Search NASA⌕ Search

SEARCH · Search NASA

Results for “Charge reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Latitudinal variations of cloud base height and lightning parameters in the tropics

The observed reduction in cloud-to-ground lightning in the new-equational zone is examined from the perspective of the width of the main negative charge region. Thermodynamic observations of cloud base height also show a climatological minimum value in the near-equatorial region. The association of low cloud base with both narrow updrafts and narrow changing zones may impede the bridging of the large air gap to ground, and thereby suppress cloud-to-ground lightning activity. This width dependence may be more important than the approx. 10% variation in height of the freezing level in the encouraging flashes to ground.

Mushtak, V. C.↗

Inhibition of gravitropism in oat coleoptiles by calcium chelation

Some cellular event necessary for gravitropism is inhibited by EGTA without interferring with the overall growth. Calcium relieves this inhibition and demonstrates both that inhibition is reversible and was probably due to a reduction in the ability to free calcium required for one or more at the transduction steps of gravitropism. At the near neutral pH used, EGTA is charged and would not be expected to readily cross the membrane. One of its primary effects, then, is probably the bringing of free calcium in the apoplastic space exterior to the cell membranes.

Roux, S. J.↗

The Effect of ODC-Free Cleaning Techniques on Bearing Lifetimes in the Parched Elastohydrodynamic Regime

A parched elastohydrodynamic rig was used to determine relative bearing lifetimes as a function of cleaning procedures in a series of accelerated tests. Two ODC-free cleaning procedures (super critical CO2 and ultraviolet-ozone) were compared to a CFC-113 control. Bearings (52100 steel) were run in the counter rotating mode (equivalent to 4600 rpm) with a full complement (i.e. no retainer) and a single charge of lubricant (Krytox 143 AC). Test conditions included: an air atmosphere, 445 N load, approx. 1.0 GPa mean Hertz stress. There was approximately a 50% reduction in life with bearings cleaned with UV/ozone and a 70% reduction in life with SFE CO2 when compared to the Freon control. Possible reasons for these decreases in lifetimes are presented.

Jones, William R., Jr.↗

Jovian electron bursts - Correlation with the interplanetary field direction and hydromagnetic waves

The bursts of relativistic electrons detected on Pioneer 10 upstream from Jupiter and within 400 Jovian radii of the planet have been found to be correlated with the interplanetary magnetic field. In three examples, electrons with energies between 3 and 6 MeV escaping from Jupiter's magnetosphere were observed only when the interplanetary magnetic field was along the Jupiter-spacecraft line. Large-amplitude interplanetary waves with characteristic periods of 10 min were found to be well correlated with intervals during which the field was along the Jupiter-spacecraft line. Abrupt changes in the field away from the preferred direction caused equally abrupt terminations of the waves with an accompanying reduction in the electron flux. These results are consistent with propagation of the electrons from Jupiter to Pioneer along the magnetic field lines. Hydromagnetic wave generation by Jovian charged particles, presumably the relativistic electrons themselves, as they travel upstream, appears to be an attractive explanation for the origin of the waves. At the observed frequency, hydromagnetic waves are Doppler-shifted to the gyrofrequency of the relativistic electrons. A plasma instability that appears capable of explaining the observations is a cyclotron overstability that occurs when the velocity of runaway electrons exceeds the velocity of hydromagnetic waves.

Smith, E. J.↗

An Innovation for the Energy Industry

REDOX is an economical energy storage system which promises major reductions in the cost of storing electrical energy. The system is based upon the conversion of chemical energy into electrical energy. 75 percent of the energy used to charge the system is returned. It is flexible and the energy may be stored for long periods. It was developed by Lewis Research Center, who transferred the technology to SOHIO for further development and possible commercialization. Redox could eliminate the use of high quality generator levels and would be particularly valuable to utilities which generate power from coal or nuclear energy.

Source record↗

Solar Powered CO.Sub.2 Conversion

Methods and devices for reducing CO.sub.2 to produce hydrocarbons are disclosed. A device comprises a photoanode capable of splitting H.sub.2O into electrons, protons, and oxygen; an electrochemical cell cathode comprising an electro-catalyst capable of reducing CO.sub.2; H.sub.2O in contact with the surface of the photoanode; CO.sub.2 in contact with the surface of the cathode; and a proton-conducting medium positioned between the photoanode and the cathode. Electrical charges associated with the protons and the electrons move from the photoanode to the cathode, driven in part by a chemical potential difference sufficient to drive the electrochemical reduction of CO.sub.2 at the cathode. A light beam is the sole source of energy used to drive chemical reactions. The photoanode can comprise TiO.sub.2 nanowires or nanotubes, and can also include WO.sub.3 nanowires or nanotubes, quantum dots of CdS or PbS, and Ag or Au nanostructures. The cathode can comprise a conductive gas diffusion layer with nanostructures of an electro-catalyst such as Cu or Co.

