Search NASA⌕ Search

SEARCH · Search NASA

Results for “Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Improving Photometric Calibration of Meteor Video Camera Systems

We present the results of new calibration tests performed by the NASA Meteoroid Environment Office (MEO) designed to help quantify and minimize systematic uncertainties in meteor photometry from video camera observations. These systematic uncertainties can be categorized by two main sources: an imperfect understanding of the linearity correction for the MEO's Watec 902H2 Ultimate video cameras and uncertainties in meteor magnitudes arising from transformations between the Watec camera's Sony EX-View HAD bandpass and the bandpasses used to determine reference star magnitudes. To address the first point, we have measured the linearity response of the MEO's standard meteor video cameras using two independent laboratory tests on eight cameras. Our empirically determined linearity correction is critical for performing accurate photometry at low camera intensity levels. With regards to the second point, we have calculated synthetic magnitudes in the EX bandpass for reference stars. These synthetic magnitudes enable direct calculations of the meteor's photometric flux within the camera bandpass without requiring any assumptions of its spectral energy distribution. Systematic uncertainties in the synthetic magnitudes of individual reference stars are estimated at approx. 0.20 mag, and are limited by the available spectral information in the reference catalogs. These two improvements allow for zero-points accurate to 0.05 - 0.10 mag in both filtered and unfiltered camera observations with no evidence for lingering systematics. These improvements are essential to accurately measuring photometric masses of individual meteors and source mass indexes.

Steven Ehlert↗

Rover mast calibration, exact camera pointing, and camara handoff for visual target tracking

This paper presents three technical elements that we have developed to improve the accuracy of the visual target tracking for single-sol approach-and-instrument placement in future Mars rover missions. An accurate, straightforward method of rover mast calibration is achieved by using a total station, a camera calibration target, and four prism targets mounted on the rover. The method was applied to Rocky8 rover mast calibration and yielded a 1.1-pixel rms residual error. Camera pointing requires inverse kinematic solutions for mast pan and tilt angles such that the target image appears right at the center of the camera image. Two issues were raised. Mast camera frames are in general not parallel to the masthead base frame. Further, the optical axis of the camera model in general does not pass through the center of the image. Despite these issues, we managed to derive non-iterative closed-form exact solutions, which were verified with Matlab routines. Actual camera pointing experiments aver 50 random target image paints yielded less than 1.3-pixel rms pointing error. Finally, a purely geometric method for camera handoff using stereo views of the target has been developed. Experimental test runs show less than 2.5 pixels error on high-resolution Navcam for Pancam-to-Navcam handoff, and less than 4 pixels error on lower-resolution Hazcam for Navcam-to-Hazcam handoff.

camera handoff↗

Factorization of correspondence and camera error for unconstrained dense correspondence applications

A correspondence and camera error analysis for dense correspondence applications such as structure from motion is introduced. This provides error introspection, opening up the possibility of adaptively and progressively applying more expensive correspondence and camera parameter estimation methods to reduce these errors. The presented algorithm evaluates the given correspondences and camera parameters based on an error generated through simple triangulation. This triangulation is based on the given dense, non-epipolar constraint, correspondences and estimated camera parameters. This provides an error map without requiring any information about the perfect solution or making assumptions about the scene. The resulting error is a combination of correspondence and camera parameter errors. An simple, fast low/high pass filter error factorization is introduced, allowing for the separation of correspondence error and camera error. Further analysis of the resulting error maps is applied to allow efficient iterative improvement of correspondences and cameras.

99 GENERAL AND MISCELLANEOUS↗

Extrinsic calibration of a single-point laser rangefinder and single camera

We present a new method for calibrating a single-point laser rangefinder and single camera because the combination of a cheap single-point laser range finder (LRF) and a camera has become increasingly helpful in recent industrial applications. In order to effectively use the date from the camera and LRF, it is important to know their relative position and orientation from each other. In this paper, a robust extrinsic calibration method for determining the position and direction of the LRF with respect to the camera is proposed. Due to the spot of the single-point LRF we commonly use is mostly invisible, infrared camera is utilized to detect laser spot and then establish the position relationship between visible light camera and infrared camera to calibrate the extrinsic parameters. Experimental results demonstrate that the proposed method can calibrate the extrinsic parameters with high precision and effectively.

