Comparative Assessment of Data-driven Process Models in Health Information Technology

Process mining for conformance analysis consists of comparing a reference process model against a data-driven process model generated via log files from information technology systems. However, in the absence of a complete reference process model, we found no suggested approaches in the literature to address the need for evaluating process conformance among different healthcare facilities to assess standardization of care. Our goal is to find similarities and dissimilarities in data-driven process models among US Veterans Health Administration (VHA) facilities that can be indicative of patient safety issues. Our hypothesis was that the analysis would not produce statistically significant differences in outcome. We present a unique implementation of conformance analysis in process mining that consists of combining process mining, process mapping and statistical metrics. We illustrate our approach by applying it to the analysis of two clinical radiology order process models generated from healthcare data provided by two similar facilities in the VHA. The comparative assessment showed that about 70% of the orders completed successfully and 30% were not completed due to policy and duplications. Our analysis found a good statistical correlation between both facilities, as the Spearman’s correlation coefficient between facilities for the frequency of cases per total hours was 0.87879, for the frequency of cases by state transition was 0.79702 and for the throughput time per state transition was 0.63582. Additional statistical analyses using the Mann-Whitney U test and the root mean square error both produced values that were not significant. The foregoing approach validated our hypothesis by demonstrating a good statistical correlation of data describing the flow of clinical radiology orders absent a credible reference model. Finding good agreement between both facilities was important in confirming that the clinical orders flow in a similar manner, suggesting standardization of care.

97 MATHEMATICS AND COMPUTING↗

Towards a Comparative Assessment of Data-Driven Process Models in Health Information Technology

Process mining for conformance analysis focuses on comparing a reference process model against a data-driven process model that is generated via log files from information technology systems. While this approach is helpful when there is an existing process model in an organization, it leaves the question of what to do in the absence of a complete reference process model unanswered. In this paper, we present a comparative assessment approach that combines process mining, process mapping for dimensionality reduction, and statistical analysis. Our goal is to find similarities and dissimilarities in data-driven process models among U.S. Veterans Health Administration (VHA) facilities to assess process conformance among different healthcare facilities, which can help assess the standardization of care. We illustrate our approach by applying it to two clinical radiology order process models generated by two similar facilities. Our results demonstrate statistical similarities in the standardization of care among those two facilities.

Klasky, Hilda↗

Precision bootstrap for the $\mathcal{N}$ = 1 super-Ising model

In this note we report an improved determination of the scaling dimensions and OPE coefficients of the minimal supersymmetric extension of the 3d Ising model using the conformal bootstrap. We also show how this data can be used as input to the Lorentzian inversion formula, finding good agreement between analytic calculations and numerical extremal spectra once mixing effects are resolved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Implementation of Replica Exchange with Dynamical Scaling for Efficient Large-Scale Simulations

An implementation of the replica exchange with dynamical scaling (REDS) method in the commonly used molecular dynamics program GROMACS is presented. REDS is a replica exchange method that requires fewer replicas than conventional replica exchange while still providing data over a range of temperatures and can be used in either constant volume or constant pressure ensembles. Details for running REDS simulations are given, and an application to the human islet amyloid polypeptide (hIAPP) 11-25 fragment shows that the model efficiently samples conformational space.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental and theoretical studies of the doubly substituted methyl-ethyl Criegee intermediate: Infrared action spectroscopy and unimolecular decay to OH radical products

In this work the infrared (IR) action spectrum of the doubly substituted methyl-ethyl Criegee intermediate (MECI) is observed in the CH stretch overtone region with detection of OH products. The MECI exhibits four conformers, all of which undergo unimolecular decay via a 1,4 H-atom transfer mechanism, followed by the rapid release of OH products. Conformers with different orientations of the carbonyl oxide group with respect to the methyl and ethyl substituents (i.e., anti and syn ) decay via distinct transition state barriers (16.1 kcal mol –1 and 15.4 kcal mol –1 , respectively). The observed IR action spectrum is in good agreement with the predicted anharmonic IR absorption spectrum, but exhibits significant congestion, which is attributed to couplings between spectroscopic bright states and nearby dark states. Energy-dependent OH appearance rates are measured upon IR excitation of the strongest features in the IR action spectrum and are found to be on the order of 10 6 –10 7 s –1 . The experimental rates are in good agreement with computed Rice–Ramsperger–Kassel–Marcus rates for the unimolecular decay of MECI at these energies, which incorporate quantum mechanical tunneling and sophisticated hindered rotor treatments, as well as high-level theoretical calculations of the TS barrier heights, rovibrational properties, and torsional barriers associated with the MECI conformers. Master equation modeling is used to predict thermal rates for the unimolecular decay of anti - and syn -MECI of 473 s –1 and 660 s –1 , respectively. Comparison with other previously studied Criegee intermediate systems provides insights into substituent effects on unimolecular decay under both energy-dependent and thermal conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

