Search NASA⌕ Search

SEARCH · Search NASA

Results for “Circulating Water System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Two-phase flow measurements and observations in a cooling panel of the reactor cavity cooling system

The analysis of the flow behavior within a cooling panel of a scaled water-cooled reactor cavity cooling system has been performed supported by high-resolution measurements of the void fraction at the risers’ outlet. The results have shown a stable, symmetric distribution of the flow through the risers during subcooled boiling conditions, characterized by small, slow bubbles with average void fraction lower than 0.3 for all risers. As the temperature increased to saturation, flow distribution appeared strongly asymmetrical and unstable, with peaks of void fraction as high as 0.9. Large, faster bubbles were observed during these peaks, immediately followed by flow of subcooled liquid water. Flow stagnation and inversion has also been observed. The high resolution void fraction results, complemented by the measurements of the coolant flow rate and temperatures, not only have further described the behavior of the system under hypothetical accident conditions, but represent a unique set of data to support the validation of system-level codes, and more advanced computational tools.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Numerical Study of Hypoxia in Chesapeake Bay Using an Unstructured Grid Model: Validation and Sensitivity to Bathymetry Representation

A three-dimensional unstructured-grid hydrodynamic and water quality model (Semi-implicit Cross-scale Hydroscience Intergrated System Model-Integrated Compartment Model) is applied successfully for Chesapeake Bay. The model is validated with observations of salinity, chlorophyll-a, dissolved oxygen, nutrients, and phytoplankton productions from the year 1991 to 1995 for the mainstem and some major tributaries, based on multiple model skill scores. Model experiments are conducted to test the importance of having (1) an accurate representation of bathymetry to correctly predict hypoxia and other processes and (2) a high-resolution model grid for tributaries to correctly simulate water quality variables. Further, comparison with the model experiment results with bathymetry smoothing indicates that bathymetry smoothing, as commonly used for many systems, changes the stratification and lateral circulation pattern, resulting in more salt intrusion into shallow water regions, and an increase in the freshwater age. Consequently, a model with bathymetry smoothing can lead to an unrealistic prediction of the distribution of hypoxia and phytoplankton production. Local grid refinement shows significant improvement of model simulations on local stratification and water quality variables. Overall, the use of high-resolution unstructured grid model leads to a faithful representation of the complex geometry, and thus a seamless cross-scale capability for simulating water quality processes in the Bay including tributaries and tidal creeks.

54 ENVIRONMENTAL SCIENCES↗

Effect of Glacial/Interglacial Recharge Conditions on Flow of Meteoric Water Through Deep Orogenic Faults: Insights Into the Geothermal System at Grimsel Pass, Switzerland

Many meteoric-recharged, fault-hosted geothermal systems in amagmatic orogenic belts have been active through the Pleistocene glacial/interglacial climate fluctuations. The effects of such climate-induced recharge variations on fluid flow patterns and residence times of the thermal waters are complex and may influence how the geothermal and mineralization potential of the systems are evaluated. We report systematic thermal–hydraulic simulations designed to reveal the effects of recharge variations, using a model patterned on the orogenic geothermal system at Grimsel Pass in the Swiss Alps. Fault-bound circulation of meteoric water through the Grimsel fault is driven to depths of ~10 km by the high alpine topography. Simulations suggest that the current single pass flow is typical of interglacial periods, during which 1) meteoric recharge into the fault is high (above tens of centimeters per year), 2) conditions are at or somewhat below the critical Rayleigh number, and 3) the hydraulic connectivity along the fault plane is extensive (an extent of at least 10 km into increasingly higher terrain is required to explain the 10 km penetration depth). The subcritical condition constrains the bulk fault permeability to < 1e-14 m2. In contrast, the limited recharge during the numerous Pleistocene glaciation events likely induced a layered flow system with single pass flow confined to shallow depths while non-Rayleigh convection occurred in the deep fault. The same layering can be observed at low aspect ratios (length/depth) of the fault plane, when the available recharge area limits the flux through the fault.

