected in series, and the assessment of feeding air directly to the MFECR skipping the preceding metabolic CO 2 separation from air. The MFECR's test stand is fully automated and equipped with several inline measurements (flow, pressure, temperature, pH, component concentration) systems on all six MFECR's IO streams, allowing reliable experimental validation of the model, parametric determination of all electrochemical reactions, and process optimization.

Jesus A Dominguez↗

Experimental Investigation of Jet Impingement Heat Transfer Using Thermochromic Liquid Crystals

Jet impingement cooling of a hypersonic airfoil leading edge is experimentally investigated using thermochromic liquid crystals (TLCS) to measure surface temperature. The experiment uses computer data acquisition with digital imaging of the TLCs to determine heat transfer coefficients during a transient experiment. The data reduction relies on analysis of a coupled transient conduction - convection heat transfer problem that characterizes the experiment. The recovery temperature of the jet is accounted for by running two experiments with different heating rates, thereby generating a second equation that is used to solve for the recovery temperature. The resulting solution requires a complicated numerical iteration that is handled by a computer. Because the computational data reduction method is complex, special attention is paid to error assessment. The error analysis considers random and systematic errors generated by the instrumentation along with errors generated by the approximate nature of the numerical methods. Results of the error analysis show that the experimentally determined heat transfer coefficients are accurate to within 15%. The error analysis also shows that the recovery temperature data may be in error by more than 50%. The results show that the recovery temperature data is only reliable when the recovery temperature of the jet is greater than 5 C, i.e. the jet velocity is in excess of 100 m/s. Parameters that were investigated include nozzle width, distance from the nozzle exit to the airfoil surface, and jet velocity. Heat transfer data is presented in graphical and tabular forms. An engineering analysis of hypersonic airfoil leading edge cooling is performed using the results from these experiments. Several suggestions for the improvement of the experimental technique are discussed.

Dempsey, Brian Paul↗

Comparison of Experimental and Computational Aerothermodynamics of a 70-deg Sphere-Cone

Numerical solutions for hypersonic flows of carbon-dioxide and air around a 70-deg sphere-cone have been computed using an axisymmetric non-equilibrium Navier-Stokes solver. Freestream flow conditions for these computations were equivalent to those obtained in an experimental blunt-body heat-transfer study conducted in a high-enthalpy, hypervelocity expansion tube. Comparisons have been made between the computed and measured surface heat-transfer rates on the forebody and afterbody of the sphere-cone and on the sting which supported the test model. Computed forebody heating rates were within the estimated experimental uncertainties of 10% on the forebody and 15% in the wake except for within the recirculating flow region of the wake.

Hollis, Brian R.↗

An implicit-iterative solution of the heat conduction equation with a radiation boundary condition

For the problem of predicting one-dimensional heat transfer between conducting and radiating mediums by an implicit finite difference method, four different formulations were used to approximate the surface radiation boundary condition while retaining an implicit formulation for the interior temperature nodes. These formulations are an explicit boundary condition, a linearized boundary condition, an iterative boundary condition, and a semi-iterative boundary method. The results of these methods in predicting surface temperature on the space shuttle orbiter thermal protection system model under a variety of heating rates were compared. The iterative technique caused the surface temperature to be bounded at each step. While the linearized and explicit methods were generally more efficient, the iterative and semi-iterative techniques provided a realistic surface temperature response without requiring step size control techniques.

Williams, S. D.↗

Cryogenic Flow Boiling in Microgravity: Effects of Reduced Gravity on Two-Phase Fluid Physics and Heat Transfer

