Search NASA⌕ Search

SEARCH · Search NASA

Results for “Chips”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Improved On-Chip Measurement of Delay in an FPGA or ASIC

An improved design has been devised for on-chip-circuitry for measuring the delay through a chain of combinational logic elements in a field-programmable gate array (FPGA) or application-specific integrated circuit (ASIC). In the improved design, the delay chain does not include input and output buffers and is not configured as an oscillator. Instead, the delay chain is made part of the signal chain of an on-chip pulse generator. The duration of the pulse is measured on-chip and taken to equal the delay.

Chen, Yuan↗

Microrectenna: A Terahertz Antenna and Rectifier on a Chip

A microrectenna that would operate at a frequency of 2.5 THz has been designed and partially fabricated. The circuit is intended to be a prototype of an extremely compact device that could be used to convert radio-beamed power to DC to drive microdevices (see Figure 1). The microrectenna (see Figure 2) circuit consists of an antenna, a diode rectifier and a DC output port. The antenna consists of a twin slot array in a conducting ground plane (denoted the antenna ground plane) over an enclosed quarter-wavelength-thick resonant cavity (denoted the reflecting ground plane). The circuit also contains a planar high-frequency low-parasitic Schottky-barrier diode, a low-impedance microstrip transmission line, capacitors, and contact beam leads. The entire 3-D circuit is fabricated monolithically from a single GaAs wafer. The resonant cavity renders the slot radiation pattern unidirectional with a half-power beam width of about 65. A unique metal mesh on the rear of the wafer forms the backplate for the cavity but allows the GaAs to be wet etched from the rear surface of the twin slot antennas and ground plane. The beam leads protrude past the edge of the chip and are used both to mount the microrectenna and to make the DC electrical connection with external circuitry. The antenna ground plane and the components on top of it are formed on a 2- m thick GaAs membrane that is grown in the initial wafer MBE (molecular beam epitaxy) process. The side walls of the antenna cavity are not metal coated and, hence, would cause some loss of power; however, the relatively high permittivity (epsilon=13) of the GaAs keeps the cavity modes well confined, without the usual surface-wave losses associated with thick dielectric substrates. The Schottky-barrier diode has the usual submicron dimensions associated with THz operation and is formed in a mesa process above the antenna ground plane. The diode is connected at the midpoint of a microstrip transmission line, which is formed on 1- m-thick SiO (permittivity of 5) laid down on top of the GaAs membrane. The twin slots are fed in phase by this structure. To prevent radio-frequency (RF) leakage past the slot antennas, low-loss capacitors are integrated into the microstrip transmission line at the edges of the slots. The DC current- carrying lines extend from the outer edges of the capacitors, widen approaching the edges of the chip, and continue past the edges of the chip to become the beam leads used in tacking down the devices. The structure provides a self-contained RF to DC converter that works in the THz range.

Siegel, Peter↗

A Spacecraft Housekeeping System-on-Chip in a Radiation Hardened Structured ASIC

Housekeeping systems are essential to health monitoring of spacecraft and instruments. Typically, sensors are distributed across various sub-systems and data is collected using components such as analog-to-digital converters, analog multiplexers and amplifiers. In most cases programmable devices are used to implement the data acquisition control and storage, and the interface to higher level systems. Such discrete implementations require additional size, weight, power and interconnect complexity versus an integrated circuit solution, as well as the qualification of multiple parts. Although commercial devices are readily available, they are not suitable for space applications due the radiation tolerance and qualification requirements. The Housekeeping System-o n-A-Chip (HKSOC) is a low power, radiation hardened integrated solution suitable for spacecraft and instrument control and data collection. A prototype has been designed and includes a wide variety of functions including a 16-channel analog front-end for driving and reading sensors, analog-to-digital and digital-to-analog converters, on-chip temperature sensor, power supply current sense circuits, general purpose comparators and amplifiers, a 32-bit processor, digital I/O, pulse-width modulation (PWM) generators, timers and I2C master and slave serial interfaces. In addition, the device can operate in a bypass mode where the processor is disabled and external logic is used to control the analog and mixed signal functions. The device is suitable for stand-alone or distributed systems where multiple chips can be deployed across different sub-systems as intelligent nodes with computing and processing capabilities.

Suarez, George↗

On-Chip Power-Combining for High-Power Schottky Diode-Based Frequency Multipliers

A 1.6-THz power-combined Schottky frequency tripler was designed to handle approximately 30 mW input power. The design of Schottky-based triplers at this frequency range is mainly constrained by the shrinkage of the waveguide dimensions with frequency and the minimum diode mesa sizes, which limits the maximum number of diodes that can be placed on the chip to no more than two. Hence, multiple-chip power-combined schemes become necessary to increase the power-handling capabilities of high-frequency multipliers. The design presented here overcomes difficulties by performing the power-combining directly on-chip. Four E-probes are located at a single input waveguide in order to equally pump four multiplying structures (featuring two diodes each). The produced output power is then recombined at the output using the same concept.