How directed evolution reshapes the energy landscape in an enzyme to boost catalysis

Two steps forward—now look back Whether designed computationally or uncovered in activity screening, enzymes repurposed for biocatalysis rarely start at the peak of proficiency. However, directed evolution can in some cases increase catalytic efficiency of a poor enzyme by many orders of magnitude. Otten et al. used a suite of biochemical techniques to investigate the origins of rate enhancement in a previously evolved model enzyme. Two conformational states are present in the initial, computationally designed enzyme, but only one is active. Shifting the population toward the active state is one factor in increasing catalytic efficiency during evolution. Single mutations do not greatly increase activity, but the synergistic combination of just two out of 17 substitutions can provide most of the rate enhancement seen in the final, evolved enzyme. Science , this issue p. 1442

Science & Technology - Other Topics↗

Radiation cooler for 10 micrometer wavelength engineering model receiver model no. 7172, serial no. 201

The design, fabrication, and testing of a radiative cooler are described. This cooler is an engineering model suitable for bench testing in the laboratory as a part of the 10-micrometer wavelength engineering model receiver, and conforms to the standard radiative cooler configuration, except that the inner stage and its support system were redesigned to accommodate the larger, heavier SAT detector. This radiative cooler will cool the detector to cryogenic temperature levels when the receiver is in a space environment or in a suitable thermal vacuum chamber. Equipment specifications are given along with the results of thermal tests, vibration tests, and electrical integrity tests.

Source record↗

Miranda - Color and albedo variations from Voyager photometry

Voyager 0.48-micron images of Miranda covering phase angles of 13-39 deg, together with 0.35-micron 0.41-micron, and 0.56-micron data at 16-deg phase angle, are the bases of the Minnaert parameters from which the present albedo/color maps are derived. Color ratios are found to be essentially constant over all terrain types and albedo ranges on the satellite; spectrally, Miranda is gray. The color data are noted to conform with a model in which varying amounts of materials spectrally resembling the asteroidal F-material are mixed with an icy component.

Hillier, J.↗

Flow measurements in a model of the mildly curved femoral artery of man

The effects of curvature on the flow rate near the wall in the vicinity of the mildly curved femoral artery of man, and on the pressure distributions along the curved segment, were investigated using glass and tygon flow models constructed to conform to the shape of the femoral angiogram of a human subject. The test fluid was 33 percent aqueous sucrose. Steady flow observations, made using a dye flow visualization system, revealed a flow pattern like that observed in coiled pipes. A double helical type flow was found to develop, with converging streamlines in the wall vicinity from the upper and lower plane of curvature merging asymptotically along the inner curvature in a stable manner. Pressure measurements for steady flow revealed progressively larger pressure drops with distance along the entrance region of the curved segment, relative to that for a straight lumen.

Back, L. H.↗

Crustal Structure of the Iceland Region from Spectrally Correlated Free-air and Terrain Gravity Data

Seismic refraction studies have provided critical, but spatially restricted constraints on the structure of the Icelandic crust. To obtain a more comprehensive regional view of this tectonically complicated area, we spectrally correlated free-air gravity anomalies against computed gravity effects of the terrain for a crustal thickness model that also conforms to regional seismic and thermal constraints. Our regional crustal thickness estimates suggest thickened crust extends up to 500 km on either side of the Greenland-Scotland Ridge with the Iceland-Faeroe Ridge crust being less extended and on average 3-5 km thinner than the crust of the Greenland-Iceland Ridge. Crustal thickness estimates for Iceland range from 25-35 km in conformity with seismic predictions of a cooler, thicker crust. However, the deepening of our gravity-inferred Moho relative to seismic estimates at the thermal plume and rift zones of Iceland suggests partial melting. The amount of partial melting may range from about 8% beneath the rift zones to perhaps 20% above the plume core where mantle temperatures may be 200-400 C above normal. Beneath Iceland, areally limited regions of partial melting may also be compositionally and mechanically layered

Leftwich, T. E.↗

Crustal Structure of the Iceland Region from Spectrally Correlated Free-air and Terrain Gravity Data

Seismic refraction studies have provided critical, but spatially restricted constraints on the structure of the Icelandic crust. To obtain a more comprehensive regional view of this tectonically complicated area, we spectrally correlated free-air gravity anomalies against computed gravity effects of the terrain for a crustal thickness model that also conforms to regional seismic and thermal constraints. Our regional crustal thickness estimates suggest thickened crust extends up to 500 km on either side of the Greenland-Scotland Ridge with the Iceland-Faeroe Ridge crust being less extended and on average 3-5 km thinner than the crust of the Greenland-Iceland Ridge. Crustal thickness estimates for Iceland range from 25-35 km in conformity with seismic predictions of a cooler, thicker crust. However, the deepening of our gravity-inferred Moho relative to seismic estimates at the thermal plume and rift zones of Iceland suggests partial melting. The amount of partial melting may range from about 8% beneath the rift zones to perhaps 20% above the plume core where mantle temperatures may be 200-400 C above normal. Beneath Iceland, areally limited regions of partial melting may also be compositionally and mechanically layered and intruded. The mantle plume appears to be centered at (64.6 deg N, 17.4 deg W) near the Vatnajokull Glacier and the central Icelandic neovolcanic zones.

