Search NASA⌕ Search

SEARCH · Search NASA

Results for “Checking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Numerical simulations used for a validity check on the laser induced photo-detachment diagnostic method in electronegative plasmas

Laser photo-detachment is used as a method to measure or determine the negative ion density and temperature in electronegative plasmas. In essence, the method consists of producing an electropositive channel (negative ion free region) via pulsed laser photo-detachment within an electronegative plasma bulk. Electrostatic probes placed in this channel measure the change in the electron density. A second pulse might be used to track the negative ion recovery. From this, the negative ion density and temperature can be determined. We study the formation and relaxation of the electropositive channel via a two-dimensional Particle-In-Cell/Mote Carlo collision model. The simulation is mainly carried out in a Hydrogen plasma with an electronegativity of α = 1, with a parametric study for α up to 20. The temporal and spatial evolution of the plasma potential and the electron densities shows the formation of a double layer (DL) confining the photo-detached electrons within the electropositive channel. This DL evolves into two fronts that move in the opposite directions inside and outside of the laser spot region. As a consequence, within the laser spot region, the background and photo-detached electron energy distribution function relaxes/thermalizes via collisionless effects such as Fermi acceleration and Landau damping. Moreover, the simulations show that collisional effects and the DL electric field strength might play a non-negligible role in the negative ion recovery within the laser spot region, leading to a two-temperature negative ion distribution. The latter result might have important effects in the determination of the negative ion density and temperature from laser photo detachment diagnostic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Checking the Salpeter enhancement of nuclear reactions at intermediate coupling in asymmetric mixtures

In this study, we investigate the plasma enhancement of nuclear reactions in the intermediate coupling regime using orbital free molecular dynamics (OFMD) simulations. Mixtures of H-Cu and H-Ag serve as prototypes of simultaneous weak and strong couplings due to the charge asymmetry. Of particular importance is the partial ionization of Cu and Ag and the free electron polarization captured by OFMD simulations. By comparing a series of OFMD simulations at various concentrations and constant pressure to multi-component hyper-netted chain (MCHNC) calculations of effective binary ionic mixtures, we set a general procedure for computing enhancement factors. The MCHNC procedure allows extension to very low concentrations (5% or less) and to very high temperatures (few keV) unreachable by the simulations. Lastly, enhancement factors for nuclear reaction rates extracted from the MCHNC approach are compared with the Salpeter theory in the weak and strong coupling regimes, and a new interpolation is proposed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reconstruction of time-dependent coefficients: A check of approximation schemes for non-Markovian convolutionless dissipative generators

We propose a procedure to fully reconstruct the time-dependent coefficients of convolutionless non-Markovian dissipative generators via a finite number of experimental measurements. By combining a tomography-based approach with a proper data sampling, our proposal allows to relate the time-dependent coefficients governing the dissipative evolution of a quantum system to experimentally accessible quantities. The proposed scheme not only provides a way to retrieve the full information about potentially unknown dissipative coefficients, but also, most valuably, can be employed as a reliable consistency test for the approximations involved in the theoretical derivation of a given non-Markovian convolutionless master equation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimentally feasible security check for n-qubit quantum secret sharing

In this article we present a general security strategy for quantum secret sharing (QSS) protocols based on the scheme presented by Hillery, Buzek, and Berthiaume (HBB) [Phys. Rev. A 59, 1829 (1999)]. We focus on a generalization of the HBB protocol to n communication parties thus including n-partite Greenberger-Horne-Zeilinger states. We show that the multipartite version of the HBB scheme is insecure in certain settings and impractical when going to large n. To provide security for such QSS schemes in general we use the framework presented by some of the authors [M. Huber, F. Mintert, A. Gabriel, B. C. Hiesmayr, Phys. Rev. Lett. 104, 210501 (2010)] to detect certain genuine n-partite entanglement between the communication parties. In particular, we present a simple inequality which tests the security.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision check on the triviality of the {phi}{sup 4} theory by a new simulation method

