Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cold pools”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Effects of Horizontal Resolution, Domain Size, Boundary Conditions, and Surface Heterogeneity on Coarse LES of a Convective Boundary Layer

Atmospheric properties in a convective boundary layer vary over a wide range of spatial scales and are commonly studied using large-eddy simulations (LES) in various configurations. We examine how the boundary layer depth and distribution of variability across scales are affected by LES grid spacing, domain size, inhomogeneity of surface properties, and external forcing. Two different setups of the Weather Research and Forecasting (WRF) model are analyzed. A semi-idealized configuration uses a periodic domain, flat surface, prescribed homogeneous surface heat fluxes, and horizontally uniform profiles of large-scale advective tendencies. A nested LES setup employs a larger domain and realistic initial and boundary conditions, including an interactive land surface model with representative topography and vegetation and soil types. Subdomains of identical size are analyzed for all simulations. Characteristic structure sizes are quantified using the variability scales L 50 and L 95 , defined such that features smaller than that contain 50% and 95% of the total variance, respectively. Progressive increase in L 50 from vertical velocity to temperature and moisture structures is systematically reproduced in all simulation configurations. This dependence of L 50 on the considered variable complicates the development of scale-aware parameterizations for models with grid spacing in the “terra incognita”. In simulations using a larger domain with heterogeneous surface properties, the development of internal mesoscale patterns significantly affects variance distributions inside analyzed subdomains. Sizes of boundary layer structures also strongly depend on the LES grid spacing and, in case of heterogeneous surface and topography, on location of the subdomain inside a larger computational domain.

54 ENVIRONMENTAL SCIENCES↗

On possible interactions between upper and lower atmosphere

Comparison of geomagnetic data with data on tropospheric and stratospheric circulation characteristics shows a statistically highly significant shrinking in areal extent of the stratospheric vortex from the third to the eight day following a geomagnetic storm. During the contraction of the polar vortex edge, the mean height of the vortex central contour decreases only slightly. This indicates that a stratospheric warming event is associated with a steepening of the contour gradient rather than a warming over the entire area of the stratospheric polar vortex. The troposphere reacts to these weak, but nevertheless significant stratospheric warming events by a shrinkage of the area of the 500-mb cold air pool. It is shown that the observed warming of the stratosphere that follows a geomagnetically disturbed key day cannot be explained by simple radiation absorption.

Macdonald, B. C.↗

On possible interactions between upper and lower atmosphere

Geomagnetic data was compared with data on tropospheric and stratospheric circulation characteristics; a statistically significant shrinking was found in areal extent of the stratospheric vortex from the third to the eighth day following a 'geomagnetic storm' The meridionality of the 30 640-m contour line at 10 millibars increases markedly from 5 to 8 days after the storm. During the contraction of the polar vortex edge, the mean height of the vortex central contour decreases only slightly. This indicates that a stratospheric warming event is associated with a steepening of the contour gradient rather than a warming over the entire area of the stratospheric polar vortex. The troposphere reacts to these weak, but significant, stratospheric warming events by a shrinkage of the area of the 500-millibar cold air pool. This shrinkage commences about 3 days after the stratospheric warming. The investigation indicates that the energy input into the stratosphere that is received in conjunction with the geomagnetic disturbance has to come at a propitious time, when the stratospheric-tropospheric circulation system is not already undergoing a major readjustment because of an inherent dynamic instability.