42 ENGINEERING↗

A Stereo Camera Simulator for Large-Eddy Simulations of Continental Shallow Cumulus Clouds Based on Three-Dimensional Path-Tracing

The complex spatial and temporal structure of cumulus clouds complicates their representation in weather and climate models. Classic meteorological instrumentation struggles to fully capture these features. Networks of multiple high-resolution hemispheric cameras are increasingly used to fill this data gap, and provide information on this missing multi-dimensional spatial information. In this study, a path-tracing algorithm is used to generate virtual camera images of resolved clouds in large-eddy simulations (LES). These images are then used as a camera network simulator, allowing reconstructions of three-dimensional cloud edges from the model output. Because the actual LES cloud field is fully known, the combined path-tracing and reconstruction method can be statistically analyzed. The method is applied to LES realizations of summertime shallow cumulus at the Jülich Observatory for Cloud Evolution (JOYCE), Germany, which also routinely operates a camera network. We find that the path-tracing method allows accurate reconstruction of up to 70% of the visible cloud edges. Additional sensitivity tests show that the method is robust for changes in its hyperparameters. The sensitivity to cloud optical thickness is also investigated, finding a cloud boundary placement error of approximately 182 m. This error can be considered typical for cloud boundary reconstruction using real stereo camera imagery. The results provide proof of principle for future use of the method for evaluating LES clouds against camera network imagery, and for further optimizing the configuration of such camera networks.

54 ENVIRONMENTAL SCIENCES↗

SU-C-18A-02: Image-Based Camera Tracking: Towards Registration of Endoscopic Video to CT

Purpose: Endoscopic examinations are routinely performed on head and neck and esophageal cancer patients. However, these images are underutilized for radiation therapy because there is currently no way to register them to a CT of the patient. The purpose of this work is to develop a method to track the motion of an endoscope within a structure using images from standard clinical equipment. This method will be incorporated into a broader endoscopy/CT registration framework. Methods: We developed a software algorithm to track the motion of an endoscope within an arbitrary structure. We computed frame-to-frame rotation and translation of the camera by tracking surface points across the video sequence and utilizing two-camera epipolar geometry. The resulting 3D camera path was used to recover the surrounding structure via triangulation methods. We tested this algorithm on a rigid cylindrical phantom with a pattern spray-painted on the inside. We did not constrain the motion of the endoscope while recording, and we did not constrain our measurements using the known structure of the phantom. Results: Our software algorithm can successfully track the general motion of the endoscope as it moves through the phantom. However, our preliminary data do not show a high degree of accuracy in the triangulation of 3D point locations. More rigorous data will be presented at the annual meeting. Conclusion: Image-based camera tracking is a promising method for endoscopy/CT image registration, and it requires only standard clinical equipment. It is one of two major components needed to achieve endoscopy/CT registration, the second of which is tying the camera path to absolute patient geometry. In addition to this second component, future work will focus on validating our camera tracking algorithm in the presence of clinical imaging features such as patient motion, erratic camera motion, and dynamic scene illumination.

60 APPLIED LIFE SCIENCES↗

Evaluating MODIS Snow Products Using an Extensive Wildlife Camera Network

Snow covers a maximum of 47 million km 2 of Earth's northern hemisphere each winter and is an important component of the planet's energy balance, hydrology cycles, and ecosystems. Monitoring regional and global snow cover has increased in urgency in recent years due to warming temperatures and declines in snow cover extent. Optical satellite instruments provide large-scale observations of snow cover, but cloud cover and dense forest canopy can reduce accuracy in mapping snow cover. Remote camera networks deployed for wildlife monitoring operate below cloud cover and in forests, representing a virtually untapped source of snow cover observations to supplement satellite observations. Using images from 1,181 wildlife cameras deployed by the Norwegian Institute for Nature Research (NINA), we compared snow cover extracted from camera images to Moderate Resolution Imaging Spectroradiometer (MODIS) snow cover products during winter months of 2018–2020. Ordinal snow classifications (scale = 0–4) from cameras were closely related to normalized difference snow index (NDSI) values from the MODIS Terra Snow Cover Daily L3 Global 500m (MOD10A1) Collection 6 product (R 2 = 0.70). Tree canopy cover, the normalized difference vegetation index (NDVI), and image color mode influenced agreement between camera images and MOD10A1 NDSI values. For MOD10A1F, MOD10A1's corresponding cloud-gap filled product, agreement with cloud-gap filled values decreased from 78.5% to 56.4% in the first three days of cloudy periods and stabilized thereafter. Using our camera data as validation, we derived a threshold to create daily binary maps of snow cover from the MOD10A1 product. The threshold corresponding to snow presence was an NDSI value of 40.50, which closely matched a previously defined global binary threshold of 40 using the MOD10A2 8-day product. These analyses demonstrate the utility of camera trap networks for validation of snow cover products from satellite remote sensing, as well as their potential to identify sources of inaccuracy.