We report precise simulations of {phi}{sup 4} theory in the Ising limit. A recent technique to stochastically evaluate the all-order strong coupling expansion is combined with exact identities in the closely related Aizenman random current representation. In this way estimates of the renormalized coupling close to the continuum limit become possible with unprecedented precision and yet low CPU cost. As a sample application we present results for the unbroken phase of the Ising model in dimensions 3, 4 and 5 and investigate the question of triviality by studying a finite size scaling continuum limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Background check for anomalous like-sign dimuon charge asymmetry

The D0 Collaboration has reported an excess of roughly 1% of {mu}{sup -{mu}-} pairs over {mu}{sup +{mu}+} pairs in pp collisions at a center-of-mass energy {radical}(s)=1.96 GeV at the Fermilab Tevatron, when known backgrounds are subtracted. This excess, if ascribed to CP violation in meson-antimeson mixing of nonstrange or strange neutral B mesons, is about 40 times that expected in the standard model. We propose a null test, based on a tight restriction on the muon impact parameter b, to confirm that this excess is indeed due to B mesons. If the asymmetry is due to anomalous CP violation in B{sub s}-B{sub s} mixing, then a tight restriction on b would increase by a factor 2 the net asymmetry from neutral B mixing, while the sample of dimuons from neutral B decays will be reduced significantly relative to background events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Unitarity check in gravitational Higgs mechanism

The effective field theory of massive gravity has long been formulated in a generally covariant way [N. Arkani-Hamed, H. Georgi, and M. D. Schwartz, Ann. Phys. (N.Y.) 305, 96 (2003).]. Using this formalism, it has been found recently that there exists a class of massive nonlinear theories that are free of the Boulware-Deser ghosts, at least in the decoupling limit [C. de Rham and G. Gabadadze, Phys. Rev. D 82, 044020 (2010).]. In this work we study other recently proposed models that go under the name of 'gravitational Higgs theories' [A. H. Chamseddine and V. Mukhanov, J. High Energy Phys. 08 (2010) 011.]. We show that these models, although seemingly different from the effective field theories of massive gravity, are in fact equivalent to them. Furthermore, based on the results obtained in the effective field theory approach, we conclude that the gravitational Higgs theories need the same adjustment of the Lagrangian to avoid the ghosts. We also show the equivalence between the noncovariant mode decomposition used in the Higgs theories, and the covariant Stueckelberg parametrization adopted in the effective field theories, thus proving that the presence or absence of the ghost is independent of the parametrization used in either theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A priori checking of the light-response and data quality before extended data collection in pump–probe photocrystallography experiments

In picosecond and slower pump–probe diffraction experiments, collection of response–ratio correlation sets prior to full data collection provides an invaluable confirmation of the existence of a light-induced signal prior to full data collection. If a response to light exposure is observed, the quality of the data being collected can be assessed. We present a number of such correlation plots both for synchrotron and in-house pump–probe data collection.

Coppens, Philip↗

Detecting Short Circuits: Post Accident Electric Vehicle Battery Safety Check

Fast and accurate detection of soft short circuits (SCs) in the battery packs of damaged electric vehicles is needed by first responders and mechanics to mitigate the potential risk from battery fires that may occur hours, days, or weeks after an accident. Here, this paper presents an SC-detection algorithm for potentially damaged lithium-ion batteries that works quickly and without a priori knowledge of the battery-pack chemistry, capacity, state of charge, or state of health. The proposed universal SC-detection algorithm is designed to be implemented on an inexpensive handheld device that can connect to and monitor the voltages of all cells in a pack. Transient filtering and linear-quadratic state observation provide estimates of normalized SC current for every cell in the pack. Cells with SC-current estimates outside a sigma-based threshold are detected. Simulations, experiments, and electric vehicle (EV) crash data are used to verify the speed, sensitivity, and accuracy of the method, demonstrating 96% accurate detection of 0.0027 C SCs in under 1 h for 5S cell groups in the lab and no false positives for crashed Volkswagen, Chevrolet, and Tesla vehicles without SCs.