Macdonald, B. C.↗

Panel Discussion: Life in the Cosmos

Water appears to be essential to all life on Earth. For this reason, "Follow the Water" has been adopted as a mantra for the search for Life in the Cosmos. Expeditions have helped to establish the limits and biodiversity of life in the most extreme environments on Earth. Microbial extremophiles inhabit acidic streams; hypersaline and hyperalkaline lakes and pools; the cold deep sea floor, permafrost, rocks, glaciers, and perennially ice-covered lakes of the polar environments; geysers, volcanic fumaroles, hydrothermal vents and hot rocks deep within the Earth's crust. The ESA Venus Express Spacecraft entered Venusian Orbit in 2006 and continues to produce exciting results. The Visible and Infrared Thermal Imaging Spectrometer (VIRTIS) instrument made the first detection of hydroxyl in the atmosphere of Venus, indicating it is much more similar to Earth and Mars than previously thought. Huge hurricane-like vortices have been found above the poles of the planet and as yet unidentified UV absorbers that form mysterious dark bands in the upper atmosphere. At 70 km and below, water vapor and sulfur dioxide combine to form sulfuric acid droplets that create a haze above the cloud tops. Thermophilic acidophiles, such as have recently been discovered on Earth, could possibly survive in the hot sulfuric acid droplets that exist in the upper atmosphere of Venus. In order to understand how to search for life elsewhere in the Solar System, over 40 VIRTIS images of Earth from Venus have been obtained to search for evidence of life on Earth. The signatures of water and molecular Oxygen were detected in the Earth s atmosphere, but the atmosphere of Venus also exhibits these signatures. The water and water ice are far more abundant on comet, the polar caps and permafrost of Mars and the icy moons of Jupiter and Saturn. These "frozen worlds" of our Solar System, are much more promising regimes where extant or extinct microbial life may exist. The ESA Mars Advanced Radar for Subsurface and Ionospheric Sounding (MARSIS) probe has found that both the North and South Polar Caps of Mars are approximately 3.5 km thick and are composed almost entirely of water ice. In winter, a thin dry ice layer covers the caps, but it sublimates directly to CO2 in the spring. The ESA Mars Express Orbiter images reveal Rupes Tenuis to be a vast snow-laden region on the southern edge of the Martian North Polar Cap. The Mars Exploration Rover Spirit found alkaline volcanic rocks in the Gusev Crater and the Phoenix Mars Lander has shown that the soil of Mars is much more alkaline than previously expected. The Phoenix Mars Lander has also made direct observations of frozen and liquid water on Mars. It is known that microorganisms from Alaska, Siberia and Antarctica can remain alive frozen in permafrost or ice for long periods of time. These discoveries increase the possibility that the Labeled Release Experiment may have discovered life on Mars during the Viking Mission and provide strong impetus for the return of life detection experiments to Mars. Changes in the spin rate of Saturn's moon Titan indicate that it may also harbor a 300 km thick liquid water ocean beneath its icy crust. The NASA/ESA/Italian Space Agency Cassini Spacecraft has imaged geysers containing water vapor, methane, carbon dioxide and organics erupting from the "tiger stripe" regions near the South Pole of Saturn's moon Enceladus. The high temperatures observed, the water vapor and large number of ice particles expelled suggest that a liquid water lake may exist beneath the "tiger stripe" ice cracks of Enceladus. The NASA Deep Impact probe found the surface temperature of comet 9P/Temple 1 at 1.5 AY was slightly above the ice/water phase change temperature (273 K). This suggests melting of water ice near the comet surface. A spectrometer the spacecraft detected a mixture of clay and carbonate minerals (that form in the presence of liquid water) streaming off the comet after the collision with the pactor. The study of chemical and mineral biomarkers, chiral amino acids and possible indigenous microfossils in SNC and carbonaceous meteorites continues. These results suggest that comets should be considered prime targets in the search for Life in the Cosmos. The ESA Rosetta mission is on track to rendezvous with comet 67P/Churyumov-Gerasimenko. The recent space observations combined with new information about the ability of microbial extremophiles to thrive in polar environments suggest that life may be far more widely distributed in the Cosmos than previously thought possible. The Panelists will review recent discoveries and provide their own insights about Life in the Cosmos -- followed by a question and answer session with the audience.

