Search NASA⌕ Search

SEARCH · Search NASA

Results for “Centrifugation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Separation of gas mixtures by centrifugation

Magnetohydrodynamic (MHD) centrifuge utilizing electric currents and magnetic fields produces a magnetic force which develops supersonic rotational velocities in gas mixtures. Device is superior to ordinary centrifuges because rotation of gas mixture is produced by MHD force rather than mechanical means.

Park, C.↗

Electrophoresis separator combining centrifugal separation

Centrifugal force causes buffer, chosen to be denser than particles, to move outward and particles to move inward. Electrophoresis force can be made to equal centrifugal force. System tends not to be affected by convection and other disturbances that are so troublesome in conventional electrophoresis systems.

Semon, H. W.↗

Some aversive characteristics of centrifugally generated gravity.

The effective weight of rats was manipulated by centrifugation. Two effective weight levels were obtained. In three escape avoidance conditions a lever press produced a change from a base level of 2.1 g to a response level of 1.1 g. In a punishment condition a response produced a change from a 1.1 g level to a 2.1 g level and in an extinction condition responses had no effect on the 2.1 g effective weight level present. All changes took 30 sec and were maintained for an additional 10 sec before a return to base level was initiated. When responses occurred closer together than the 40 sec, they delayed the return to base level by 40 sec. This 40 sec interval is referred to as response-contingent-time. The response rate and amount of response-contingent-time served as the data. The results confirmed previous data that centrifugation is aversive. The results are interpreted as indicating that the aversiveness is attributable to the increase in effective weight, and that rats can discriminate the different angular velocity-radius of rotation combinations used.

Altman, F.↗

Study of the potential for improving the economics of hydrogen liquefaction through the use of centrifugal compressors and the addition of a heavy water plant

An approach to the liquefaction of hydrogen was developed which permits the application of standard centrifugal compressors in place of reciprocating machines. A second fluid, such as propane, is added to the hydrogen prior to compression to form a mixture having a molecular weight much greater than that of hydrogen alone, so that a standard centrifugal compressor can be used. After compression, the mixture is cooled to cryogenic temperature levels where the propane condenses out of the mixture and is separated as a liquid. Since a small amount of deuterium is produced during hydrogen liquefaction, the potential of recovering deuterium and selling it as a co-product was investigated. Deuterium, in the form of heavy water, can be used in certain nuclear reactors as a neutron moderator to reduce the neutron velocity and enhance the probability of neutron collision with uranium nucleii.

Baker, C. R.↗

System analysis of plasma centrifuges and sputtering

System analyses of cylindrical plasma centrifuges are presented, for which the velocity field and electromagnetic fields are calculated. The effects of different electrode geometrics, induced magnetic fields, Hall-effect, and secondary flows are discussed. It is shown that speeds of 10000 m/sec can be achieved in plasma centrifuges, and that an efficient separation of U238 and U235 in uranium plasmas is feasible. The external boundary-value problem for the deposition of sputtering products is reduced to a Fredholm integral equation, which is solved analytically by means of the method of successive approximations.

Hong, S. H.↗

Centrifugal reciprocating compressor

Efficient compressor uses centrifugal force to compress gas. System incorporates two coupled dc motors, each driving separate centrifugal reciprocating-compressor assembly. Motors are synchronized to accelerate and decelerate alternately.

High, W. H.↗

On the characteristics of centrifugal-reciprocating machines

A method of compressing helium gas for cryogenic coolers is presented which uses centrifugal force to reduce the forces on the connecting rod and crankshaft in the usual reciprocating compressor. This is achieved by rotating the piston-cylinder assembly at a speed sufficient for the centrifugal force on the piston to overcome the compressional force due to the working fluid. The rotating assembly is dynamically braked in order to recharge the working space with fluid. The intake stroke consists of decelerating the rotating piston-cylinder assembly and the exhaust stroke consists of accelerating the assembly.

