Search NASA⌕ Search

SEARCH · Search NASA

Results for “CYCLOTRON RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Overview of the physics basis for the ARC fusion power plant

Commonwealth Fusion Systems plans to build ARC as the first fusion power plant at a site in Chesterfield County, Virginia, USA by the early 2030s. We present an overview of analysis comprising the physics basis of the ARC V3A design, a high-magnetic-field tokamak with 𝐵 0 =11.4 T, 𝐼 𝑝 =12.0 MA, 𝑅 0 =4.62 m, 𝑎 =1.18 m. ARC V3A is designed to produce 𝑃 𝑓⁡𝑢⁢𝑠 ≈1.13 GW DT fusion power and deliver ⩾400 MW net electric power to the grid. This overview includes quantitative analysis of fundamental issues for design of and operational plasma scenarios for a tokamak power plant, and lays out the design targets and strategic choices for ARC, including empirical fusion performance projections, assessment of H-mode access, ion cyclotron resonance heating simulations, alpha particle physics and time-dependent full-pulse simulations. This is complemented by topical papers on fusion performance and transport, disruption physics, boundary physics and magnetohydrodynamic stability. Critically, these studies identify key model uncertainties and physics risks to be retired through SPARC operation. Due to the modular nature of ARC, early results from SPARC can be incorporated into the design of the first ARC as well as subsequent replacements of the ARC vacuum vessel.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-Cell Metabolic Profiling: Metabolite Formulas from Isotopic Fine Structures in Heterogeneous Plant Cell Populations

Characterization of the metabolic heterogeneity in cell populations requires the analysis of single cells. Most current methods in single-cell analysis rely on cell manipulation, potentially altering the abundance of metabolites in individual cells. Small sample volume and the chemical diversity of metabolites are additional challenges in single-cell metabolomics. Here, we describe the combination of fiber-based laser ablation electrospray ionization (f-LAESI) with 21 tesla Fourier transform ion cyclotron resonance mass spectrometry (21TFTICR-MS) for in situ single-cell metabolic profiling in plant tissue. Single plant cells infected by bacteria were selected and sampled directly from the tissue without cell manipulation through mid-infrared ablation with a fine optical fiber tip for ionization by f-LAESI. Finally, ultrahigh performance 21T-FTICR-MS enabled the simultaneous capture of isotopic fine structures (IFSs) for 47 known and 11 unknown compounds, thus elucidating their elemental compositions from single cells, and providing information on metabolic heterogeneity in the cell population.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Assessment of Mammalian Lipidome Complexity Using Multimodal 21 T FTICR Mass Spectrometry Imaging

Herein, we assess the complementarity and complexity of data that can be detected within mammalian lipidome mass spectrometry imaging (MSI) via matrix-assisted laser desorption ionization (MALDI) and nanospray desorption electrospray ionization (nano-DESI). We do so by employing 21 T Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) with absorption mode FT processing in both cases, allowing unmatched mass resolving power per unit time (≥613k at m/z 760, 1.536 s transients). While our results demonstrated that molecular coverage and dynamic range capabilities were greater in MALDI analysis, nano-DESI provided superior mass error, and all annotations for both modes had sub-ppm error. Taken together, these experiments highlight the coverage of 1676 lipids and serve as a functional guide for expected lipidome complexity within nano-DESI-MSI and MALDI-MSI. To further assess the lipidome complexity, mass splits (i.e., the difference in mass between neighboring peaks) within single pixels were collated across all pixels from each respective MSI experiment. The spatial localization of these mass splits was powerful in informing whether the observed mass splits were biological or artificial (e.g., matrix related). Mass splits down to 2.4 mDa were observed (i.e., sodium adduct ambiguity) in each experiment, and both modalities highlighted comparable degrees of lipidome complexity. Further, we highlight the persistence of certain mass splits (e.g., 8.9 mDa; double bond ambiguity) independent of ionization biases. Here, we also evaluate the need for ultrahigh mass resolving power for mass splits ≤4.6 mDa (potassium adduct ambiguity) at m/z > 1000, which may only be resolved by advanced FTICR-MS instrumentation.

