Search NASA⌕ Search

SEARCH · Search NASA

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Transition-Edge Sensor Pixel Parameter Design of the Microcalorimeter Array for the X-Ray Integral Field Unit on Athena

The focal plane of the X-ray integral field unit (X-IFU) for ESA's Athena X-ray observatory will consist of approximately 4000 transition edge sensor (TES) x-ray microcalorimeters optimized for the energy range of 0.2 to 12 kiloelectronvolts. The instrument will provide unprecedented spectral resolution of approximately 2.5 electronvolts at energies of up to 7 kiloelectronvolts and will accommodate photon fluxes of 1 milliCrab (90 counts per second) for point source observations. The baseline configuration is a uniform large pixel array (LPA) of 4.28 arcseconds pixels that is read out using frequency domain multiplexing (FDM). However, an alternative configuration under study incorporates an 18 by × 18 small pixel array (SPA) of 2 arcseconds pixels in the central approximately 36 arcseconds region. This hybrid array configuration could be designed to accommodate higher fluxes of up to 10 milliCrabs (900 counts per second) or alternately for improved spectral performance (less than 1.5 electronvolts) at low count-rates. In this paper we report on the TES pixel designs that are being optimized to meet these proposed LPA and SPA configurations. In particular we describe details of how important TES parameters are chosen to meet the specific mission criteria such as energy resolution, count-rate and quantum efficiency, and highlight performance trade-offs between designs. The basis of the pixel parameter selection is discussed in the context of existing TES arrays that are being developed for solar and x-ray astronomy applications. We describe the latest results on DC biased diagnostic arrays as well as large format kilo-pixel arrays and discuss the technical challenges associated with integrating different array types on to a single detector die.

Smith, S. J.↗

Lunar orbital gamma ray measurements from Apollo 15 and Apollo 16.

Examination of the data obtained by gamma-ray spectrometers on the Apollo 15 and Apollo 16 spacecraft has been carried out in part by summing up broad regions of the energy spectrum. The most instructive of these energy regions is 0.55 to 2.75 MeV, where the difference in count rates observed can be accounted for mainly by variations in the Th, U, and K content of the surface layers. The highest values are found in Mare Imbrium and Oceanus Procellarum, where a good deal of local variation is observed. By contrast, little increase is seen in the eastern maria surveyed compared with count rates in highland areas. The broad highland regions are low in radioactivity, but there is a measurable rise near the southernmost latitude on the far side. In addition to the radioactive lines, gamma-ray lines which can be ascribed to O, Si, Fe, Mg, and Al have been identified.

Arnold, J. R.↗

The soft X-ray turnoff of Nova Muscae 1983

Nova GQ Muscae 1983 was detected by ROSAT as a luminous 'supersoft' X-ray source in 1992, nearly a decade after outburst. Further, this is the only classical postnova known to have maintained constant luminosity on a timescale predicted by theoretical models. Follow-up observations were made with the ROSAT position-sensitive proportional counter in 1993 January and September, and complemented with B-band photometry taken in 1993 January. By 1993 January, the X-ray count rate had declined by a factor of 17, while there was neither an appreciable decrease in the optical magnitude nor a change in the amplitude of modulation. In 1993 September the soft X-ray flux was below the ROSAT threshold limit, implying a decrease of a factor greater than or equal to 30 in the count rate. This decline can be interpreted by the turnoff of nuclear processes due to the complete consumption of the residual hydrogen-rich envelope. However, the optical luminosity of the system is not simply coupled to the X-ray luminosity (e.g., through reprocessing).

Shanley, L.↗

Detector noise statistics in the non-linear regime

The statistical behavior of an idealized linear detector in the presence of threshold and saturation levels is examined. It is assumed that the noise is governed by the statistical fluctuations in the number of photons emitted by the source during an exposure. Since physical detectors cannot have infinite dynamic range, our model illustrates that all devices have non-linear regimes, particularly at high count rates. The primary effect is a decrease in the statistical variance about the mean signal due to a portion of the expected noise distribution being removed via clipping. Higher order statistical moments are also examined, in particular, skewness and kurtosis. In principle, the expected distortion in the detector noise characteristics can be calibrated using flatfield observations with count rates matched to the observations. For this purpose, some basic statistical methods that utilize Fourier analysis techniques are described.