Validation↗

3D camera assisted fully automated calibration of scanning laser Doppler vibrometers

Scanning laser Doppler vibrometers (LDV) are used to measure full-field vibration shapes of products and structures. In most commercially available scanning laser Doppler vibrometer systems the user manually draws a grid of measurement locations on a 2D camera image of the product. The determination of the correct physical measurement locations can be a time consuming and diffcult task. In this paper we present a new methodology for product testing and quality control that integrates 3D imaging techniques with vibration measurements. This procedure allows to test prototypes in a shorter period because physical measurements locations will be located automatically. The proposed methodology uses a 3D time-of-flight camera to measure the location and orientation of the test-object. The 3D image of the time-of-flight camera is then matched with the 3D-CAD model of the object in which measurement locations are pre-defined. A time of flight camera operates strictly in the near infrared spectrum. To improve the signal to noise ratio in the time-of-flight measurement, a time-of-flight camera uses a band filter. As a result of this filter, the laser spot of most laser vibrometers is invisible in the time-of-flight image. Therefore a 2D RGB-camera is used to find the laser-spot of the vibrometer. The laser spot is matched to the 3D image obtained by the time-of-flight camera. Next an automatic calibration procedure is used to aim the laser at the (pre)defined locations. Another benefit from this methodology is that it incorporates automatic mapping between a CAD model and the vibration measurements. This mapping can be used to visualize measurements directly on a 3D CAD model. Secondly the orientation of the CAD model is known with respect to the laser beam. This information can be used to find the direction of the measured vibration relatively to the surface of the object. With this direction, the vibration measurements can be compared more precisely with numerical experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PiCAM: A Raspberry Pi-based open-source, low-power camera system for monitoring plant phenology in Arctic environments

Time-lapse cameras have been widely used as a tool to monitor the timing of seasonal vegetation growth. These simple, relatively inexpensive systems can provide high-frequency observations of leaf development and demography which are critical data sets needed to characterize plant phenology from species to landscapes. This is important for understanding how plants are responding to global changes, as well as for validating satellite-derived phenology products. However, in remote regions including the high-latitude Arctic, deploying time-lapse cameras could be challenging. The remoteness and lack of widespread power and telecommunications infrastructure limit options for the installation, maintenance and retrieval of data and equipment, and make it difficult for cameras to survive in extreme weather (e.g. long cold winters). To improve our understanding of Arctic phenology, new technologies are required to address these challenges. Here, we present a novel, low-power, compact, lightweight time-lapse camera system, called power-interval camera automation module (PiCAM). The PiCAM was designed with explicit consideration to simplify deployment (i.e. without a need for external power supplies) of camera systems and to address the challenges of camera survival in harsh Arctic environments. In this paper, we describe the design, setup and technical details of the PiCAM and provide a roadmap for how to build and operate these systems. As proof of concept, we deployed 26 PiCAMs at three low-Arctic tundra sites on the Seward Peninsula, Alaska in early August 2021 for characterizing Arctic plant phenology. Of the 26 PiCAMs, 70% remained active at the point of our revisit in late July 2022 despite the extreme winter temperatures they experienced (< –30°C, heavy snow cover). We extracted key plant phenology metrics from the PiCAMs and captured strong differences across key Arctic plant species. We showed that the PiCAM has the potential to be widely used for monitoring plant phenology across the broader Arctic region, addressing the need for ground-based understanding of Arctic phenological diversity to develop knowledge of plant response to climate change and to validate remote sensing products.

