Search NASA⌕ Search

SEARCH · Search NASA

Results for “COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

VLSI binary updown counter

A pipeline binary updown counter is comprised of simple stages that may be readily replicated. Each stage is defined by the Boolean logic equation: A(sub n)(t) = A(sub n)(t - 1) exclusive OR (U AND P(sub n)) inclusive OR (D AND Q(sub n)), where A(sub n)(t) denotes the value of the nth bit at time t. The input to the counter has three values represented by two binary signals U and D such that if both are zero, the input is zero, if U = 0 and D = 1, the input is -1 and if U = 1 and D = 0, the input is +1. P(sub n) represents a product of A(sub k)'s for 1 is less than or equal to k is less than or equal to -1, while Q(sub n) represents the product of bar A's for 1 is less than or equal to K is less than or equal to n - 1, where bar A(sub k) is the complement of A(sub k) and P(sub n) and Q(sub n) are expressed as the following two equations: P(sub n) = A(sub n - 1) A(sub n - 2)...A(sub 1) and Q(sub n) = bar A(sub n - 1) bar A(sub n - 2)...bar A(sub 1), which can be written in recursive form as P(sub n) = P(sub n - 1) AND bar A(sub n - 1) and Q(sub n) = Q(sub n - 1) AND bar A(sub n - 1) with the initial values P(sub 1) = 1 and Q(sub 1) = 1.

Truong, Trieu-Kie↗

The MSFC large-area imaging multistep proportional counter

A large-area multistep imaging proportional counter that is being currently developed at the Marshall Space Flight Center is described. The device, known as a multistep fluorescence gated detector, consists of a multiwire proportional counter (MWPC) with a preamplification region. The MWCP features superior spatial resolution with a very high degree of background rejection. It is ideally suited for use in X-ray astronomy in 20-100 keV energy range. The paper includes the MWPC schematic and a list of instrument specifications.

Ramsey, B. D.↗

An efficient hybrid scheme for the analysis of counter rotating propellers

An efficient solution procedure has been developed for analyzing inviscid unsteady flow past counter rotating propellers. This scheme is first order accurate in time and second order in space, and has been extended to fourth order accuracy in the axial direction. The solution procedure has been applied to a 2-bladed SR-7 single rotation propeller and to a GE F7/A7 counter rotation propeller. The pressure coefficients and the global quantities, power and thrust, show good comparison with experimental measurements.

Srivastava, R.↗

Multistep fluorescence gated proportional counters

A proportional counter is introduced in which the levels of energy and spatial resolutions and background rejection permit the application of the device to X-ray astronomy. A multistep approach is employed in which photons cause a signal that triggers the system and measures the energy of the incident photon. The multistep approach permits good energy resolution from parallel geometry and from the imaging stage due to coupling of the imaging and amplification stages. The design also employs fluorescence gating to reduce background, a method that is compatible with the multistep technique. Use of the proportional counter is reported for NASA's supernova campaign, and the pair background is below 0.0001 counts/sq cm sec keV at the xenon k-edge. Potential improvements and applications are listed including the CASES, POF, and EXOSS mission programs.

Ramsey, Brian D.↗

Uniformity and transmission of proportional counter window materials for use with AXAF

The X-ray detection system used to calibrate the Advanced X-ray Astrophysics Facility (AXAF) mirrors will include gas flow and sealed proportional counters. To meet the ultimate 1 percent goal of the calibration project, the transmission and uniformity of the windows must be well known for the soft X-ray wavelengths involved. Various window materials for use with proportional counters are examined for transmission at X-ray wavelengths in the range of 0.1 to 5.9 keV. These include the usual window materials (polypropylene and beryllium), as well as materials only recently employed for detector applications (polyimide and diamond). The transmission uniformity of beryllium at 1.49 keV is examined with a microchannel plate detector, producing a 'shadowgraph' of the window material illuminated with soft X-rays. This technique allows us to investigate nonuniformities on a spatial scale of about .2 mm.

