Search NASA⌕ Search

SEARCH · Search NASA

Results for “Commercial Off The Shelf”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Fault Response of Distributed Energy Resources Considering the Requirements of IEEE 1547-2018

Inverter-based DER responses to faults on the electric power system are different than those of conventional generators and are often poorly understood. Inverter fault responses are largely software-defined, within physics-based constraints. DERs are regulated by standards and grid codes that also constrain their responses. Though fault response of DERs will vary widely, for any DER following any particular standard, a pattern of fault response can be synthesized by observing that particular standard. In this paper, the recently published IEEE 1547-2018 is examined to explore the general fault response of any DER that follows IEEE 1547-2018. Additionally, an IEEE 1547-2018 compliant inverter model is developed and tested in simulation to find the fault response, and that response is compared with the fault response of a commercial off-the-shelf inverter.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Intelligent Consequence Control by Aerial Reconnoiter Using Unmanned Systems

In a nuclear accident, or in the aftermath of an improvised nuclear device or radiological dispersal device detonation, radioactive materials may pose a severe health threat to individuals near the site of the incident. The Intelligent Consequence Control by Aerial Reconnoiter Using Unmanned Systems (ICARUS) does the dull, dirty, and dangerous (and, sometimes, deep) work of mapping and characterizing valuable information to enable a safe and appropriate response. ICARUS provides timely answers to the questions, “What is it?” “Where is it?”, and “How far does it extend?” Using commercial, off-the-shelf proven components, the integrated chemical, biological, radiological, nuclear, and explosives detection architecture for our drones provides a solution for collecting radiological, chemical, and optical information on developing complex situations, returning actionable data for determining if it is safe for further response efforts. ICARUS can determine and transmit the location, identity, and intensity of radionuclide contamination to a remote base station. It can deliver on the unexpected.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spallation Neutron Source Proton Power Upgrade Low-Level RF Control System Development

The Proton Power Upgrade (PPU) Project is approved for the Spallation Neutron Source at Oak Ridge National Laboratory and will double the proton beam power capability from 1.4 MW to 2.8 MW with 2 MW beam power available to the first target station. A second target station is planned and will utilize the remaining beam power in the future. The proton power increase will be supported with the addition of twenty-eight new superconducting cavities powered by 700 kW peak power klystrons to increase beam energy while increases to the beam current will be done with a combination of existing RF margin, and DTL HPRF upgrades. The original low-level RF control system has proven to be reliable over the past 15 years of operations, but obsolescence issues mandate a replacement system be developed for the PPU project. The replacement system is realized in a µTCA.4 platform using a combination of commercial off-the-shelf boards and custom hardware to support the requirements of PPU. This paper presents the prototype hardware, firmware, and software development activities along with preliminary testing results of the new system.

Crofford, Mark↗

Architecture Of A Multi-channel Data Streaming Device With An Fpga As A Coprocessor

The design of a data acquisition system often involves the integration of a Field Programmable Gate Array (FPGA) with analog front-end components to achieve precise timing and control. Reuse of these hardware systems can be difficult since they need to be tightly coupled to the communications interface and timing requirements of the specific ADC used. A hybrid design exploring the use of FPGA as a coprocessor to a traditional CPU in a dataflow architecture is presented. Reduction in the volume of data and gradual transitioning of data processing away from a hard real-time environment are both discussed. Chief design concerns, including data throughput and precise synchronization with external stimuli, are addressed. The discussion is illustrated by the implementation of a multi-channel digital integrator, a device based entirely on commercial off-the-shelf (COTS) equipment.