54 ENVIRONMENTAL SCIENCES↗

To image, or not to image: class-specific diffractive cameras with all-optical erasure of undesired objects

Abstract Privacy protection is a growing concern in the digital era, with machine vision techniques widely used throughout public and private settings. Existing methods address this growing problem by, e.g., encrypting camera images or obscuring/blurring the imaged information through digital algorithms. Here, we demonstrate a camera design that performs class-specific imaging of target objects with instantaneous all-optical erasure of other classes of objects. This diffractive camera consists of transmissive surfaces structured using deep learning to perform selective imaging of target classes of objects positioned at its input field-of-view. After their fabrication, the thin diffractive layers collectively perform optical mode filtering to accurately form images of the objects that belong to a target data class or group of classes, while instantaneously erasing objects of the other data classes at the output field-of-view. Using the same framework, we also demonstrate the design of class-specific permutation and class-specific linear transformation cameras, where the objects of a target data class are pixel-wise permuted or linearly transformed following an arbitrarily selected transformation matrix for all-optical class-specific encryption, while the other classes of objects are irreversibly erased from the output image. The success of class-specific diffractive cameras was experimentally demonstrated using terahertz (THz) waves and 3D-printed diffractive layers that selectively imaged only one class of the MNIST handwritten digit dataset, all-optically erasing the other handwritten digits. This diffractive camera design can be scaled to different parts of the electromagnetic spectrum, including, e.g., the visible and infrared wavelengths, to provide transformative opportunities for privacy-preserving digital cameras and task-specific data-efficient imaging.

47 OTHER INSTRUMENTATION↗

Multi-Angle Snowflake Camera Instrument Handbook

The Multi-Angle Snowflake Camera (MASC) takes 9- to 37-micron resolution stereographic photographs of free-falling hydrometers from three angles, while simultaneously measuring their fall speed. Information about hydrometeor size, shape orientation, and aspect ratio is derived from MASC photographs. The instrument consists of three commercial cameras separated by angles of 36º. Each camera field of view is aligned to have a common single focus point about 10 cm distant from the cameras. Two near-infrared emitter pairs are aligned with the camera’s field of view within a 10-angular ring and detect hydrometeor passage, with the lower emitters configured to trigger the MASC cameras. The sensitive IR motion sensors are designed to filter out slow variations in ambient light. Fall speed is derived from successive triggers along the fall path. The camera exposure times are extremely short, in the range of 1/25,000th of a second, enabling the MASC to capture snowflake sizes ranging from 30 micrometers to 3 cm.

47 OTHER INSTRUMENTATION↗

Characterization of Cameras for the COSMO K-coronagraph

Digital image sensors are ubiquitous in astronomical instrumentation and it is well known that they suffer from issues that must be corrected for data to be scientifically useful. I present discussion on errors resulting from digitization and characterization of nonlinearity and ADC errors of the PhotonFocus MV-D1024E cameras selected for the K-coronagraph of the Coronal Solar Magnetism Observatory. I derive an analytic expression for quantization errors. The MV-D1024E camera has adequate bit depth for which quantization error is not an issue. I show that this is not the case for all cameras, particularly those with deep wells and low read noise. The impact of nonlinearity and ADC errors on science observations of the K-coronagraph is analyzed using a simplified telescope model. Errors caused by the camera ADCs result in systematic errors in the measurement of the polarimetric signal of several times 10{sup −9} B {sub ⊙}, which is about an order of magnitude above the desired sensitivity. I demonstrate a method for post-facto data correction using a lookup table and derive parameters from camera characterization measurements that were made with a lab setup. Nonlinearity is traditionally addressed with a global correction. I show through analysis of calibration data that for the MV-D1024E this correction leaves residual systematic errors after dark and gain correction of up to 1% of the signal. I demonstrate that a pixel-wise correction of nonlinearity reduces the errors to below 0.1%. These corrections are necessary for the K-coronagraph data products to meet the science requirements. They have been implemented in the instrument data acquisition system and data reduction pipeline. While no other instruments besides the K-coronagraph or cameras besides the MV-D1024E are discussed here, the results are illustrative for all instruments and cameras.

79 ASTRONOMY AND ASTROPHYSICS↗

Sky camera geometric calibration using solar observations

A camera model and associated automated calibration procedure for stationary daytime sky imaging cameras is presented. The specific modeling and calibration needs are motivated by remotely deployed cameras used to forecast solar power production where cameras point skyward and use 180° fisheye lenses. Sun position in the sky and on the image plane provides a simple and automated approach to calibration; special equipment or calibration patterns are not required. Sun position in the sky is modeled using a solar position algorithm (requiring latitude, longitude, altitude and time as inputs). Sun position on the image plane is detected using a simple image processing algorithm. The performance evaluation focuses on the calibration of a camera employing a fisheye lens with an equisolid angle projection, but the camera model is general enough to treat most fixed focal length, central, dioptric camera systems with a photo objective lens. Calibration errors scale with the noise level of the sun position measurement in the image plane, but the calibration is robust across a large range of noise in the sun position. In conclusion, calibration performance on clear days ranged from 0.94 to 1.24 pixels root mean square error.