58 GEOSCIENCES↗

Feasibility of Development of Geothermal Deep Direct-Use District Heating and Cooling system at West Virginia University Campus-Morgantown, WV

The Morgantown campus of West Virginia University (WVU) is uniquely positioned to host the first geothermal deep direct-use district heating and cooling (GDHC) system in the eastern United States. While much of the eastern United States does not have elevated heat flow, the Morgantown region of West Virginia is unique in exhibiting sufficient temperatures at the depth of a formation, the Tuscarora, which is expected to support a desirable flow rate of geofluid. Temperature and flow rate were identified in the 2006 MIT Future of Geothermal Energy Report to be the two most critical factors in minimizing the cost of geothermal energy. The WVU campus site offers surface demand coupled with the potential subsurface viability. Specifically, the existing district heating and cooling system that is in use year round will be leveraged. Absorption chilling systems are used to cool the campus in the summer and provide hot water circulating heat in the winter. Our overall project objectives are to 1) collect local information on these critical factors to understand the uncertainty and reduce the risk associated with developing the geothermal resource for use in a WVU campus GDHC system, and 2) complete an optimized design for the GDHC system by minimizing the delivered Levelized Cost of Heat (LCOH). A Tuscarora geological model was built based on core analysis and permeability measurements using data from nearby wells. This geological model is then translated into a reservoir model. iTOUGH2/EOS1 is used to simulate the subsurface portion of a GDHC system using two well configurations: 1) a pair of vertical wells, and 2) a pair of horizontal wells. The performance of both configurations is evaluated based on achievable flow rates and production fluid temperatures; the recommended well configuration is selected based on the expected GDHC system performance. The thermal breakthrough and reservoir productivity increased for horizontal well configuration however, the well-head LCOH for vertical well horizontal well configuration is higher than vertical wells due to the additional cost of horizontal drilling. To minimize the delivered LCOH, we perform an integrated surface-to-subsurface optimization of the full GDHC system. The economic and performance analysis of the GDHC system is evaluated for two cases: 1) using existing district heating and cooling facilities, and 2) by converting the current WVU campus steam infrastructure to a hot water system. The optimized GDHC system will be selected by minimizing the LCOH over these two possible configurations.

15 GEOTHERMAL ENERGY↗

Case Study for the ARRA-funded GSHP Demonstration at Furman University

With funding provided by the American Recovery and Reinvestment Act, 26 ground source heat pump (GSHP) projects were competitively selected in 2009 to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. One of the selected demonstration projects was proposed by Furman University for ten student housing buildings—the North Village located on the campus in Greeneville, South Carolina. All ten buildings are identical in floor plan and construction. Each building is conditioned by an identical GSHP system consisting of 25 water-to-air heat pump (WAHP) units, a closed-loop vertical ground heat exchanger (GHX) installed under an adjacent parking lot, and two redundant 7.5 hp variable-speed pumps to circulate water through the GHX and the WAHPs. The actual performance of the GSHP systems is analyzed with available measured data for 2014. The annual energy performance is compared with a baseline scenario in which the building is conditioned by air-source heat pumps (ASHPs) with the minimum allowed efficiencies specified in ASHRAE Standard 90.1-2013 (SEER 13 for cooling and 7.8 HSPF for heating) and supplemental electric heaters. The comparison is made in terms of energy savings, operating cost savings, cost-effectiveness, and environmental benefits. Finally, limitations in conducting this analysis are identified and recommendations for further improving the operational efficiency of the GSHP systems are made.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cost analysis of oxygen recovery systems

Report is made of the cost analysis of four leading oxygen recovery subsystems which include two carbon dioxide reduction subsystems and two water electrolysis subsystems, namely, the solid polymer electrolyte and the circulating KOH electrolyte. The four oxygen recovery systems were quantitatively evaluated. System characteristics, including process flows, performance, and physical characteristics were also analyzed. Additionally, the status of development of each of the systems considered and the required advance technology efforts required to bring conceptual and/or pre-prototype hardware to an operational prototype status were defined. Intimate knowledge of the operations, development status, and capabilities of the systems to meet space mission requirements were found to be essential in establishing the cost estimating relationships for advanced life support systems.

