Search NASA⌕ Search

SEARCH · Search NASA

Results for “Coefficient of variation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Experimental investigation of propfan aeroelastic response in off-axis flow with mistuning

Measured vibratory strain amplitudes from off-axis flow are compared for the blades of two, 8-bladed propfan model rotors with mistuning. One rotor had inherent mistuning. The other was intentionally mistuned by replacing every other blade of the first rotor with a blade of same geometry but different frequencies and mode shapes. The data shows that the intentional mistuning had a beneficial effect on the aeroelastic response of the propfan motors for a wide range of off-axis flow angles, blade pitch angles, and rotational speeds. Statistical trends of blade strain amplitudes are compared for both the rotors in terms of the ratio of the maximum to the mean and the coefficient of variation.

Mehmed, Oral↗

The validation of a human force model to predict dynamic forces resulting from multi-joint motions

The development and validation is examined of a dynamic strength model for humans. This model is based on empirical data. The shoulder, elbow, and wrist joints were characterized in terms of maximum isolated torque, or position and velocity, in all rotational planes. This data was reduced by a least squares regression technique into a table of single variable second degree polynomial equations determining torque as a function of position and velocity. The isolated joint torque equations were then used to compute forces resulting from a composite motion, in this case, a ratchet wrench push and pull operation. A comparison of the predicted results of the model with the actual measured values for the composite motion indicates that forces derived from a composite motion of joints (ratcheting) can be predicted from isolated joint measures. Calculated T values comparing model versus measured values for 14 subjects were well within the statistically acceptable limits and regression analysis revealed coefficient of variation between actual and measured to be within 0.72 and 0.80.

Pandya, Abhilash K.↗

Direct measurement of capillary blood pressure in the human lip

In this study, we developed and tested a new procedure for measuring microcirculatory blood pressures above heart level in humans. Capillary and postcapillary venule blood pressures were measured directly in 13 human subjects by use of the servonulling micropressure technique adapted for micropuncture of lip capillaries. Pressure waveforms were recorded in 40 separate capillary vessels and 14 separate postcapillary venules over periods ranging from 5 to 64 s. Localization and determination of capillary and postcapillary vessels were ascertained anatomically before pressure measurements. Capillary pressure was 33.2 +/- 1.5 (SE) mm Hg in lips of subjects seated upright. Repeated micropunctures of the same vessel gave an average coefficient of variation of 0.072. Postcapillary venule pressure was 18.9 +/- 1.6 mm Hg. This procedure produces a direct and reproducible means of measuring microvascular blood pressures in a vascular bed above heart level in humans.

Parazynski, S. E.↗

Correlation between strength properties in standard test specimens and molded phenolic parts

This report describes an investigation of the tensile, flexural, and impact properties of 10 selected types of phenolic molding materials. The materials were studied to see in what ways and to what extent their properties satisfy some assumptions on which the theory of strength of materials is based: namely, (a) isotropy, (b) linear stress-strain relationship for small strains, and (c) homogeneity. The effect of changing the dimensions of tensile and flexural specimens and the span-depth ratio in flexural tests were studied. The strengths of molded boxes and flexural specimens cut from the boxes were compared with results of tests on standard test specimens molded from the respective materials. The nonuniformity of a material, which is indicated by the coefficient of variation, affects the results of tests made with specimens of different sizes and tests with different methods of loading. The strength values were found to depend on the relationship between size and shape of the molded specimen and size and shape of the fillers. The most significant variations observed within a diversified group of materials were found to depend on the orientation of fibrous fillers. Of secondary importance was the dependence of the variability of test results on the pieces of filler incorporated into the molding powder as well as on the size of the piece. Static breaking strength tests on boxes molded from six representative phenolic materials correlated well with falling-ball impact tests on specimens cut from molded flat sheets. Good correlation was obtained with Izod impact tests on standard test specimens prepared from the molding materials. The static breaking strengths of the boxes do not correlate with the results of tensile or flexural tests on standard specimens.

