Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONTROLS - STABILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Experimental Evidence on Latency in a Fleet of Controllable Water Heaters

Demand response is an important emerging part of smart grids with wide coverage in theoretical and modeling research. However, experimental evidence on the real-life behavior of controllable loads is still limited. We present observations regarding latency and communication aspects of the operation on a fleet of residential water heaters in a smart neighborhood in Atlanta, GA. Our analysis shows that latency in water heaters is not constant and does not follow a Gaussian distribution. We also find that there is a systematic relationship between latency and hour of the day. Latency was found to increase during morning and evening hours compared to the afternoon. These findings could help better plan deployment of control for demand response programs. Understanding delays associated with controlling smart devices is crucial for proper design and algorithm development for optimization, frequency of dispatch, and override detection.

communication delay↗

Using Synchronization as an Indicator of Controllability in a Fleet of Water Heaters

Peak reduction is an important concern that can help reduce the growing stress on distribution grid and allow to defer investments in new capacity. However, the growing concern for customer privacy and comfort may impact the performance of load control for residential devices. Water heaters represent a convenient way of reducing peak due to their ability to store thermal energy for future use. In this paper, we developed a methodology to help utilities gain more insight with respect to the impact of load control efforts for shaving peak with no necessary information about the water heaters except the device status (on/off). To this end, we use a fleet of water heaters in a controlled residential neighborhood in Atlanta, GA. Our findings show that convergence in device status can serve as a proxy for peak shifting during hours of the evening peak.

demand response↗

Modern control system applications at Fermilab with Dart and Flutter

The control system at Fermilab is undergoing an unprecedented modernization effort. Hundreds of legacy applications originally developed with technology from the early nineties will be replaced with a suite of modern web applications. The selection of an user interface framework is a key technology decision that will impact on all the applications developed over the next decade. The Controls department at Fermilab has decided to use Google’s Dart language and Flutter framework for future application development. In this paper we will discuss the decision process that selected Dart/Flutter and the development of early general purpose control system applications with the framework.

Diamond, John [Fermilab]↗

Supervisory-level control system demand control of an HVAC system

A supervisory-level control system is provided and includes a summation unit receptive of first and second signals, an HVAC system to generate the second signal according to first set-point signals and to a second set-point signal and a supervisory controller. The supervisory controller includes a control unit, a set-point scheduler and a zone level set-point distribution unit. The control unit is receptive of an error signal representing a difference between the first and second signals from the summation unit. The set-point scheduler is receptive of a demand signal generated by the control unit according to the error signal. The set-point scheduler generates a set-point command signal and the second set-point signal according to the demand signal. The zone level set-point distribution unit is configured to generate the first set-point signals in accordance with the set-point command signal.

Adetola, Veronica↗

Theoretical Control-Centric Modeling for Precision Model-Based Sliding Mode Control of a Hydraulic Artificial Muscle Actuator

Artificial muscles (AMs) typically rely on pneumatic sources of fluid power. The use of hydraulics can increase the power and force to weight and volume ratios of AM actuators. This paper develops a control-centric third-order single-input single-output (SISO) lumped-parameter dynamic model and sliding mode position controller based on Filippov's principle of equivalent dynamics for a braided hydraulic artificial muscle (HAM) actuator. The model predicts the nonlinear behavior of the HAM free contraction and captures the fluid and actuator nonlinear dynamic interactions in addition to the braid deformation. Model simulations are compared to experimental results for quasi-static pressurization, isometric pressurization, and open-loop square wave commands at 0.25, 0.5, and 1 Hz. Experiments of sine wave tracking at 0.25, 0.5, and 1 Hz and continuous square wave tracking at 0.067 Hz are conducted using a sliding mode controller (SMC) derived from the model. The SMC achieves a steady-state error of 6 μm at multiple setpoints within the actuator's 17 mm stroke. Compared to a proportional-integral-derivative (PID) controller, the SMC root-mean-square (RMS) error, mean error, and absolute maximum error are reduced on average by 53%, 61%, and 44%, respectively, demonstrating the benefit of model-based approaches for controlling HAMs.