25 - ENERGY STORAGE↗

SU-E-J-47: Development of a High-Precision, Image-Guided Radiotherapy, Multi- Purpose Radiation Isocenter Quality-Assurance Calibration and Checking System

Purpose: To develop a system that can define the radiation isocenter and correlate this information with couch coordinates, laser alignment, optical distance indicator (ODI) settings, optical tracking system (OTS) calibrations, and mechanical isocenter walkout. Methods: Our team developed a multi-adapter, multi-purpose quality assurance (QA) and calibration device that uses an electronic portal imaging device (EPID) and in-house image-processing software to define the radiation isocenter, thereby allowing linear accelerator (Linac) components to be verified and calibrated. Motivated by the concept that each Linac component related to patient setup for image-guided radiotherapy based on cone-beam CT should be calibrated with respect to the radiation isocenter, we designed multiple concentric adapters of various materials and shapes to meet the needs of MV and KV radiation isocenter definition, laser alignment, and OTS calibration. The phantom's ability to accurately define the radiation isocenter was validated on 4 Elekta Linacs using a commercial ball bearing (BB) phantom as a reference. Radiation isocenter walkout and the accuracy of couch coordinates, ODI, and OTS were then quantified with the device. Results: The device was able to define the radiation isocenter within 0.3 mm. Radiation isocenter walkout was within ±1 mm at 4 cardinal angles. By switching adapters, we identified that the accuracy of the couch position digital readout, ODI, OTS, and mechanical isocenter walkout was within sub-mm. Conclusion: This multi-adapter, multi-purpose isocenter phantom can be used to accurately define the radiation isocenter and represents a potential paradigm shift in Linac QA. Moreover, multiple concentric adapters allowed for sub-mm accuracy for the other relevant components. This intuitive and user-friendly design is currently patent pending.

07 ISOTOPE AND RADIATION SOURCES↗

Validation of an in-vivo proton beam range check method in an anthropomorphic pelvic phantom using dose measurements

Purpose: In-vivo dosimetry and beam range verification in proton therapy could play significant role in proton treatment validation and improvements. In-vivo beam range verification, in particular, could enable new treatment techniques one of which could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. This paper reports validation study of an in-vivo range verification method which can reduce the range uncertainty to submillimeter levels and potentially allow for in-vivo dosimetry. Methods: An anthropomorphic pelvic phantom is used to validate the clinical potential of the time-resolved dose method for range verification in the case of prostrate treatment using range modulated anterior proton beams. The method uses a 3 × 4 matrix of 1 mm diodes mounted in water balloon which are read by an ADC system at 100 kHz. The method is first validated against beam range measurements by dose extinction measurements. The validation is first completed in water phantom and then in pelvic phantom for both open field and treatment field configurations. Later, the beam range results are compared with the water equivalent path length (WEPL) values computed from the treatment planning system XIO. Results: Beam range measurements from both time-resolved dose method and the dose extinction method agree with submillimeter precision in water phantom. For the pelvic phantom, when discarding two of the diodes that show sign of significant range mixing, the two methods agree with ±1 mm. Only a dose of 7 mGy is sufficient to achieve this result. The comparison to the computed WEPL by the treatment planning system (XIO) shows that XIO underestimates the protons beam range. Quantifying the exact XIO range underestimation depends on the strategy used to evaluate the WEPL results. To our best evaluation, XIO underestimates the treatment beam range between a minimum of 1.7% and maximum of 4.1%. Conclusions: Time-resolved dose measurement method satisfies the two basic requirements, WEPL accuracy and minimum dose, necessary for clinical use, thus, its potential for in-vivo protons range verification. Further development is needed, namely, devising a workflow that takes into account the limits imposed by proton range mixing and the susceptibility of the comparison of measured and expected WEPLs to errors on the detector positions. The methods may also be used for in-vivo dosimetry and could benefit various proton therapy treatments.

60 APPLIED LIFE SCIENCES↗