MATERIALS, MONSANTO RESINOX↗

Investigation of a Nonlinear Control System

A discontinuous variation of coefficients of the differential equation describing the linear control system before nonlinear elements are added is studied in detail. The nonlinear feedback is applied to a second-order system. Simulation techniques are used to study performance of the nonlinear control system and to compare it with the linear system for a wide variety of inputs. A detailed quantitative study of the influence of relay delays and of a transport delay is presented.

Flugge-Lotz, I↗

The use of designed experiments in the process development of continuous propellant mixing

A continuous mix pilot plant was constructed at Aerojet Propulsion Division in Sacramento, California to develop a robust propellant mixing process for the full scale plant that was to be built at the NASA Advanced Solid Rocket Motor facility Yellow Creek, Mississippi. The plant was used to conduct dozens of subsystem and full system mixing tests for evaluation of equipment, processing methods, and control schemes for later use at the production plant. As a culmination to this work, a series of designed experiments were conducted using an eight run Taguchi analysis with four factors at two levels each to determine the primary effect of processing parameters on propellant ballistic and mechanical properties. The factors examined in these runs included the propellant production rate (454 (1000) and 622 kg/hr (1371 Ib/hr)), the product temperature out of the mixer (49 (120) and 63 deg C (145 deg F)), mixer screw speed (75 and 90 rpm), and the deaerator excess capacity (20 and 80 percent). Measured response variables included the uncured and cured density, Crawford Bomb liquid strand burning rates, and selected mechanical properties. The experiment revealed that several of the response variables displayed significant changes from run-to-run with the product temperature being the single most important factor. After concluding this experiment, a twenty-six hour confirmation run was conducted to verify the conclusions reached in the designed experiment. The extended run produced over 12,250 kgs (27,000 lbs) of propellant meeting all of the pre-run targeted properties including density (1.803 g/cc (0.065 lb/in(exp 3)) with a 0.12 percent coefficient of variation (CV) at 25 deg C (77 deg F)), liquid strand burn rate (0.889 cm/s (0.350 in/s) with a 0.69 percent CV at 4210 KPa (610 psig), 15.6 deg C (60 deg F)), nominal maximum stress (828 KPa (120 psig) with a 2.84 percent CV, S&E at 25 deg C (77 deg F), 5.08 cm/min (2 in/min)), strain at nominal maximum (47.4 percent with a 3.96 percent CV), and initial tangent modulus (5349 KPa (775 psig) with a 7.26 percent CV).

Campbell, J. A.↗

Responses of heart rate and blood pressure to KC-135 hyper-gravity

Many investigators have clarified the effects of hyper gravitational-inertial forces (G) upon the cardiovascular system, using the centrifugal apparatus with short rotating radius. We investigated the cardiovascular responses to KC-135 hyper-G flight with negligibly small angular velocity. Six normal, healthy subjects 29 to 40 years old (5 males and 1 female) took part in this experiment. Hyper gravitational-inertial force was generated by the KC-135 hyper-G flight, flown in a spiral path with a very long radius of 1.5 miles. Hyper-G was sustained for 3 minutes with 1.8 +Gz in each session and was repeatedly exposed to very subject sitting on a chair 5 times. The preliminary results of blood pressure and R-R interval are discussed. An exposure of 1.8 +Gz stress resulted in a remarkable increase of systolic and diastolic blood pressure, while the pulse pressure did not change and remained equal to the control level regardless of an exposure of hyper-G. These results in blood pressure indicate an increase of resistance in the peripheral vessels, when an exposure of hyper-G was applied. The R-R interval was calculated from ECG. R-R interval in all subjects was changed but not systematically, and R-R interval became obviously shorter during the hyper-G period than during the 1 +Gz control period although R-R interval varied widely in some cases. The coefficient of variation of R-R interval was estimated to determine the autonomic nerve activity, but no significant change was detectable.

