Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cardiac Output”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Evaluation of an Impedance Threshold Device as a VIIP Countermeasure

Visual Impairment /Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs (Braslets) and lower body negative pressure (LBNP; Chibis) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure. The ITD works by providing up to 7 cm H2O (approximately 5 mmHg) resistance to inspiratory air flow, effectively turning the thorax into a vacuum pump upon each inhalation which lowers the intrathoracic pressure (ITP) and facilitates venous return to the heart. The ITD is FDA-approved and was developed to augment venous return to the central circulation and increase cardiac output during cardiopulmonary resuscitation (CPR) and in patients with hypotension. While the effect of ITD on CPR survival outcomes is controversial, the ITD's ability to lower ITP with a concomitant decrease in intracranial pressure (ICP) is well documented. A similar concept that creates negative ITP during exhalation (intrathoracic pressure regulator; ITPR) decreased ICP in 16 of 20 patients with elevated ICP in a hospital pilot study. ITP and central venous pressure (CVP) have been shown to decrease in microgravity however ITP drops more than CVP, indicating an increased transmural CVP. This could explain the paradoxical distention of jugular veins (JV) in microgravity despite lower absolute CVP and also suggests that JV transmural pressure is not dramatically elevated. Use of an ITD may lower JV pressure enough to remove or relieve cephalic venous congestion. During spaceflight experiments with Braslet thigh cuffs and modified (open-glottis) Mueller maneuvers, Braslets alone reduced cardiac preload but only reduced the internal JV (IJV) cross sectional area by 23%. The addition of Mueller maneuvers resulted in an IJV area reduction of 48%. This project will test if ITD essentially applies a Mueller maneuver with added negative ITP in every respiratory cycle, acting to: 1) reduce venous congestion in the neck and 2) potentially lower ICP. The expected mechanism of action is that in microgravity (or an analog) blood is relocated toward the heart from vasculature in the head and neck. Once validated, the ITD would be an exceptionally easy countermeasure to deploy and test on the ISS. Dosage could be altered though 1) duration of application and 2) inspiratory resistance set point. Effects could be additionally enhanced through co-application with other countermeasures such as thigh cuffs or LBNP.

Ebert, D.↗

Evaluation of an Impedance Threshold Device as a VIIP Countermeasure

Visual Impairment/Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs (Braslets) and lower body negative pressure (LBNP; Chibis) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure. The ITD works by providing up to 7 cm H2O (approximately 5 mmHg) resistance to inspiratory air flow, effectively turning the thorax into a vacuum pump upon each inhalation which lowers the intrathoracic pressure (ITP) and facilitates venous return to the heart. The ITD is FDA-approved and was developed to augment venous return to the central circulation and increase cardiac output during cardiopulmonary resuscitation (CPR) and in patients with hypotension. While the effect of ITD on CPR survival outcomes is controversial, the ITD's ability to lower ITP with a concomitant decrease in intracranial pressure (ICP) is well documented. A similar concept that creates negative ITP during exhalation (intrathoracic pressure regulator; ITPR) decreased ICP in 16 of 20 patients with elevated ICP in a hospital pilot study. ITP and central venous pressure (CVP) have been shown to decrease in microgravity however ITP drops more than CVP, indicating an increased transmural CVP. This could explain the paradoxical distention of jugular veins (JV) in microgravity despite lower absolute CVP and also suggests that JV transmural pressure is not dramatically elevated. Use of an ITD may lower JV pressure enough to remove or relieve cephalic venous congestion. During spaceflight experiments with Braslet thigh cuffs and modified (open-glottis) Mueller maneuvers, Braslets alone reduced cardiac preload but only reduced the internal JV (IJV) cross sectional area by 23%. The addition of Mueller maneuvers resulted in an IJV area reduction of 48%. This project will test if ITD essentially applies a Mueller maneuver with added negative ITP in every respiratory cycle, acting to: 1) reduce venous congestion in the neck and 2) potentially lower ICP. The expected mechanism of action is that in microgravity (or an analog) blood is relocated toward the heart from vasculature in the head and neck. Once validated, the ITD would be an exceptionally easy countermeasure to deploy and test on the ISS. Dosage could be altered though 1) duration of application and 2) inspiratory resistance set point. Effects could be additionally enhanced through co-application with other countermeasures such as thigh cuffs or LBNP.

