Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cavity Resonators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Maser cavity servo-tuning system

Two collocated, weakly coupled probes, one loop and one dipole, detect the magnetic and electric fields inside a maser cavity. Signals from the probes are compared in phase, and the signal output from the phase detector is applied to a varactor, the reactance of which is coupled into the cavity by a microwave coupler. Alternatively, the varactor may be placed inside the cavity. Any deviation of phase from 90 deg as detected by the phase detector will then produce an error signal that will change the reactance coupled into the resonant cavity to change its reactance, and thus correct its resonance frequency. An alternative to using two probes is to use a single disk probe oriented to detect both the magnetic and electric fields, and thus provide the error signal directly.

Sydnor, R. L.↗

Frequency, phase, and amplitude changes of the hydrogen maser oscillation

The frequency, the phase, and the amplitude changes of the hydrogen maser oscillation, which are induced by the modulation of the cavity resonant frequency, are considered. The results obtained apply specifically to one of the H-maser cavity autotuning methods which is actually implemented, namely the cavity frequency-switching method. The frequency, the phase, and the amplitude changes are analyzed theoretically. The phase and the amplitude variations are measured experimentally. It is shown, in particular, that the phase of oscillation is subjected to abrupt jumps at the times of the cavity frequency switching, whose magnitude is specified. The results given can be used for the design of a phase-locked loop (PLL) aimed at minimizing the transfer of the phase modulation to the slaved VCXO.

Audoin, Claude↗

A hydrogen maser with cavity auto-tuner for timekeeping

A hydrogen maser frequency standard for timekeeping was worked on at the Shanghai Observatory. The maser employs a fast cavity auto-tuner, which can detect and compensate the frequency drift of the high-Q resonant cavity with a short time constant by means of a signal injection method, so that the long term frequency stability of the maser standard is greatly improved. The cavity auto-tuning system and some maser data obtained from the atomic time comparison.

C. F. Lin↗

A superconducting time-variant filtering system.

Description of a laboratory test facility for studying the tracking capabilities of a superconducting time-varying filter system. An RF signal from an antenna is amplified and fed to a mixer; the IF signal modulates an optical diode, and the emitted light is directed through an optical system onto a high-purity high-resistance semiconductor terminating a quarter-wavelength stub in a lead-plated superconducting cavity. The resulting perturbation in the cavity resonant frequency is proportional to the signal modulation present in the light beam. The narrow-band superconducting cavity is thereby acting as a time-variant filter that tracks the instantaneous signal modulation. SNR improvement on the order of 25 dB can be obtained due to the noise rejection characteristics of such a modulation tracking filter.

Arndt, G. D.↗

Microwave Resonators Containing Diamond Disks

Synthetic diamond dielectric bodies proposed for use in cylindrical resonators helping to stabilize frequencies of some microwave oscillators. Acting in conjunction with metal resonator cavities in which mounted, such dielectric bodies support "whispering-gallery" waveguide modes characterized by desired frequencies of resonance and by electro-magnetic-field configurations limiting dissipation of power on metal surfaces outside dielectric bodies. Performances at room temperature might exceed those of liquid-nitrogen-cooled sapphire-based resonators.

Dick, G. John↗

Measurement of individual hydrometeor absorption cross sections utilizing microwave cavity perturbation techniques

A technique for measurement of individual hydrometeor absorption cross sections is presented. Cross sections are inferred by inserting the hydrometeor into a high Q resonant cavity and measuring the Q perturbation. Tests were conducted in a 10.64 GHz, TM(010) cavity. Absorption cross sections were measured at room temperature for 0.5 to 2.0 mm water drops, and were found to agree with the Rayleigh theory. Cross sections were also measured as a function of temperature, and from these the dielectric loss term lm(-K) was inferred for supercooled water down to -17 C.

Hansman, R. J., Jr.↗

Microwave dielectric measurements of lunar soil with a coaxial line resonator method

A method is given for sensitive dielectric measurements at a series of microwave frequencies using a section of coaxial line. The line is used as a 1-port cavity resonator; it resonates when the electrical length of the center conductor equals 1, 2 . . . , N half-wave lengths. The dielectric properties of an Apollo 17 dried soil sample were measured in vacuum over a temperature range of 173 to 373 K. The relative permittivity and the loss tangent were determined and the frequency dependence was very small. The derivative with respect to temperature, per degree, was 0.00045 for the permittivity and 0.00002 for the loss tangent.