Satake, Hirotaka↗

Mineral identification and mapping of hydrothermal alteration zones using high-spectral resolution images (AVIRIS)

High-spectral resolution images (AVIRIS) of the cuprite mining area were used to evaluate atmospheric calibration algorithms and test several mineral mapping techniques. Four scene normalization techniques were used: (1) the flat-field method, (2) the internal average reflectance method, (3) the empirical line method, and (4) the atmospheric absorption removal method (ATREM). The algorithms were evaluated in terms of their spectral interpret- ability and their ability to remove both solar irradiance and atmospheric absorption features, noise, and artifacts. Noise was quantified by calculating the coefficient of variation of the spectra, and spectral interpretability was quantified by calcu- lating a difference spectrum (eg, laboratory spectrum minus pixel spectrum) for areas with known occurrences of clay minerals. These difference spectra were useful in evaluating the degree of removal of atmospheric features. The empirical line method produced the best calibration results. Mineral mapping as done using (1) color-composites of bands on the shoulders and centers of expected absorption features, (2) color-coded spectra, and (3) spectral angle mapping.

Van Der Meer, Freek D.↗

Experiment K-7-31: Studies of Vestibular Primary Afferents and Eye Movements in Normal, Hypergravity and Hypogravity - Axon Cosmos Flight 2044

Fourteen days of active head movements in microgravity appear to modify the gain and neural adaptation properties of the horizontal semicircular canals in the rhesus monkey. This is the first demonstration of adaptive plasticity in the sensory receptor. Reversing prisms, for example, do not modify the gain of the primary afferent response. Pulse yaw rotation, sinusoidal rotation, and sum of sinusoidal rotation testing during the first day following recovery revealed that the gain of a sample of afferents was significantly greater than the gain derived from afferent responses obtained during pre-flight and control monkey testing. There was no strong evidence of tilt sensitivity in the sample of afferents that we tested either during the pre-flight or control tests or during the first day post-flight. Two irregular afferents tested on postflight day 2 showed changes with tilt but the responses were not systematic. The spontaneous discharge did not change following flight. Mean firing rate and coefficient of variation remained constant during the post flight tests and was near the value measured during pre flight tests. The change in gain of horizontal canal afferents might be adaptive. The animals were required to look at a target for food. This required active head and eye movements. Active head movements have been shown to be hypometric and eye movements have been shown to be hypermetric during the first few days of past Cosmos flights (see introduction). It might be that the increased gain in the horizontal semicircular canals permit accurate target acquisition during hypometric head movements by driving the eyes to greater angles for smaller angles of head movement. The mechanism by which the semicircular canals recalibrate (increase their gain) is unknown. The efferent vestibular system is a logical candidate. Horizontal nystagmus during rotation about an earth vertical axis with the horizontal semicircular canals in the plane of rotation produced the same response during postflight day 1 and post-flight day 9. But when the head was pitched down 45? the nystagmus slow phase velocity was greater and the duration was about twice during post-flight day 1. Apparently, this response involving the interaction of the horizontal and vertical semicircular canals and the otoliths did not recalibrate during post-flight day 1. The 'DC' bias of the slow phase velocity of the horizontal nystagmus during constant velocity horizontal axis rotation was roughly 4 times for one flight monkey and roughly 2 times for the other on post-flight day 1 compared to post-flight day 9. These results suggest that the otolith mediated response during constant velocity rotation also did not recalibrate on post-flight day 1.

Correia, M. J.↗

Mode 1 and Mode 2 Analysis of Graphite/Epoxy Composites Using Double Cantilever Beam and End-Notched Flexure Tests

The critical strain energy release rates associated with debonding of the adhesive bondlines in graphite/epoxy IM6/3501-6 interlaminar fracture specimens were investigated. Two panels were manufactured for this investigation; however, panel two was layed-up incorrectly. As a result, data collected from Panel Two serves no real purpose in this investigation. Double Cantilever Beam (DCB) specimens were used to determine the opening Mode I interlaminar fracture toughness, G1(sub c), of uni-directional fiber re-inforced composites. The five specimens tested from Panel One had an average value of 946.42J/sq m for G1(sub c) with an acceptable coefficient of variation. The critical strain energy release rate, G2(sub c), for initiation of delamination under inplane shear loading was investigated using the End-Notched Flexure (ENF) Test. Four specimens were tested from Panel One and an average value of 584.98J/sq m for G2(sub c) was calculated. Calculations from the DCB and ENF test results for Panel One represent typical values of G1(sub c) and G2(sub c) for the adhesive debonding in the material studied in this investigation.