Higa, W. H.↗

Field verification of lateral-torsional coupling effects on rotor instabilities in centrifugal compressors

Lateral and torsional vibration data obtained on a centrifugal compressor train which had shaft instabilities and gear failures is examined. The field data verifies that the stability of centrifugal compressors can be adversely affected by coincidence of torsional natural frequencies with lateral instability frequencies. The data also indicates that excitation energy from gear boxes can reduce stability margins if energy is transmitted either laterally or torsionally to the compressors. The lateral and torsional coupling mechanisms of shaft systems is discussed. The coupling mechanisms in a large industrial compressor train are documented and the potential effect on rotor stability is demonstrated. Guidelines are set forth to eliminate these potential problems by minimizing the interaction of torsional and lateral responses and their effect on rotor stability.

Wachel, J. C.↗

Effects of Ultra-Clean and centrifugal filtration on rolling-element bearing life

Fatigue tests were conducted on groups of 65-millimeter bore diameter deep-groove ball bearings in a MIL-L-23699 lubricant under two levels of filtration. In one test series, the oil cleanliness was maintained at an exceptionally high level (better than a class "000" per NAS 1638) with a 3 micron absolute barrier filter. These tests were intended to determine the "upper limit" in bearing life under the strictest possible lubricant cleanliness conditions. In the tests using a centrifugal oil filter, contaminants of the type found in aircraft engine filters were injected into the filters' supply line at 125 milligrams per bearing-hour. "Ultra-clean" lubrication produced bearing fatigue lives that were approximately twice that obtained in previous tests with contaminated oil using 3 micron absolute filtration and approximately three times that obtained with 49 micron filtration. It was also observed that the centrifugal oil filter had approximately the same effectiveness as a 30 micron absolute filter in preventing bearing surface damage.

Loewenthal, S. H.↗

Effect of weightlessness and centrifugation on red cell survival in rats subjected to space flight

Rats were flown aboard the Soviet biosatellite Cosmos 936 for 18.5 d during August, 1977. Five rats were subjected to near-weightless space flight, as with Cosmos 782, and five rats were subjected to a 1-G force via an on-board centrifuge. These rats and three control groups were injected with 2-(C-14) glycine 19 d preflight. The flight rats were recovered from orbit after 18.5 d of space flight. Erythrocyte hemolysis and lifespan were evaluated in the five groups of rats by quantitation of radioactive carbon monoxide exhaled in the breath which arises from the breakdown of the previously labeled hemoglobin. The results support the previous findings wherein hemolysis was found to increase as a result of weightless space flight. A comparison to the centrifuged animals indicates that artificial gravity attenuates the effect of weightlessness on hemolysis and appears to normalize the hemolytic rate in the early postflight period.

Leon, H. A.↗

Centrifugally driven diffusion of Iogenic plasma

The plasma distribution around Io as measured by Voyager 1 displays an asymmetric discontinuity at Io's orbit that has been suggested to be the signature of centrifugally driven interchange diffusion fed by plasma derived from Io. This hypothesis is explored further and found to be valid. The particular form for the diffusion coefficient appropriate to centrifugally driven turbulence is derived. The nonlinear character of this kind of diffusion is thereby made explicit. Solutions to the nonlinear, time-independent and linearized, time-dependent diffusion equations are given. These display a markedly conservative behavior. The nonlinear, steady state solutions are identical in form to the solutions of the previously studied equation of linear, atmospherically driven diffusion. The linearized, time-dependent solutions exhibit a negative feed-back quality that buffers the response of the density to changes in the source strength. Estimates of the source strength, the diffusion coefficient, and the signal propagation speed are also given.

Siscoe, G. L.↗

Meteor Crater: Energy of formation - Implications of centrifuge scaling

Recent work on explosive cratering has demonstrated the utility of performing subscale experiments on a geotechnic centrifuge to develop scaling rules for very large energy events. The present investigation is concerned with an extension of this technique to impact cratering. Experiments have been performed using a projectile gun mounted directly on the centrifuge rotor to launch projectiles into a suitable soil container undergoing centripetal accelerations in excess of 500 G. The pump tube of a two-stage light-gas gun was used to attain impact velocities of approximately 2 km/sec. The results of the experiments indicate that the energy of formation of any large impact crater depends upon the impact velocity. This dependence, shown for the case of Meteor Crater, is consistent with analogous results for the specific energy dependence of explosives and is expected to persist to impact velocities in excess of 25 km/sec.