Chattopadhyay, Goutam↗

On-Chip Microfluidic Components for In Situ Analysis, Separation, and Detection of Amino Acids

The Astrobiology Analytical Laboratory at GSFC has identified amino acids in meteorites and returned cometary samples by using liquid chromatography-electrospray ionization time-of-flight mass spectrometry (LCMS). These organic species are key markers for life, having the property of chirality that can be used to distinguish biological from non-biological amino acids. One of the critical components in the benchtop instrument is liquid chromatography (LC) analytical column. The commercial LC analytical column is an over- 250-mm-long and 4.6-mm-diameter stainless steel tube filled with functionized microbeads as stationary phase to separate the molecular species based on their chemistry. Miniaturization of this technique for spaceflight is compelling for future payloads for landed missions targeting astrobiology objectives. A commercial liquid chromatography analytical column consists of an inert cylindrical tube filled with a stationary phase, i.e., microbeads, that has been functionalized with a targeted chemistry. When analyte is sent through the column by a pressurized carrier fluid (typically a methanol/ water mixture), compounds are separated in time due to differences in chemical interactions with the stationary phase. Different species of analyte molecules will interact more strongly with the column chemistry, and will therefore take longer to traverse the column. In this way, the column will separate molecular species based on their chemistry. A lab-on-chip liquid analysis tool was developed. The microfluidic analytical column is capable of chromatographically separating biologically relevant classes of molecules based on their chemistry. For this analytical column, fabrication, low leak rate, and stationary phase incorporation of a serpentine microchannel were demonstrated that mimic the dimensions of a commercial LC column within a 5 10 1 mm chip. The microchannel in the chip has a 75- micrometer-diameter oval-shaped cross section. The serpentine microchannel has four different lengths: 40, 60, 80, and 100 mm. Functionized microbeads were filled inside the microchannel to separate molecular species based on their chemistry.

Zheng, Yun↗

On-chip Broadband Load Calibrators for Characterizing Transition-Edge Sensor Bolometers

We describe the design and fabrication of on-chip broadband load calibrators for element-by- element and full circuit characterization of transition-edge sensor (TES) bolometers for cosmic microwave background (CMB) polarimetry. Fabricated in a 4 X 4 grid on a 100 mm silicon wafer, the chips allow systematic testing of individual detector circuit elements without the need for an external blackbody source. This in-situ testing approach provides rapid and efficient characterization of various pixel designs in order to optimize the optical efficiency and control of systematic effects of the detectors. In this work, we demonstrate the on-chip calibrators on the Cosmology Large Angular Scale Surveyor (CLASS) W-band pixels. In particular, we investigate the loss on microstrip transmission lines and measure the performance of various designs of TESs, magic-tees, via-less crossovers, and signal terminations. We also test a filter-bank spectrometer with eight resonators spanning 80 – 105 GHz to characterize the spectral response of circuit elements across the detector bandwidth.

Sumit Dahal↗

Venus Surface Environmental Chamber Test of SiC JFET-R Multi-Chip Circuit Board

This poster describes a first attempt to demonstrate a multi-chip prototype lander control and sensor signal digitization electronics circuit board comprised of ten NASA Glenn IC Generation 11 SiC JFET-R IC chips in 460 °C, 9.4 MPa harsh Venus surface conditions. The lander circuit ceased electrical operation prematurely at 107 °C as the Venus chamber heated up. Optical and SEM post-test inspections indicate fatal dielectric cracks occurred on only one of the ten SiC chips.

silicon carbide↗

Setting operating points for circuits in an integrated circuit chip using an integrated voltage regulator power loss model

An apparatus includes an integrated circuit chip with a set of circuits having two or more subsets of circuits; an external voltage regulator separate from the integrated circuit chip; two or more integrated voltage regulators on the integrated circuit chip that each provide an input voltage to a respective subset of the circuits; and a controller. The controller determines, using an integrated voltage regulator power loss model, an electrical power loss for the integrated voltage regulators for a first combination of operating points for the subsets of the circuits. The controller then determines, based on the electrical power loss, a second combination of operating points for the subsets of the circuits that includes an adjustment to an operating point for at least one of the subsets of the circuits that compensates for an electrical power loss of the corresponding integrated voltage regulator. The controller sets an operating point of each of the subsets of the circuits based on the second combination of operating points.