54 ENVIRONMENTAL SCIENCES↗

Cameras on the moon with Apollos 15 and 16.

Description of the cameras used for photography and television by Apollo 15 and 16 missions, covering a hand-held Hasselblad camera for black and white panoramic views at locations visited by the astronauts, a special stereoscopic camera designed by astronomer Tom Gold, a 16-mm movie camera used on the Apollo 15 and 16 Rovers, and several TV cameras. Details are given on the far-UV camera/spectrograph of the Apollo 16 mission. An electronographic camera converts UV light to electrons which are ejected by a KBr layer at the focus of an f/1 Schmidt camera and darken photographic films much more efficiently than far-UV. The astronomical activity of the Apollo 16 astronauts on the moon, using this equipment, is discussed.

Page, T.↗

Attitude identification for SCOLE using two infrared cameras

An algorithm is presented that incorporates real time data from two infrared cameras and computes the attitude parameters of the Spacecraft COntrol Lab Experiment (SCOLE), a lab apparatus representing an offset feed antenna attached to the Space Shuttle by a flexible mast. The algorithm uses camera position data of three miniature light emitting diodes (LEDs), mounted on the SCOLE platform, permitting arbitrary camera placement and an on-line attitude extraction. The continuous nature of the algorithm allows identification of the placement of the two cameras with respect to some initial position of the three reference LEDs, followed by on-line six degrees of freedom attitude tracking, regardless of the attitude time history. A description is provided of the algorithm in the camera identification mode as well as the mode of target tracking. Experimental data from a reduced size SCOLE-like lab model, reflecting the performance of the camera identification and the tracking processes, are presented. Computer code for camera placement identification and SCOLE attitude tracking is listed.

Shenhar, Joram↗

The NACA High-Speed Motion-Picture Camera Optical Compensation at 40,000 Photographs Per Second

The principle of operation of the NACA high-speed camera is completely explained. This camera, operating at the rate of 40,000 photographs per second, took the photographs presented in numerous NACA reports concerning combustion, preignition, and knock in the spark-ignition engine. Many design details are presented and discussed, details of an entirely conventional nature are omitted. The inherent aberrations of the camera are discussed and partly evaluated. The focal-plane-shutter effect of the camera is explained. Photographs of the camera are presented. Some high-speed motion pictures of familiar objects -- photoflash bulb, firecrackers, camera shutter -- are reproduced as an illustration of the quality of the photographs taken by the camera.

Miller, Cearcy D↗

Thermoelastic Analysis of Hyper-X Camera Windows Suddenly Exposed to Mach 7 Stagnation Aerothermal Shock

To visually record the initial free flight event of the Hyper-X research flight vehicle immediately after separation from the Pegasus(registered) booster rocket, a video camera was mounted on the bulkhead of the adapter through which Hyper-X rides on Pegasus. The video camera was shielded by a protecting camera window made of heat-resistant quartz material. When Hyper-X separates from Pegasus, this camera window will be suddenly exposed to Mach 7 stagnation thermal shock and dynamic pressure loading (aerothermal loading). To examine the structural integrity, thermoelastic analysis was performed, and the stress distributions in the camera windows were calculated. The critical stress point where the tensile stress reaches a maximum value for each camera window was identified, and the maximum tensile stress level at that critical point was found to be considerably lower than the tensile failure stress of the camera window material.

Ko, William L.↗

Calibration Tests of Industrial and Scientific CCD Cameras

Small format, medium resolution CCD cameras are at present widely used for industrial metrology applications. Large format, high resolution CCD cameras are primarily in use for scientific applications, but in due course should increase both the range of applications and the object space accuracy achievable by close range measurement. Slow scan, cooled scientific CCD cameras provide the additional benefit of additional quantisation levels which enables improved radiometric resolution. The calibration of all types of CCD cameras is necessary in order to characterize the geometry of the sensors and lenses. A number of different types of CCD cameras have been calibrated a the NASA Langley Research Center using self calibration and a small test object. The results of these calibration tests will be described, with particular emphasis on the differences between standard CCD video cameras and scientific slow scan CCD cameras.

Shortis, M. R.↗