Nogiec, Jerzy M.↗

Recommendations for Secure Transport: Material Conveyance Physical Protection Technology

Nuclear material is at higher risk of theft and sabotage during transport than during any other phase of the nuclear fuel lifecycle. Nuclear materials are transported in the public domain where adversaries have an upper hand by taking advantage of the time and location of the theft or sabotage attempt. As such, even modest threat profiles for transport of nuclear and radioactive material can require substantial detection and delay measures to support timely response. Conveyance tracking augmented with technology that improves on-the-scene situational awareness at a remote monitoring center has been adopted as a de-facto standard approach for transportation security. At present, the extended tracking and situational awareness capabilities needed for a nuclear material shipment, as is provided by the purpose designed, Transportation – Security, Tracking and Reporting (T-STAR) System, do not exist in a single commercial off-the-shelf (COTS) solution. Typically, the COTS systems that excel in one area are deficient in other areas, presenting challenges to designing well-rounded, robust systems. Still, COTS solutions can offer the basic set of tracking and situational awareness capabilities by indicating last update time, current location, and route taken. By incorporating vehicle and driver performance measures via the vehicle’s controller area network (CAN bus) and video alongside other data streams allows telemetry and other shipment information to be assessed in novel ways.This paper describes the operation, capabilities and features of various conveyance protection systems and approaches, assesses emerging technologies and how they could be used through a unified interface, and enumerates additional ways to provide early detection using vehicle, onboard technologies, effective delay technologies and approaches and simple equipment to improve protection during transport.

Shannon, Michael↗

Probe for operando in situ electrochemical nuclear magnetic resonance spectroscopy

Electrochemical devices with metal casings have been considered incompatible with nuclear magnetic resonance (NMR) spectroscopy because the oscillating magnetic fields (“rf fields”) responsible for excitation and detection of NMR active nuclei do not penetrate metals. According to the present invention, rf fields can still efficiently penetrate into nonmetallic layers of electrochemical cells (such as a coin cell battery configuration) provided the magnetic field is oriented tangentially to the electrochemical cell electrodes in a “skimming” orientation. As an example, noninvasive high field in situ 7Li and 19F NMR of an unmodified commercial off-the-shelf rechargeable coin cell was demonstrated using a traditional external NMR coil setup. The in operando NMR measurements revealed that irreversible physical changes accumulate at the anode during electrochemical cycling.

Sorte, Eric Glenn↗

Direct analysis of cotton swipes for uranium and plutonium isotopic determination by microextraction-ICP-MS

The determination of uranium and plutonium isotopic abundance on environmental samples collected by International Atomic Energy Agency (IAEA) inspectors is vital for the detection of undeclared nuclear activities and material under the international nuclear safeguards regime. Current analytical protocols require time-consuming sample preparation steps prior to subsequent measurement by inorganic mass spectrometry (MS). Recent efforts from this laboratory have focused on developing sample preparation methods for faster analysis, potentially allowing higher sample throughput[1]. Alternative methods including microextraction sampling in conjunction with inductively coupled plasma-mass spectrometry (ICP-MS) have been recently explored. This methodology, microextraction-ICP-MS, was developed such that uranium and plutonium could be extracted from the swipe surface and directed into the ICP-MS for an in-situ measurement, eliminating the need for swipe ashing and digestion. A commercial off-the-shelf microextraction system was customized with an automated movable XY stage that can be programmed to save sampling locations, allowing for automated rapid sampling of swipe surfaces. Additional efforts have focused on the utilization of collision cell technology to the microextraction ICP-MS method. This would eliminate the need for lengthy column chemistry procedures to purify separated uranium and plutonium fractions before analysis. Here, the extracted U/Pu analyte is measured by reacting the uranium ions with CO2 in the collision cell of an ICP-MS, shifting the uranium to UO+, which will not interfere with the plutonium isotopic determination. The developed method utilizing collision cell – ICP-MS technology has demonstrated the ability to measure plutonium isotope ratios in the presence of high uranium concentration on the transient signal from the microextraction system utilizing certified reference materials from JRC-Geel and the New Brunswick Laboratory Program Office.