Hufnagel, Kathleen P.↗

Estimation of Slow Crack Growth Parameters for Constant Stress-Rate Test Data of Advanced Ceramics and Glass by the Individual Data and Arithmetic Mean Methods

The two estimation methods, individual data and arithmetic mean methods, were used to determine the slow crack growth (SCG) parameters (n and D) of advanced ceramics and glass from a large number of room- and elevated-temperature constant stress-rate ('dynamic fatigue') test data. For ceramic materials with Weibull modulus greater than 10, the difference in the SCG parameters between the two estimation methods was negligible; whereas, for glass specimens exhibiting Weibull modulus of about 3, the difference was amplified, resulting in a maximum difference of 16 and 13 %, respectively, in n and D. Of the two SCG parameters, the parameter n was more sensitive to the estimation method than the other. The coefficient of variation in n was found to be somewhat greater in the individual data method than in the arithmetic mean method.

Choi, Sung R.↗

A Statistical Simulation Approach to Safe Life Fatigue Analysis of Redundant Metallic Components

This paper introduces a dual active load path fail-safe fatigue design concept analyzed by Monte Carlo simulation. The concept utilizes the inherent fatigue life differences between selected pairs of components for an active dual path system, enhanced by a stress level bias in one component. The design is applied to a baseline design; a safe life fatigue problem studied in an American Helicopter Society (AHS) round robin. The dual active path design is compared with a two-element standby fail-safe system and the baseline design for life at specified reliability levels and weight. The sensitivity of life estimates for both the baseline and fail-safe designs was examined by considering normal and Weibull distribution laws and coefficient of variation levels. Results showed that the biased dual path system lifetimes, for both the first element failure and residual life, were much greater than for standby systems. The sensitivity of the residual life-weight relationship was not excessive at reliability levels up to R = 0.9999 and the weight penalty was small. The sensitivity of life estimates increases dramatically at higher reliability levels.

Matthews, William T.↗

Coral Pigments: Quantification Using HPLC and Detection by Remote Sensing

Widespread coral bleaching (loss of pigments of symbiotic dinoflagellates), and the corresponding decline in coral reef health worldwide, mandates the monitoring of coral pigmentation. Samples of the corals Porites compressa and P. lobata were collected from a healthy reef at Puako, Hawaii, and chlorophyll (chl) a, peridinin, and Beta-carotene (Beta-car) were quantified using reverse-phase high performance liquid chromatography (HPLC). Detailed procedures are presented for the extraction of the coral pigments in 90% acetone, and the separation, identification, and quantification of the major zooxanthellar pigments using spectrophotometry and a modification of the HPLC system described by Mantoura and Llewellyn (1983). Beta-apo-8-carotenal was found to be inadequate as in internal standard, due to coelution with chl b and/or chl a allomer in the sample extracts. Improvements are suggested, which may result in better resolution of the major pigments and greater accuracy in quantification. Average concentrations of peridinin, chl a, and Beta-car in corals on the reef were 5.01, 8.59, and 0.29, micro-grams/cm(exp 2), respectively. Average concentrations of peridinin and Beta-car did not differ significantly between the two coral species sampled; however, the mean chl a concentration in P. compressa specimens (7.81 ,micro-grams/cm(exp 2) was significantly lower than that in P. lobata specimens (9.96 11g/cm2). Chl a concentrations determined spectrophotometrically were significantly higher than those generated through HPLC, suggesting that spectrophotometry overestimates chl a concentrations. The average ratio of chl a-to-peridinin concentrations was 1.90, with a large (53%) coefficient of variation and a significant difference between the two species sampled. Additional data are needed before conclusions can be drawn regarding average pigment concentrations in healthy corals and the consistency of the chl a/peridinin ratio. The HPLC pigment concentration values contribute to the limited database of pigment concentrations in healthy corals, from which quantitative definitions of 'healthy' vs. 'bleached' coral may emerge. They also serve as ground-truth, corresponding to fluorescence data collected from the reef at Puako using airborne remote sensing of laser induced fluorescence. Fluorescence spectra from several overflights using the NASA AOL (airborne oceanographic lidar) system show consistent chlorphyll fluorescence peaks around 685 nm, as well as consistence peaks in the 400-600 nm range which may emanate from granules in the coral tissue. These data, along with results from previous studies of coral fluorescence, suggest that remote sensing of laser-induced fluorescence may become a rapid and efficient means of monitoring coral pigmentation and coral reef bleaching.

