Search NASA⌕ Search

SEARCH · Search NASA

Results for “CT images”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Topological analysis of X-ray CT data for the recognition and trending of subtle changes in microstructure under material aging

X-ray computed tomography (CT) is an established non-destructive tool for 3D imaging of multiphasic composites. Numerous applications of X-ray CT in medical diagnosis and materials characterization have been reported, many involving field-specific innovations in the imaging technology itself. Yet, quantitative summarization to link image features to properties of interest has been rare. Here we address this issue by employing state-of-the-art technics in scalar field topology for the summarization of X-ray CT images of an example biphasic system. By varying processing-parameters we create different microstructures, evolve them through accelerated thermal aging, CT-image them pre- and post-aged, and demonstrate the ability of our image summarization method to systematically track process- and age-related changes, which can often be very subtle. A novel aspect of the algorithm involves recognition over multiple resolution levels, which provides deeper insight into the pattern relationship between grain-like features and their neighbors. The method is general, adaptable to diverse image reconstruction methods and materials systems, and particularly useful in applications where practical constraints on the sample-size limits the reliable use of more complex models, e.g., convolutional neural networks.

36 MATERIALS SCIENCE↗

Different CT slice thickness and contrast‐enhancement phase in radiomics models on the differential performance of lung adenocarcinoma

Abstract Background To investigate the effects of computed tomography (CT) reconstruction slice thickness and contrast‐enhancement phase on the differential diagnosis performance of radiomic signature in lung adenocarcinoma. Methods A total of 187 patients who had been pathologically confirmed with lung adenocarcinoma and nonadenocarcinoma were divided into a training cohort ( n = 149) and validation cohort ( n = 38). All the patients underwent contrast‐enhanced CT and the images were reconstructed with different slice thickness. The radiomic features were extracted from different slice thickness and scan phase. The logistic regression (LR) algorithm was used to build a machine learning model for each group. The area under the curve (AUC) obtained from the receiver operating characteristic (ROC) curve and DeLong test was used to evaluate its discriminating performance. Results Finally, 34 image features and five semantic features were selected to establish a radiomics model. Based on the three contrast‐enhanced CT phases and four reconstruction slice thickness, 12 groups of radiomics models showed good discrimination ability with the AUCs range from 0.9287 to 0.9631, sensitivity range from 0.8349 to 0.9083, specificity range from 0.825 to 0.925 in the training group. Similar results were observed in the validation group. However, there was no statistical significance between the different CT scan phase groups and different slice thickness ( p > 0.05). Conclusions The radiomic analysis of contrast‐enhanced CT can be used for the differential diagnosis of lung adenocarcinoma. Moreover, different slice thickness and contrast‐enhanced scan phase did not affect the discriminating ability in the radiomics models.

Wang, Yang↗

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Influence of Data Acquisition Algorithms on X-ray Phase Contrast Imaging Computed Tomography

X-ray phase contrast imaging (XPCI) is a non-destructive evaluation technique that enables high-contrast detection of low-attenuation materials that are largely transparent in traditional radiography. Extending a grating based Talbot-Lau XPCI system to three- dimensional imaging with computed tomography (CT) imposes two motion requirements: the analyzer grating must translate transverse to the optical axis to capture image sets for XPCI reconstruction, and the sample must rotate to capture angular data for CT reconstruction. The acquisition algorithm choice determines the order of movement and positioning of the two stages. The choice of image acquisition algorithm for XPCI CT is instrumental to collecting high fidelity data for reconstruction. We investigate how data acquisition influences XPCI CT by comparing two simple data acquisition algorithms and determine that capturing a full phase-stepping image set for a CT projection before rotating the sample results in higher quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasparse View X-ray Computed Tomography for 4D Imaging