Bradley, Veronica↗

Implementing Mixed Reality Tools to Support Mission Delivery at Hanford - 20520

Mission Support Alliance's (MSA) Public Works and Information Systems organizations have been working with Microsoft Corporation to develop and implement mixed reality operational solutions using their HoloLens technology. This collaborative effort is intended to drive innovative solutions and significantly improve MSA's efficiency in performing work at the Hanford Site. HoloLens, a mixed reality tool, is a commercial off-the-shelf technology that combines a head-mounted viewing screen with applications to help people and organizations learn, communicate, and collaborate more effectively through the use of mixed reality. https://microsoft.com/en-us/hololens MSA's initial pilot successfully demonstrated its ability to use mixed reality utilizing HoloLens' advanced features in a variety of ways, illustrating the potential efficiency gains previously stated as goals of this pilot. These achievements include the development of proprietary technology that allows synchronization between a HoloLens device and a mobile device or alternate global positioning system (GPS) device. This synchronization enables the HoloLens device to access real time GPS location data anywhere on the Hanford Site. This real time location data, combined with MSA's improved Hanford Geographical Information System (GIS) data, enables the mixed reality pilot application to identify underground utility systems as well as related utility attributes. This ability will aid utility workers in several areas, including excavation activities, the placement of large cranes, identifying interactions and conflicts with future underground utility placements and, eventually, recognizing and de-conflicting tank waste transfer system valve alignments. The HoloLens mixed reality application is also able to provide full or small scale holographic images of a facility's digital twin. This feature will allow MSA's Water and Sewer Utilities team to train and validate procedures associated with the new water treatment facility virtually, before it is constructed. This reduces the amount of time it takes to complete the training and procedure validation, and accelerates the overall construction schedule. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understanding Line Losses and Transformer Losses in Rural Isolated Distribution Systems: Preprint

Rural, isolated power systems in the mainland U.S. and in states like Alaska and Hawaii are powered by assets like diesel generators. These rural, isolated power systems also cannot operate at the higher band of medium voltage (like 69kV). They are primarily in the 12 to 14 kV range to keep the cost of the distribution investments lower. Because of this mid-band medium voltage range, the line losses and distribution transformers losses consume significant diesel consumption (almost 10 percent of the peak load). This work considers one such power system powering an isolated system and presents key findings online losses, and transformer losses. Understanding and documenting the impacts is critical for these communities operating their power systems and take actions to reduce expensive diesel consumption. In this paper, we will present one such typical grid and model it in electromagnetic transients (EMT) domain. We used the tower structure, under ground cabling installation to develop high fidelity models of lines. We also used high fidelity models of distribution transformers to present the no-load losses and full load loses. We will also present technical solutions available commercially off-the-shelf to reduce these losses and reduce diesel consumption. This work will be a primer for communities to understand the technical challenges and to understand the possible solution available to solve such challenges for rural, isolated power system operators.

blackstart↗

EVs@Scale Lab Consortium High-Power Charging Pillar Deep-Dive Technical Meeting

Managed under the the U.S. Department of Energy (DOE)-funded EVs@Scale Consortium, the High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project aims to create an experimental platform for integration and control approaches in a direct current (DC), distribution-based high-power charging (HPC) system. The eCHIP project addresses the crucial need to design and validate efficient, low-cost, reliable, and interoperable solutions for a DC-coupled charging hub ("DC hub" for short). This report explains the design, development, and implementation process of an experimental platform for the DC hub. DC distribution holds significant potential for enhancing the operation of an HPC station architecture. However, there are challenges in establishing a DC hub, including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and a lack of common system-level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products, as well as novel, in-house designed solutions, to evaluate different use cases at rated power and voltage levels. The developed proof-of-concept charging platform and open-source SEMS allow the development and testing of various controllers and chargers from different vendors. The DC hub platform integrated EVs, an ESS, a PV system, and building load to demonstrate the flexibility of the platform. The open-source SEMS controlled the devices within the hub using a rule-based implementation, realizing available standards.