Bussey, H. E.↗

Atomic hydrogen maser active oscillator cavity and bulb design optimization

The performance characteristics and reliability of the active oscillator atomic hydrogen maser depend upon oscillation parameters which characterize the interaction region of the maser, the resonant cavity and atom storage bulb assembly. With particular attention to use of the cavity frequency switching servo (1) to reduce cavity pulling, it is important to maintain high oscillation level, high atomic beam flux utilization efficiency, small spin exchange parameter and high cavity quality factor. It is also desirable to have a small and rigid cavity and bulb structure and to minimize the cavity temperature sensitivity. Curves for a novel hydrogen maser cavity configuration which is partially loaded with a quartz dielectric cylinder and show the relationships between cavity length, cavity diameter, bulb size, dielectric thickness, cavity quality factor, filling factor and cavity frequency temperature coefficient are presented. The results are discussed in terms of improvement in maser performance resulting from particular design choices.

Peters, H. E.↗

Reducing flow-induced resonance in a cavity

A method and system are provided for reducing flow-induced resonance in a structure's cavity. A time-varying disturbance is introduced into the flow along a leading edge of the cavity. The time-varying disturbance can be periodic and can have the same or different frequency of the natural resonant frequency of the cavity. In one embodiment of the system, flaps are mounted flush with the surface of the structure along the cavity's leading edge. A piezoelectric actuator is coupled to each flap and causes a portion of each flap to oscillate into and out of the flow in accordance with the time-varying function. Resonance reduction can be achieved with both open-loop and closed-loop configurations of the system.

Cattafesta, III, Louis N.↗

Off-axis coherently pumped laser

A coherently optically pumped laser system is described. A pump laser beam propagates through a laser medium contained in a degenerate cavity resonator in a controlled multiple round trip fashion in such a way that the unused pump beam emerges from an injection aperture at a different angle from which it enters the resonator. The pump beam is angularly injected off of the central axis of the resonator body whereupon the pump beam alternately undergoes spreading and focusing while pumping the laser medium by a process of resonant absorption. The emergent pump beam can also be used as a second pump beam source by being reinjected back into the cavity or it can be used for pumping another laser.

Koepf, G. A.↗

Numerical Comparison of Active Acoustic and Structural Noise Control in a Stiffened Double Wall Cylinder

The active acoustic and structural noise control characteristics of a double wall cylinder with and without ring stiffeners were numerically evaluated. An exterior monopole was assumed to acoustically excite the outside of the double wall cylinder at an acoustic cavity resonance frequency. Structural modal vibration properties of the inner and outer shells were analyzed by post-processing the results from a finite element analysis. A boundary element approach was used to calculate the acoustic cavity response and the coupled structural-acoustic interaction. In the frequency region of interest, below 500 Hz, all structural resonant modes were found to be acoustically slow and the nonresonant modal response to be dominant. Active sound transmission control was achieved by control forces applied to the inner or outer shell, or acoustic control monopoles placed just outside the inner or outer shell. A least mean square technique was used to minimize the interior sound pressures at the nodes of a data recovery mesh. Results showed that single acoustic control monopoles placed just outside the inner or outer shells resulted in better sound transmission control than six distributed point forces applied to either one of the shells. Adding stiffeners to the double wall structure constrained the modal vibrations of the shells, making the double wall stiffer with associated higher modal frequencies. Active noise control obtained for the stiffened double wall configurations was less than for the unstiffened cylinder. In all cases, the acoustic control monopoles controlled the sound transmission into the interior better than the structural control forces.

Grosveld, Ferdinand W.↗

Ground-Based Investigations with the Cryogenic Hydrogen Maser

The cryogenic hydrogen maser (CHM) developed at the Smithsonian Astrophysical Observatory (SAO) was designed to be functionally similar to SAO room temperature hydrogen masers with appropriate modifications made for operation at cryogenic temperatures. A schematic of the SAO CHM is shown in Figure 1, and a description of this device and its operation follows. A beam of molecular hydrogen is dissociated into atoms at room temperature. The resultant beam of atomic hydrogen is then cooled, magnetically state selected, and focused into a quartz storage bulb centered inside of a microwave cavity resonant with the hydrogen hyperfine transition at 1420 MHz. The quartz storage bulb is coated with a superfluid He-4 film, and both the bulb and cavity are maintained near 0.5 K. The maser signal is coupled out inductively and carried to room temperature via semi-rigid coaxial cable. After passing through a room temperature isolator and preamp, the maser signal is detected with a low-noise heterodyne receiver as used in the room temperature SAO hydrogen masers. The maser temperature is lowered to 0.5 K using a recirculating He-3 refrigerator. This refrigerator consists of several cooling stages: a liquid nitrogen stage at 77 K, a liquid 4He bath at 4.2 K, a pumped He-4 pot at approximately 1.7 K, and the pumped, recirculating He-3 stage at 0.5 K. The atomic hydrogen beam, state selector, storage bulb and cavity are all connected inside a single, maser vacuum chamber (MVC). This space is pumped out from below by a turbo pump. Above the MVC, an inlet to the space allows for the input of flowing superfluid 4He film. External to the MVC is a second, outer vacuum chamber (OVC), maintained for operation of the cryostat and also pumped by a turbo pump. Inside the OVC, there is radiation shielding at 77 K and 1.7 K.