Ebert, Douglas↗

Cardiopulmonary adaptation to weightlessness

The lung is profoundly affected by gravity. The absence of gravity (microgravity) removes the mechanical stresses acting on the lung paranchyma itself, resulting in a reduction in the deformation of the lung due to its own weight, and consequently altering the distribution of fresh gas ventilation within the lung. There are also changes in the mechanical forces acting on the rib cage and abdomen, which alters the manner in which the lung expands. The other way in which microgravity affects the lung is through the removal of the gravitationally induced hydrostatic gradients in vascular pressures, both within the lung itself, and within the entire body. The abolition of a pressure gradient within the pulmonary circulation would be expected to result in a greater degree of uniformity of blood flow within the lung, while the removal of the hydrostatic gradient within the body should result in an increase in venous return and intra-thoracic blood volume, with attendant changes in cardiac output, stroke volume, and pulmonary diffusing capacity. During the 9 day flight of Spacelab Life Sciences-1 (SLS-1) we collected pulmonary function test data on the crew of the mission. We compared the results obtained in microgravity with those obtained on the ground in both the standing and supine positions, preflight and in the week immediately following the mission. A number of the tests in the package were aimed at studying the anticipated changes in cardiopulmonary function, and we report those in this communication.

short duration↗

Modeling Microgravity Induced Fluid Redistribution Autoregulatory and Hydrostatic Enhancements

Space flight induces a marked cephalad (headward) redistribution of blood and interstitial fluid potentially resulting in a loss of venous tone and reduction in heart muscle efficiency upon introduction into the microgravity environment. Using various types of computational models, we are investigating how this fluid redistribution may induce intracranial pressure changes, relevant to reported reductions in astronaut visual acuity, part of the Visual Impairment and Intracranial Pressure (VIIP) syndrome. Methods: We utilize a lumped parameter cardiovascular system (CVS) model, augmented by compartments comprising the cerebral spinal fluid (CSF) space, as the primary tool to describe how microgravity, and the associated lack of hydrostatic gradient, impacts fluid redistribution. Models of ocular fluid pressures and biomechanics then accept the output of the above model as boundary condition input to allow more detailed, local analysis (see IWS Abstract by Ethier et al.). Recently, we enhanced the capabilities our previously reported CVS model through the implementation of robust autoregulatory mechanisms and a more fundamental approach to the implementation of hydrostatic mechanisms. Modifying the approach of Blanco et al., we implemented auto-regulation in a quasi-static manner, as an averaged effect across the span of one heartbeat. This approach reduced the higher frequency perturbations from the regulatory mechanism and was intended to allow longer simulation times (days) than models that implement within-beat regulatory mechanisms (minutes). A more fundamental approach to hydrostatics was implemented by a quasi-1D approach, in which compartment descriptions include compartment length, orientation and relative position, allowed for modeling of body orientation, relative body positioning and, in the future, alternative gravity environments. At this time the inclusion of hydrostatic mechanisms supplies additional capabilities to train and validate the CVS model with terrestrial data. Results and Conclusions: With the implementation of auto-regulation and hydrostatic modeling capabilities, the model performs as expected in the maintaining the CA (Central Artery) compartment pressure when simulating orientations ranging from supine to standing. The model appears to generally overpredict heart rate and thus cardiac output, possibly indicating sensitivity to the nominal heart rate, which is used as an initial set point of the regulation mechanisms. Despite this sensitivity, the model performs consistently for many hours of simulation time, indicating the success of our quasi-static implementation approach.

biomechanics↗

Evaluation of transit-time and electromagnetic flow measurement in a chronically instrumented nonhuman primate model

The Physiology Research Branch at Brooks AFB conducts both human and nonhuman primate experiments to determine the effects of microgravity and hypergravity on the cardiovascular system and to identify the particular mechanisms that invoke these responses. Primary investigative efforts in our nonhuman primate model require the determination of total peripheral resistance, systemic arterial compliance, and pressure-volume loop characteristics. These calculations require beat-to-beat measurement of aortic flow. This study evaluated accuracy, linearity, biocompatability, and anatomical features of commercially available electromagnetic (EMF) and transit-time flow measurement techniques. Five rhesus monkeys were instrumented with either EMF (3 subjects) or transit-time (2 subjects) flow sensors encircling the proximal ascending aorta. Cardiac outputs computed from these transducers taken over ranges of 0.5 to 2.0 L/min were compared to values obtained using thermodilution. In vivo experiments demonstrated that the EMF probe produced an average error of 15% (r = .896) and 8.6% average linearity per reading, and the transit-time flow probe produced an average error of 6% (r = .955) and 5.3% average linearity per reading. Postoperative performance and biocompatability of the probes were maintained throughout the study. The transit-time sensors provided the advantages of greater accuracy, smaller size, and lighter weight than the EMF probes. In conclusion, the characteristic features and performance of the transit-time sensors were superior to those of the EMF sensors in this study.