21T-FTICR-MS↗

Natural Abundance Isotope Ratio Measurements of Organic Molecules Using 21 T FTICR MS

Subtle variations in stable isotope ratios at natural abundance are challenging to measure but can yield critical insights into biological, physical, and geochemical processes. Well established methods, particularly multi-collector, gas-source or plasma isotope ratio mass spectrometry (IRMS) are the gold standard for stable isotope measurement but inherent limitations in these approaches make them ill-suited to determining site-specific and multiply substituted isotopic abundances of all but a few compounds, or to characterizing mixtures or larger intact molecules. Additionally, Fourier transform mass spectrometry (FTMS), namely Orbitrap mass spectrometry, has recently demonstrated the ability to measure natural abundance isotope ratios with chemically informative accuracy and precision. Here, we report the first use of Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) for the accurate (<1‰) and precise (<1‰ standard error) simultaneous determination of $δ$ 13 C and $δ$ 15 N in caffeine isotopologues and provide a discussion of the critical instrumental parameters necessary to make such measurements. Finally, we report the ability to make these measurements with online liquid chromatography, expanding the ability of this technique to explore mixtures in the future.

07 ISOTOPE AND RADIATION SOURCES↗

Improved Characterization of Soil Organic Matter by Integrating FT-ICR MS, Liquid Chromatography Tandem Mass Spectrometry, and Molecular Networking: A Case Study of Root Litter Decay under Drought Conditions

Understanding of how soil organic matter (SOM) chemistry is altered in a changing climate has advanced considerably; however, most SOM components remain unidentified, impeding the ability to characterize a major fraction of organic matter and predict what types of molecules, and from which sources, will persist in soil. Here we present a novel approach to better characterize SOM extracts by integrating information from three types of analyses, and we deploy this method to characterize decaying root-detritus soil microcosms subjected to either drought or normal conditions. To observe broad differences in composition, we employed direct infusion Fourier-transform ion cyclotron resonance mass spectrometry (DI-FT-ICR MS). We complemented this with liquid chromatography tandem mass spectrometry (LC-MS/MS) to identify components by library matching. Since libraries contain only a small fraction of SOM components, we also used fragment spectral cosine similarity scores to relate unknowns and library matches through molecular networks. This integrated approach allowed us to corroborate DI-FT-ICR MS molecular formulas using library matches, which included fungal metabolites and related polyphenolic compounds. We also inferred structures of unknowns from molecular networks and improved LC-MS/MS annotation rates from ~5 to 35% by considering DI-FT-ICR MS molecular formula assignments. Under drought conditions, we found greater relative amounts of lignin-like vs condensed aromatic polyphenol formulas and lower average nominal oxidation state of carbon, suggesting reduced decomposition of SOM and/or microbes under stress. Our integrated approach provides a framework for enhanced annotation of SOM components that is more comprehensive than performing individual data analyses in parallel.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data Set Analysis to Reduce Uncertainty in Formula Assignments of Ultrahigh Resolution Mass Spectra

Environmental samples contain a vast array of organic compounds with diverse elemental compositions and heteroatom content. Molecular formula assignments of ultrahigh resolution mass spectra (HRMS) hold promise for elucidating the molecular composition of these compounds. However, the need to account for an assortment of heteroatoms increases the uncertainty associated with individual assignments – and ultimately the ecological, biological, and biogeochemical insights gleaned from the assignments. To address this challenge, we introduce a formula assignment strategy that leverages HRMS data sets to improve assignment confidence, filter false assignments, and mitigate bias in assignment routines. The strategy, implemented using CoreMS, first identifies the highest confidence assignment for a recurring ion in a data set by assessing the mass accuracy and isotopologue similarity of all assignments to the ion across the data set. The second component of the strategy examines the consistency of mass errors for an assigned ion throughout a data set and flags formulas with statistically unlikely deviations in mass error. Here, we illustrate the application and utility of the strategy by comparing its results against documented misassignment patterns within a set of oceanographic samples that were measured with 21 T Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Because the efficacy of our strategy improves with data set size, it is particularly useful for enhancing assignment confidence in large HRMS data sets common in studies of environmental systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced Spatial Proteomics and Metabolomics from a Single Tissue Section Using MALDI-MSI and LCM-microPOTS Platforms