Yakut, M. M.↗

The Effect of Internal Variability on Ocean Temperature Adjustment in a Low-Resolution CESM Initial Condition Ensemble

Due to its large heat capacity and circulation, the ocean contributes significantly to global heat uptake, global heat transport, spatial temperature patterns, and variability. Quantifying ocean heat uptake across different temporal and spatial scales is important to quantify Earth's climate response to anthropogenic warming. Here we evaluate ocean adjustment time scales from two different fully coupled climate model ensembles using the Community Earth System Model. Both ensembles use the same model version, anthropogenic and natural forcings, and coupling configurations, but we initialize the ensembles in two different ways: (1) sampling joint internal variability of the ocean–atmosphere system (unique atmosphere and ocean conditions) and (2) sampling the internal variability of the atmosphere only (unique atmosphere, identical ocean conditions). Uncertainty due to internal variability is used as a proxy to quantify the time scales of ocean temperature adjustment at different depths and basins in Community Earth System Model. Time scales of equilibration are longer in the deep ocean than the upper ocean, highlighting the vertical structure of dynamic adjustment. The Atlantic equilibrates on shorter time scales (82 years above 1,000 m, 140 years below 1,000 m) relative to the Pacific (106 years above 1,000 m, 444 years below 1,000 m) in Community Earth System Model due to the large North Atlantic Deep Water formation and strong overturning circulation in the Atlantic. These results have broad implications for analyzing internal climate variability, ocean adjustment, and drift in global coupled model experiments and intercomparisons.

54 ENVIRONMENTAL SCIENCES↗

Water cycle and its management for plant habitats at reduced pressures

Experimental and mathematical models were developed for describing and testing temperature and humidity parameters for plant production in bioregenerative life support systems. A factor was included for analyzing systems operating at low (10-101.3 kPa) pressure to reduce gas leakage and structural mass (e.g., inflatable greenhouses for space application). The expected close relationship between temperature and relative humidity was observed, along with the importance of heat exchanger coil temperature and air circulation rate. The presence of plants in closed habitats results in increased water flux through the system. Changes in pressure affect gas diffusion rates and surface boundary layers, and change convective transfer capabilities and water evaporation rates. A consistent observation from studies with plants at reduced pressures is increased evapotranspiration rates, even at constant vapor pressure deficits. This suggests that plant water status is a critical factor for managing low-pressure production systems. The approach suggested should help space mission planners design artificial environments in closed habitats.

NASA Center KSC↗

From Theory to Practice: Feasibility Study of a Thermal Microgrid at a DoD Installation: Preprint

Advanced district thermal energy systems, also known as thermal microgrids, can electrify and decarbonize urban districts in a highly efficient way, but adoption of such systems, especially in the US, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degree F) (15- 25 degree C) temperatures, and water-source heat pumps at connected buildings to boost or lower the temperature for space conditioning and domestic hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to unlocking the full potential of thermal microgrids for energy savings, decarbonization, and resiliency. This paper will do that, by reporting on preliminary results from a feasibility study of a thermal microgrid, and illustrating the process of conceptual design to seek the best possible performance, within the many constraints of existing buildings. The feasibility study focuses on a cluster of existing buildings, including a grocery store, big box style retail store, motel, and clinic, at a US Department of Defense installation in Germany. The study will assess the performance of a pilot-scale thermal microgrid serving those buildings, in terms of energy, emissions, and life cycle cost, and assess practical considerations (such as building retrofits and scalability) for future implementation. A significant opportunity exists for waste heat recovery from refrigeration at the grocery store (more than offsetting the entire building s space heating load in terms of waste heat availability), and modeling of the proposed thermal microgrid will assess the benefits of the waste heat integration. The moderate operating temperatures of thermal microgrids facilitate the integration of waste heat from a variety of sources, and the networks allow waste heat to be shared amongst buildings in proximity. Along with results on expected energy and emissions performance, as well as waste heat integration, the paper will assess implications of load diversity on system performance. The paper will also discuss the process of evaluating existing building HVAC systems for compatibility with a thermal microgrid, including the feasibility of lower heating hot water temperatures compatible with currently-available water-to-water heat pumps. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for decarbonization and energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Hypoxia and Sensitivity to Nutrient Pollution in Salish Sea