Non-NASA Center↗

Modeling of Cardiovascular Response to Weightlessness

It was the hypothesis of this Project that the Simple lack of hydrostatic pressure in microgravity generates several purely physical reactions that underlie and may explain, in part, the cardiovascular response to weightlessness. For instance, hydrostatic pressure within the ventricles of the heart may improve cardiac performance by promoting expansion of ventricular volume during diastole. The lack of hydrostatic pressure in microgravity might, therefore, reduce diastolic filling and cardiac performance. The change in transmural pressure is possible due to the difference in hydrostatic pressure gradients between the blood inside the ventricle and the lung tissue surrounding the ventricle due to their different densities. On the other hand, hydrostatic pressure within the vasculature may reduce cardiac inlet pressures because of the typical location of the heart above the hydrostatic indifference level (the level at which pressure remains constant throughout changes in gravity). Additional physical responses of the body to changing gravitational conditions may influence cardiovascular performance. For instance, fluid shifts from the lower body to the thorax in microgravity may serve to increase central venous pressure (CVP) and boost cardiac output (CO). The concurrent release of gravitational force on the rib cage may tend to increase chest girth and decrease pedcardial pressure, augmenting ventricular filling. The lack of gravity on pulmonary tissue may allow an upward shifting of lung mass, causing a further decrease in pericardial pressure and increased CO. Additional effects include diuresis early in the flight, interstitial fluid shifts, gradual spinal extension and movement of abdominal mass, and redistribution of circulatory impedance because of venous distention in the upper body and the collapse of veins in the lower body. In this project, the cardiovascular responses to changes in intraventricular hydrostatic pressure, in intravascular hydrostatic pressure and, to a limited extent, in extravascular and pedcardial hydrostatic pressure were investigated. A complete hydraulic model of the cardiovascular system was built and flown aboard the NASA KC-135 and a computer model was developed and tested in simulated microgravity. Results obtained with these models have confirmed that a simple lack of hydrostatic pressure within an artificial ventricle causes a decrease in stroke volume. When combined with the acute increase in ventricular pressure associated with the elimination of hydrostatic pressure within the vasculature and the resultant cephalad fluid shift with the models in the upright position, however, stroke volume increased in the models. Imposition of a decreased pedcardial pressure in the computer model and in a simplified hydraulic model increased stroke volume. Physiologic regional fluid shifting was also demonstrated by the models. The unifying parameter characterizing of cardiac response was diastolic ventricular transmural pressure (DVDELTAP) The elimination of intraventricular hydrostatic pressure in O-G decreased DVDELTAP stroke volume, while the elimination of intravascular hydrostatic pressure increased DVDELTAP and stroke volume in the upright posture, but reduced DVDELTAP and stroke volume in the launch posture. The release of gravity on the chest wall and its associated influence on intrathoracic pressure, simulated by a drop in extraventricular pressure4, increased DVDELTAP ans stroke volume.

Sharp, M. Keith↗

System identification of dynamic closed-loop control of total peripheral resistance by arterial and cardiopulmonary baroreceptors

Prolonged exposure to microgravity in space flight missions (days) impairs the mechanisms responsible for defense of arterial blood pressure (ABP) and cardiac output (CO) against orthostatic stress in the post-flight period. The mechanisms responsible for the observed orthostatic intolerance are not yet completely understood. Additionally, effective counter measures to attenuate this pathophysiological response are not available. The aim of this study was to investigate the ability of our proposed system identification method to predict closed-loop dynamic changes in TPR induced by changes in mean arterial pressure (MAP) and right atrial pressure (RAP). For this purpose we designed and employed a novel experimental animal model for the examination of arterial and cardiopulmonary baroreceptors in the dynamic closed-loop control of total peripheral resistance (TPR), and applied system identification to the analysis of beat-to-beat fluctuations in the measured signals. Grant numbers: NAG5-4989. c 2001. Elsevier Science Ltd. All rights reserved.