42 ENGINEERING↗

Controlling Rheology of Fluid Interfaces through Microblock Length of Sequence-Controlled Amphiphilic Copolymers

Previous studies have demonstrated that films of sequence-controlled amphiphilic copolymers display contact angles that depend on microblock size. This suggests that microblock length may provide a means of tuning surface and interfacial properties. In this work, the interfacial rheology of a series of sequence-controlled copolymers, prepared through the addition of bicyclo[4.2.0]oct-1(8)-ene-8-carboxamide (monomer A) and cyclohexene (monomer B) to generate sequences up to 24 monomeric units composed of (A m B n ) i microblocks, where m, n, and i range from 1 to 6. Interfacial rheometry is used to measure the mechanical properties of an air–water interface with these copolymers. As the microblock size increases, the interfacial storage modulus, G', increases, which may be due to an increase in the size of interfacial hydrophobic domains. Small-angle X-ray scattering shows that the copolymers have a similar conformation in solution, suggesting that any variations in the mechanics of the interface are due to assembly at the interface, and not on solution association or bulk rheological properties. This is the first study demonstrating that microblock size can be used to control interfacial rheology of amphiphilic copolymers. Here, the results provide a new strategy for controlling the dynamics of fluid interfaces through precision sequence-controlled polymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The wave energy converter control competition (WECCCOMP): Wave energy control algorithms compared in both simulation and tank testing

The wave energy control competition established a benchmark problem which was offered as an open challenge to the wave energy system control community. The competition had two stages: In the first stage, competitors used a standard wave energy simulation platform (WEC-Sim) to evaluate their controllers while, in the second stage, competitors were invited to test their controllers in a real-time implementation on a prototype system in a wave tank. The performance function used was based on converted energy across a range of standard sea states, but also included aspects related to economic performance, such as peak/average power, peak force, etc. This paper compares simulated and experimental results and, in particular, examines if the results obtained in a linear system simulation are borne out in reality. Overall, within the scope of the device tested, the range of sea states employed, and the performance metric used, the conclusion is that high-performance WEC controllers work well in practice, with good carry-over from simulation to experimentation. However, the availability of a good WEC mathematical model is deemed to be crucial.

16 TIDAL AND WAVE POWER↗

Robust cooperative control strategy for a platoon of connected and autonomous vehicles against sensor errors and control errors simultaneously in a real-world driving environment

In a real-world driving environment, a platoon of connected and autonomous vehicles (CAVs) is subject to many internal and external disturbances, resulting in uncertain vehicle dynamics. In general, the disturbances can be categorized into two types: disturbances due to vehicle sensor errors (e.g., GPS error) and disturbances due to vehicle control errors (e.g., actuator delay). In the literature, many control strategies have been proposed to improve the robustness of the CAV platoon against uncertain vehicle dynamics induced by these disturbances. However, most of these strategies only consider one type of disturbance and cannot tackle both types of disturbances simultaneously. Furthermore, they are designed to maximize the benefits of each vehicle in the platoon independently, which can deteriorate the performance of the platoon. Here, to address these problems, this study proposes a robust cooperative control (RCC) strategy to maneuver the vehicles in the platoon cooperatively to counteract the impacts of both types of disturbances. The RCC strategy is developed based on a minimax problem, where the maximization subproblem seeks to find the worst inputs for the uncertainty terms in the vehicle dynamics equation to minimize the platoon performance, while the minimization subproblem seeks to find the optimal control decisions for all subsequent vehicles to maximize the platoon performance in the worst case. To solve the minimax problem, this study proposes a globally convergent solution algorithm. It can solve the minimax problem very efficiently to enable real time deployment of the RCC strategy. Numerical application indicates that compared to the existing methods, the RCC strategy can dramatically improve the robustness of the CAV platoon against the uncertain vehicle dynamics induced by both vehicle state detection errors and vehicle control errors. Therefore, it can maneuver the CAV platoon safely and efficiently in a real-world driving environment.

33 ADVANCED PROPULSION SYSTEMS↗

Traffic Signal Control for Large-Scale Urban Traffic Networks: Real-World Experiments using Vision-Based Sensors

Effective control of traffic signals plays a critical role in ensuring smooth vehicle flow in urban areas. Expertly engineered traffic signal controllers can considerably minimize travel delays and enhance sustainability. In this paper, the team proposes the Model Predictive Control (MPC) traffic signal control strategy using real-time traffic flow data from a vision-based camera as feedback information. Also, a realistic signal timing plan that considers National Electrical Manufacturers Association (NEMA) constraints has been developed to be applied to real-world scenarios. The primary aim is to reduce the number of vehicles across all links in the controlled area, thereby optimizing traffic flow and reducing energy consumption. To validate the proposed method, several real-life experiments were conducted at 24 intersections in Chattanooga, Tennessee, by collaborating with traffic field engineers. These experiments demonstrated significant performance improvements in comparison to the existing method.

data processing↗

Phasor Based Control with the Distributed, Extensible Grid Control Platform

This paper describes how to implement Phasor Based Control (PBC) using the Distributed, Extensible Grid Control (DEGC) Platform. PBC is a novel method for controlling distributed energy resources (DER) that coordinates a centralized optimization with distributed feedback controllers to enforce voltage phasor targets. DEGC is an open source software and communication platform designed for general DER control. We deployed PBC at Lawrence Berkeley Lab's FLEXLAB test site, conducting multiple hardware-in-the-loop test runs. Here, we describe how DEGC was used to implement PBC on hardware, and results demonstrating successful deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of Probabilistic Forecasts for Predictive Voltage Control