We report that increasing levels of nutrients, persistent hypoxia, harmful algal blooms, and increased frequency of fish kills are degrading the ecological health of the Salish Sea. An improved version of a diagnostic hydrodynamic and biogeochemical model (nutrients, phytoplankton, carbon, dissolved oxygen, pH) of the Salish Sea has been developed with the ability to simulate characteristic circulation and water quality features. Sensitivity tests were conducted to assess the responsiveness of the system to land-based (rivers and wastewater sources) nutrient loading. The influence of Fraser River on the magnitude of estuarine exchange with the Pacific Ocean and nearshore habitat was examined given that it contributes nearly half of the total freshwater discharged to the Salish Sea. A large region of hypoxia in Hood Canal that extends over 30–40 km during its peak was reproduced and attributed primarily to the existence of a two-layer classic fjord-type circulation and a nearly stagnant deep bottom layer that occupies nearly 60% of the water column. Nitrate mass in the euphotic zone from land-based and oceanic sources is depleted to near-zero limiting levels during summer. Under such conditions, the Salish Sea is responsive to changes in nutrient loads entering the euphotic zone directly. Lastly, a hypothetical scenario involving the elimination of land-based nutrient sources results in notable water-quality improvement, featuring a reduction in algal biomass (≈5.4%), reduction in sediment oxygen demand (≈17.1%), and significant reduction in hypoxic area (≈39%) and exposure in area-days to bottom layer hypoxia (≈62%) within the Salish Sea.

54 ENVIRONMENTAL SCIENCES↗

From Theory to Practice: Feasibility Study of a Thermal Microgrid at a DoD Installation

Advanced district thermal energy systems, also known as thermal microgrids, can meet the energy needs of urban districts in a highly efficient way, but adoption of such systems, especially in the United States, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degrees F; 15-25 degrees C) temperatures, and water-source heat pumps at connected buildings are used to boost or lower the temperature for space conditioning and service hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to accelerating their adoption. This paper aims to contribute to that by reporting preliminary results from a feasibility study of a thermal microgrid at a U.S. Department of Defense installation and illustrating the process of conceptual design to seek the best possible performance within the many constraints of existing buildings. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for resilience and energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Review of Pump Package Assembly Anomalies and Demonstration to Gain Motor Controller Replacement Capability

The International Space Station (ISS) generates heat within the US modules from systems used to operate the station, maintain crew health, and conduct science experiments in the orbiting laboratory. The Internal Thermal Control System (ITCS) collects this heat in water loops and transfers it to the external ammonia system for rejection to space. The ITCS uses six Pump Package Assemblies (PPA) as the motive force to circulate the water within the Lab, Node 2, and Node 3 (Node 1 is parasitic to the Lab and Node 3 ITCS loops). In the life of ISS, 3 PPAs have had to be replaced and 2 PPAs are currently showing signs of degradation. The first PPA to fail in 2003 was due to early coolant chemistry issues; the remaining pump failures and current pump degradations are determined to be related to the Pump/Fan Motor Controller (PFMC), with their individual signatures all being unique to this point. The PFMC of one of the failed PPAs was returned and testing confirmed its sub-components to be the root cause of the PPA failure. Due to the relative size and weight of the standalone PFMC in comparison to the integrated assembly, it is desired, from a launch and on-orbit stowage perspective, to replace the PFMC component of the degraded PPA instead of the entire PPA. The PPA was not designed for this capability, so on the ground demonstrations are planned using crew tools to show that the PFMC can be replaced on-orbit while maintaining full functionality. This paper will focus on the signatures of the two most recent PPA failures and the two PPAs showing signs of degradation, in addition to presenting the findings from the PFMC demonstration effort.