Shopbell, P. L.↗

Calculations for Calibration of a Mass Spectrometer

A computer program performs calculations to calibrate a quadrupole mass spectrometer in an instrumentation system for identifying trace amounts of organic chemicals in air. In the operation of the mass spectrometer, the mass-to-charge ratio (m/z) of ions being counted at a given instant of time is a function of the instantaneous value of a repeating ramp voltage waveform applied to electrodes. The count rate as a function of time can be converted to an m/z spectrum (equivalent to a mass spectrum for singly charged ions), provided that a calibration of m/z is available. The present computer program can perform the calibration in either or both of two ways: (1) Following a data-based approach, it can utilize the count-rate peaks and the times thereof measured when fed with air containing known organic compounds. (2) It can utilize a theoretical proportionality between the instantaneous m/z and the instantaneous value of an oscillating applied voltage. The program can also estimate the error of the calibration performed by the data-based approach. If calibrations are performed in both ways, then the results can be compared to obtain further estimates of errors.

Lee, Seungwon↗

Particle emission from artificial cometary materials

During KOSI (comet simulation) experiments, mineral-ice mixtures are observed in simulated space conditions. Emission of ice-/dust particles from the sample surface is observed by means of different devices. The particle trajectories are recorded with a video system. In the following analysis we extracted the parameters: particle count rate, spatial distribution of starting points on the sample surface, and elevation angle and particle velocity at distances up to 5 cm from the sample surface. Different kinds of detectors are mounted on a frame in front of the sample to register the emitted particles and to collect their dust residues. By means of these instruments the particle count rates, the particle sizes and the composition of the particles can be correlated. The results are related to the gas flux density and the temperature on the sample surface during the insolation period. The particle emission is interpreted in terms of phenomena on the sample surface, e.g., formation of a dust mantle.

Koelzer, Gabriele↗

Threshold effects on V/V(max) for gamma-ray bursts

The interpretation of the observed gamma-ray burst V/V(max) statistic in terms of spatial distributions is model-dependent. Detection of gamma-ray bursts requires the counting rate in one or more detectors to exceed a threshold C(lim) determined from a time-dependent background rate B(t). The sampling depth of the burst detector is thus time-dependent, and, if burst sources are nonuniform in space, the observed V/V(max) distribution will be affected by B(t). We demonstrate this effect with a simple geometric distribution of standard candles and argue that V/V(max) statistic without information on threshold variations is insufficient for rigorous data analysis. Peak count rates and threshold values must be given separately for all events in order to facilitate a meaningful comparison of observations with theoretical distribution models.

Hartmann, D. H.↗

ROSAT Observations of Solar Wind Charge Exchange with the Lunar Exosphere

We analyze the ROSAT PSPC soft X-ray image of the Moon taken on 29 June 1990 by examining the radial profile of the count rate in three wedges, two wedges (one north and one south) 13-32 degrees off (19 degrees wide) the terminator towards the dark side and one wedge 38 degrees wide centered on the anti-solar direction. The radial profiles of both the north and the south wedges show substantial limb brightening that is absent in the 38 degree wide antisolar wedge. An analysis of the count rate increase associated with the limb brightening shows that its magnitude is consistent with that expected due to solar wind charge exchange (SWCX) with the tenuous lunar atmosphere. Along with Mars, Venus, and Earth, the Moon represents another solar system body at which solar wind charge exchange has been observed. This technique can be used to explore the solar wind-lunar interaction.