42 ENGINEERING↗

Low-latency NuMI Trigger for the CHIPS-5 Neutrino Detector

The CHIPS R&D project aims to develop affordable water Cherenkov detectors for large-scale underwater installations. In 2019, a 5kt prototype detector CHIPS-5 was deployed in northern Minnesota to study neutrinos generated by the nearby NuMI beam. This contribution presents a dedicated low-latency time distribution system for CHIPS-5 that delivers timing signals from the Fermilab accelerator to the detector with sub-nanosecond precision. Exploiting existing NOvA infrastructure, the time distribution system achieves this only with open-source software and conventional network elements. In a time-of-flight study, the presented system has reliably offered a time budget of $610 \pm 330\text{ ms}$ for on-site triggering. This permits advanced analysis in real-time as well as a novel hardware-assisted active triggering mode, which reduces DAQ computing load and network bandwidth outside triggered time windows.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chip Development Toward 12 bit 10 GSPS Cryogenic ADC for Multiplexed Quantum Readout

This presentation presents the background and plan for the development toward a 12 bit 10 GSPS cryogenic ADC for multiplexed quantum readout. It covers the first two chips that have been taped out and tested. It includes results for those chips and provides some context to plans for the upcoming chip tapeout and the final one to come later.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On-PIC Light Source Integration & Micro-dispensing of Solder Paste for Flip Chip Application

To reach the next level benefits of photonic integrated circuits (PICs), the Integrated Photonic Systems Roadmap-International describes the necessity of either heterogeneous or hybrid integration of light sources [1]. A new approach for hybrid integration is Photonic Wire Bonding where 3D nanolithography is used to pattern a polymer waveguide that connects light sources to PIC waveguides. The waveguides resemble electrical wire bonds and essentially do the same as their electrical counterpart for packaging photonic chips together. In order to reap the full benefits of a photonic wire bonds, the light source must be carefully packaged. In this work I seek to expand RIT’s photonic packaging capability by establishing a packaging process to integrate light sources, specifically an Indium Phosphide distributed feedback lasers and a reflective semiconductor optical amplifiers, directly onto a photonic integrated circuits. Another necessary requirement for PIC packaging is densely integrated electrical connectivity. In this thesis I developed a fine pitch flip chip interconnect technique demonstrated using gold stud bumps in conjunction with micro-dispensed solder paste. This work opens the door to high density photonic flip chip applications. The micro-dispensed solder paste dots having diameters 50-125 µm are currently being tested at a pitch of 150 µm . The gold stud bumps are formed with 1mil gold wire creating bumps with a diameter of 40-60 µm depending on specific parameter values. These capabilities will allow RIT to assemble and test novel photonic integrated devices, cutting down on the time and cost associated with third party assembly and tests facilities. Thereby keeping RIT at the forefront of photonic research.

Wongk, Nicole↗

The design and construction of the Chips water Cherenkov neutrino detector

Chips (CHerenkov detectors In mine PitS) was a prototype large-scale water Cherenkov detector located in northern Minnesota. The main aim of the R&D project was to demonstrate that construction costs of neutrino oscillation detectors could be reduced by at least an order of magnitude compared to other equivalent experiments. This article presents design features of the Chips detector along with details of the implementation and deployment of the prototype. While issues during and after the deployment of the detector prevented data taking, a number of key concepts and designs were successfully demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fungi-on-a-Chip: microfluidic platforms for single-cell studies on fungi

Abstract This review highlights new advances in the emerging field of ‘Fungi-on-a-Chip’ microfluidics for single-cell studies on fungi and discusses several future frontiers, where we envisage microfluidic technology development to be instrumental in aiding our understanding of fungal biology. Fungi, with their enormous diversity, bear essential roles both in nature and our everyday lives. They inhabit a range of ecosystems, such as soil, where they are involved in organic matter degradation and bioremediation processes. More recently, fungi have been recognized as key components of the microbiome in other eukaryotes, such as humans, where they play a fundamental role not only in human pathogenesis, but also likely as commensals. In the food sector, fungi are used either directly or as fermenting agents and are often key players in the biotechnological industry, where they are responsible for the production of both bulk chemicals and antibiotics. Although the macroscopic fruiting bodies are immediately recognizable by most observers, the structure, function, and interactions of fungi with other microbes at the microscopic scale still remain largely hidden. Herein, we shed light on new advances in the emerging field of Fungi-on-a-Chip microfluidic technologies for single-cell studies on fungi. We discuss the development and application of microfluidic tools in the fields of medicine and biotechnology, as well as in-depth biological studies having significance for ecology and general natural processes. Finally, a future perspective is provided, highlighting new frontiers in which microfluidic technology can benefit this field.