With the growing interest in space exploration, cryogenic technologies involving two-phase flow and heat transfer are in high demand to successfully procure advanced space applications such as fuel depots and nuclear thermal propulsion (NTP) systems for deep space missions. However, the unique and extreme thermal properties of cryogenic fluids introduce distinct flow boiling fluid physics and energy transport phenomena, which differ significantly from those observed with conventional fluids. Understanding the unique two-phase physics in cryogenic flow boiling remains an ongoing challenge. Furthermore, the lack of readily available microgravity cryogenic steady-state heat transfer data hinders the assessment of gravitational effects on cryogenic flow boiling. This study aims to elucidate the gravitational effects on two-phase fluid physics and heat transfer by conducting the first-ever experimental measurement of cryogenic flow boiling performance using a steady-state heated method in a reduced gravity environment. Parabolic flight experiments were performed to acquire both heat transfer measurements and high-speed video of interfacial behaviors, under varying gravity levels (microgravity, hypergravity, Lunar gravity, and Martian gravity). The experiments involved flow boiling of liquid nitrogen (LN 2 ) with a near-saturated inlet along a circular heated tube of dimensions 8.5-mm inner diameter and 680-mm heated length. The operating parameters varied are mass velocity of 398.3 - 1342.8 kg/m2s, inlet quality of -0.08 to -0.01, and inlet pressure of 413.68 - 689.48 kPa. Captured microgravity flow patterns range from bubbly to annular, all having vapor structures that are larger than those under higher gravity levels. Under microgravity, absence of buoyancy yields symmetrical vapor structures without flow stratification, laying a physical foundation for the distinct two-phase heat transfer trends during LN 2 flow boiling in microgravity. Transient data collected during the flight parabolas exhibited decreasing heated wall temperature as the aircraft transitioned from hypergravity to microgravity phases. The temperature variation indicated an enhancement in flow boiling heat transfer with decreasing gravity levels and a reduction with increasing gravity levels. The effect of reduced gravity on cryogenic flow boiling heat transfer coefficient (HTC) is discussed based on steady state heat transfer analysis. Seminal HTC correlations are evaluated against the measured microgravity HTC data, of which one is identified for superior accuracy in predicting microgravity data. Finally, a new HTC correlation is proposed to improve accuracy of microgravity predictions, yet there still exists room for further improvement with future terrestrial flow boiling experiments at different flow orientations relative to Earth gravity.

Microgravity↗

Transient heat transfer and thermophysical properties measurements in low gravity

Theoretical computer models and correlations which describe phenomena important in the design of transient heat transfer systems are verified and extended. Attention is given to heat transfer to a fluid near the thermodynamic critical point, i.e., a highly compressible fluid. The validity of the computer model is tested by conducting heat-transfer experiments in a low gravity environment where gravity-driven motion is essentially eliminated. It is noted that the NASA KC135 aircraft provides a useful low-g platform for experimental work and provides valuable experience and background for experiments ultimately designed to fly on the Space Shuttle.

Giarratano, P. J.↗

Experimental and Numerical Characterization of a Cylindrical Blackbody Cavity

During hypersonic flight, high temperatures and high heat fluxes are generated on the surfaces of vehicles. The Flight Loads Laboratory (FLL) at Dryden Flight Research Center (DFRC) is equipped with a calibration furnace, capable of calibrating heat flux gages up to 1100kW per square meters, and temperature sensors up to 2600 C. One heating configuration of the calibration furnace is a cylindrical blackbody cavity. Throughout the blackbody there are temperature gradients due to various boundary conditions. These boundary conditions include resistance heating, radiant heat transfer, and conduction to water-cooled electrodes. Also, an inert gas is purged through the graphite blackbody to prevent it from oxidizing. Consequently, the various modes of heat transfer present during operation of the blackbody cavity must be well understood in order to produce accurate heat flux gage and temperature sensor calibrations for use in ground testing or flight testing of hypersonic vehicles. The first step towards understanding the heat transfer in the blackbody cavity was to perform experiments at 1100 C, with and without outer surface insulation, while taking detailed temperature measurements inside the blackbody cavity. Steady state thermal models of the blackbody cavity were then developed. These models included detailed thermal analysis using commercial thermal analysis software. Conduction, radiation, and convection were considered in the thermal models for two cases: one with the outside of the blackbody cavity insulated and the second without insulation. This paper describes the experimental and numerical efforts used to characterize the steady state operation of the blackbody cavity. It describes the analysis of the test measurements, the boundary conditions used in the numerical models, and how the models were calibrated to fit the experimental data. Effects of various uncertainties, such as material properties, and convection are discussed.Initial thermal models predicted temperatures in the deepest part of the blackbody cavity within 7 C of the measured value and produced trends comparable to the experimental data, throughout the models. Adjustment of the boundary conditions, which were included in the thermal models, produced good agreement with measured temperatures. Free and forced convection of the purge gas inside the blackbody was found to be insignificant.