Collier, Michael R.↗

The Athena X-ray Integral Field Unit (X-IFU)

The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for High-ENergy Astrophysics (Athena) will provide spatially resolved high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 pixels over a field of view of 5 arc minute equivalent diameter and a spectral resolution of 2.5 eV up to 7 keV. In this paper, we first review the core scientific objectives of Athena, driving the main performance parameters of the X-IFU, namely the spectral resolution, the field of view, the effective area, the count rate capabilities, the instrumental background. We also illustrate the breakthrough potential of the X-IFU for some observatory science goals. Then we brie y describe the X-IFU design as defined at the time of the mission consolidation review concluded in May 2016, and report on its predicted performance. Finally, we discuss some options to improve the instrument performance while not increasing its complexity and resource demands (e.g. count rate capability, spectral resolution). (2016) .

Space telescopes↗

EUV emission from a sample of Active Galactic Nuclei

Active Galactic Nuclei (AGN) emit a substantial fraction of their total radiated power in the EUV passband, because spectroscopically this band is situated at or near the peak of the 'big blue bump,' which is bounded on either side by the UV and soft X-ray excesses. Owing to the lack of observational data, the shape of AGN spectra in the EUV is not well known. This paper presents broad band (65-190 eV) count rates of 11 AGN detected by the Extreme Ultraviolet Explorer (EUVE). Assuming a power law spectral shape for the EUV and soft X-ray energies, we demonstrate that the photon indices of the sources are considerably steeper than typical AGN indices. For 6 sources where ROSAT data are available to provide a more precise determination of their spectral parameters in the 0.1-2.5 keV range, we have used these parameters to compute predicted EUVE count rates and compared them with the observed values. The two sets of quantities agree to within experimental error. We conclude that there is no evidence of spectral steepening or turn-over of the soft X-ray excess at EUV wavelengths for a sample of AGN which covers a wide range of brightness.

Lieu, R.↗

High-dynamic-range MCP structures

We report on the development of a new high-dynamic-range two-stage Multi-Anode Microchannel Array (MAMA) imaging tube designed for improved high count rate performance at FUV and EUV wavelengths. The new two-stage MAMA tube employs two 25-mm-diameter format MCPs placed in tandem with a small gap between the plates. The front (input) MCP is designed to be a low-gain converter plate that supports an opaque photocathode and converts the detected photons to electrons, while the second (output) MCP is of higher conductivity and thus maintains the overall gain of the multiplier at high count rates. The second MCP is mounted in proximity focus with a (224 x 960)-pixel fine-fine coincidence MAMA array for high-spatial-resolution imaging studies. The applied voltage across each MCP can be controlled independently. We report on the gain and dynamic range performance characteristics of the two-stage MAMA tube in two different configurations: first, with the output MCP having moderate conductivity (about 100 MOhm); and second, with the output MCP having very high conductivity (about 2 MOhm). These results are compared and contrasted with those of the more conventional MAMA tube configuration which employs a single high-gain curved-channel MCP.

Slater, David C.↗

Neutron and electromagnetic emissions during the 1990 May 24 solar flare

In this paper, we are primarily concerened with the solar neutron emission during the 1990 May 24 flare, utilizing the counting rate of the Climax neutron monitor and the time profiles of hard X-rays and gamma-rays obtained with the GRANAT satellite (Pelaez et al., 1992; Talon et al., 1993; Terekhov et al., 1993). We compare the derived neutron injection function with macroscopic parameters of the flare region as obtained from the H-alpha and microwave observations made at the Big Bear Solar Observatory (BBSO) and the Owens Valley Radio Observatory (OVRO) respectively. Our results are summarized as folows: (1) to explain the neutron monitor counting rate and 57.5-110 MeV and 2.2 MeV gamma-ray time profiles, we consider a two-component neutron injection function, Q(E, t). (2) From the H-alpha observations, we find a relatively small loop of length approximattely equal to 2 x 10(exp 4) km, which may be regarded as the source for the fast-decaying component of gamma-rays (57.5-110 MeV) and for the first component of neutron emission. From microwave visibility and the microwave total power spectrum we postulate the presence of a rather big loop (approximately equal to 2 x 10(exp 5) km), which we regard as being responsible for the slow-decaying component of the high-energy emission. We show how the neutron and gamma-ray emission data can be explained in terms of the macroscopic parameters derived from the H-alpha and microwave observations. (3) The H-alpha observations also reveal the presence of a fast mode MHD shock (the Moreton wave) which precedes the microwave peak by 20-30 s and the peak of gamma-ray intensity by 40-50 s. From this relative timing and the single-pulsed time profiles of both radiations, we can attribute the whole event as due to a prompt acceleration of both electrons and protons by the shock and subsequent deceleration of the trapped particles while they propagate inside the magnetic loops.