Walsworth, Ronald L.↗

Coupled cavity traveling wave tube with velocity tapering

A coupled cavity traveling wave tube with a velocity taper, which affords beam wave resynchronization and thereby enhances is described. The wave velocity reduction is achieved by reducing the resonant frequencies of the individual resonant cavities as a function of the distance from the electron gun, through changes in internal cavity dimensions. The required changes in cavity dimensions can be accomplished by gradually increasing the cavity radius decreasing the gap length from cavity to cavity. The velocity reduction is carried out without an increase in circuit resistive losses and the upper and lower cut off frequencies are reduced in approximately the same manner.

Connolly, D. J.↗

A Solid State Ultraviolet Lasers Based on Cerium-Doped LiCaAIF(sub 6) Crystal Resonator

We report the first demonstration of a UV laser using a high-Q whispering gallery mode (WGM) resonator of Ce+: LiCaAlF6. We show that WGM resonators from LiCaAlF6 can achieve a Q of 2.6 x 10(sup 7) at UV. We demonstrated a UV laser at 290 nm with a pulsed pump laser at 266 nm. The experiments showed the low pump threshold intensity of 7.5 x 10(sup 9) W/m(sup 2) and slope efficiency of 25%. We have also observed lasing delay dynamics. These results are consistent with our modeling and theoretical estimates, and pave the way for a low threshold cw UV laser using WGM resonator cavity.

Whispering Gallery Mode Resonators↗

Numerical studies of the fluid and optical fields associated with complex cavity flows

Numerical solutions for the flowfield about several cavity configurations have been computed using the Reynolds averaged Navier-Stokes equations. Comparisons between numerical and experimental results are made in two dimensions for free shear layers and a rectangular cavity, and in three dimensions for the transonic aero-window problem of the Stratospheric Observatory for Infrared Astronomy (SOFIA). Results show that dominant acoustic frequencies and magnitudes of the self excited resonant cavity flows compare well with the experiment. In addition, solution sensitivity to artificial dissipation and grid resolution levels are determined. Optical path distortion due to the flow field is modelled geometrically and is found to match the experiment. The fluid field was computed using a diagonalized scheme within an overset mesh framework. An existing code, OVERFLOW, was utilized with the additions of characteristic boundary condition and output routines required for reduction of the unsteady data. The newly developed code is directly applicable to a generalized three dimensional structured grid zone. Details are provided in a paper included in Appendix A.

Atwood, Christopher A.↗

Calligraphic Poling for WGM Resonators

By engineering the geometry of a nonlinear optical crystal, the effective efficiency of all nonlinear optical oscillations can be increased dramatically. Specifically, sphere and disk shaped crystal resonators have been used to demonstrate nonlinear optical oscillations at sub-milliwatt input power when cs light propagates in a Whispering Gallery Mode (WGM) of such a resonant cavity. in terms of both device production and experimentation in quantum optics, some nonlinear optical effects with naturally high efficiency can occult the desired nonlinear scattering process. the structure to the crystal resonator. In this paper, I will discuss a new method for generating poling structures in ferroelectric crystal resonators called calligraphic poling. The details of the poling apparatus, experimental results and speculation on future applications will be discussed.

microsphere↗

Cavity perturbation techniques for measurement of the microwave conductivity and dielectric constant of a bulk semiconductor material.

Cavity perturbation techniques offer a very sensitive and highly versatile means for studying the complex microwave conductivity of a bulk material. A knowledge of the cavity coupling factor in the absence of perturbation, together with the change in the reflected power and the cavity resonance frequency shift, are adequate for the determination of the material properties. This eliminates the need to determine the Q-factor change with perturbation which may lead to appreciable error, especially in the presence of mismatch loss. The measurement accuracy can also be improved by a proper choice of the cavity coupling factor prior to the perturbation.

Eldumiati, I. I.↗

Selected computations of transonic cavity flows

An efficient diagonal scheme implemented in an overset mesh framework has permitted the analysis of geometrically complex cavity flows via the Reynolds averaged Navier-Stokes equations. Use of rapid hyperbolic and algebraic grid methods has allowed simple specification of critical turbulent regions with an algebraic turbulence model. Comparisons between numerical and experimental results are made in two dimensions for the following problems: a backward-facing step; a resonating cavity; and two quieted cavity configurations. In three-dimensions the flow about three early concepts of the stratospheric Observatory For Infrared Astronomy (SOFIA) are compared to wind-tunnel data. Shedding frequencies of resolved shear layer structures are compared against experiment for the quieted cavities. The results demonstrate the progress of computational assessment of configuration safety and performance.

Atwood, Christopher A.↗