Abdelmessih, Amanie N.↗

Heat Transfer Measurement and Modeling in Rigid High-Temperature Reusable Surface Insulation Tiles

Heat transfer in rigid reusable surface insulations was investigated. Steady-state thermal conductivity measurements in a vacuum were used to determine the combined contribution of radiation and solid conduction components of heat transfer. Thermal conductivity measurements at higher pressures were then used to estimate the effective insulation characteristic length for gas conduction modeling. The thermal conductivity of the insulation can then be estimated at any temperature and pressure in any gaseous media. The methodology was validated by comparing estimated thermal conductivities with published data on a rigid high-temperature silica reusable surface insulation tile. The methodology was also applied to the alumina enhanced thermal barrier tiles. Thermal contact resistance for thermal conductivity measurements on rigid tiles was also investigated. A technique was developed to effectively eliminate thermal contact resistance on the rigid tile s cold-side surface for the thermal conductivity measurements.

Daryabeigi, Kamran↗

Analytical modeling of helium II in forced flow conditions

A numerical model was developed to examine the flow behavior of He II under forced flow conditions. The model basically solves the governing equations in the two-fluid model of He II, and can be used to assess the pump requirement for transferring He II in spaceborne systems. Predictions of liquid temperature and pressure drop agree well with empirical data obtained from small scale tests. At high transfer rates, the model predicts that the forced convection dominates the Gorter-Mellink conduction in heat transfer, and the classical turbulent flow correlation is sufficient for calculating the pressure drop across the transfer line.

Ng, Y. S.↗

Technology and Advanced Development for a Non-Toxic Orbital Maneuvering System and Reaction Control System for Orbiter Upgrade

NASA intends to pursue technology applications to upgrade the Space Shuttle Orbiter OMS and RCS systems with non-toxic propellants. The primary objectives of an upgraded OMS/RCS are improved safety and reliability, reduced operations and maintenance costs while meeting basic OMS/RCS operational and performance requirements. The OMS/RCS has a high degree of direct interaction with the crew and requires subsystem and components that are compatible with integration into the orbiter vehicle with regard to external mold-line, power and thermal control The non-toxic propulsion technology is also applicable to future Human Exploration and Development of Space (HEDS) missions. The HEDS missions have similar requirements for attitude control and lander descent/ascent propulsion and which will emphasize the use of In-Situ Resource for propellants. When used as a regenerative coolant as in the Shuttle Orbiter OMS combustion chamber, non-toxic fuels such as ethanol are limited in their cooling capacity by the bulk temperature rise permitted to prevent film boiling or possible coking. Typical regeneratively cooled chambers are constructed from highly conductive copper, which maximizes heat transfer, or from low conductivity materials like stainless steel that can also exacerbate cooling problems. For an ethanol cooled application the heat transfer into the fluid must be controlled to reduce the fuel coolant bulk temperature rise. An approach to provide this control is the subject of this report. This report is being issued to document work done by Aerojet on NASA contract NAS 8-98042. Specifically, this project investigates of the use of ethanol, a designated non-toxic fuel, as a coolant for the Space Shuttle Orbital Maneuvering System Engine combustion chamber. The project also addresses a cost reducing fabrication technique for construction of such a combustion chamber. The study contained three major sub-tasks: an analytical investigation and trade study which included layout of a flight type chamber concept, the fabrication and evaluation of formed platelet liner panels and the preparation and testing of mechanical properties specimens representative of a novel hot gas wall concept.

Hayes, W. A.↗

Heat transfer test of an 0.006-scale thin-skin thermocouple space shuttle model (50-0, 41-T) in the NASA-Ames Research Center 3.5-foot hypersonic wind tunnel at Mach 5.3 (IH28), volume 1

Data obtained from a heat transfer test conducted on an 0.006-scale space shuttle orbiter and external tank in the NASA-Ames Research Center 3.5-foot Hypersonic Wind Tunnel are presented. The purpose of this test was to obtain data under simulated return-to-launch-site abort conditions. Configurations tested were integrated orbiter and external tank, orbiter alone, and external tank alone at angles of attack of 0, + or - 30, + or - 60, + or - 90, and + or - 120 degrees. Runs were conducted at Mach numbers of 5.2 and 5.3 for Reynolds numbers of 1.0 and 4.0 million per foot, respectively. Heat transfer data were obtained from 75 orbiter and 75 external tank iron-constantan thermocouples.