Spatially resolved mass spectrometry (MS)-based multi-omics workflows are becoming more utilized for revealing the complex biology that occurs within tissues. However, these approaches commonly require multiple independent tissue sections to analyze the metabolite and protein compositions of these samples. This poses a significant challenge in preserving cell- or region-specific molecular fidelity, as variations between tissue sections can compromise the accurate correlation of molecular data. Here, in this study, we developed workflows for comprehensive multi-omics profiling from a single tissue section (STS) using different MS modalities. We enhanced the functionality of an electrically insulated substrate by employing metal-assisted approaches that enabled both MS-based untargeted spatial metabolomics and proteomics from STS. This allowed metabolite imaging using matrix-assisted laser desorption/ionization-MS imaging (MALDI-MSI), without compromising it for subsequent proteome profiling with laser capture microdissection (LCM)-based technology. Specifically, implementing copper tape as a backing for polyethylene naphthalate (PEN) slides enabled the detection of >140 metabolites across a poplar root tissue section using MALDI-trapped ion mobility spectrometry time of flight (timsTOF)-MS. Afterwards, we detected 6,571 unique proteins from two distinct root regions by leveraging LCM technology coupled to our microdroplet based sample preparation approach. We also developed an alternative workflow utilizing gold-coated PEN substrates for imaging with MALDI-Fourier-transform ion cyclotron resonance (FTICR)-MS, which permitted the profiling of >170 metabolites and the identification of 6,542 unique proteins across a single poplar root tissue section. These results were comparable to using each assay independently without modifications. These approaches offer new opportunities for high-resolution molecular profiling of multiple omics-levels across biological tissues.

Veličković, Marija [Pacific Northwest National Lab↗

Comparison of the Chemical Composition of Liquids from the Pyrolysis and Hydrothermal Liquefaction of Lignocellulosic Materials

Major differences in thermal stability and hydrotreatment behavior of HTL and pyrolysis oils have been reported in the literature. However, little is known about the variations in the chemical composition of these oils that could explain such differences. Two commercial wood pyrolysis oils (Pyrovac and BTG), and their water-soluble (WS) and water-insoluble fractions (WIS) were analyzed and compared with the aqueous (WS WD-57 ) and oily (WIS WS-57 ) fractions obtained from hydrothermal liquefaction (HTL) of Douglas-fir. The samples were characterized by GC/MS, Karl Fischer titration, carbonyl content, total acid number, elemental composition, calorific value, proximate analysis, Fourier Transform Infrared Spectroscopy (FTIR), Folin-Ciocalteu (FC), and UV fluorescence. All the fractions were also analyzed by Fourier Transform Ion Cyclotron Resonance Mass Spectroscopy (FT-ICR-MS) and by Electrospray Ionization (EI). The most prevalent class of compounds in the water insoluble phases were phenols derived from lignin. Water-soluble phases contain mostly the oxygenated compounds derived from cellulose and hemicellulose and were richer in carbonyl functional groups. The water content of the resulting aqueous phases were between: 65 (WS BTG ) and 96 (WS Pyrovac ) wt. %. The bio-oil from BTG has higher water content and lower HHV, compared to Pyrovac oil. The GC/MS results of BTG oil show the presence of a more prominent acetic acid peak and higher TAN number than the Pyrovac oil. The GC/MS of Pyrovac oil showed more obvious mono-phenol peaks. The quantification of this family by Folin-Ciocalteu method confirmed higher content of monophenolic compounds compared with the BTG oil. The lower thermal stability of pyrolysis oils compared with HTL biocrudes can be partially explained by the fact that pyrolysis oils (BTG and Pyrovac) contain carbohydrates while HTL biocrude (WIS WD-57 ) doesn’t. Thus, we decided to further investigate the chemical differences between the phenolic rich fractions insoluble in water and the holocellulose derived compounds soluble in water. Even after water extraction, the acid content of the water insoluble fraction from BTG (WISBTG) was higher than the acid content of the water insoluble fraction obtained by HTL (WISWSD-57). Likewise, the acid content of the aqueous phases derived from pyrolysis oils (WS Pyrovac , WS BTG ) was also higher than for the aqueous phase obtained by HTL (WSWSD-57). This result is in part due to the use of bases in the HTL process that neutralizes the acid formed in that process. Moreover, the starting feedstock may also influence the differences between the oils. Although, the UV-Fluorescence spectra, ICR-MS and the EI analyses showed some minor differences in the molecular weight and chemical make-up of the oligomers soluble and insoluble in water from pyrolysis and HTL; the differences observed were not large enough to justify the differences in behavior between these oils reported in the literature. Our results suggest that the differences observed between HTL biocrudes and pyrolysis oils are likely partially due to the presence of holocellulose derived products in the pyrolysis oils and higher acid contents.