X-ray computed tomography (CT) is a noninvasive, nondestructive approach to imaging materials, material systems, and engineered components in two and three dimensions. Acquisition of three-dimensional (3D) images requires the collection of hundreds or thousands of through-thickness X-ray radiographic images from different angles. Such 3D data acquisition strategies commonly involve suboptimal temporal sampling for in situ and operando studies (4D imaging). Herein, we introduce a sparse-view imaging approach, Tomo-NeRF, which is capable of reconstructing high-fidelity 3D images from <10 twodimensional radiographic images. Experimental 2D and 3D X-ray images were used to test the reconstruction capability in two-view, four-view, and six-view scenarios. Tomo-NeRF is capable of reconstructing 3D images with a structural similarity of 0.9971–0.9975 and a voxel-wise accuracy of 81.83–89.59% from 2D experimentally obtained images. Furthermore, the reconstruction accuracy for the experimentally obtained images is less than the synthetic structures. Experimentally obtained images demonstrate a similarity of 0.9973–0.9984 and a voxelwise accuracy of 84.31–95.77%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bridging Nano- and Microscale X-Ray Tomography for Battery Research by Leveraging Artificial Intelligence

X-ray computed tomography (CT) is a non-destructive imaging technique in which contrast originates from the materials' absorption coefficient. The recent development of laboratory nanoscale CT (nano-CT) systems has pushed the spatial resolution for battery material imaging to voxel sizes of 50 nm, a limit previously achievable only with synchrotron facilities. Given the non-destructive nature of CT, in situ and operando studies have emerged as powerful methods to quantify morphological parameters, such as tortuosity factor, porosity, surface area and volume expansion, during battery operation or cycling. Combined with artificial intelligence and machine learning analysis techniques, nano-CT has enabled the development of predictive models to analyse the impact of the electrode microstructure on cell performances or the influence of material heterogeneities on electrochemical responses. In this Review, we discuss the role of X-ray CT and nano-CT experimentation in the battery field, discuss the incorporation of artificial intelligence and machine learning analyses and provide a perspective on how the combination of multiscale CT imaging techniques can expand the development of predictive multiscale battery behavioural models.

diagnostics↗

In situ laser profilometry for material segmentation and digital reconstruction of a multicomponent additively manufactured part

In addition to its ability to produce geometrically complex parts, additive manufacturing offers a unique opportunity to collect data about a component while it is being fabricated. However, there has only been limited effort to characterize parts morphologically and compositionally in situ. In this article, we present a layer-by-layer, laser profilometry-based in situ characterization technique as a method to digitally reconstruct a multi-material part. Data collected by the laser profilometer yields height maps and grayscale images which are voxelized using purpose-built software to volumetrically reconstruct the part. Additionally, the same part was also analyzed using X-ray computed tomography (CT) which was not able to resolve the different compositional regions within the part, but captured the filament morphology. The part was then bisected to compare the digital reconstruction to the actual part morphology and composition. Overall, the digital reconstruction was in good agreement with both the CT and bisected images. Deviations between the digital reconstruction and the CT/bisected images are likely the result of image segmentation settings or material shifts after data was collected. The in situ characterization method demonstrated here sets the stage for real time process monitoring and paves the way for additively manufactured parts that are “born qualified.”

36 MATERIALS SCIENCE↗

Imaging APO-BMI with Micro X-ray Computed Tomography (CT)

APO-BMI is a high-strength, high-temperature, and low-density foam comprised of 1,2-bis(2-aminophenylthio) ethane (APO-Link, formerly Apocure-601) and 4,4’-bismaleimidodiphenylmethane (BMI) that is used structural applications within the aerospace and weapons manufacturing sectors. APO-link is the diamine reagent used to synthesize BMI, a thermosetting resin. This resin can remain in a molten, flowing state for an extended period of time before crosslinking, allowing addition of glass or carbon microballoons to form its final structure. A portion of the current project was to observe the thermal effects on the structural integrity of the foam associated with exposure to an ion beam. Features within the foam were imaged using micro X-ray computed tomography (CT). The resulting imaging provided evidence that microballoon structure remained mostly intact at the points of failure, indicating that the failure of the material was occurring in the binder material.