Hoover, Richard B.↗

Comparison of the Sensitivity of Surface Downward Longwave Radiation to Changes in Water Vapor at Two High Elevation Sites

Among the potential reasons for enhanced warming rates in many high elevation regions is the nonlinear relationship between surface downward longwave radiation (DLR) and specific humidity (q). In this study we use ground-based observations at two neighboring high elevation sites in Southwestern Colorado that have different local topography and are 1.3 kilometers apart horizontally and 348 meters vertically. We examine the spatial consistency of the sensitivities (partial derivatives) of DLR with respect to changes in q, and the sensitivities are obtained from the Jacobian matrix of a neural network analysis. Although the relationship between DLR and q is the same at both sites, the sensitivities are higher when q is smaller, which occurs more frequently at the higher elevation site. There is a distinct hourly distribution in the sensitivities at both sites especially for high sensitivity cases, although the range is greater at the lower elevation site. The hourly distribution of the sensitivities relates to that of q. Under clear skies during daytime, q is similar between the two sites, however under cloudy skies or at night, it is not. This means that the DLR-q sensitivities are similar at the two sites during daytime but not at night, and care must be exercised when using data from one site to infer the impact of water vapor feedbacks at another site, particularly at night. Our analysis suggests that care should be exercised when using the lapse rate adjustment to infill high frequency data in a complex topographical region, particularly when one of the stations is subject to cold air pooling as found here.

elevation↗

Advanced Computational Modeling of High-Level Waste Vitrification at the Hanford Site

The U.S. Department of Energy (DOE) has selected vitrification for stabilizing legacy tank waste at the Hanford site, where radioactive waste from plutonium production was historically stored in underground tanks. This waste will be separated into low-activity waste (LAW) and high-level waste (HLW) fractions and processed at the Waste Treatment and Immobilization Plant (WTP). At WTP, glass melters are used for the vitrification of radioactive tank waste, transforming it into a stable borosilicate glass form for safe long-term storage. The melter vessel is constructed from highly durable and heat-resistant materials, where the vitrification process occurs. The main regions that are modeled are the melt pool, plenum, cold cap, riser/discharge chamber, and surrounding structure with insulation layers. Forced convection induced by air bubblers at the base of the melter ensure uniform temperature distribution and provide heat to the cold cap layer. The cold cap is a region of reacting batch feed that floats on top of the molten glass and is where the batch-to-glass reactions occur. Joule heating provided by electrodes mounted along the vertical walls of the melter and immersed directly in the glass, generates the necessary heat for the net endothermic conversion processes that occur in the cold cap. The high temperatures, radioactivity, and opaque nature of the glass prevent direct observation inside the melters. Therefore, computational models are essential for providing insight into factors that affect melter throughput. Thermocouples in the plenum provide operators with plenum temperature measurements. Operational adjustments include bubbling rate, voltage supplied to the electrodes, feed adjustments, and glass removal rate. Different computational fluid dynamics (CFD) models have been developed, each serving a specific purpose. There are CFD models of different scale melters, as well as models that capture the two-phase flow interfaces of rising bubbles in the molten glass or models with a simplified molten glass region so that the surrounding structure and plenum can be feasibly incorporated. Pilot-scale melter models have been developed to serve as validation of the methods employed in the simulation of the full-scale WTP melters. Models incorporating resolved bubbling are used to develop momentum source terms to implement into a single phase, multi-region, steady-state flow model that is being validated by measured process parameters such as glass production rate, voltage, input power, plenum temperatures, etc. The resolved bubbling model uses the multiphase volume of fluid approach to model the system with a high-resolution interface capturing scheme to maintain sharp interfaces between the molten glass and the air phase. The suite of CFD models is continually being improved to incorporate more realistic physics and achieve faster turnaround time. For example, an incremental controller is implemented to automatically adjust electrode voltage within the simulation to a molten glass set point temperature of 1150°C. Newer models feature improved meshes to ensure conformal meshes between regions and eliminate unnecessary mesh refinement in areas that are not of interest (such as boundary layers in offgas ports). Instead of explicitly modeling the structural, refractory, and insulation layers of the melter, a thermal resistance approach is used with published correlations used for boundary conditions. The development of robust and efficient CFD models will be instrumental in enabling the WTP to successfully fulfill its mission of safely stabilizing legacy nuclear waste.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Hydrogen wide area monitoring of LH2 releases