Chen, Bin↗

Miniature Focusing Time-of-Flight Mass Spectrometer

An improved miniature time-of-flight mass spectrometer has been developed in a continuing effort to minimize the sizes, weights, power demands, and costs of mass spectrometers for such diverse applications as measurement of concentrations of pollutants in the atmosphere, detecting poisonous gases in mines, and analyzing exhaust gases of automobiles. Advantageous characteristics of this mass spectrometer include the following: It is simple and rugged. Relative to prior mass spectrometers, it is inexpensive to build. There is no need for precise alignment of its components. Its mass range is practically unlimited Relative to prior mass spectrometers, it offers high sensitivity (ability to measure relative concentrations as small as parts per billion). Its resolution is one dalton (one atomic mass unit). An entire mass spectrum is recorded in a single pulse. (In a conventional mass spectrometer, a spectrum is recorded mass by mass.) The data-acquisition process takes only seconds. It is a lightweight, low-power, portable instrument. Although time-of-flight mass spectrometers (TOF-MSs) have been miniaturized previously, their performances have not been completely satisfactory. An inherent adverse effect of miniaturization of a TOF-MS is a loss of resolution caused by reduction of the length of its flight tube. In the present improved TOF-MS, the adverse effect of shortening the flight tube is counteracted by (1) using charged-particle optics to constrain ion trajectories to the flight-tube axis while (2) reducing ion velocities to increase ion flight times. In the present improved TOF-MS, a stream of gas is generated by use of a hypodermic needle. The stream of gas is crossed by an energy-selected, pulsed beam of electrons (see Figure 1). The ions generated by impingement of the electrons on the gas atoms are then focused by three cylindrical electrostatic lenses, which constitute a segmented flight tube. After traveling along the flight tube, the ions enter a charged-particle detector. The output of the detector is fed to a counting circuit to obtain data on the counting rate as a function of time. Inasmuch as time of flight is directly proportional to the ion mass, a plot of the counting rate versus time of flight is equivalent to a mass spectrum (see Figure 2).

Kanik, Isik↗

Energy status and oxidation reduction status in rat liver at high altitude /3.8 km/

Adult male rats were exposed to 3.8-km altitude for intervals ranging from 1 h-60 d. Liver samples were taken under light ether anesthesia and were examined by enzymatic analyses. Within 1-6 h of hypoxic exposure, ATP levels decreased while ADP and AMP levels increased, producing a fall in calculated ATP/ADP and adenylate charge ratios. Concurrently, lactate/pyruvate and alpha-glycerophosphate/dihydroxyacetone phosphate ratios increased markedly. Direct measurements of cellular pyridine nucleotides indicated increased NADH/NAD and NADPH/NADP ratios. Levels of total adenosine phosphates and pyridine nucleotides decreased in a significant accompanying response. Many metabolite levels and calculated ratios returned to near-normal values within 1 week of exposure, indicating secondary intracellular adjustments to hypoxic stress; however, persistence of that stress is reflected in lactate concentrations and both substrate redox ratios. Results support and explore concepts that increased oxidation-reduction status and decreased energy status are primary events during hypoxia.

Reed, R. D.↗

Charged particle and magnetic field research in space

Research completed and in progress is described, related publications and reports are listed, and abstracts of papers and talks on results of the research are given. The charged particle research centered on OGO-5 and OGO-6 electron spectrometer data, and theoretical radiation belt studies. Work on the ATS-1 magnetometer project included development of production data reduction programs, development of spectral analysis procedures, and scientific studies of ULF waves at synchronous orbit. The magnetic fields research also included work on the Mariner project and theoretical studies on the solar wind.

Source record↗

Electric propulsion interactive effects with spacecraft science payloads.

Interactive effects between electric thruster units and a Solar Electric Pioneer (SEP) spacecraft science payload are investigated. Studied effects include magnetic contamination (steady state), electric contamination (steady state and time varying) and particle contamination of regions in and around the spacecraft. Conducted electromagnetic interference is measured for thrusters powered with prototype power processing units and radio frequency interference effects between the thruster and the omnidirectional low gain antenna are determined. Material deposition and transport of thruster propellant ions and atoms and charge exchange metal ions and atoms are also experimentally determined. Large scale environmental effects between the plasma thrust beam and the particles and fields in interplanetary space are discussed. Contaminant reduction techniques are proposed, and both laboratory and in-space interactive effects tests are suggested.