Flanagan, K.↗

Experiments with a Counter-propeller

This note describes tests made at Stanford University on a four-blade fixed counter-propeller in combination with a two-blade rotating propeller. It is shown that the efficiency of the normal form, well-designed air propeller can be increased about two percent over the full working range by the addition of fixed counter-propeller blades.

Lesley, E P↗

Counter-propeller

A counter-propeller is a fixed propeller smaller than the main propeller, mounted either fore or aft of the latter and performing the function of changing the direction of motion of the fluid filaments, which naturally tend to adopt a helicoidal form. This paper presents a consideration of the real advantage of counter-propellers on aircraft and the best shape of the blades. First, the author determines the possible energy absorption by the tangential increments. This process will be facilitated by the examination of the polygons of the relative velocities fore and aft of the generic section, of radius r, of one of the blades of the propeller.

De Caria, Ugo↗

Planetary Camera imaging of the counter-rotating core galaxy NGC 4365

We analyze F555W(V) band Planetary Camera images of NGC 4365, for which ground-based spectroscopy has revealed a misaligned, counter-rotating core. Line profile analysis by Surma indicates that the counter-rotating component has a disk structure. After deconvolution and galaxy modeling, we find photometric evidence, at small radii to support this claim. There is no indication of a central point source or dust lane. The surface brightness profile reveals a steep outer profile and shallow, by not flat, inner profile with the inflection radius occurring at 1.8 sec. The inner profile is consistent with a cusp.

Forbes, Duncan A.↗

Breakdown Features of Various Microstrip-Type Gas Counter Designs and Their Improvements

Breakdown mechanisms and spurious pulses, the precursors to some breakdowns, were studied experimentally for both uncoated and coated Microstrip Gas Counters (MSGCs) of different geometries, as well as for MicroGap Counters (MGCs) and for the "Compteur A Trou" (CAT). It was found that in all cases the breakdowns occurred through surface streamers, although the exact mechanism of streamer formation depended on the particular detector design. Based on these studies, new designs of microstrip detectors, in which the role of the substrate was minimized, were elaborated and tested. In some of these detectors, especially with large pitches (greater than 2mm), gains up to 2-3 x 10(exp 5) were achieved together with good rate characteristics. The ultimate gain limit in all geometries was still set by spark-inducing streamers which appeared at some critical charge density in the avalanche. To avoid this, and particularly to enhance the performance of small-pitch MSGCs, preamplification structures can be used. Utilizing a parallel plate avalanche chamber as a front end to an MSGC resulted in an overall gain of approximately 10(exp 6), limited in this case only by charge saturation.

Peskov, V.↗

A Study of Breakdown Limits in Microstrip Gas Counters with Preamplification Structures

We have studied the charge and breakdown limits of Microstrip Gas Counters (MSGCs) with 2 different preamplification structures: the Gas Electron Multiplier (GEM) and the Parallel-Plate Avalanche Counter (PPAC). It was found that in both cases the breakdown limit was increased by 1-2 orders of magnitude compared to the bare MSGC that this is due to the spread of the primary electron cloud during pre-amplification. This spreading reduces the charge density in the final MSGC avalanche, permitting much higher total gains before streamers form. The real practical gain limitations in these two-stage detectors arose not from sparking, but from a loss of proportionality due to space charge effects.

Fonte, P.↗

Finding Feasible Abstract Counter-Examples

A strength of model checking is its ability to automate the detection of subtle system errors and produce traces that exhibit those errors. Given the high computational cost of model checking most researchers advocate the use of aggressive property-preserving abstractions. Unfortunately, the more aggressively a system is abstracted the more infeasible behavior it will have. Thus, while abstraction enables efficient model checking it also threatens the usefulness of model checking as a defect detection tool, since it may be difficult to determine whether a counter-example is feasible and hence worth developer time to analyze. We have explored several strategies for addressing this problem by extending an explicit-state model checker, Java PathFinder (JPF), to search for and analyze counter-examples in the presence of abstractions. We demonstrate that these techniques effectively preserve the defect detection ability of model checking in the presence of aggressive abstraction by applying them to check properties of several abstracted multi-threaded Java programs. These new capabilities are not specific to JPF and can be easily adapted to other model checking frameworks; we describe how this was done for the Bandera toolset.