36 MATERIALS SCIENCE↗

Black-box optimization of CT acquisition and reconstruction parameters: a reinforcement learning approach

Protocol optimization is critical in Computed Tomography (CT) for achieving desired diagnostic image quality while minimizing radiation dose. Due to the inter-effect of influencing CT parameters, traditional optimization methods rely on the testing of exhaustive combinations of these parameters. This poses a notable limitation due to the impracticality of exhaustive parameter testing. This study introduces a novel methodology leveraging Virtual Imaging Trials (VITs) and reinforcement learning to more efficiently optimize CT protocols. Computational phantoms with liver lesions were imaged using a validated CT simulator and reconstructed with a novel CT reconstruction Toolkit. The optimization parameter space included tube voltage, tube current, reconstruction kernel, slice thickness, and pixel size. The optimization process was done using a Proximal Policy Optimization (PPO) agent which was trained to maximize the Detectability Index (d’) of the liver lesion for each reconstructed image. Results showed that our reinforcement learning approach found the absolute maximum d’ across the test cases while requiring 79.7% fewer steps compared to an exhaustive search, demonstrating both accuracy and computational efficiency, offering a efficient and robust framework for CT protocol optimization. The flexibility of the proposed technique allows for use of varying image quality metrics as the objective metric to maximize for. Our findings highlight the advantages of combining VIT and reinforcement learning for CT protocol management.

Fenwick, David [Duke University Medical Center]↗

Characterization of damage processes in Montney siltstone under triaxial compression using acoustic emission and diagnostic imaging

SUMMARY Crack nucleation and rock failure processes in a fine-grained siltstone (Montney Formation) under triaxial compression are investigated using combined diagnostic techniques, including ultrasonic-wave measurement, acoustic-emission (AE) monitoring, computed tomography (CT) scanning, and thin-section imaging. The sample displays a weak-to-moderate inherent seismic anisotropy and noticeable stress-induced anisotropy prior to failure. No AE event was detected until the applied axial stress reached 95 per cent of the peak value. The signal-to-noise ratio is relatively low, however, and detectable AE events are more diffuse than those observed in highly brittle rocks. The AE locations correlate with a shear fracture zone imaged by CT scanning. AE moment-tensor analysis reveals that events with larger relative magnitudes are characterized by high volumetric (tensile or compressive) components, and the initiation of the failure zone is dominated by combined shear-tensile (ST) failure. Stress inversion of the AE events with high tensile components is in good agreement with the known applied stress. Microscopic imaging of thin sections from the failed sample shows that the failure zone is an en echelon structure consisting of a major fracture with branching micro and minor cracks. This failure mechanism is consistent with a ST source mechanism and is interpreted to be associated with the fine granular structure and mineral composition of Montney siltstone.

Jia, Suzie Q. (ORCID:0000000326496190)↗

Frequency shifts in the electron paramagnetic resonance spectrum of 39 K due to spin-exchange collisions with polarized 3 He and precise 3 He polarimetry

The Zeeman splittings and electron paramagnetic resonance frequencies of alkali-metal atoms are shifted in the presence of a polarized noble gas. For a spherical geometry, the shift is enhanced over what is expected classically by a dimensionless atomic parameter 𝜅 0 that is unique to each alkali-metal-atom–noble-gas pair. Here, we present a precise measurement of 𝜅 0 for the 39 K − 3 He system with a relative accuracy of better than 1%. A critical component of achieving subpercent accuracy involved characterizing the shape of our samples using both MRI and CT medical-imaging techniques. The parameter 𝜅 0 plays an important role in establishing the absolute polarization of 3 He in a variety of contexts, including polarized targets for electron-scattering experiments and MRI of the gas space of the lungs. Our measurement more than doubles the accuracy possible when using 𝜅 0 for polarimetry purposes. Just as important, the work presented here represents a direct measurement of 𝜅 0 for the 39 K − 3 He system; previous values for 𝜅 0 in the 39 K − 3 He system relied on a chain of measurements that were benchmarked by previous measurements of 𝜅 0 in the Rb- 3 He system.