Sellen, J. M., Jr.↗

Controlled method of reducing electrophoretic mobility of macromolecules, particles, or cells

A method of reducing electrophoretic mobility of macromolecules, particles, cells, and other substances is provided which comprises interacting in a conventional electrophoretic separating procedure, the substances with a polymer-linked affinity compound comprised of a hydrophilic neutral polymer such as polyethylene glycol bound to a second component such as a hydrophobic compound, an immunocompound such as an antibody or antibody active fragment, or a ligand such as a hormone, drug, antigen, or a hapten. The reduction of electrophoretic mobility achieved is directly proportional to the concentration of the polymer-linked affinity compound employed, and such reduction can comprise up to 100 percent for particular particles and cells. The present invention is advantageous in that electrophoretic separation can now be achieved for substances whose native surface charge structure had prevented them from being separated by normal electrophoretic means. Depending on the affinity component utilized, separation can be achieved on the basis of the specific/irreversible, specific/reversible, semi-specific/reversible, relatively nonspecific/reversible, or relatively nonspecific/irreversible ligand-substance interactions.

Vanalstine, James M.↗

Space Radiation Cancer Risk Projections for Exploration Missions: Uncertainty Reduction and Mitigation

In this paper we discuss expected lifetime excess cancer risks for astronauts returning from exploration class missions. For the first time we make a quantitative assessment of uncertainties in cancer risk projections for space radiation exposures. Late effects from the high charge and energy (HZE) ions present in the galactic cosmic rays including cancer and the poorly understood risks to the central nervous system constitute the major risks. Methods used to project risk in low Earth orbit are seen as highly uncertain for projecting risks on exploration missions because of the limited radiobiology data available for estimating HZE ion risks. Cancer risk projections are described as a product of many biological and physical factors, each of which has a differential range of uncertainty due to lack of data and knowledge. Monte-Carlo sampling from subjective error distributions represents the lack of knowledge in each factor to quantify risk projection overall uncertainty. Cancer risk analysis is applied to several exploration mission scenarios. At solar minimum, the number of days in space where career risk of less than the limiting 3% excess cancer mortality can be assured at a 95% confidence level is found to be only of the order of 100 days.

Cucinotta, Francis↗

Affinity Electrophoresis Using Ligands Attached To Polymers

In new technique, reduction of electrophoretic mobilities by addition of polyethylene glycol to ligands increases electrophoretic separabilities. In immuno-affinity electrophoresis, modification of ligands extends specificity of electrophoretic separation to particles having surface electric-charge structures otherwise making them electrophoretically inseparable. Modification of antibodies by polyethylene glycol greatly reduces ability to aggregate while enhancing ability to affect electrophoretic mobilities of cells. In hydrophobic-affinity electrophoresis, addition of polyethylene glycol reduces tendency toward aggregation of cells or macromolecules.

Van Alstine, James M.↗

Modeling of Carbon Nanotube Schottky Barrier Reduction for Holes in Air

A model is proposed for the recently observed lower Schottky barrier for holes in air than in vacuum at a metallic electrode - semiconducting carbon nanotube (CNT) junction. In air, the CNT is oxidized. The oxygen molecules on the CNT surface will attract negative charges and will be negatively charged. The negative charges on the solid surface generally enhance the surface dipole and provide stronger electron confinement within the solid. Thus the CNT work function will increase in air. Then the Schottky barrier for holes will have to increase in air according to the standard band-alignment theory, but this is against the experiment. In order to overcome this difficulty, we propose a new Schottky barrier model, assuming that there is a transition region between the electrode and the CNT, where an appreciable potential can drop. We assume that electrodes are placed at the side of the CNT and the contact is formed via the van der Waals interaction. Since the electrode surface is not atomically flat in practical situations, the contact will not be intimate and there will be a transition region before the usual metallic bulk structure starts. In this view, the Schottky barrier is determined not only by the work function difference of the electrodes and the CNT, but also by the potential drop in the transition region. The oxidation increases the potential drop and leads to a lower Schottky barrier for holes. This relation will be demonstrated in a graphical manner by expressing the potential drop as a function of CNT band bending. The potential drop is comparable to the CNT band gap when, e.g., the transition region is about a few Angstroms thick, the oxygen molecule coverage is about 10 %, and an oxygen molecule is charged by about 0.01-0.1 of the unit charge (1-10 % of molecules are charged). The proposed mechanism prevails for both p - and n-CNTs. The model consistently explains the CNT oxidation experiments reported so far.