Pasareanu, Corina S.↗

Observations of Counter-Streaming Ion Velocity Distributions in LLBL

We analyze ion velocity distributions observed by Interball-Tail at two LLBL crossings under southward and variable magnetosheath magnetic field. These magnetic conditions lead to highly structured LLBL. D-shape ion velocity distributions were observed within LLBL structures along with other reconnection signatures. Another type of the ion velocity distributions observed within LLBL structures consists of two counter-streaming magnetosheath-type components. We consider two possible scenarios that may lead to development of these counterstreaming ion components: reflection of transmitted magnetosheath ions from the ionosphere and creation of these velocity distributions during formation of the LLBL. We argue that observed counter-streaming component could not be due to ionospheric reflection. The observations of these ion velocity distributions are in favor of the multiple reconnections between magnetosheath and magnetospheric flux tubes.

Vaisberg, O. L.↗

Ocular Counter-Rolling During Centrifugation and Static Tilt

Activation of the gravity sensors in the inner ear-the otoliths-generates reflexes that act to maintain posture and gaze. Ocular counter-rolling (OCR) is an example of such a reflex. When the head is tilted to the side, the eyes rotate around the line of sight in the opposite direction (i.e., counter-rolling). While turning comers, undergoing centrifugation, or making side-to-side tilting head movements, the OCR reflex orients the eyes towards the sum of the accelerations from body movements and gravity. Deconditioning of otolith-mediated reflexes following adaptation to microgravity has been proposed as the basis of many of the postural, locomotor, and gaze control problems experienced by returning astronauts. Evidence suggests that OCR is reduced postflight in about 75% of astronauts tested; but the data are sparse, primarily due to difficulties in recording rotational eye movements. During the Neurolab mission, a short-arm human centrifuge was flown that generated sustained sideways accelerations of 0.5-G and one-G to the head and upper body. This produces OCR; and so for the first time, the responses to sustained centrifugation could be studied without the influence of Earth's gravity on the results. This allowed us to determine the relative importance of sideways and vertical acceleration in the generation of OCR. This also provided the first test of the effects of exposure to artificial gravity in space on postflight otolith-ocular reflexes. There was little difference between the responses to centrifugation in microgravity and on Earth. In both conditions, the induced OCR was roughly proportional to the applied acceleration, with the OCR magnitude during 0.5-G centrifugation approximately 60% of that generated during one-G centrifugation. The overall mean OCR from the four payload crewmembers in response to one-G of sideways acceleration was 5.7 plus or minus 1.1 degree (mean and SD) on Earth. Inflight one-G centrifugation generated 5.7 plus or minus 1.1 degree of OCR, which was a small but significant decrease in OCR magnitude. The postflight OCR was 5.9 plus or minus 1.4 degree, which was not significantly different from preflight values. During both 0.5-G and one-G centrifugation in microgravity, where the head vertical gravitational component was absent, the OCR magnitude was not significantly different from that produced by an equivalent acceleration during static tilt on Earth. This suggests that the larger OCR magnitude observed during centrifugation on Earth was due to the larger body vertical linear acceleration component, which may have activated either the otoliths or the body tilt receptors. In contrast to previous studies, there was no decrease in OCR gain postflight. Our findings raise the possibility that inflight exposure to artificial gravity, in the form of intermittent one-G and 0.5-G centripetal acceleration, may have been a countermeasure to deconditioning of otolith-based orientation reflexes.

Cohen, Bernard↗

X-ray Polarimetry with an Active-Matrix Pixel Proportional Counter

We report the first results from an X-ray polarimeter with a micropattern gas proportional counter using an amorphous silicon active matrix readout. With 100% polarized X-rays at 4.5 keV, we obtain a modulation factor of 0.33+/- 0.03, confirming previous reports of the high polarization sensitivity of a finely segmented pixel proportional counter. The detector described here has a geometry suitable for the focal plane of an astronomical X-ray telescope. Amorphous silicon readout technology will enable additional extensions and improvements.