Schmidt, R. M.↗

Coil planet centrifugation as a means for small particle separation

The coil planet centrifuge uses a centrifugal force field to provide separation of particles based on differences in sedimentation rates by flow through a rotating coiled tube. Three main separations are considered: (1) single phase fresh sheep and human erythrocytes, (2) single phase fixed heep and human erythrocytes, and (3) electrophoretically enhanced single phase fresh sheep and human erythrocytes.

Herrmann, F. T.↗

Response of amphibian egg cytoplasm to novel gravity orientation and centrifugation

The effects of inversion and centrifugation on the compartmentalization of cytoplasm in Xenopus laevis eggs are investigated experimentally. The rearrangement of yolk-platelet compartments (YPC) characterized by morphology, density, and viscosity differences is studied in fertilized, unfertilized, and unfertilized electrically activated eggs in normal, and inverted positions and with and without centrifugation at 10-183 x g for 5 min. The eggs are fixed and embedded in plastic or paraffin prior to sagittal sectioning (0.5, 4, or 8 microns) and microscopic examination; the results are presented in a diagram and discussed. A density-compartment model combining both animal/vegetal and dorsal/ventral polarities is proposed: YPC determined without gravity orientation during oogenesis respond to both sperm entrance point and gravity after fertilization, and the response involves breaking of the radial symmetry of the egg. It is predicted that Xenopus eggs in a microgravity environment will encounter difficulties in establishing a primary embryonic axis.

Neff, A. W.↗

Centrifugal Generator of Filled Spherical Shells

Centrifugal apparatus produces filled spherical shells for wide range of industrial and scientific applications. Rotating container has radially extending nozzle in which centrifugal force draws liquid shell material from container. Liquid shell material fed from outside container and automatically maintained at fixed level. Along axis of nozzle is tube that connects through rotating seal to source of gas or other filler material. Material-flow and rotation rates adjusted to change bubble size.

Wang, T. G.↗

Artificial gravity studies and design considerations for Space Station centrifuges

The requirements to and capabilities of a Space Station biological facility centrifuge are discussed on the basis of an assessment of the objectives and subjects of future microgravity biological experiments. It is argued that the facility should be capable of both acute and extended chronic exposure of test subjects and biological materials to altered-g loading. In addition, the experimental approaches and equipment for microgravity studies on a Space Station are outlined. Finally, the engineering requirements of such a centrifuge are examined, with consideration of radial gravity gradients, size, and physical access to animals.

Halstead, T. W.↗

Core temperature of tailless rats exposed to centrifugation

The role of the tail in the altered thermoregulation of rats during acute exposure to hypergravity was investigated, using groups of rats of two ages: 55 days (young) and 138 days (old). Rectal and foot temperature changes were measured in intact and tailless rats subjected to 1 h centrifugation of 2.8 G, with preceding (1 h) and following (1-3 h) 1 G periods. At 22 C, the loss of body heat from the tail per se does not measurably contribute to the hypothermia induced by hypergravity. However, the heat loss from the feet was greater in the tailless rats than in the intact rats from the young group of animals, although there was no significant difference between the tailless and intact rats in the old animal group. It is concluded that the inhibition of heat production is a significant factor in the hypothermia of centrifuged tailless rats, as it has been previously shown to be in the intact animals.

Monson, C. B.↗

Centrifuge impact cratering experiments: Scaling laws for non-porous targets

A geotechnical centrifuge was used to investigate large body impacts onto planetary surfaces. At elevated gravity, it is possible to match various dimensionless similarity parameters which were shown to govern large scale impacts. Observations of crater growth and target flow fields have provided detailed and critical tests of a complete and unified scaling theory for impact cratering. Scaling estimates were determined for nonporous targets. Scaling estimates for large scale cratering in rock proposed previously by others have assumed that the crater radius is proportional to powers of the impactor energy and gravity, with no additional dependence on impact velocity. The size scaling laws determined from ongoing centrifuge experiments differ from earlier ones in three respects. First, a distinct dependence of impact velocity is recognized, even for constant impactor energy. Second, the present energy exponent for low porosity targets, like competent rock, is lower than earlier estimates. Third, the gravity exponent is recognized here as being related to both the energy and the velocity exponents.

Schmidt, Robert M.↗