Leftwich, T. E.↗

Orientation illusions and heart-rate changes during short-radius centrifugation

Intermittent short-radius centrifugation is a promising countermeasure against the adverse effects of prolonged weightlessness. To assess the feasibility of this countermeasure, we need to understand the disturbing sensory effects that accompany some movements carried out during rotation. We tested 20 subjects who executed yaw and pitch head movements while rotating at constant angular velocity. They were supine with their main body axis perpendicular to earth gravity. The head was placed at the centrifuge's axis of rotation. Head movements produced a transient elevation of heart-rate. All observers reported head-contingent sensations of body tilt although their bodies remained supine. Mostly, the subjective sensations conform to a model based on semicircular canal responses to angular acceleration. However, some surprising deviations from the model were found. Also, large inter-individual differences in direction, magnitude, and quality of the illusory body tilt were observed. The results have implications for subject screening and prediction of subjective tolerance for centrifugation.

NASA Discipline Neuroscience↗

Multiple Reservoirs of Volatiles in the Moon Revealed by the Isotopic Composition of Chlorine in Lunar Basalts

The isotopes of chlorine (37Cl and 35Cl) are highly fractionated in lunar samples compared to most other Solar System materials. Recently, the chlorine isotope signatures of lunar rocks have been attributed to large-scale degassing processes that occurred during the existence of a magma ocean. In this study we investigated how well a suite of lunar basalts, most of which have not previously been analyzed, conform to previous models. The Cl isotope compositions (δ37Cl (‰) = [(37Cl/35Clsample/37Cl/35ClSMOC) − 1] × 1000, where SMOC refers to standard mean ocean chloride) recorded range from ∼+7 to +14‰ (Apollo 15), +10 to +19‰ (Apollo 12), +9 to +15‰ (70017), +4 to +8‰ (MIL 05035), and +15 to +22‰ (Kalahari 009). The Cl isotopic data from the present study support the mixing trends previously reported by Boyce et al. (2015) and Barnes et al. (2016), as the Cl isotopic composition of apatites are positively correlated with bulk-rock incompatible trace element abundances in the low-Ti basalts, inclusive of low-Ti and KREEP basalts. This trend has been interpreted as evidence that incompatible trace elements, including Cl, were concentrated in the urKREEP residual liquid of the lunar magma ocean, rather than the mantle cumulates, and that urKREEP Cl had a highly fractionated isotopic composition. The source regions for the basalts were thus created by variable mixing between the mantle (Cl-poor and relatively unfractionated) and urKREEP. The high-Ti basalts show much more variability in measured Cl isotope ratios and scatter around the trend formed by the low-Ti basalts. Most of the data for lunar meteorites also fits the mixing of volatiles in their sources, but Kalahari 009, which is highly depleted in incompatible trace elements, contains apatites with heavily fractionated Cl isotopic compositions. Given that Kalahari 009 is one of the oldest lunar basalts and ought to have been derived from very early-formed mantle cumulates, a heavy Cl isotopic signature is likely not related to its mantle source, but more likely to magmatic or secondary alteration processes, perhaps via impact-driven vapor metasomatism of the lunar crust.