Black, J. K.↗

Response of a tissue equivalent proportional counter to neutrons

The absorbed dose as a function of lineal energy was measured at the CERN-EC Reference-field Facility (CERF) using a 512-channel tissue equivalent proportional counter (TEPC), and neutron dose equivalent response evaluated. Although there are some differences, the measured dose equivalent is in agreement with that measured by the 16-channel HANDI tissue equivalent counter. Comparison of TEPC measurements with those made by a silicon solid-state detector for low linear energy transfer particles produced by the same beam, is presented. The measurements show that about 4% of dose equivalent is delivered by particles heavier than protons generated in the conducting tissue equivalent plastic. c2002 Elsevier Science Ltd. All rights reserved.

NASA Center JSC↗

Specimen block counter-staining for localization of GUS expression in transgenic arabidopsis and tobacco

A simple counter-staining procedure has been developed for comparative beta-glucuronidase (GUS) expression and anatomical localization in transgenic herbaceous arabidopsis and tobacco. This protocol provides good anatomical visualization for monitoring chimeric gene expression at both the organ and tissue levels. It can be used with different histochemical stains and can be extended to the study of woody species. The specimens are paraffin-embedded, the block is trimmed to reveal internal structure, safranin-O staining solution is briefly applied to the surface of the block, then washed off and, after drying, a drop of immersion oil is placed on the stained surface for subsequent photographic work. This gives tissue counter-staining with good structural preservation without loss of GUS staining product; moreover, sample observation is rapid and efficient compared to existing procedures.

NASA Discipline Plant Biology↗

IRAS 16293-2422: Evidence for Infall onto a Counter-Rotating Protostellar Accretion Disk

We report high spatial resolution VLA observations of the low-mass star-forming region IRAS 16293-2422 using four molecular probes: ethyl cyanide (CH3CH2CN)) methyl formate (CH3OCHO), formic acid (HCOOH), and the ground vibrational state of silicon monoxide (SiO). Ethyl cyanide emission has a spatial scale of approx. 20" and encompasses binary cores A and B as determined by continuum emission peaks. Surrounded by formic acid emission, methyl formate emission has a spatial scale of approx. 6" and is confined to core B. SiO emission shows two velocity components with spatial scales less than 2" that map approx. 2" northeast of the A and B symmetry axis. The redshifted SiO is approx. 2" northwest of blueshifted SiO along a position angle of approx. 135deg which is approximately parallel to the A and B symmetry axis. We interpret the spatial position offset in red and blueshifted SiO emission as due to rotation of a protostellar accretion disk and we derive approx. 1.4 Solar Mass, interior to the SiO emission. In the same vicinity, Mundy et al. (1986) also concluded rotation of a nearly edge-on disk from OVRO observations of much stronger and ubiquitous CO-13 emission but the direction of rotation is opposite to the SiO emission findings. Taken together, SiO and CO-13 data suggest evidence for a counter-rotating disk. Moreover, archival BIMA array CO-12C data show an inverse P Cygni profile with the strongest absorption in close proximity to the SiO emission, indicating unambiguous material infall toward the counter-rotating protostellar disk at a new source location within the IRAS 16293-2422 complex. The details of these observations and our interpretations are discussed.

Remijan, Anthony J.↗

THz Hot-Electron Photon Counter

We present a concept for the hot-electron transition-edge sensor capable of counting THz photons. The main need for such a sensor is a spectroscopy on future space telescopes where a background limited NEP approx. 10(exp -20) W/H(exp 1/2) is expected at around 1 THz. Under these conditions, the rate of photon arrival is very low and any currently imaginable detector with sufficient sensitivity will operate in the photon counting mode. The Hot-Electron Photon Counter based on a submicron-size Ti bridge has a very low heat capacity which provides a high enough energy resolution (approx.140 GHz) at 0.3 K. With the sensor time constant of a few microseconds, the dynamic range would be approx. 30 dB. The sensor couples to radiation via a planar antenna and is read by a SQUID amplifier or by a 1-bit RSFQ ADC. A compact array of the antenna-coupled counters can be fabricated on a silicon wafer without membranes.

radiation detectors↗