ADVANCED PROPULSION SYSTEMS↗

Equivalent-Circuit Models of Grid-Forming IBRs for Electromagnetic-Transient Simulations: Preprint

We derive equivalent-circuit models of control- and physical-layer subsystems of grid-forming (GFM) inverter-based resources (IBRs) for electromagnetic-transient (EMT) simulations. Three different primary controllers are considered: droop, virtual synchronous machine (VSM), and dispatchable virtual oscillator control (dVOC). In addition, the models include cascaded voltage- and current-control loops, and LCL output filters. Simulations for a single-inverter setup and for a network of five inverters in a modified IEEE 14-bus topology are presented. The equivalent-circuit models simulated with analog electronic circuit-simulator software (in our case, LTspice) offer the same accuracy with up to 150x lower computational burden compared to block-diagram-based implementations in commercial off-the-shelf EMT software (in our case, MATLAB-Simulink).

circuit-equivalent model↗

Design and Performance Evaluation of a Resistive Control Using a Hydraulic PTO System for the TALOS Wave Energy Converter

This study is focused on developing a numerical model to evaluate the performance of a hydraulic PTO system for the TALOS Wave Energy Converter. The WEC device is described and the architecture of the hydraulic PTO system is presented with detail. The WEC is modeled using WEC-Sim, and the PTO is modeled using the Simscape Fluids library from Simulink. The hydraulic PTO is based on a constant pressure configuration that is suitable for WEC passive control. The hydraulic system is composed by a set of rectifying valves and two hydraulic accumulators that reduce the stiffness of the system and also serve as energy storage devices. One of the advantages of this hydraulic PTO architecture is the possibility of controlling the electric generator to operate around the optimal efficiency operating point. The main components of the hydraulic PTO are off-the-shelf devices that are commercially available, which will facility a future deployment of the designed system. The design variables used for this study are the accumulator size, the maximum pressure in the accumulators, the hydraulic motor maximum displacement, and the shaft speed in the electric generator. The performance of the system is evaluated individually, using sinusoidal inputs that replicates regular wave conditions. In addition to this, the numerical model of the PTO is coupled to a WEC-Sim simulation of the TALOS Wave Energy Converter with six PTOs to generate a wave-to-wire model. The main objective of this work is to present a comprehensive design methodology that could serve as a guideline for future research efforts focused on implementing control algorithms on multi degree of freedom WECs.

hydraulic systems↗

Experimental Validation of a 40kW, 480V Point-to-Point DC Interlinks for Controller-Agnostic, Interoperable Networked Microgrids

This paper presents the experimental validation of point-to-point dc-interlinks for interconnecting two solar-based, laboratory-scale AC microgrids. DC interlinks provide a solution to numerous technical and operational challenges encountered in networked microgrids, including precise power flow control, stable and fast synchronization, enhanced stability, and improved voltage and frequency regulation. By decoupling microgrids through power converters, dc-interlinks enable power exchange among microgrids that can be owned by different entities (such as communities, utilities, or universities) and managed by diverse microgrid controller vendors. This characteristic makes this dc-interlinks a promising solution for networking real-world microgrids. The presented point-to-point dc interlink utilizes two four-quadrant converters: a 40kW 3-phase ac/dc regulating the dc-link voltage to 800V, and a 3-phase dc/ac controlling power flow. These converters, connected via a 20-foot dc cable, interconnect two ac microgrids operating at 480V, each featuring energy storage, photovoltaic generation, and load emulation. Experimental validation employs commercially available off-the-shelf (COTS) converters and real-world data from solar-powered microgrids in Adjuntas, Puerto Rico. To the authors’ knowledge, this work provides the first at-scale experimental validation of dc-interlinks for networked ac microgrids using COTS inverters, demonstrating their practicality and effectiveness in addressing real-world operational challenges.

Ferrari Maglia, Max [ORNL]↗

Understanding Impacts of Frequency Calculations on Underfrequency Load Shedding

Power system fundamental frequency-dependent protection decisions and control decisions are increasingly common in the distribution system space. Understanding the algorithms used in frequency measurements is critical to understanding the decisions made by the many intelligent electronic devices in the power system. These decisions are critically important for reliability analysis for interconnected power systems as they bear directly on resource planning to mitigate under-frequency conditions that would result in under-frequency load shedding (UFLS). This work aims to improve the understanding of frequency measurement algorithms, evaluate the intelligent electronic devices that use frequency measurements for decision making, and understand the algorithms' direct impact on frequency related decision making. First, this work presents background information on the use of frequency measurements in protection logic, specifically UFLS. Second, the paper presents a relay hardware evaluation test bed used to detect and protect systems from under-frequency events. Finally, the paper presents the dynamic events used to evaluate commercially available, off-the-shelf relay equipment and the results from the relay evaluation.

