Coil systems for measuring conductivity and velocity of plasma streams.
Plasma stream conductivity and velocity measurement, using systems of primary coil and several secondary coils
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Plasma stream conductivity and velocity measurement, using systems of primary coil and several secondary coils
A search coil is a very sensitive instrument that measures low frequency magnetic field radiation. In order for the search coil to achieve its objectives, an electromagnetic clean environment must be provided. On a spacecraft, there are many potential sources of low frequency magnetic field emitter. Consequently, a very stringent program is needed to control the emission from these sources. This paper describes the details of such a program.
Blends of charged and neutral polymers are of interest due to potential applications in rechargeable batteries. In this study, concentration fluctuations in blends of charged poly[lithium 3-(methacryloyloxy)propylsulfonyl-1-(trifluoromethanesulfonyl)imide] (PLiMTFSI) and neutral poly(ethylene oxide) (PEO) were investigated by small-angle neutron scattering (SANS). The scattering data were analyzed in the framework of the random phase approximation (RPA). Since ion dissociation can lead to stiffening, the charged polymers were approximated as rods, while the neutral polymers were assumed to be random coils. This approach works reasonably well at low weight fractions of charged polymers. For blends with higher weight fractions of the charged polymer, concentration fluctuations were highly suppressed, resulting in q-independent coherent structure factors that are inconsistent with the rod-coil RPA.
A novel flip-coil measurement system has been developed for the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Laboratory. This paper describes the design, implementation, and commissioning of the new measurement bench, highlighting its key features, including improved mechanical stability, advanced data acquisition, and enhanced reproducibility. The system enables precise characterization of field integrals and multipole components, ensuring the optimal performance of Insertion Devices (IDs) before installation in the NSLS-II storage ring. The flip-coil system incorporates an innovative approach to minimize mechanical and electrical errors, which significantly improves the reproducibility of measurements. In addition, the system features a state-of-the-art data acquisition system that enables real-time monitoring and analysis, further enhancing the efficiency and accuracy of the measurement process. Furthermore, preliminary tests have demonstrated that the new system meets the stringent requirements for magnetic field characterization of advanced insertion devices, making it an essential tool for future ID commissioning and quality assurance at NSLS-II.
Magnets in the accelerator interaction region (IR) present significant challenges because of high field requirements and limited available space. Conical-shaped magnets offer advantages in these environments by allowing closer placement to the interaction point while maintaining clearance from synchrotron radiation. Interestingly, numerical studies have shown that conical canted-cosine-theta (CCT) designs produce a constant field distribution along the axial direction in the IR quadrupoles for the Electron-Ion Collider (EIC) at Brookhaven National Laboratory. However, the field harmonics generated by conical CCT windings are not yet fully understood. This paper presents an analytical approach to describe the magnetic field produced by a conical surface current and proposes a method for designing conical CCT magnets for accelerator applications. First, we begin with a surface current sheet having a general cosine-theta distribution in spherical coordinates and solve the vector potential using the Green’s function. The magnetic fields generated by the conical current sheet are expressed using associated Legendre polynomials. These results are then related to circular field harmonics and integral field harmonics for designing a coil that produces a pure multipole field. Next, a single layer of the conical CCT winding path is produced based on the cosine-theta current distribution. Finally, the magnetic field quality of dipole and quadrupole conical CCT coils with multiple layers is verified using the Biot-Savart law.
As inductive wireless power transfer reaches higher power levels; thermal management becomes essential. To address these concerns, past works have demonstrated the benefit of encapsulating coil assemblies with thermally conductive materials and integrating backside liquid cooling into coil assemblies. This work adds to these developments by considering the thermal analysis and construction of a liquid-cooled high power polyphase wireless power transfer ground assembly intended for long duration operation at high power levels, aiming towards hundreds of kW or even 1 MW.
Guide collar fastened to a mandrel helps form a coil of strip sheet metal stock. The collar maintains the strip stock in its proper position during winding of each turn of the coil.
Bench model jig and fixture used for hand fabricating spiral coils of various lengths from flat strip stock. This tool is used to make springs and coils to custom lengths.
Suppression of relay coil voltage transients by bifilar winding of relay coil
Magnetic field rapidly reversed in shorted superconducting coil by subjecting coil to increasing external reverse field
This paper presents some of the technical aspects in the development at the Langley Research Center of an air-cove, dual-wound, single-coil, magnetic-suspension system with one-dimensional control. Overall electrical system design features and techniques are discussed in addition to the problems of control and stability. Special treatment is given to the operation of a dual-wound, high-current support coil which provides the bias fields and superimposed modulated field. Other designs features include a six-phase, solid-state power stage for modulation of the relatively large magnitude control current, and an associated six-phase trigger circuit.
Mathematical modeling is used to determine the effects of resistance and capacitance upon the audio-inductance range of beryllium hammer coils and beryllium nylon-potted coils.
Report examines relationship between coil loss and frequency and heat loss in coil as a function of the magnetic field H. Information is of value to manufacturers of superconducting magnets, motors and generators.
A retrospective summary is presented of the performance of the two-coil superconducting pilot rig which preceded the NASA Lewis bumpy torus. The NASA Lewis bumpy torus facility consists of 12 superconducting coils, each with a 19 cm i.d. and capable of producing magnetic field strengths of 3.0 teslas on their axes. The magnets are equally spaced around a major circumference 1.52 m in diameter, and are mounted with the major axis of the torus vertical in a single vacuum tank 2.59 m in diameter. The design value of maximum magnetic field on the magnetic axis (3.0 T) has been reached and exceeded.
An empirical relation is presented which allows simple computation of volume-averaged winding fields from central fields for coils of small rectangular cross sections. This relation suggests that, in certain applications, ac-loss minimization can be accomplished by use of low winding densities, provided that hysteresis losses are independent of winding density. The ac-loss measurements on coils wound of twisted multifilamentary composite superconductors show no significant dependence on ac losses on winding density, thus permitting the use of winding density as an independent design parameter in loss minimization.
New replaceable carbon insert for deflection coil in electron-beam welder promises to decrease maintenance costs. Inserts made from materials other than carbon (not yet tried) are less expensive, thus reducing costs even further. With carbon insert, deflection coils last longer and are easier to maintain.
Flat coil has rigid printed circuit substrate. New coil structure minimizes RF electric field near glass walls of plasma vessel; therefore reduces direct electron bombardment of glass. Design lends itself well to high production and standardized dimensions.
The coil planet centrifuge uses a centrifugal force field to provide separation of particles based on differences in sedimentation rates by flow through a rotating coiled tube. Three main separations are considered: (1) single phase fresh sheep and human erythrocytes, (2) single phase fixed heep and human erythrocytes, and (3) electrophoretically enhanced single phase fresh sheep and human erythrocytes.