Cummings, J. W.↗

Metallized Gelled Propellants: Oxygen/RP-1/Aluminum Rocket Engine Calorimeter Heat Transfer Measurements and Analysis

A set of analyses was conducted to determine the heat transfer characteristics of metallized gelled liquid propellants in a rocket engine. The analyses used the data from experiments conducted with a small 30- to 40-lbf thrust engine composed of a modular injector, igniter, chamber and nozzle. The fuels used were traditional liquid RP-1 and gelled RP-1 with 0-wt %, 5-wt%, and 55-wt% loadings of aluminum with silicon dioxide gellant, and gaseous oxygen as the oxidizer. Heat transfer was computed based on measurements using calorimeter rocket chamber and nozzle hardware with a total of 31 cooling channels. A gelled fuel coating formed in the 0-, 5- and 55-wt% engines, and the coating was composed of unburned gelled fuel and partially combusted RP-1. The coating caused a large decrease in calorimeter engine heat flux in the last half of the chamber for the 0- and 5-wt% RP-1/Al. This heat flux reduction effect was analyzed by comparing engine runs and the changes in the heat flux during a run as well as from run to run. Heat transfer and time-dependent heat flux analyses and interpretations are provided. The 5- and 55-wt% RP-1/Al fueled engines had the highest chamber heat fluxes, with the 5-wt% fuel having the highest throat flux. This result is counter to the predicted result, where the 55 wt% fuel has the highest combustion and throat temperature, and therefore implies that it would deliver the highest throat heat flux. The 5-wt% RP-1/Al produced the most influence on the engine heat transfer and the heat flux reduction was caused by the formation of a gelled propellant layer in the chamber and nozzle.

Palaszewski, Bryan↗

Aerodynamic heat transfer to a hypersonic research aircraft model /X-24C/ at Mach 6

The paper reports on results of heat-transfer tests conducted on a 1/29-scale model of the X-24C-12I hypersonic research aircraft configuration in a Mach 6 tunnel at a Reynolds number of thirteen million using the phase-change heat transfer technique. Sequences of phase-change heat transfer pattern photographs are presented showing windward side and leeward side heating processes. Theoretical predictions of dimensionless heat transfer coefficients along a data line on lower fuselage and on fuselage side bracket the experimental values. A turbulent heating theory gives good agreement with data when shifted to a new virtual origin.

Lawing, P. L.↗

Analysis of fully developed turbulent heat transfer at low Peclet numbers in smooth tubes with application to liquid metals

An analysis was made of heat transfer at low Peclet numbers for fluids flowing turbulently in smooth tubes. Previous analyses for flow of gases and liquid metals at low Peclet numbers gave higher heat-transfer coefficients than were indicated experimentally. When the mixing-length theory was modified in order to account for the heat transferred by conduction to a turbulent particle as it moves transversely, the predicted results were brought into agreement with the experimental results.

PIPES↗

Effects of rotation on coolant passage heat transfer. Volume 2: Coolant passages with trips normal and skewed to the flow

An experimental program was conducted to investigate heat transfer and pressure loss characteristics of rotating multipass passages, for configurations and dimensions typical of modem turbine blades. This experimental program is one part of the NASA Hot Section Technology (HOST) Initiative, which has as its overall objective the development and verification of improved analysis methods that will form the basis for a design system that will produce turbine components with improved durability. The objective of this program was the generation of a data base of heat transfer and pressure loss data required to develop heat transfer correlations and to assess computational fluid dynamic techniques for rotating coolant passages. The experimental work was broken down into two phases. Phase 1 consists of experiments conducted in a smooth wall large scale heat transfer model. A detailed discussion of these results was presented in volume 1 of a NASA Report. In Phase 2 the large scale model was modified to investigate the effects of skewed and normal passage turbulators. The results of Phase 2 along with comparison to Phase 1 is the subject of this Volume 2 NASA Report.

Johnson, B. V.↗

Heat transfer characteristics of porous media

An investigation was conducted regarding the relative effects of conduction and convection in a saturated porous medium. A method reported by Singh et al. (1973) is used to determine the effective thermal conductivity of the saturated porous material. Heat transfer measurements are conducted under conditions of forced convection of the saturated liquid parallel and countercurrent to the flow of heat. The results are compared with the data obtained with the aid of an analytical model.

Singh, B. S.↗