The characterization of liquid hydrogen (LH2) releases has been identified as an international research priority to expand the safe use of hydrogen as an energy carrier. The elucidation of LH2 release behavior will require the development of dispersion and other models, guided and validated by empirical field measurements such as those afforded by Hydrogen Wide Area Monitoring (HyWAM). HyWAM can be defined as the quantitative spatial and temporal three-dimensional monitoring of planned or unintentional hydrogen releases. With support provided through the FCH JU Prenormative Research for the Safe Use of Liquid Hydrogen (PRESLHY) program, HSE performed a series of LH2 releases to characterize the dispersion and pooling behavior of cold hydrogen releases. The NREL Sensor Laboratory developed a HyWAM system based upon a distributed array of point sensors that is amenable for profiling cold hydrogen plumes. The NREL Sensor Laboratory and HSE formally committed to collaborate on profiling the LH2 releases. This collaboration included the integration of the NREL HyWAM into the HSE LH2 release hardware. This was achieved through a deployment plan jointly developed by the NREL and HSE personnel. Under this plan, the NREL Sensor Laboratory provided multiple HyWAM modules that accommodated 32 sampling points for near-field hydrogen profiling during the HSE PRESLHY LH2 releases. The NREL HyWAM would be utilized throughout the LH2 release study performed under PRESLHY by HSE, including Work Package 3 (WP3—Release and Mixing--Rainout) and subsequent work packages (WP4—Ignition and WP5—Combustion). Under the auspices of the PRESLHY WP6 (Implementation), data and findings from the HSE LH2 Releases are to be made available to stakeholders in the hydrogen community. Comprehensive data analysis and dissemination is ongoing, but the integration of the NREL HyWAM into the HSE LH2 Release Apparatus and its performance as well as some key outcomes of the LH2 releases in WP3 are presented.

08 HYDROGEN↗

Computationally Aided Design of a Small-Scale Waste-Glass Melter - 20452

To provide mission support to the WTP for the vitrification of legacy nuclear tank waste at the Hanford site, a reduced-scale vitrification pilot system is being designed to process simulated and actual radioactive tank wastes. The waste stored in underground tanks will be separated into HLW and LAW fractions, where the majority is LAW by mass (approximately 90%) and HLW by activity (greater than 95%). The first tank waste to be processed at the WTP will be LAW. Because Hanford tank waste and the resultant melter feed compositions are known to vary widely, pilot-scale operations are essential to identify potential problems, provide needed data, confirm assumptions, and determine impacts to full-scale melters and off-gas systems from these different feeds. In addition, the reduced-scale melter system must be capable of quickly providing results to operations without the typically high cost of full-scale radioactive operations and to provide an engineering platform in close proximity to local operations staff. The objectives of this computational modeling effort are to produce process conditions like those encountered in the WTP LAW melters and to minimize the volume of radioactive waste necessary for the evaluations. To this end, melter design features are being explored to increase production without significantly increasing surface area or melter-glass volumes or compromising data quality. In support of these objectives, a set of computational fluid dynamic models was developed to provide insight into the flow patterns within these small melters and evaluate design features to increase production without significantly increasing glass inventory. Computed velocities were evaluated at the interface between the cold cap and the molten-glass pool and within the bulk-glass pool. Since melt rate correlates with the velocity underneath the cold cap, this information can be used to select design features that produce the highest gains. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of cold-cap-bottom shear stress on primary foam stability

Here, we analyze the heat transfer between the melt pool and the layer of reacting materials called cold cap, which is the determining factor for the glass production rate in Joule-heated air-bubbled nuclear waste glass melters. We consider the effects of bubbling rate, melt viscosity, melt thermal conductivity, conversion kinetics, and shear rate at the cold-cap bottom, and develop simple relationships for the cold-cap bottom temperature and glass production rate. We show that the melt convection enhances the heat transfer to the cold cap by suppressing the thermal boundary layer and primary foam, while the conversion kinetics opposes these effects. Additionally, we mention how dissolving silica particles affects the primary foam stability and discuss the limitations of the presented approach for vigorously foaming feeds.