Kocharov, L. G.↗

Advances in Small Pixel TES-Based X-Ray Microcalorimeter Arrays for Solar Physics and Astrophysics

We are developing small-pixel transition-edge-sensor (TES) for solar physics and astrophysics applications. These large format close-packed arrays are fabricated on solid silicon substrates and are designed to accommodate count-rates of up to a few hundred counts/pixel/second at a FWHM energy resolution approximately 2 eV at 6 keV. We have fabricated versions that utilize narrow-line planar and stripline wiring. We present measurements of the performance and uniformity of kilo-pixel arrays, incorporating TESs with single 65-micron absorbers on a 7s-micron pitch, as well as versions with more than one absorber attached to the TES, 4-absorber and 9-absorber "Hydras". We have also fabricated a version of this detector optimized for lower energies and lower count-rate applications. These devices have a lower superconducting transition temperature and are operated just above the 40mK heat sink temperature. This results in a lower heat capacity and low thermal conductance to the heat sink. With individual single pixels of this type we have achieved a FWHM energy resolution of 0.9 eV with 1.5 keV Al K x-rays, to our knowledge the first x-ray microcalorimeter with sub-eV energy resolution. The 4-absorber and 9-absorber versions of this type achieved FWHM energy resolutions of 1.4 eV and 2.1 eV at 1.5 keV respectively. We will discuss the application of these devices for new astrophysics mission concepts.

Bandler, S. R.↗

In-situ observations of a bi-modal ion distribution in the outer coma of comet P/Halley

Observations obtained by the Johnstone Plasma Analyzer on the Giotto fly-by of comet Halley showed a fairly sudden decrease in the count rate of energetic (about 30 KeV) water-group ions inside about 500,000 km from the nucleus. This decrease was accompanied by the appearance of a new water-group ion population at slightly lower energies (less than 10 KeV). Close inspection reveals that this lower-energy peak was also present somewhat earlier in the postshock flow but only became prominent near the sudden transition just described. It is shown that the observed bimodal ion distribution is well explained in terms of the velocity history of the accreting solar wind flow in the outer coma. The decline in count rate of the energetic pick-up distribution is due to a relatively sudden slowing of the bulk flow there and not to a loss of particles. Hence, charge-exchange cooling of the flow is probably not important at these distances from the nucleus. The observations suggest that pitch-angle scattering is fairly efficient at least after the bow shock, but that energy diffusion is probably not very efficient.

Thomsen, M. F.↗

On the Nature of the mHz X-ray Quasi-Periodic Oscillations from Ultraluminous X-ray source M82 X−1: Search for Timing-Spectral Correlations

Using all the archival XMM-Newton X-ray (3-10 keV) observations of the ultraluminous X-ray source (ULX) M82 X−1, we searched for a correlation between its variable mHz quasi-periodic oscillation (QPO) frequency and its hardness ratio (5-10 keV/3-5 keV), an indicator of the energy spectral power-law index. When stellar-mass black holes (StMBHs) exhibit type-C low-frequency QPOs (∼0.2-15 Hz), the centroid frequency of the QPO is known to correlate with the energy spectral index. The detection of such a correlation would strengthen the identification of M82 X−1's mHz QPOs as type-C and enable a more reliable mass estimate by scaling its QPO frequencies to those of type-C QPOs in StMBHs of known mass.We resolved the count rates and the hardness ratios of M82 X−1 and a nearby bright ULX (source 5/X42.3+59) through surface brightness modeling.We detected QPOs in the frequency range of 36-210 mHz during which M82 X−1's hardness ratio varied from 0.42 to 0.47. Our primary results are (1) that we do not detect any correlation between the mHz QPO frequency and the hardness ratio (a substitute for the energy spectral power-law index) and (2) similar to some accreting X-ray binaries, we find that M82 X−1's mHz QPO frequency increases with its X-ray count rate (Pearson's correlation coefficient = +0.97). The apparent lack of a correlation between the QPO centroid frequency and the hardness ratio poses a challenge to the earlier claims that the mHz QPOs of M82 X−1 are the analogs of the type-C low-frequency QPOs of StMBHs. On the other hand, it is possible that the observed relation between the hardness ratio and the QPO frequency represents the saturated portion of the correlation seen in type-C QPOs of StMBHs-in which case M82 X−1's mHz QPOs can still be analogous to type-C QPOs.