This paper explores predictive cooperative voltage control in distribution systems with highly variable sources such as photovoltaics (PV). The goal is to maintain the voltage profile within the limits despite the fluctuations due to sudden changes in solar power generation. The predictive voltage control method relies on probabilistic solar power and load forecasts to select the optimum Voltage Regulator (VR) taps appropriately. VR taps are selected to minimize the risk of voltage violation. A modified version of the IEEE 123 system is used as the case study. A 100% penetration of solar power is assumed for the distribution system with profiles for solar generation and loads added to the system. Three different probabilistic forecast models (Quantile Regression (QR), Gaussian distribution and volatility forecasting using Generalized Autoregressive Conditional Heteroskedasticity (GARCH)) are explored in this study. The results for the VR taps and Voltage Deviation Index (VDI) are compared to find the most effective forecast model.

Panamtash, Hossein↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

The QICK (Quantum Instrumentation Control Kit): Readout and control for qubits and detectors

We introduce a Xilinx RF System-on-Chip (RFSoC)-based qubit controller (called the Quantum Instrumentation Control Kit, or QICK for short), which supports the direct synthesis of control pulses with carrier frequencies of up to 6 GHz. The QICK can control multiple qubits or other quantum devices. The QICK consists of a digital board hosting an RFSoC field-programmable gate array, custom firmware, and software and an optional companion custom-designed analog front-end board. We characterize the analog performance of the system as well as its digital latency, important for quantum error correction and feedback protocols. We benchmark the controller by performing standard characterizations of a transmon qubit. We achieve an average gate fidelity of ℱ avg =99.93%. All of the schematics, firmware, and software are open-source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wind plant wake losses: Disconnect between turbine actuation and control of plant wakes with engineering wake models

Wake losses from neighboring plants may become a major factor in wind plant design and control as additional plants are constructed in areas with high wind resource availability. Because plant wakes span a large range of physical scales, from turbine rotor diameter to tens of kilometers, it is unclear whether conventional wake models or turbine control strategies are effective at the plant scale. Wake steering and axial induction control are evaluated in the current work as means of reducing the impact of neighboring wind plants on power and levelized cost of electricity. FLOw Redirection and Induction in Steady State (FLORIS) simulations were performed with the Gauss–Curl Hybrid and TurbOPark wake models as well as two operation and maintenance models to investigate control setpoint sensitivity to wake representation and economic factors. Both wake models estimate losses across a range of atmospheric conditions, although the wake loss magnitude is dependent on the wake model. Annual energy production and levelized cost of electricity are driven by wind direction frequency, with frequently aligned plants experiencing the greatest losses. However, both wake steering and axial induction are unable to mitigate the impact of upstream plants. Wake steering is constrained by plant geometry, since wake displacement is much less than the plant wake width, while axial induction requires curtailing the majority of turbines in upstream plants. Individual turbine strategies are limited by their effective scale and model representation. New wake models that include plant-scale physics are needed to facilitate the design of effective plant wake control strategies.

Scott, Ryan (ORCID:0000000328107574)↗

Differentiable Predictive Control with Safety Guarantees: A Control Barrier Function Approach

In this paper, we develop a novel form of differentiable predictive control (DPC) with safety and robustness guarantees. DPC is a form of approximate model predictive control (MPC), wherein the control policy is a neural network that learns a receding horizon, optimal control law. The proposed approach exploits a new form of sampled-data barrier function to enforce safety, while only interrupting the neural network-based controller near the boundary of the safe set. The effectiveness of the proposed approach is demonstrated in simulation.

Shaw Cortez, Wenceslao E.↗

An Artificial-Intelligence and Machine-Learning-Based Methodology to Conduct Seemingly Strain-Controlled Fatigue Test in a Pressurized-Water-Reactor-Test-Loop-Autoclave, While Not Controlling the Strain

In general, low cycle fatigue analysis of pressurized water reactor (PWR) components, requires strain-controlled fatigue test data such as using strain versus life (ε–N) curves. Conducting strain-controlled fatigue tests under in-air conditions is not an issue. However, controlling strain in a PWR-test-loop-autoclave is a challenge, since an extensometer cannot be placed in a narrow autoclave (typically used in a high-temperature-pressure PWR-test-loop). This is due to lack of space inside an autoclave that houses the test specimen. In addition, installing a contact-type extensometer in the path of a high-pressure flow can be a challenge. These difficulties of using an extensometer inside an autoclave led us to use an outside-autoclave displacement sensor which measures the displacement of pull-rod-specimen assembly. However, in our study (based on in-air fatigue test data), we found that a pull-rod-controlled based fatigue test can lead to substantial cyclic hardening/softening resulting in substantially different cyclic strain amplitudes and their rates compared to the desired cyclic strain amplitudes and its rates. In this paper, we propose an Artificial-Intelligence and Machine-Learning based technique such as using k-means clustering technique to improve the pull-rod-control based fatigue test method, such that the gage-area strain amplitude and rates can reasonably be achieved. In support of this, we present the fatigue test results for both 316 SS base and 81/182 dissimilar-metal-weld specimens.