Non-NASA Center↗

Phenylephrine-induced elevations in arterial blood pressure are attenuated in heat-stressed humans

To test the hypothesis that phenylephrine-induced elevations in blood pressure are attenuated in heat-stressed humans, blood pressure was elevated via steady-state infusion of three doses of phenylephrine HCl in 10 healthy subjects in both normothermic and heat stress conditions. Whole body heating significantly increased sublingual temperature by ~0.5 degrees C, muscle sympathetic nerve activity (MSNA), heart rate, and cardiac output and decreased total peripheral vascular resistance (TPR; all P < 0.005) but did not change mean arterial blood pressure (MAP; P > 0.05). At the highest dose of phenylephrine, the increase in MAP and TPR from predrug baselines was significantly attenuated during the heat stress [DeltaMAP 8.4 +/- 1.2 mmHg; DeltaTPR 0.96 +/- 0.85 peripheral resistance units (PRU)] compared with normothermia (DeltaMAP 15.4 +/- 1.4 mmHg, DeltaTPR 7.13 +/- 1.18 PRU; all P < 0.001). The sensitivity of baroreflex control of MSNA and heart rate, expressed as the slope of the relationship between MSNA and diastolic blood pressure, as well as the slope of the relationship between heart rate and systolic blood pressure, respectively, was similar between thermal conditions (each P > 0.05). These data suggest that phenylephrine-induced elevations in MAP are attenuated in heat-stressed humans without affecting baroreflex control of MSNA or heart rate.

Non-NASA Center↗

Baroreflex regulation of blood pressure during dynamic exercise

From the work of Potts et al. Papelier et al. and Shi et al. it is readily apparent that the arterial (aortic and carotid) baroreflexes are reset to function at the prevailing ABP of exercise. The blood pressure of exercise is the result of the hemodynamic (cardiac output and TPR) responses, which appear to be regulated by two redundant neural control systems, "Central Command" and the "exercise pressor reflex". Central Command is a feed-forward neural control system that operates in parallel with the neural regulation of the locomotor system and appears to establish the hemodynamic response to exercise. Within the central nervous system it appears that the HLR may be the operational site for Central Command. Specific neural sites within the HLR have been demonstrated in animals to be active during exercise. With the advent of positron emission tomography (PET) and single-photon emission computed tomography (SPECT), the anatomical areas of the human brain related to Central Command are being mapped. It also appears that the Nucleus Tractus Solitarius and the ventrolateral medulla may serve as an integrating site as they receive neural information from the working muscles via the group III/IV muscle afferents as well as from higher brain centers. This anatomical site within the CNS is now the focus of many investigations in which arterial baroreflex function, Central Command and the "exercise pressor reflex" appear to demonstrate inhibitory or facilitatory interaction. The concept of whether Central Command is the prime mover in the resetting of the arterial baroreceptors to function at the exercising ABP or whether the resetting is an integration of the "exercise pressor reflex" information with that of Central Command is now under intense investigation. However, it would be justified to conclude, from the data of Bevegard and Shepherd, Dicarlo and Bishop, Potts et al., and Papelier et al. that the act of exercise results in the resetting of the arterial baroreflex. In addition, if, as we have proposed, the cardiopulmonary baroreceptors primarily monitors and reflexly regulates cardiac filling volume, it would seem from the data of Mack et al. and Potts et al. that the cardiopulmonary baroreceptor is also reset at the beginning of exercise. Therefore, investigations of the neural mechanisms of regulation involving Central Command and cardiopulmonary afferents, similar to those being undertaken for the arterial baroreflex, need to be established.

NASA Discipline Cardiopulmonary↗

Certain cardiovascular indices predict syncope in the postural tachycardia syndrome

Patients with postural tachycardia syndrome (POTS) represent a patient population with orthostatic intolerance; some are prone to syncope, others are not. The underlying neurocardiovascular mechanisms are not completely understood. The current study was undertaken to assess if certain cardiovascular indices are predictive of syncope in POTS. We compared the response to tilt-up and the Valsalva maneuver in four groups: POTS patients who fainted (POTS-f; n = 11;31 +/- 11 years): POTS patients who did not faint (POTS-nf; n = 9; 29 +/- 9 years); normal controls (NLS; n = 13; 39 +/- 11 years); patients with generalized autonomic failure with orthostatic hypotension and syncope (n = 10; 59 +/- 14 years). Beat-to-beat heart rate (HR), systolic arterial pressure, diastolic arterial pressure (DAP) and pulse pressure (PP) were monitored using Finapres. Cardiac output, stroke volume (SV) and end-diastolic volume (EDV), and calculated total peripheral resistance (TPR) were recorded using thoracic electrical bioimpedance. An autonomic reflex screen which quantitates the distribution and severity of autonomic failure was also done. With the patient supine, all POTS patients (POTS-nf; POTS-f) had increased HR (p < 0.001) and reduced SV/EDV (p < 0.001) when compared with NLS. On tilt-up, POTS-f patients were significantly different from both NLS and POTS-nf patients; the most consistent alteration was a fall instead of an increase in TPR; other changes were a greater reduction in PP, a reduction (instead of an increment) in DAP, and a different pattern of changes during the Valsalva maneuver (excessive early phase II, attenuated or absent late phase II). Our results suggest alpha-adrenergic impairment with increased pooling or hypovolemia in POTS-f patients. We conclude that it is possible to identify the mechanism of syncope in POTS patients, and perhaps other patients with orthostatic intolerance and an excessive liability to syncope.