Aaron Rodriguez↗

A Review of Pump Package Assembly Anomalies and Demonstration to Gain Motor Controller Replacement Capability

The International Space Station (ISS) generates heat within the US modules from systems used to operate the station, maintain crew health, and conduct science experiments in the orbiting laboratory. The Internal Thermal Control System (ITCS) collects this heat in water loops and transfers it to the external ammonia system for rejection to space. The ITCS uses six Pump Package Assemblies (PPA) as the motive force to circulate the water within the Lab, Node 2, and Node 3 (Node 1 is parasitic to the Lab and Node 3 ITCS loops). In the life of ISS, 3 PPAs have had to be replaced and 2 PPAs are currently showing signs of degradation. The first PPA to fail in 2003 was due to early coolant chemistry issues; the remaining pump failures and current pump degradations are determined to be related to the Pump/Fan Motor Controller (PFMC), with their individual signatures all being unique to this point. The PFMC of one of the failed PPAs was returned and testing confirmed its sub-components to be the root cause of the PPA failure. Due to the relative size and weight of the standalone PFMC in comparison to the integrated assembly, it is desired, from a launch and on-orbit stowage perspective, to replace the PFMC component of the degraded PPA instead of the entire PPA. The PPA was not designed for this capability, so on the ground demonstrations are planned using crew tools to show that the PFMC can be replaced on-orbit while maintaining full functionality. This paper will focus on the signatures of the two most recent PPA failures and the two PPAs showing signs of degradation, in addition to presenting the findings from the PFMC demonstration effort.

Aaron Rodriguez↗

Thermally Anisotropic Composites for Improving the Energy Efficiency of Building Envelopes

This article describes a novel application of thermal anisotropy for improving the energy efficiency of building envelopes. The current work was inspired by existing research on improved heat dissipation in electronics using thermal anisotropy. Past work has shown that thermally anisotropic composites (TACs) can be created by the alternate layering of two dissimilar, isotropic materials. Here, a TAC consisting of alternate layers of rigid foam insulation and thin, high-conductivity aluminum foil was investigated. The TAC was coupled with copper tubes with circulating water that acted as a heat sink and source. The TAC system was applied to a conventional wood-framed wall assembly, and the energy benefits were investigated experimentally and numerically. For experimental testing, large scale test wall specimens were built with and without the TAC system and tested in an environmental chamber under simulated diurnal hot and cold weather conditions. Component-level and whole building numerical simulations were performed to investigate the energy benefits of applying the TAC system to the external walls of a typical, single-family residential building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dissipation Scaled Internal Wave Drag in a Global Heterogeneously Coupled Internal/External Mode Total Water Level Model

This study showcases a global, heterogeneously coupled total water level system wherein salinity and temperature outputs from a coarser-resolution (~12 km) ocean general circulation model are used to calculate density-driven terms within a global, higher-resolution (~2.5 km) depth-averaged total water level model. We demonstrate that the inclusion of baroclinic forcing in the barotropic model requires modification of the internal wave drag term to prevent excess degradation of tidal results compared to the barotropic model. By scaling the internal tide dissipation by an easy to calculate dissipation ratio, the resulting heterogeneously coupled model has complex root mean square errors (RMSE) of 2.27 cm in the deep ocean and 12.16 cm in shallow waters for the M 2 tidal constituent. While this represents a 10%–20% deterioration as compared to the barotropic model, the improvements in total water level prediction more than offset this degradation. Global median RMSE compared to observations of total water levels, 30-day sea levels, and non-tidal residuals improve by 1.86 (18.5%), 2.55 (42.5%), and 0.36 (5.3%) cm respectively. The drastic improvement in model performance highlights the importance of including density-driven effects within global hydrodynamic models and will help to improve the results of both hindcasts and forecasts in modeling extreme and nuisance flooding. With only an 11% increase in model run time compared to the fully barotropic total water level model, this approach paves the way for high resolution coastal water level and flood models to be used alongside climate models, improving operational forecasting of total water levels.