Zeeman effect↗

Physics‐based iterative reconstruction for dual‐source and flying focal spot computed tomography

Purpose For single‐source helical Computed Tomography (CT), both Filtered‐Back Projection (FBP) and statistical iterative reconstruction have been investigated. However, for dual‐source CT with flying focal spot (DS‐FFS CT), a statistical iterative reconstruction that accurately models the scanner geometry and acquisition physics remains unknown to researchers. Therefore, our purpose is to present a novel physics‐based iterative reconstruction method for DS‐FFS CT and assess its image quality. Methods Our algorithm uses precise physics models to reconstruct from the native cone‐beam geometry and interleaved dual‐source helical trajectory of a DS‐FFS CT. To do so, we construct a noise physics model to represent data acquisition noise and a prior image model to represent image noise and texture. In addition, we design forward system models to compute the locations of deflected focal spots, the dimension, and sensitivity of voxels and detector units, as well as the length of intersection between x‐rays and voxels. The forward system models further represent the coordinated movement between the dual sources by computing their x‐ray coverage gaps and overlaps at an arbitrary helical pitch. With the above models, we reconstruct images by an advanced Consensus Equilibrium (CE) numerical method to compute the maximum a posteriori estimate to a joint optimization problem that simultaneously fits all models. Results We compared our reconstruction with Siemens ADMIRE, which is the clinical standard hybrid iterative reconstruction (IR) method for DS‐FFS CT, in terms of spatial resolution, noise profile, and image artifacts through both phantoms and clinical scan datasets. Experiments show that our reconstruction has a higher spatial resolution, with a Task‐Based Modulation Transfer Function (MTF task ) consistently higher than the clinical standard hybrid IR. In addition, our reconstruction shows a reduced magnitude of image undersampling artifacts than the clinical standard. Conclusions By modeling a precise geometry and avoiding data rebinning or interpolation, our physics‐based reconstruction achieves a higher spatial resolution and fewer image artifacts with smaller magnitude than the clinical standard hybrid IR.

Wang, Xiao↗

The Next Generation of MeV Energy X-ray Sources for Use in the Inspection of Additively Manufactured Parts for Industry

In September 2022, we investigated whether we can change the way we perform non-destructive characterization (NDC) of dense, micrometer-scale objects, e.g., additively manufactured (AM) parts, using the BELLA inverse Compton source (ICS). X-ray computed tomography (CT) is the most suitable technique for NDC of these objects, but often requires x-rays with MeV energy for penetration, sub-mm spatial resolution for small structures, a narrow spectrum for low-artifact images, and the ability to tune x ray energy to image a wide range of materials. The BELLA ICS has the unique potential to produce such an x-ray beam with a repetition rate high enough for CT. We scanned a geometric calibration phantom, fabricated by LLNL, a bearing, and an AM part manufactured by Renishaw. We reconstructed the first CT images of their kind. The results are very promising, and LLNL will present our findings at an SPIE conference.

42 ENGINEERING↗

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pore-scale observations of natural hydrate-bearing sediments via pressure core sub-coring and micro-CT scanning