42 ENGINEERING↗

Area 6 Control Point: An Architectural Survey of the Area 6 Control Point, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) proposes to demolish five buildings and five accessory resources in the Area 6 Control Point at the Nevada National Security Site (NNSS) in Nye County, Nevada. The demolition and removal of the buildings and accessories constitute an undertaking subject to review under Section 106 of the National Historic Preservation Act (NHPA) (54 United States Code [USC] § 306101) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800. The buildings and accessories were recorded in Identification and Evaluation of 14 Architectural Resources Scheduled for Demolition, Area 6 Control Point and Vicinity, Nevada National Security Site, Nye County, Nevada (Menocal et al. 2020). The report found that the five buildings were not individually eligible for listing in the National Register of Historic Places (NRHP, National Register) but were potentially eligible as contributing elements to an unrecorded Area 6 Control Point district. The report also found that the five accessory resources were not individually eligible for the NRHP but they contributed to other historic properties, including the contributing elements to the unrecorded district. Finally, the report found that the undertaking would result in an adverse effect to historic properties. The State Historic Preservation Office (SHPO) concurred with the report’s findings regarding the eligibility of the buildings and structures in the Area of Potential Effect (APE) and that the undertaking would result in an adverse effect (Reed 2020). The NNSA/NFO, in consultation with the SHPO, then developed the Memorandum of Agreement DE-GM58-21NA25543 Between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Demolition of Fourteen Buildings and Structures in Area 6 of the Nevada National Security Site, Nye County, hereafter referred to as the MOA. The MOA stipulates that a district boundary be delineated with an accompanying boundary report and supporting photographs (Stipulation III.A) followed by an architectural survey of the potential historic district (Stipulation III.B). The SHPO reviewed and concurred with the proposed district boundary and accompanying boundary report and photographs (O’Neill et al. 2021) on August 23, 2021, in fulfillment of Stipulation III.A (Reed 2021). This architectural survey report has been prepared in accordance with Stipulation III.B. It includes an NRHP evaluation of the district, identifies contributing and non-contributing elements, and is accompanied by Architectural Resource Assessment (ARA) forms. The NRHP evaluation concludes that the Area 6 Control Point is recommended eligible as a historic district under the Secretary of the Interior’s Significance Criterion A at the national level as the location of the command center and various support facilities directly related to timing and firing operations for nuclear testing on the NNSS from 1951 to 1992. It is also recommended eligible under Significance Criterion C for embodying the distinctive characteristics of a nuclear command center in the context of the Cold War and as a significant and distinguishable entity. There are a total of 29 primary resources within the district boundary. Of these, 28 are recommended as contributing elements to the Area 6 Control Point Historic District and one is recommended as non-contributing.

54 ENVIRONMENTAL SCIENCES↗

Model predictive control of mixing controlled compression ignition operation for low reactivity fuels

Using gasoline or other low reactivity fuels with a pilot injection or port fuel injection in a compression ignition engine has shown great potential in reducing NOx emissions while keeping high thermal efficiency compared to diesel. However, excessive combustion noise is caused by a high maximum pressure rise rate in the cylinder due to the higher fractions of premixed charge of the low-reactivity fuel. This noise can result in structural damage to engine components and as such, combustion noise limits the range of the operating parameters and makes the control of such engines challenging. In this study, a simulation environment was built up in MATLAB/Simulink leveraging a physics-based zero-dimension combustion model to capture the in-cylinder pressure time traces as well as metrics relevant to thermal efficiency and combustion noise. Here, in order to also facilitate the control of emissions, machine learning models were investigated to capture NOx emissions. A kernel-based extreme learning machine (K-ELM) performed best and had a coefficient of correlation (R-squared) of 0.998. The combustion and NOx emission models are valid for not only conventional gasoline fuel but also oxygenated alternative fuel blends at three different pilot injection strategies. In order to track key combustion metrics while keeping noise and emissions within constraints, a model predictive control (MPC) was applied for a compression ignition engine operating with a range of potential fuels and fuel injection strategies. The MPC is validated under different scenarios, including a load step change, fuel type change, and injection strategy change, with proportional–integral (PI) control as the baseline. The simulation results show that MPC reduces about 26% of ringing intensity in the transient process and 17% at the steady state for E30. Generally, MPC can optimize the overall performance through modifying the main injection timing, pilot fuel mass, and exhaust gas recirculation (EGR) fraction.

42 ENGINEERING↗