09 BIOMASS FUELS↗

Relating Molecular Properties to the Persistence of Marine Dissolved Organic Matter with Liquid Chromatography–Ultrahigh-Resolution Mass Spectrometry

Marine dissolved organic matter (DOM) contains a complex mixture of small molecules that eludes rapid biological degradation. Spatial and temporal variations in the abundance of DOM reflect the existence of fractions that are removed from the ocean over different time scales, ranging from seconds to millennia. However, it remains unknown whether the intrinsic chemical properties of these organic components relate to their persistence. Here, we elucidate and compare the molecular compositions of distinct DOM fractions with different lability along a water column in the North Atlantic Gyre. Our analysis utilized ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry at 21 T coupled to liquid chromatography and a novel data pipeline developed in CoreMS that generates molecular formula assignments and metrics of isomeric complexity. Clustering analysis binned 14 857 distinct molecular components into groups that correspond to the depth distribution of semilabile, semirefractory, and refractory fractions of DOM. The more labile fractions were concentrated near the ocean surface and contained more aliphatic, hydrophobic, and reduced molecules than the refractory fraction, which occurred uniformly throughout the water column. These findings suggest that processes that selectively remove hydrophobic compounds, such as aggregation and particle sorption, contribute to variable removal rates of marine DOM.

54 ENVIRONMENTAL SCIENCES↗

Activation, Dehydrogenation, and Carbon–Carbon Coupling of Methane by Iridium Cations Studied by Infrared Multiple Photon Dissociation Spectroscopy and Density Functional Theory

Products resulting from the sequential activation of one, two, three, and four methane molecules by atomic iridium cations were characterized by gas-phase infrared multiple photon dissociation spectroscopy and density functional theory (DFT) calculations. Iridium cations were generated using a laser ablation source and reacted with methane in a linear radiofrequency ion trap before mass analysis and spectroscopic interrogation in a Fourier transform ion cyclotron resonance mass spectrometer coupled to the free-electron laser for intracavity experiments (FELICE) beamline. Product ions were irradiated using infrared light over the 250–1500 cm –1 range. Comparisons between the experimental and DFT-calculated spectra enabled structural determination of the products formed. The observed products include HIrCH + , Ir(CH 2 ) 2 + , H s Ir(C 3 H 5 ) + , and Ir(CH 3 ) s (C 3 H 5 ) + , where the subscript s denotes a syn orientation of the two ligands. Furthermore, formation of the latter two products provides evidence for efficient C–H bond activation and subsequent C–C coupling on the atomic iridium cation.

Chemical reactions↗

Molecular Transformation of Dissolved Organic Matter during the Processes of Wildfire, Alum Coagulation, and Disinfection Using ESI(-) and ESI(+) FT-ICR MS

Forest fires alter the quality of terrestrial dissolved organic matter (DOM) flushed into source water, which could be further changed during alum coagulation and serve as potential disinfection byproduct (DBP) precursors in water facilities. To unveil this molecular transformation, we applied 12T Fourier transform ion cyclotron resonance mass spectrometry on a controlled study which used the leachates of black and white ashes (collected immediately after the 2013 Rim Fire, CA) along with unburned white fir (Abies concolor) and ponderosa pine (Pinus ponderosa). Here, results showed that the assigned features in DOM from burned ashes had a smaller molecular weight (MW), contained more unsaturated, aromatic, and oxidized and less fraction of labile compounds, and were enriched with nitrogen, relative to unburned litters. After alum coagulation, we observed the disappeared features with higher MW and S/C and N/C atom ratios than the resistant features. During the following disinfections, the disappeared features serving as the potential DBP precursors had higher MW and unsaturation degree, contained more S- and N-containing functionalities, and were more aromatic, compared to the resistant features. Our study suggested organic compounds with small MW and high aromaticity as the targets for water facilities to improve post-fire drinking water quality.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Emergent Chemical Behavior in Mixed Food and Lignocellulosic Green Waste Hydrothermal Liquefaction

Hydrothermal liquefaction (HTL) is a promising strategy for the conversion of energy-dense waste streams to fuels. Mixed-feed HTL aggregates multiple feed streams to achieve greater scales that capitalize on local resources, hence lowering costs. The potential for new pathways and products upon feedstock blending becomes a compounding level of complexity when unlocking emergent chemistries. Here, food and green waste streams were evaluated under HTL conditions (300 °C, 1 h) to understand the effect of feed molecular composition on product distributions and mechanisms. Thousands of emergent chemical compounds were detected via Fourier transform ion cyclotron resonance mass spectrometry, ultimately leading to the emergence of two dominant outcomes. First, the presence of small amounts of food waste into green waste results in substantial decarboxylation and subsequent polymerization to biocrude than chars. Second, in the other limit, small amounts of green waste promote the capping of oxygenates into the biodiesel range, such as with the emergence of fatty acid methyl esters.