36 MATERIALS SCIENCE↗

Glass production rate in an electric melter: Melting rate correlation and primary foam stability

Waste loading and melting rate are major factors determining the lifecycle of nuclear waste disposal by vitrification in electric melters in which the heat to the cold cap is delivered from the melt pool. One of the crucial parameters that affect the rate of melting is the temperature at which the primary foam collapses at the cold cap bottom. Further, apart from the transient glass-forming melt viscosity, primary foam stability is affected by the shear stress imposed by the flow in the melt pool and the presence of residual solid particles.

36 MATERIALS SCIENCE↗

Tropical Convection and Climate Processes in a Cumulus Ensemble Model

Local convective-radiative equilibrium states of the tropical atmosphere are determined by the following external forcing: 1) Insolation, 2) Surface heat and moisture exchanges (primarily radiation and evaporation), 3) Heating and moistening induced by large-scale circulation. Understanding the equilibrium states of the tropical atmosphere in different external forcing conditions is of vital importance for studying cumulus parameterization, climate feedbacks, and climate changes. We extend our previous study using the Goddard Cumulus Ensemble (GCE) Model which resolves convective-radiative processes more explicitly than global climate models do. Several experiments are carried out under fixed insolation and sea surface temperature. The prescribed SST consists of a uniform warm pool (29C) surrounded by uniform cold SST (26C). The model produces "Walker"-type circulation with the ascending branch of the model atmosphere more humid than the descending part, but the vertically integrated temperature does not show a horizontal gradient. The results are compared with satellite measured moisture by SSM/I (Special Sensor Microwave/Imager) and temperature by MSU in the ascending and descending tropical atmosphere. The vertically integrated temperature and humidity in the two model regimes are comparable to the observed values in the tropics.

Sui, Chung-Hsiung↗

Compositional Variation Tests on DuraMelter 100 with LAW Sub-Envelope A1 Feed (LAWA44 Glass) in Support of the LAW Pilot Melter, VSL-02R62N0-4, Rev. 0 (Nov 2002)

The two tests described in this report utilized blended feed (glass formers plus waste simulant) prepared by Optima Chemicals according to VSL specifications generating about 1. 7 metric tons of glass. Sugar was added (at VSL) to the nominal feed at a "sugar ratio" of 0.5 for each of the two variation tests1; however, since the sugar addition is assumed to be "blind" to the variations, the actual sugar ratios were 0.57 and 0.44. The DMl00-WV melter was used in order to provide a direct comparison with the LAW tests previously conducted on the same melter. Two 100-hour melter tests were conducted: one with a 15% deficiency in simulant and one with 15% excess in simulant. Key operating parameters including cold cap coverage, feed rate, and glass pool temperature were held constant to investigate the effects of the glass compositional changes on processing characteristics (including salt formation) and the product glass. The bubbling rate was adjusted to provide the desired glass production rate with a near complete cold cap (90-100% of melt surface covered with feed). Quantitative measurements of glass production rates, melter operating conditions (temperatures, pressures, power, flows, etc.), and off-gas characteristics (NOx, SO 2, CO, particulate load and composition, and acid gases) were made for each test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computationally-Aided Design of a Small-Scale Radioactive Waste Glass Melter