Abstract Both intra-pore hydrate morphology and inter-pore hydrate distribution influence the physical properties of hydrate-bearing sediments, yet there has been no pore-scale observations of hydrate habit under pressure in preserved pressure core samples so far. We present for the first time a pore-scale micro-CT study of natural hydrate-bearing cores that were acquired from Green Canyon Block 955 in UT-GOM2-1 Expedition and preserved within hydrate pressure–temperature stability conditions throughout sub-sampling and imaging processes. Measured hydrate saturation in the sub-samples, taken from units expected to have in-situ saturation of 80% or more, ranges from 3 ± 1% to 56 ± 11% as interpreted from micro-CT images. Pore-scale observations of gas hydrate in the sub-samples suggest that hydrate in silty sediments at the Gulf of Mexico is pore-invasive rather than particle displacive, and hydrate particles in these natural water-saturated samples are pore-filling with no evidence of grain-coating. Hydrate can form a connected 3D network and provide mechanical support for the sediments even without cementation. The technical breakthrough to directly visualize particle-level hydrate pore habits in natural sediments reported here sheds light on future investigations of pressure- and temperature-sensitive processes including hydrate-bearing sediments, dissolved gases, and other biochemical processes in the deep-sea environment.

58 GEOSCIENCES↗

Three-dimensional high-content imaging of unstained soft tissue with subcellular resolution using a laboratory-based X-ray microscope

With increasing interest in studying biological systems across spatial scales—from centimeters down to nanometers—histology continues to be the gold standard for tissue imaging at cellular resolution, providing an essential bridge between macroscopic and nanoscopic analysis. However, its inherently destructive and two-dimensional nature limits its ability to capture the full three-dimensional complexity of tissue architecture. Here, we show that phase-contrast X-ray microscopy can enable three-dimensional virtual histology with subcellular resolution. This technique provides direct quantification of electron density without restrictive assumptions, allowing for direct characterization of cellular nuclei in a standard laboratory setting. By combining high spatial resolution and soft tissue contrast, with automated segmentation of cell nuclei, we demonstrated virtual Hematoxylin and Eosin (H&E) staining using machine learning-based style transfer, yielding volumetric datasets compatible with existing histopathological analysis tools. Furthermore, by integrating electron density and the sensitivity to nanometric features of the dark field contrast channel, we achieve stain-free, high-content imaging capable of distinguishing nuclei and extracellular matrix.

3D virtual histology↗

Deep Learning Model Segmentations on Computed Tomography 3D Reconstructions of Coffee Beans to Determine Void Ratio (U-Net) and Roast Level (LinkNet)

This project will evaluate the functionality of Object Research Dragonfly software’s user produced deep learning (DL) models on Computed Tomography (CT) scanned coffee beans from green (unroasted) through a dark roast. DL models will be expected to identify voids within the coffee beans, and identify the level of roast of the bean from the CT reconstruction. The scope of this project is intended to meet the Capstone Project requirements of University of California San Diego (UCSD) Structural Engineering master’s degree and offer useful insight on Dragonfly’s DL capability for LANL’s Non-Destructive Evaluation (NDE) CT team. The results of this project will be presented to the E-6 NDE group within LANL. Data acquisition was completed with a North Star Imaging (NSI) X-25 CT Cabinet.

97 MATHEMATICS AND COMPUTING↗

Automated segmentation of porous thermal spray material CT scans with predictive uncertainty estimation

Abstract Thermal sprayed metal coatings are used in many industrial applications, and characterizing the structure and performance of these materials is vital to understanding their behavior in the field. X-ray computed tomography (CT) enables volumetric, nondestructive imaging of these materials, but precise segmentation of this grayscale image data into discrete material phases is necessary to calculate quantities of interest related to material structure. In this work, we present a methodology to automate the CT segmentation process as well as quantify uncertainty in segmentations via deep learning. Neural networks (NNs) have been shown to excel at segmentation tasks; however, memory constraints, class imbalance, and lack of sufficient training data often prohibit their deployment in high resolution volumetric domains. Our 3D convolutional NN implementation mitigates these challenges and accurately segments full resolution CT scans of thermal sprayed materials with maps of uncertainty that conservatively bound the predicted geometry. These bounds are propagated through calculations of material properties such as porosity that may provide an understanding of anticipated behavior in the field.

Martinez, Carianne↗