09 BIOMASS FUELS↗

Identification of Solid-Electrolyte Interphase Species by Joint Characterization of Li-Ion Battery Chemistry by Mass Spectrometry and Electrochemical Reaction Networks

The formation and stability of the solid-electrolyte interphase (SEI) play central roles in determining the long-term performance and safety of modern electrochemical energy storage systems. Despite decades of research, the SEI’s heterogeneous, dynamic, and multiphase nature has defied comprehensive molecular-level characterization, creating a critical knowledge gap that limits rational battery design. In this work, we introduce a computational−experimental framework that integrates high-throughput quantum chemistry calculations, data-driven electrochemical reaction networks (eCRNs), stochastic algorithms, and laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry (LDI-FTICR-MS) to unravel SEI formation in carbonatebased electrolytes without imposing predefined mechanisms. We constructed the most comprehensive eCRN to date, spanning over 10,000 species and 209 million reactions. Through stochastic network analysis, we successfully recovered 27 species that were previously reported in the literature and predicted 28 novel SEI species nearly doubling our scientific knowledge in this area. Each new species was rigorously confirmed through advanced mass spectral analysis of its distinct molecular and isotopic signatures. We kinetically refined the formation pathways for a select set of both previously reported and novel SEI products, revealing kinetically feasible elementary reaction mechanisms with activation barriers below 1 eV. This computational−experimental approach deepens our molecular-level understanding of SEI chemistry by resolving which species form and through which decomposition mechanisms they emerge. Such knowledge provides the foundation necessary to connect electrolyte composition to the resulting SEI components, a critical step toward a more informed electrolyte development in next-generation lithium-based batteries.

25 ENERGY STORAGE↗

Large-Scale Interlaboratory DI-FT-ICR MS Comparability Study Employing Various Systems

We report ultra-high resolution mass spectrometry (UHR-MS) coupled with direct infusion (DI) electrospray ionization offers a fast solution for accurate untargeted profiling. Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometers have been shown to produce a wealth of insights into complex chemical systems because they enable unambiguous molecular formula assignment even if the vast majority of signals is of unknown identity. Inter-laboratory comparisons are required to apply this type of instrumentation in quality control (for food industry or pharmaceutics), large-scale environmental studies or clinical diagnostics. Extended comparisons employing different FT-ICR MS instruments with qualitative direct infusion analysis are scarce since the majority of detected compounds cannot be quantified. The extent to which observations can be reproduced by different laboratories remains unknown. We set up a preliminary study which encompassed a set of seventeen laboratories around the globe, diverse in instrumental characteristics and applications, to analyze the same sets of extracts from commercially available standard human blood plasma and Standard Reference Material (SRM) for blood plasma (SRM1950), which were delivered at different dilutions or spiked with different concentrations of pesticides. The aim of this study was to assess the extent to which the outputs of differently tuned FTICR mass spectrometers, with different technical specifications, are comparable for setting the frames of a future DI-FT-ICR MS ring trial. We concluded that a cluster of five laboratories, with diverse instrumental characteristics showed comparable and representative performance across all experiments, setting a reference to be used in a future ring trial on blood plasma.

47 OTHER INSTRUMENTATION↗

Large Individual Ion FTICR Measurements from the Mid-1990s Using Reactions for Charge Determination Mass Spectrometry

This article discusses from a personal and present-day perspective the first studies of large highly charged individual molecular ions that were conducted using electrospray ionization (ESI) with Fourier transform ion cyclotron resonance (FTICR) MS in the mid-1990s. These studies are distinguished from current Charge Detection Mass Spectrometry (CDMS) research primarily by their use of individual ion charge state changes due to reactions. Here this work describes the key differences in technologies and methods with present CDMS, and the likely implications of these differences. I also comment on surprising individual ion behavior observed in some measurements involving increases in charge state, as well as their possible basis, and also briefly discuss the potential utility of the reaction-based mass measurement approach used in the context of what might more globally be referred to as ‘Charge Determination Mass Spectrometry’.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Response Surface Methodology As a New Approach for Finding Optimal MALDI Matrix Spraying Parameters for Mass Spectrometry Imaging