To provide mission support to the Hanford Waste Immobilization and Treatment Plant for the vitrification of legacy nuclear tank waste, a reduced-scale vitrification pilot system is being designed to process simulated and actual radioactive tank wastes. The tank waste will be separated into high-level waste (HLW) and low-activity waste (LAW) fractions, where the majority by mass (~90%) is LAW and by activity (>95%) is HLW. The first tank waste to be processed at the WTP will be LAW. Since Hanford tank waste and the resultant melter feed compositions are known to vary widely, pilot-scale operations are essential to identify potential problems, provide needed data, confirm assumptions, and determine impacts to full-scale melters and off-gas systems from these different feeds. In addition, the reduced-scale melter system must be capable of quickly providing results to operations without the typically high costs of radioactive operations and provide an engineering platform in close proximity to local operations staff. The objective is to produce similar process conditions to those encountered in the full-scale LAW melters and minimize the volume of radioactive waste necessary for the evaluations. To this end, melter design features are being explored to increase production without significantly increasing surface area, melter glass volumes or compromising data quality. In support of these objectives, a set of computational fluid dynamic models have been developed to provide insight into the flow patterns within these small melters and evaluate design features to increase production without significantly increasing glass inventory. Computed velocities were evaluated at the interface between the cold cap and the molten glass pool and within the bulk glass pool. A method was developed to correlate results to an estimated melt rate and down-select design features that produce the highest gains.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computationally-Aided Design of a Small-Scale Radioactive Waste Glass Melter

To provide mission support to the Hanford Waste Immobilization and Treatment Plant for the vitrification of legacy nuclear tank waste, a reduced-scale vitrification pilot system is being designed to process simulated and actual radioactive tank wastes. The tank waste will be separated into high-level waste (HLW) and low-activity waste (LAW) fractions, where the majority by mass (~90%) is LAW and by activity (>95%) is HLW. The first tank waste to be processed at the WTP will be LAW. Since Hanford tank waste and the resultant melter feed compositions are known to vary widely, pilot-scale operations are essential to identify potential problems, provide needed data, confirm assumptions, and determine impacts to full-scale melters and off-gas systems from these different feeds. In addition, the reduced-scale melter system must be capable of quickly providing results to operations without the typically high costs of radioactive operations and provide an engineering platform in close proximity to local operations staff. The objective is to produce similar process conditions to those encountered in the full-scale LAW melters and minimize the volume of radioactive waste necessary for the evaluations. To this end, melter design features are being explored to increase production without significantly increasing surface area, melter glass volumes or compromising data quality. In support of these objectives, a set of computational fluid dynamic models have been developed to provide insight into the flow patterns within these small melters and evaluate design features to increase production without significantly increasing glass inventory. Computed velocities were evaluated at the interface between the cold cap and the molten glass pool and within the bulk glass pool. A method was developed to correlate results to an estimated melt rate and down-select design features that produce the highest gains.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Laboratory Study of the Effect of Frost Flowers on C Band Radar Backscatter from Sea Ice

C band images of Arctic sea ice taken by the ERS 1 synthetic aperture radar show transitory regions of enhanced radar backscatter from young sea ice. Published field observations associate this increase with frost flower growth and the capture of blowing snow by the flowers. To investigate the first part of this phenomenon, we carried out a laboratory experiment on the response of C band radar backscatter to frost flowers growing on the surface of newly formed saline ice. The experiment took place in a 5 m by 7 m by 1.2 m deep saline water pool located in a two-story indoor refrigerated facility at the Cold Regions Research and Engineering Laboratory. Sodium chloride ice was grown in this pool at an air temperature of -28 C. The frost flowers first appeared on the ice surface as dendrites and then changed to needles as the ice sheet grew thicker and the surface temperatures became colder. The frost flowers reached to a height of 10-15 mm, and beneath each cluster of frost flowers a slush layer formed to a thickness of approximately 4 mm. Far-field radar measurements of the backscatter from the ice were made at incident angles from 20 to 40 deg and at approximately 6-hour intervals throughout the 3-day period of the experiment. A backscatter minimum occurred early in the flower growth at the time coincident with an abrupt doubling in the ice surface salinity. Once the full flower coverage was achieved, we removed first the crystal flowers and then the slush layer from the ice surface. The results for these cases show that the crystals have little impact on the backscatter, while the underlying slush patches yield a backscatter increase of 3-5 dB over that of bare ice. The laboratory results suggest that this relative backscatter increase of approximately 5 dB can be used as an index to mark the full area coverage of frost flowers.