NASA Discipline Number 14-10↗

Mechanisms of Orthostatic Tolerance Improvement Following Artificial Gravity Exposure Differ Between Men and Women

We recently determined that a short exposure to artificial gravity (AG) improved the orthostatic tolerance limit (OTL) of cardiovascularly deconditioned subjects. We now seek to determine the mechanisms of that improvement in these hypovolemic men and women. Methods. We determined the orthostatic tolerance limit (OTL) of 9 men and 8 women following a 90 min exposure to AG compared to 90 min of head down bed rest (HDBR). In both cases (21 days apart), subjects were made hypovolemic (low salt diet plus 20 mg intravenous furosemide). Orthostatic tolerance was determined from a combination of head up tilt and increasing lower body negative pressure until presyncope. Mean values and correlations with OTL were determined for heart rate, blood pressure, stroke volume, cardiac output and peripheral resistance (Finometer), cerebral artery blood velocity (DWL), partial pressure of carbon dioxide (Novametrics) and body segmental impedance (UFI THRIM) were measured during supine baseline, during OTL to presyncope and during supine recovery Results. Orthostatic tolerance of these hypovolemic subjects was significantly greater on the day of AG exposure than on the HDBR day. Regression of OTL on these variables identified significant relationships on the HDBR day that were not evident on the AG day: resting TPR correlated positively while resting cerebral flow correlated negatively with OTL. On both days, women's resting stroke volume correlated positively with orthostatic tolerance. Higher group mean values of stroke volume and cerebral artery flow and lower values of blood pressure, peripheral vascular and cerebrovascular resistance both at control and during OTL testing were observed on the AG day. Even though regression of OTL on resting stroke volume was significant only in women, presyncopal stroke volume reached the same level on each day of study for both men and women while the OTL test lasted 30% longer in men and 22% longer in women. Cerebral artery flow appeared to follow stroke volume and absolute values of cerebral flow did not correlate with the development of presyncope. Women responded to AG exposure with elevated cerebral flow at resting control and throughout the OTL test, implying a loss of autoregulation in deconditioned (hypovolemic) women following AG exposure. Conclusions. Before countermeasures to space flight cardiovascular deconditioning are established, gender differences in cardiovascular responses to orthostatic stress, in general, and to orthostatic stress following exposure to artificial gravity, in particular, need to be determined. Since, in both men and women, a single, acute bout of AG exposure improved orthostatic tolerance, the feasibility of short exposures to AG during longer spaceflights or prior to entry into a gravity (Earth or Mars) environment, should be explored. Given the known beneficial effects of AG on other organ systems, the present study indicates that the positive effects of AG on cardiac stroke volume make AG a likely candidate for maintaining cardiovascular conditioning.

Evans, J. M.↗

Autoregulation of cerebral blood flow in orthostatic hypotension

BACKGROUND AND PURPOSE: We sought to evaluate cerebral autoregulation in patients with orthostatic hypotension (OH). METHODS: We studied 21 patients (aged 52 to 78 years) with neurogenic OH during 80 degrees head-up tilt. Blood flow velocities (BFV) from the middle cerebral artery were continuously monitored with transcranial Doppler sonography, as were heart rate, blood pressure (BP), cardiac output, stroke volume, CO2, total peripheral resistance, and cerebrovascular resistance. RESULTS: All OH patients had lower BP (P<.0001), BFV_diastolic (P<.05), CVR (P<.007), and TPR (P<.02) during head-up tilt than control subjects. In control subjects, no correlations between BFV and BP were found during head-up tilt, suggesting normal autoregulation. OH patients could be separated into those with normal or expanded autoregulation (OH_NA; n=16) and those with autoregulatory failure (OH_AF; n=5). The OH_NA group showed either no correlation between BFV and BP (n=8) or had a positive BFV/BP correlation (R2>.75) but with a flat slope. An expansion of the "autoregulated" range was seen in some patients. The OH_AF group was characterized by a profound fall in BFV in response to a small reduction in BP (mean deltaBP <40 mm Hg; R2>.75). CONCLUSIONS: The most common patterns of cerebral response to OH are autoregulatory failure with a flat flow-pressure relationship or intact autoregulation with an expanded autoregulated range. The least common pattern is autoregulatory failure with a steep flow-pressure relationship. Patients with patterns 1 and 2 have an enhanced capacity to cope with OH, while those with pattern 3 have reduced capacity.