59 BASIC BIOLOGICAL SCIENCES↗

Microfluidic Liquid-Liquid Extraction Chip with Integrated Raman Sensors (Phase I and Phase II Final Report)

As demand for electricity continues to increase worldwide, the world’s nuclear power generating capacity will continue to grow. Nuclear power is the most environmentally benign way of producing electricity on a large scale. The long-term successful use of nuclear power, however, is critically dependent upon adequate and safe processing and disposal of spent nuclear fuels. A very important feature of nuclear energy is that spent fuels can be reprocessed to recover fissile and fertile materials that can then be used as fresh fuel for nuclear power plants. The DOE-NE Fuel Cycle Research and Development (FCR&D) is currently developing nuclear material reprocessing technologies. In a typical nuclear fuel reprocessing system, centrifugal contactors are used as liquid-liquid extraction devices where two immiscible liquids are mixed at high speeds using a rotor, which creates a fine dispersion of droplets of organic phase in an aqueous phase that contains the analyte. Understanding the extraction efficiency at these contactors through modeling and simulation is important in the development of reprocessing technologies and the optimization of current technologies such as the PUREX process. The outcome of this program will be a liquid-liquid microfluidic flow cell chip with embedded spectroscopic sensors for the analysis of extracted analytes. This device will be useful in the optimization of new fuel reprocessing schemes as well as existing reprocessing processes by providing a microfluidic modeling platform to optimize extraction parameters. The Phase I and Phase II work developed a microfluidic chip design that allows integration of Raman and absorption fiber optic probes and successfully demonstrated the feasibility of using Raman and absorption probes to detect key analytes that partition into the aqueous and organic phases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VLSI design of turbo decoder for integrated communication system on a chip applications

A high-throughput low-power turbo decoder core has been developed for integrated communication system applications such as satellite communications, wireless LAN, digital TV, cable modem, Digital Video Broadcast (DVB), and xDSL systems. The turbo decoder is based on convolutional constituent codes, which outperform all other Forward Error Correction techniques. This turbo decoder core is parameterizable and can be modified easily to fit any size for advanced communication system-on-chip products. The turbo decoder core provides Forward Error Correction of up to 15 Mbits/sec on a 0.13-micron CMOS FPGA prototyping chip at a power of 0.1 watts.

turbo decoder↗

Wireless Capacitive Pressure Sensor With Directional RF Chip Antenna for High Temperature Environments

This paper presents the design, fabrication and characterization of a wireless capacitive pressure sensor with directional RF chip antenna that is envisioned for the health monitoring of aircraft engines operating in harsh environments. The sensing system is characterized from room temperature (25 C) to 300 C for a pressure range from 0 to 100 psi. The wireless pressure system consists of a Clapp-type oscillator design with a capacitive MEMS pressure sensor located in the LC-tank circuit of the oscillator. Therefore, as the pressure of the aircraft engine changes, so does the output resonant frequency of the sensing system. A chip antenna is integrated to transmit the system output to a receive antenna 10 m away.The design frequency of the wireless pressure sensor is 127 MHz and a 2 increase in resonant frequency over the temperature range of 25 to 300 C from 0 to 100 psi is observed. The phase noise is less than minus 30 dBcHz at the 1 kHz offset and decreases to less than minus 80 dBcHz at 10 kHz over the entire temperature range. The RF radiation patterns for two cuts of the wireless system have been measured and show that the system is highly directional and the MEMS pressure sensor is extremely linear from 0 to 100 psi.

Pressure sensor↗

Flip chip packaging of a MEMS neuro-prosthetic system

A joint research team from California Institute of Technology and Jet Propulsion Laboratory is developing a fully miniaturized, smart implantable neuro-prosthetic system, by combining integrated electronics with Micro Electro Mechanical Structure (MEMS) based electrode arrays. The packaging group of this project team has been tasked with designing and fabricating a package to interface electrically between a MEMS electrode array, capable of extracting signals from brain, and an electronic chip, capable of providing on chip conditioning/processing of extracted data, while delivering the output data to a detector located outside the body.

flip↗

Tailored Micromagnet Sorting Gate for Simultaneous Multiple Cell Screening in Portable Magnetophoretic Cell‐On‐Chip Platforms

Abstract Conventional magnetophoresis techniques for manipulating biocarriers and cells predominantly rely on large‐scale electromagnetic systems, which is a major obstacle to the development of portable and miniaturized cell‐on‐chip platforms. Herein, a novel magnetic engineering approach by tailoring a nanoscale notch on a disk micromagnet using two‐step optical and thermal lithography is developed. Versatile manipulations are demonstrated, such as separation and trapping, of carriers and cells by mediating changes in the magnetic domain structure and discontinuous movement of magnetic energy wells around the circumferential edge of the micromagnet caused by a locally fabricated nano‐notch in a low magnetic field system. The motion of the magnetic energy well is regulated by the configuration of the nanoscale notch and the strength and frequency of the magnetic field, accompanying the jump motion of the carriers. The proposed concepts demonstrate that multiple carriers and cells can be manipulated and sorted using optimized nanoscale multi‐notch gates for a portable magnetophoretic system. This highlights the potential for developing cost‐effective point‐of‐care testing and lab‐on‐chip systems for various single‐cell‐level diagnoses and analyses.

36 MATERIALS SCIENCE↗