Automated spraying devices have become ubiquitous in laboratories employing matrixassisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI), in part because they permit control of a number of matrix application parameters that can easily be reproduced for intra- and interlaboratory studies. Determining the optimal parameters for MALDI matrix application, such as temperature, flow rate, spraying velocity, number of spraying cycles, and solvent composition for matrix application, is critical for obtaining high-quality MALDI-MSI data. However, there are no established approaches for optimizing these multiple parameters simultaneously. Instead optimization is performed iteratively (i.e., one parameter at a time), which is time consuming and can lead to overall non-optimal settings. In this report, we demonstrate the use a novel experimental design and the response surface methodology to optimize five parameters of MALDI matrix application using a robotic sprayer. Thirtytwo combinations of MALDI matrix spraying conditions were tested, which allowed us to elucidate relationships between each of the application parameters as determined by MALDI-MS (specifically, using a 15 Tesla Fourier transform ion cyclotron resonance mass spectrometer). As such, we were able to determine the optimal automated spraying parameters that minimized signal de-localization and enabled high MALDI sensitivity. We envision this optimization strategy can be utilized for other MALDI-MSI applications, tissue types, and matrix application approaches.

60 APPLIED LIFE SCIENCES↗

The Impact of Freeze‐Thaw History on Soil Carbon Response to Experimental Freeze‐Thaw Cycles

Abstract Freeze‐thaw is a disturbance process in cold regions where permafrost soils are becoming vulnerable to temperature fluctuations above 0°C. Freeze‐thaw alters soil physical and biogeochemical properties with implications for carbon persistence and emissions in Arctic landscapes. We examined whether different freeze‐thaw histories in two soil systems led to contrasting biogeochemical responses under a laboratory‐controlled freeze‐thaw incubation. We investigated controls on carbon composition through Fourier‐transform ion cyclotron resonance mass spectrometry (FT‐ICR‐MS) to identify nominal carbon oxidation states and relative abundances of aliphatic‐type carbon molecules in both surface and subsurface soils. Soil cores (∼60 cm‐depth) were sampled from two sites in Alaskan permafrost landscapes with different in situ freeze‐thaw characteristics: Healy (>40 freeze‐thaw cycles annually) and Toolik (<15 freeze‐thaw cycles annually). FT‐ICR‐MS was coupled with in situ temperature data and soil properties (i.e., soil texture, mineralogy) to assess (a) differences in soil organic matter composition associated with previous freeze‐thaw history and (b) sensitivity to experimental freeze‐thaw in the extracted cores. Control (freeze‐only) samples showed greater carbon oxidation in Healy soils compared with Toolik, even in lower mineral horizons where freeze‐thaw history was comparable across both sites. Healy showed the most loss of carbon compounds following experimental freeze‐thaw in the lower mineral depths, including a decrease in aliphatics. Toolik soils responded more slowly to freeze‐thaw as shown by intermediary carbon oxidation distributed across multiple carbon compound classes. Variations in the response of permafrost carbon chemistry to freeze‐thaw is an important factor for predicting changes in soil function as permafrost thaws in high northern latitudes.

Rooney, Erin C.↗

(Un)Explained EMIC Waves: Understanding Quiet Time EMIC Wave Drivers

Electromagnetic ion cyclotron (EMIC) waves are known to be generated through cyclotron resonance with the local ion particle population and grow when there is a large enough temperature anisotropy. In general, these temperature anisotropies necessary for wave growth are found to be associated with either solar wind pressure pulses or particle injections during geomagnetic storms or substorms. However, some EMIC events do not show any clear association with these known drivers and appear unexplained. In our analysis of high-amplitude (>1 nT) non-storm time EMIC waves, we find that 24 out of the 223 (~11%) EMIC events with peak amplitude greater than 1 nT were not found to be associated with any clear EMIC wave driver. This raises a compelling question: What magnetospheric or solar wind driver provides the free energy to grow these quiet-time EMIC waves? Here, we examine two EMIC events on 13 April 2017 and 13 February 2014, which were excited during extremely quiet solar wind and geomagnetic conditions. Furthermore, an in-depth analysis of field and particle measurements from multiple data sets, including ground and in situ data for these two events, indicates that extremely weak and otherwise insignificant pressure values and/or very weak substorm injections occurring multiple hours before the event play a significant role in quiet time wave generation.

79 ASTRONOMY AND ASTROPHYSICS↗