Blakely, Coleman Peter [University of Notre Dame, ↗

Solar heating and hot water system installed at Shoney's Restaurant, North Little Rock, Arkansas

A solar heating system designed to supply a major portion of the space and water heating requirements for a restaurant is described. The restaurant has a floor space of approximately 4,650 square feet and requires approximate 1500 gallons of hot water daily. The solar energy system consists of 1,428 square feet of Chamberlain flat plate liquid collector subsystem, and a 1500 gallon storage subsystem circulating hot water producing 321 x 10 to the 6th power Btu/Yr (specified) building heating and hot water heating.

Source record↗

Influence of Sea-Ice Anomalies on Antarctic Precipitation Using Source Attribution in the Community Earth System Model

We conduct sensitivity experiments using a general circulation model that has an explicit water source tagging capability forced by prescribed composites of pre-industrial sea-ice concentrations (SICs) and corresponding sea surface temperatures (SSTs) to understand the impact of sea-ice anomalies on regional evaporation, moisture transport and source–receptor relationships for Antarctic precipitation in the absence of anthropogenic forcing. Surface sensible heat fluxes, evaporation and column-integrated water vapor are larger over Southern Ocean (SO) areas with lower SICs. Changes in Antarctic precipitation and its source attribution with SICs have a strong spatial variability. Among the tagged source regions, the Southern Ocean (south of 50∘ S) contributes the most (40 %) to the Antarctic total precipitation, followed by more northerly ocean basins, most notably the South Pacific Ocean (27%), southern Indian Ocean (16 %) and South Atlantic Ocean (11 %). Comparing two experiments prescribed with high and low pre-industrial SICs, respectively, the annual mean Antarctic precipitation is about 150 Gt yr−1 (or 6 %) more in the lower SIC case than in the higher SIC case. This difference is larger than the model-simulated interannual variability in Antarctic precipitation (99 Gt yr−1). The contrast in contribution from the Southern Ocean, 102 Gt yr−1, is even more significant compared to the interannual variability of 35 Gt yr−1 in Antarctic precipitation that originates from the Southern Ocean. The horizontal transport pathways from individual vapor source regions to Antarctica are largely determined by large-scale atmospheric circulation patterns. Vapor from lower-latitude source regions takes elevated pathways to Antarctica. In contrast, vapor from the Southern Ocean moves southward within the lower troposphere to the Antarctic continent along moist isentropes that are largely shaped by local ambient conditions and coastal topography. This study also highlights the importance of atmospheric dynamics in affecting the thermodynamic impact of sea-ice anomalies associated with natural variability on Antarctic precipitation. Our analyses of the seasonal contrast in changes of basin-scale evaporation, moisture flux and precipitation suggest that the impact of SIC anomalies on regional Antarctic precipitation depends on dynamic changes that arise from SIC–SST perturbations along with internal variability. The latter appears to have a more significant effect on the moisture transport in austral winter than in summer.

Wang, Hailong↗

Solar-Heated and Cooled Office Building--Columbus, Ohio

Final report documents solar-energy system installed in office building to provide space heating, space cooling and domestic hot water. Collectors mounted on roof track Sun and concentrate rays on fluid-circulating tubes. Collected energy is distributed to hot-water-fired absorption chiller and space-heating and domestic-hot-water preheating systems.

Source record↗