Yamada, Toshishige↗

Local atomic and electronic structure of oxide/GaAs and SiO2/Si interfaces using high-resolution XPS

The chemical structures of thin SiO2 films, thin native oxides of GaAs (20-30 A), and the respective oxide-semiconductor interfaces, have been investigated using high-resolution X-ray photoelectron spectroscopy. Depth profiles of these structures have been obtained using argon ion bombardment and wet chemical etching techniques. The chemical destruction induced by the ion profiling method is shown by direct comparison of these methods for identical samples. Fourier transform data-reduction methods based on linear prediction with maximum entropy constraints are used to analyze the discrete structure in oxides and substrates. This discrete structure is interpreted by means of a structure-induced charge-transfer model.

Grunthaner, F. J.↗

Advanced high-temperature batteries

The promise of very high specific energy and power was not yet achieved for practical battery systems. Some recent approaches are discussed for new approaches to achieving high performance for lithium/DeS2 cells and sodium/metal chloride cells. The main problems for the development of successful LiAl/FeS2 cells were the instability of the FeS2 electrode, which has resulted in rapidly declining capacity, the lack of an internal mechanism for accommodating overcharge of a cell, thus requiring the use of external charge control on each individual cell, and the lack of a suitable current collector for the positive electrode other than expensive molybdenum sheet material. Much progress was made in solving the first two problems. Reduction of the operating temperatures to 400 C by a change in electrolyte composition has increased the expected life to 1000 cycles. Also, a lithium shuttle mechanism was demonstrated for selected electrode compositions that permits sufficient overcharge tolerance to adjust for the normally expected cell-to-cell deviation in coulombic efficiency. Sodium/sulfur batteries and sodium/metal chloride batteries have demonstrated good reliability and long cycle life. For applications where very high power is desired, new electrolyte coinfigurations would be required. Design work was carried out for the sodium/metal chloride battery that demonstrates the feasibility of achieving high specific energy and high power for large battery cells having thin-walled high-surface area electrolytes.

Nelson, Paul A.↗

Controlled method of reducing electrophoretic mobility of various substances

A method of reducing electrophoretic mobility of macromolecules, particles, cells, and the like is provided. The method comprises interacting the particles or cells with a polymer-linked affinity compound composed of: a hydrophilic neutral polymer such as polyethylene glycol, and an affinity component consisting of a hydrophobic compound such as a fatty acid ester, an immunocompound such as an antibody or active fragment thereof or simular macromolecule, or other ligands. The reduction of electrophoretic mobility achieved is directly proportional to the concentration of the polymer-linked affinity compound employed, and the mobility reduction obtainable is up to 100 percent for particular particles and cells. The present invention is advantageous in that analytical electrophoretic separation can not be achieved for macromolecules, particles, and cells whose native surface charge structure had prevented them from being separated by normal electrophoretic means. Depending on the affinity component utilized, separation can be achieved on the basis of specific/irreversible, specific/reversible, semi-specific/reversible, relatively nonspecific/reversible, or relatively nonspecific/irreversible ligand-substance interactions. The present method is also advantageous in that it can be used in a variety of standard laboratory electrophoresis equipment.

Vanalstine, James M.↗

Ion engine endurance testing at high background pressures

Ion engine endurance testing at vacuum chamber pressures in the low 10 exp -3 Pa range is enabled through the use of a three-grid accelerator system with the decelerator grid biased 50 to 100 volts negative of neutralizer cathode potential. The negative decelerator grid serves to collect the facility induced charge exchange ion current which normally results in rapid erosion of the accelerator grid during testing at elevated vacuum chamber pressures. This screen, accelerator, negative decelerator (SAND) grid configuration enables an order of magnitude reduction in vacuum chamber pumping speeds relative to that required for endurance testing of ion engines with conventional two-grid accelerator systems. A 900-hr test of a 30-cm diameter engine at 6.5 kW and a tank pressure of 3.7 x 10 exp -3 Pa was performed to test the feasibility of the three-grid SAND accelerator system technology. Grid erosion rates from this test are compared to those from a 200-hr test performed with the same discharge chamber, in the same test facility, and at the same background pressure with a conventional two grid accelerator system. The SAND optics resulted in greater than a factor of 100 reduction in accelerator grid erosion rate relative to the two-grid system.

Brophy, John R.↗