Nature↗

Radiation Tests of Single Photon Avalanche Diode for Space Applications

Single photon avalanche diodes (SPADs) have been recently studied as photodetectors for applications in space missions. In this presentation we report the results of radiation hardness test on large area SPAD (actual results refer to SPADs having 500 micron diameter). Dark counts rate as low as few kHz at −10 degC has been obtained for the 500 micron devices, before irradiation. We performed bulk damage and total dose radiation tests with protons and gamma-rays in order to evaluate their radiation hardness properties and their suitability for application in a Low Earth Orbit (LEO) space mission. With this aim SPAD devices have been irradiated using up to 20 krad total dose with gamma-rays and 5 krad with protons. The test performed show that large area SPADs are very sensitive to proton doses as low as 2×10(exp 8) (1 MeV eq) n/cm2 with a significant increase in dark counts rate (DCR) as well as in the manifestation of the "random telegraph signal" effect. Annealing studies at room temperature (RT) and at 80 degC have been carried out, showing a high decrease of DCR after 24-48 h at RT. Lower protons doses in the range 1-10×10(exp 7) (1 MeV eq) n/cm(exp 2) result in a lower increase of DCR suggesting that the large-area SPADs tested in this study are well suitable for application in low-inclination LEO, particularly useful for gamma-ray astrophysics.

radiation hardness↗

A component of nongyrotropic (phase-bunched) electrons upstream from the earth's bow shock

The count rates of 1.5- and 6-keV electrons measured on ISEE 1 and ISEE 2 are at times strongly spin modulated despite the fact that the axes of the detectors lie along the spin axis of the spacecraft. Spatial gradients in the guiding center density are ruled out as a cause of the spin modulation. The characteristics of the spin modulation can be explained if the electron velocity distribution is nongyrotropic. The procedure is to show that the direction of the plasma flow velocity during times of spin modulation does not lie along the direction of the local magnetic field when both are projected onto the ecliptic plane. While a gyrotropic distribution will cause spin modulation, the count rate maximum will correspond to the direction of the local magnetic field. Gyrophase-bunched electrons are seen within a few tens of kilometers of the shock and as far upstream as 30,000 km from the shock, suggesting that a wave is associated with their propagation. The magnetosheath electrons in the same energy range are also nongyrotropic at times.

Anderson, K. A.↗

Fundamental Equations of the LIF Hydroxyl Measurements, Appendix a

The equation relating OH concentration to the observed detector count rate for a given laser flux is defined. That equation, which will be referred to henceforth as the central equation for absolute sensitivity, will be cast in terms of standard spectroscopic quantities such as oscillator strengths, Hoenl-London factors, rotational and vibrational quantum numbers, etc., such that it may be tested directly under laboratory conditions. The working expressions used by each of the OH laser induced fluorescence (LIF) groups will be related to this central equation, thereby establishing a common language for the comparison of experimental results and the definition of LIF system performance. The relevant structural details of the OH radical via a spectroscopic description of the energy levels and transitions employed in the LIF method are detailed. The central equation relating observed count rate to absolute concentration will be derived, and that equation will be related to the observed quantities cited by each of the experimental groups engaged in the measurement of OH in the Earth's atmosphere.

Source record↗