Non-NASA Center↗

Age alters the cardiovascular response to direct passive heating

During direct passive heating in young men, a dramatic increase in skin blood flow is achieved by a rise in cardiac output (Qc) and redistribution of flow from the splanchnic and renal vascular beds. To examine the effect of age on these responses, seven young (Y; 23 +/- 1 yr) and seven older (O; 70 +/- 3 yr) men were passively heated with water-perfused suits to their individual limit of thermal tolerance. Measurements included heart rate (HR), Qc (by acetylene rebreathing), central venous pressure (via peripherally inserted central catheter), blood pressures (by brachial auscultation), skin blood flow (from increases in forearm blood flow by venous occlusion plethysmography), splanchnic blood flow (by indocyanine green clearance), renal blood flow (by p-aminohippurate clearance), and esophageal and mean skin temperatures. Qc was significantly lower in the older than in the young men (11.1 +/- 0.7 and 7.4 +/- 0.2 l/min in Y and O, respectively, at the limit of thermal tolerance; P < 0. 05), despite similar increases in esophageal and mean skin temperatures and time to reach the limit of thermal tolerance. A lower stroke volume (99 +/- 7 and 68 +/- 4 ml/beat in Y and O, respectively, P < 0.05), most likely due to an attenuated increase in inotropic function during heating, was the primary factor for the lower Qc observed in the older men. Increases in HR were similar in the young and older men; however, when expressed as a percentage of maximal HR, the older men relied on a greater proportion of their chronotropic reserve to obtain the same HR response (62 +/- 3 and 75 +/- 4% maximal HR in Y and O, respectively, P < 0.05). Furthermore, the older men redistributed less blood flow from the combined splanchnic and renal circulations at the limit of thermal tolerance (960 +/- 80 and 720 +/- 100 ml/min in Y and O, respectively, P < 0. 05). As a result of these combined attenuated responses, the older men had a significantly lower increase in total blood flow directed to the skin.

Clinical Trial↗

A physiologically based pharmacokinetic (PBPK) model to align dosimetry of the isobutyl metabolic series in rats and humans

Here, we developed a physiologically based pharmacokinetic (PBPK) model in rats and humans for the isobutyl metabolic series including isobutyl acetate, isobutanol, isobutyraldehyde, and isobutyric acid. Chemical manufactures routinely use these compounds as solvents, for chemical synthesis, as potential biofuels, de-icing fluids, and additives for food and/or fragrance in consumer products. Human exposure to isobutyl compounds can occur through inhalation or oral routes. We previously developed a PBPK model for the propyl metabolic series and utilized it as a framework to create the isobutyl PBPK model due to the chemical similarities between the two series. To support model development, we measured in vitro metabolism of isobutyl acetate in rat and human blood and liver S9 fractions. Compared to rats, humans demonstrated faster isobutyl acetate hydrolysis in liver S9 fractions, while the hydrolysis rates in blood were similar between the two species. We used concentrations of isobutyl compounds measured in air and blood from rats exposed to isobutyl acetate and isobutanol as well as other published data to further parameterize the model. Following exposure to either isobutyl acetate or isobutanol, we observed isobutanol concentrations highest among the isobutyl compounds in the blood of rats. Overall, the model accurately predicts measured time course concentrations of isobutyl acetate, isobutanol, and isobutyric acid in available data in rats and humans. Sensitivity analyses identified alveolar ventilation rates, isobutyl metabolism rates, and cardiac output as the most sensitive parameters affecting concentrations of isobutyl compounds in blood. The isobutyl PBPK model enables comparisons of internal dose metrics across various isobutyl compound exposures and species and allows for calculation of equivalent external exposures that result in the same dose metric. Regulators can employ this PBPK model to predict and align internal dose metrics of isobutyl compounds for risk assessment purposes.

2-methyl-1-propanol↗