COMTRADE↗

Technical Assistance for Characterization Studies of Personal Protection Equipment (PPE) (Final CTAP Report)

Sandia National Laboratories (SNL) conducted an independent assessment of three different certified N95 respirators for the State of New Mexico Department of Homeland Security and Emergency Management. The testing conducted under this effort mimicked traditional NIOSH certification testing methodologies, where possible (NIOSH 2019). This included the use of a commercially available off-the-shelf (COTS) instrument typically used in industry for N95 respirator certification (ATI 2018). The COTS system, an Air Techniques International 100Xs automated filter tester, was used for all the testing reported in this document. It is important to note that SNL is NOT a certification laboratory, and all quantitative results are for informational purposes only. Additional technical information of N95-related efforts conducted by this team may be found in: Omana et al. (2020a), Omana et al. (2020b), Celina et al. (2020)

42 ENGINEERING↗

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Minimal Energy Routing of a Leader and a Wingmate with Periodic Connectivity

We consider a route planning problem in which two unmanned vehicles are required to complete a set of tasks present at distinct locations, referred to as targets, with minimum energy consumption. The mission environment is hazardous, and to ensure a safe operation, the UVs are required to communicate with each other at every target they visit. The problem objective is to determine the allocation of the tasks to the UVs and plan tours for the UVs to visit the targets such that the weighted sum of the distances traveled by the UVs and the distances traveled by the communicating signals between them is minimized. We formulate this problem as an Integer program and show that naively solving the problem using commercially available off-the-shelf solvers is insufficient in determining scalable solutions efficiently. To address this computational challenge, we develop an approximation and a heuristic algorithm, and employ them to compute high-quality solutions to a special case of the problem where equal weights are assigned to the distances traveled by the vehicles and the communicating signals. For this special case, we show that the approximation algorithm has a fixed approximation ratio of 3.75. We also develop lower bounds to the optimal cost of the problem to evaluate the performance of these algorithms on large-scale instances. We demonstrate the performance of these algorithms on 500 randomly generated instances with the number of targets ranging from 6 to 100, and show that the algorithms provide high-quality solutions to the problem swiftly; the average computation time of the algorithmic solutions is within a fraction of a second for instances with at most 100 targets. Finally, we show that the approximation ratio has a variable ratio for the weighted case of the problem. Specifically, if ρ denotes the ratio of the weights assigned to the distances representing the communication and travel costs, the algorithm has an a posteriori ratio of $3 + \frac{3ρ}{4}$ when ρ ≥ 1, and $\frac{3}{ρ}$ + $\frac{3}{4}$ when ρ ≤ 1.

42 ENGINEERING↗

Power HIL Validation of a MW-Scale Grid-Forming Inverter's Stabilization of Otherwise Unstable Cases of the Maui Transmission System

This presentation summarizes MW-scale power hardware-in-the-loop experiments using a 2.2 MW grid-forming inverter connected to a real-time electromagnetic transient simulation of the Maui transmission system. The hardware inverter used is a commercially available "off-the-shelf" inverter from a major manufacturer that is capable of operating in grid-forming mode or grid-following mode. The hardware inverter was connected via power hardware-in-the-loop to a real-time model of the year-2023 Maui power system, which consists of a networked transmission system with diverse generation sources. The results of the simulations indicate that with sufficient synchronous machines online, the system is stable without grid-forming inverters, but that as the amount of synchronous machines is reduced, the system becomes unstable. Changing the hardware inverter (scaled up to represent a 30 MW plant) into grid-forming mode mitigates the instability in various low-inertia cases, including a zero-inertia scenario with 100% of generation from PV and wind. This result broadly agrees with pure simulation results.

battery energy storage system↗