Cottone, Mary C.↗

Passive, Direct-Read Monitoring System for Selective Detection and Quantification of Hydrogen Chloride

Monitoring the exposure of an employee to hydrogen chloride or hydrochloric acid in the presence of other acids has been a challenge to the industrial hygiene community. The capability of a device to differentiate the levels of acid vapors would allow for more accurate determinations of exposure and therefore improved occupational health. In this work, a selective direct-read colorimetric badge system was validated for Short Term Exposure Limit (STEL) monitoring of hydrogen chloride. The passive colorimetric badge system consists of a direct reading badge and a color scale. The badge has a coated indicator layer with a diffusive resistance in the shape of an exclamation mark. An exclamation mark will appear if hydrogen chloride is present in the atmosphere at concentrations at or above 2.0 ppm. By using the color scale, the intensity of the color formed on the badge can be further quantified up to 25 ppm. The system was validated according to a protocol based on the NIOSH Protocol for the Evaluation of Passive Monitors. The badge was exposed to relative humidities ranging from 11% to 92%, temperatures ranging from 7 C to 400 C and air velocities ranging from 5 cm/sec to 170 cm/sec. All experiments were conducted in a laboratory vapor generation system. Hydrofluoric acid, nitric acid, sulfuric acid, chlorine, hydrogen sulfide and organic acids showed no effect on the performance of the hydrogen chloride monitoring system. The passive badge and color scale system exceeded the accuracy requirements as defined by NIOSH. At ambient conditions, the mean coefficient of variation was 10.86 and the mean bias was 1.3%. This data was presented previously at the American Industrial Hygiene Conference and Exposition in Toronto, Canada in June 1999.

Chapman, K. B.↗

Reliability Analysis and Reliability-Based Design Optimization of Circular Composite Cylinders Under Axial Compression

This report describes the preliminary results of an investigation on component reliability analysis and reliability-based design optimization of thin-walled circular composite cylinders with average diameter and average length of 15 inches. Structural reliability is based on axial buckling strength of the cylinder. Both Monte Carlo simulation and First Order Reliability Method are considered for reliability analysis with the latter incorporated into the reliability-based structural optimization problem. To improve the efficiency of reliability sensitivity analysis and design optimization solution, the buckling strength of the cylinder is estimated using a second-order response surface model. The sensitivity of the reliability index with respect to the mean and standard deviation of each random variable is calculated and compared. The reliability index is found to be extremely sensitive to the applied load and elastic modulus of the material in the fiber direction. The cylinder diameter was found to have the third highest impact on the reliability index. Also the uncertainty in the applied load, captured by examining different values for its coefficient of variation, is found to have a large influence on cylinder reliability. The optimization problem for minimum weight is solved subject to a design constraint on element reliability index. The methodology, solution procedure and optimization results are included in this report.

Rais-Rohani, Masoud↗

Reliability Sensitivity Analysis and Design Optimization of Composite Structures Based on Response Surface Methodology

This report discusses the development and application of two alternative strategies in the form of global and sequential local response surface (RS) techniques for the solution of reliability-based optimization (RBO) problems. The problem of a thin-walled composite circular cylinder under axial buckling instability is used as a demonstrative example. In this case, the global technique uses a single second-order RS model to estimate the axial buckling load over the entire feasible design space (FDS) whereas the local technique uses multiple first-order RS models with each applied to a small subregion of FDS. Alternative methods for the calculation of unknown coefficients in each RS model are explored prior to the solution of the optimization problem. The example RBO problem is formulated as a function of 23 uncorrelated random variables that include material properties, thickness and orientation angle of each ply, cylinder diameter and length, as well as the applied load. The mean values of the 8 ply thicknesses are treated as independent design variables. While the coefficients of variation of all random variables are held fixed, the standard deviations of ply thicknesses can vary during the optimization process as a result of changes in the design variables. The structural reliability analysis is based on the first-order reliability method with reliability index treated as the design constraint. In addition to the probabilistic sensitivity analysis of reliability index, the results of the RBO problem are presented for different combinations of cylinder length and diameter and laminate ply patterns. The two strategies are found to produce similar results in terms of accuracy with the sequential local RS technique having a considerably better computational efficiency.