Nghiem, S. V.↗

A Laboratory Study of the Effect of Frost Flowers on C Band Radar Backscatter from Sea Ice

C band images of Arctic sea ice taken by the ERS 1 synthetic aperture radar show transitory regions of enhanced radar backscatter from young sea ice. Published field observations associate this increase with frost flower growth and the capture of blowing snow by the flowers. To investigate the first part of this phenomenon, we carried out a laboratory experiment on the response of C band radar backscatter to frost flowers growing on the surface of newly formed saline ice. The experiment took place in a 5 m by 7 m by 1.2 m deep saline water pool located in a two-story indoor refrigerated facility at the Cold Regions Research and Engineering Laboratory. Sodium chloride ice was grown in this pool at an air temperature of -28 C. The frost flowers first appeared on the ice surface as dendrites and then changed to needles as the ice sheet grew thicker and the surface temperatures became colder. The frost flowers reached to a height of 10-15 mm, and beneath each cluster of frost flowers a slush layer formed to a thickness of approximately 4 mm. Far-field radar measurements of the backscatter from the ice were made at incident angles from 20 C to 40 C and at approximately 6-hour intervals throughout the 3-day period of the experiment. A backscatter minimum occurred early in the flower growth at the time coincident with an abrupt doubling in the ice surface salinity. Once the full flower coverage was achieved, we removed first the crystal flowers and then the slush layer from the ice surface. The results for these cases show that the crystals have little impact on the backscatter, while the underlying slush patches yield a backscatter increase of 3-5 dB over that o f bare ice. The laboratory results suggest that this relative backscatter increase of approximately 5 dB can be used as an index to mark the full areal coverage of frost flowers.

Nghiem, S. V.↗

The Role of Bjerknes and Shortwave Feedbacks in the Tropical Pacific SST Response to Global Warming

Abstract The evolution of tropical sea surface temperatures (SSTs) in response to greenhouse warming is of great societal and scientific interest. Most state‐of‐the‐art climate models predict a mean “El Niño‐like” warming pattern by century‐end, characterized by greater warming over the Pacific cold tongue compared to the western warm pool. However, it is unclear which proposed mechanism dominates in this response. Here, we present partially coupled abrupt CO 2 doubling experiments in which surface wind stress and shortwave heating are overridden to values from a control simulation. Contrary to previous studies, we find that experiments with overriding of surface wind stress exhibit only 58% of the full reduction in east‐west SST contrast. When both surface wind stress and shortwave flux are overridden, only 34% of the full reduction remains, controlled by spatially‐varying evaporative cooling. These results underscore the importance of Bjerknes and shortwave feedbacks in the tropical Pacific SST response to global warming.

Geology↗

Alkali metal pool boiler life tests for a 25 kWe advanced Stirling conversion system

The overall operating temperature and efficiency of solar-powered Stirling engines can be improved by adding an alkali metal pool boiler heat transport system to supply heat more uniformly to the heater head tubes. One issue with liquid metal pool boilers is unstable boiling. Stable boiling is obtained with an enhanced boiling surface containing nucleation sites that promote continuous boiling. Over longer time periods, it is possible that the boiling behavior of the system will change. An 800-h life test was conducted to verify that pool boiling with the chosen fluid/surface combination remains stable as the system ages. The apparatus uses NaK boiling on a - 100 + 140 stainless steel sintered porous layer, with the addition of a small amount of xenon. Pool boiling remained stable to the end of life test. The pool boiler life test included a total of 82 cold starts, to simulate startup each morning, and 60 warm restarts, to simulate cloud cover transients. The behavior of the cold and warm starts showed no significant changes during the life test. In the experiments, the fluid/surface combination provided stable, high-performance boiling at the operating temperature of 700 C. Based on these experiments, a pool boiler was designed for a full-scale 25-kWe Stirling system.

Anderson, W. G.↗