Mccubbin, Francis M.↗

Rational Design of Nanoplasmonic Array Geometries for Biosensing

Background: Molecular diagnostics provide early and accurate diagnosis, which is essential for the prevention and treatment of infectious as well as chronic diseases. These tests are designed to detect disease-specific bioanalytes such as nucleic acid (DNA or RNA) or protein (antigens, antibodies) biomarkers. In the context of infectious disease diagnosis, nucleic acid-based detection methods are known to provide more specific and sensitive results. Here, the presence of a unique sequence belonging to the pathogenic genomic material is targeted to identify species, organism, genera and/or antimicrobial resistant gene markers. The majority of the common nucleic acid based diagnostic techniques require amplification (polymerase chain reaction, isothermal amplification etc.) of the pathogenic genetic material prior to detection impacting diagnostic speed, complexity, and cost thereby limiting ease of use. Thus, the development of simplified nucleic acid-based diagnostics that can be even used in resource-poor settings may hugely benefit patients across the globe. Nanopath is a molecular diagnostics company utilizing a solid-state nanosensor to enable sequence-specific detection of target nucleic acids without the need of amplification. These nanostructures enable ultra-sensitive biomarker detection using geometric, feature-dependent properties highly dependent on the local dielectric environment, allowing them to be sensitive to low concentration binding events. This paper describes an application of this approach to provide highly relevant clinical information within a single doctor’s office visit. Intro: The Nanopath team is in collaboration with NASA (National Aeronautics and Space Administration) and NIST (National Institute of Standards and Technology) to push the bounds of the fundamental physics associated with their biosensing platform. The ability of metals to support electromagnetic surface waves gives rise to surface plasmons when optically illuminated. This property, and its strong sensitivity to changes in the local refractive index, allows for the use of metal nanoparticles as ultra-sensitive transducers. In prior work by members of this team, ensembles of randomly oriented nanoparticles (i.e., colloidal nanorods dispersed on chip) were employed for sequence-specific nucleic acid sensing (1-3). While these particle sensors have the advantage of rapid fabrication, they suffer from low sensitivity and quality factor due to the random particle dispersity. In contrast, in this study we employ ordered array nanoparticle ensembles which can be used to improve sensor sensitivity and figure-of-merit. Study Methods Overview: In this talk, we detail the results of sensing experiments and computational simulations to outline a rational design of the structure of these plasmonic nanoparticle arrays for biomolecular sensing. Through simulation and experiment, we iteratively tailor nanostructure dimension to provide high quality signal and large resonance shifts upon modeled nucleic acid binding. In particular, full-wave electromagnetic simulations were conducted using Lumerical photonic simulation software in which periodic boundary conditions were applied in the x- and y- dimensions for each of the nanoplasmonic sensor geometries. To simulate the resonance response to changes in the bulk solution in contact with the sensor surface, the refractive index of the surrounding media was changed appropriately. Nucleic acid hybridization events were modeled using either using spherical structures approximating the relevant radius of genomic material as estimated by polymer models, or as conformal layers with the known refractive indices for nucleic acids. On the basis of initial simulations, nanosensors were fabricated using traditional electron-beam lithography protocols at NIST. To evaluate consensus between simulations and experiments, bulk sensing experiments were carried out in which the resonance peaks were obtained by submerging the sensors in refractive index standards. Key nanosensor characteristics including resonance peak locations, resonance peak shifts as a function of refractive index, and figure of merit (FOM) of extinction curves were examined between the experimental and simulation results prior to proceeding with simulations on additional geometries and more complex solution conditions, and further device fabrication. This iterative process is repeated toward a rational design of nanoplasmonic array geometries for biosensing optimizing response for targeted disease detection. In summary, this study puts forth a methodology for rational design and characterization of regularly spaced nanoparticle arrays for optics-based biosensing. The results of this study will allow for more informed design of nanostructure geometries towards sequence-specific nucleic acid detection. These improved designs have the potential to improve clinical sensitivity and limit-of-detection across disease indication.

sensor↗

Selective deuteration of an RNA:RNA complex for structural analysis using small-angle scattering

The structures of RNA:RNA complexes regulate many biological processes. Despite their importance, protein-free RNA:RNA complexes represent a tiny fraction of experimentally determined structures. Here, we describe a joint small-angle X-ray and neutron scattering (SAXS/SANS) approach to structurally interrogate conformational changes in a model RNA:RNA complex. Using SAXS, we measured the solution structures of the individual RNAs and of the overall RNA:RNA complex. With SANS, we demonstrate, as a proof of principle, that isotope labeling and contrast matching (CM) can be combined to probe the bound state structure of an RNA within a selectively deuterated RNA:RNA complex. Furthermore, we show that experimental scattering data can validate and improve predicted AlphaFold 3 RNA:RNA complex structures to reflect its solution structure. In conclusion, our work demonstrates that in silico modeling, SAXS, and CM-SANS can be used in concert to directly analyze conformational changes within RNAs when in complex, enhancing our understanding of RNA structure in functional assemblies.

HIV-1 dimerization initiation site↗

Quantum fields, geometric fluctuations, and the structure of spacetime

Quantum fluctuations of the vacuum stress-energy tensor are highly non-Gaussian, and can have unexpectedly large effects on spacetime geometry. In this paper, we study a two-dimensional dilaton gravity model coupled to a conformal field, in which the distribution of vacuum fluctuations is well understood. In this model, the fluctuations of the matter field are responsible for the fluctuations of the geometry itself. Here, by analyzing the geodesic deviation in this model, we show that a pencil of massive particles propagating on this fuzzy spacetime eventually converges and collapses. This is consistent with our earlier analysis of null geodesics in [Phys. Rev. Lett. 107, 021303 (2011)].