Rais-Rohani, Masoud↗

Soil Sampling Techniques For Alabama Grain Fields

Characterizing the spatial variability of nutrients facilitates precision soil sampling. Questions exist regarding the best technique for directed soil sampling based on a priori knowledge of soil and crop patterns. The objective of this study was to evaluate zone delineation techniques for Alabama grain fields to determine which method best minimized the soil test variability. Site one (25.8 ha) and site three (20.0 ha) were located in the Tennessee Valley region, and site two (24.2 ha) was located in the Coastal Plain region of Alabama. Tennessee Valley soils ranged from well drained Rhodic and Typic Paleudults to somewhat poorly drained Aquic Paleudults and Fluventic Dystrudepts. Coastal Plain s o i l s ranged from coarse-loamy Rhodic Kandiudults to loamy Arenic Kandiudults. Soils were sampled by grid soil sampling methods (grid sizes of 0.40 ha and 1 ha) consisting of: 1) twenty composited cores collected randomly throughout each grid (grid-cell sampling) and, 2) six composited cores collected randomly from a -3x3 m area at the center of each grid (grid-point sampling). Zones were established from 1) an Order 1 Soil Survey, 2) corn (Zea mays L.) yield maps, and 3) airborne remote sensing images. All soil properties were moderately to strongly spatially dependent as per semivariogram analyses. Differences in grid-point and grid-cell soil test values suggested grid-point sampling does not accurately represent grid values. Zones created by soil survey, yield data, and remote sensing images displayed lower coefficient of variations (8CV) for soil test values than overall field values, suggesting these techniques group soil test variability. However, few differences were observed between the three zone delineation techniques. Results suggest directed sampling using zone delineation techniques outlined in this paper would result in more efficient soil sampling for these Alabama grain fields.

Thompson, A. N.↗

Evaluation of two fiber optic-based solar collection and distribution systems for advanced space life support

Growing plants in an enclosed controlled environment is crucial in developing bioregenerative life-support systems (BLSS) for space applications. The major challenge currently facing a BLSS is the extensive use of highly energy-intensive electric light sources, which leads to substantial energy wastes through heat dissipations by these lamps. An alternative lighting strategy is the use of a solar irradiance collection, transmission, and distribution system (SICTDS). Two types of fiber optic-based SICTDS, a Fresnel-lens Himawari and a parabolic-mirror optical waveguide (OW) lighting system, were evaluated. The overall efficiency for the OW SICTDS of 40.5% exceeded by 75% that for the Himawari of 23.2%. The spectral distributions of the light delivered by the Himawari and the OW SICTDS were almost identical and had practically no difference from that of terrestrial solar radiation. The ratios of photosynthetically active radiation (PAR) to total emitted radiation (k) of 0.39 +/- 0.02 for the Himawari and 0.41 +/- 0.04 for the OW SICTDS were statistically indistinguishable, were not significantly different from that of 0.042 +/- 0.01 for terrestrial solar radiation, and were comparable to that of 0.35 for a high-pressure sodium (HPS) lamp. The coefficients of variation (CV) of 0.34 and 0.39 for PPF distributions, both at 50 mm X 50 mm square grid arrays, corresponding to the Himawari and the OW SICTDS, respectively, were comparable with each other but were both significantly greater than the CV of 0.08 corresponding to the HPS lamp. The average fresh weight or dry weight of lettuce grown in the solar chamber with either the Himawari or the OW SICTDS showed no statistical difference from the average fresh weight or dry weight of lettuce grown in the reference chamber with the HPS lamp. The results of this study suggest that an SICTDS could help reduce the electric power demand in a BLSS.

NASA Discipline Life Support Systems↗