Search NASA⌕ Search

SEARCH · Search NASA

Results for “Consumption database”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Using DOE Commercial Reference Buildings for Simulation Studies: Preprint

The U.S. Department of Energy developed 256 EnergyPlus models for use in studies that aim to characterize about 70% of the U.S. commercial building stock. Sixteen building types - including restaurants, health care, schools, offices, supermarkets, retail, lodging, and warehouses - are modeled across 16 cities to represent the diversity of U.S. climate zones. Weighting factors have been developedto combine the models in proportions similar to those of the McGraw-Hill Construction Projects Starts Database for 2003-2007. This paper reviews the development and contents of these models and their applications in simulation studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bayesian Structural Time Series for Behind-the-Meter Photovoltaic Disaggregation: Preprint

Distributed photovoltaic (PV) generation often occurs ``behind the meter": a grid operator can only observe the net load, which is the sum of the gross load and distributed PV generation. This lack of observability poses a challenge to system operation at both bulk level and distribution level. The lack of real-time or near-future disaggregated estimates of gross load and PV generation will lead to over scheduling of energy production and regulation reserves, reliability constraints violations, wear and tear of controller devices, and potentially cascading failures of a system. In this paper we propose the use of a Bayesian Structural Time Series (BSTS) model with local solar irradiance measurements to disaggregate the summed PV generation and gross load signals at a downstream measurement site. BSTSs are a highly expressive model class that blends classic time series models with the powerful Bayesian state space estimation framework. Disaggregation is done probabilistically, which automatically quantifies the uncertainties of the estimated PV generation and gross load consumption. Depending on the data availability in real-time, it can be used to disaggragate PV and gross load at customer site, or can be used at the feeder level. In this paper, we focus on solving the problem at feeder level. We compare the performance of a BSTS model as well as a handful of state-of-the-art methods on a Pecan Street AMI dataset, using the National Solar Radiation Database (NSRDB) to estimate local irradiance.

Bayesian structural time series↗

Community and Passenger Survey Responses for Bastrop, Texas Low-Speed Electric Vehicle Mobility Service Project

This document describes the contents of the following data products: 1. ALL-survey_results_NREL_LiveWire_04_14_2023 (Excel file with two worksheets) 2. eCab_DOE_NREL_LiveWire_04_14_2023_results_all_surveys_except_SP_csv (CSV file) 3. eCab_DOE_NREL_LiveWire_04_14_2023_SP_survey_results_only_csv (CSV file). These data products contain the results of the surveys conducted throughout the DOE-funded Electric First-/Last-Mile On-Demand Shuttle Service for Rural Communities in Central Texas project. The Excel file is the original database of all the survey results (contained in two worksheets). The CSV files are those two worksheets saved as individual CSV files.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Topology and burning rates of turbulent, lean, H 2 /air flames

Improved understanding of turbulent flames characterized by negative consumption speed-based Markstein lengths is necessary to develop better models for turbulent lean combustion of high hydrogen content fuels. In this paper we investigate the topology and burning rates of turbulent, lean (φ = 0.31), H 2 /air flames obtained from a recently published DNS database (Aspden et al., 2011). We calculate local flame front curvatures, strain rates, thicknesses, and burning velocities and compare these values to reference quantities obtained from stretched laminar flames computed numerically in three model geometrical configurations-a counterflow twin flame, a tubular counterflow flame and an expanding cylindrical flame. We compare and contrast the DNS with these model laminar flame calculations, and show both where they closely correlate with each other, as well as where they do not. These results in the latter case are shown to result from non-flamelet behaviors, unsteady effects, and curvature-strain correlations. These insights are derived from comparisons conditioned on different topological features, such as portions of the flame front with a spherical/cylindrical shape, the leading edge of the flame, and portions of the flame front with low mean curvature. We also show that reference time scales vary appreciably over the flame, and characterizing the relative values of fluid mechanic and kinetic time scales by a single value leads to erroneous conclusions. For example, there is a two order of magnitude decrease in chemical time scales at the leading edge of the front relative to its unstretched value. In conclusion, for this reason, the leading edge of the front quite closely tracks quasi-steady calculations, even in the lowest Damköhler number case, Da F ~0.005

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistical Analysis of the Phase 3 Emissions Data Collected in the EPAct/V2/E89 Program: January 7, 2010 - July 6, 2012

Phase 3 of the EPAct/V2/E-89 Program investigated the effects of 27 program fuels and 15 program vehicles on exhaust emissions and fuel economy. All vehicles were tested over the California Unified Driving Cycle (LA-92) at 75 degrees F. The program fuels differed on T50, T90, ethanol, Reid vapor pressure, and aromatics. The vehicles tested were new, low-mileage 2008 model year Tier 2 vehicles. A total of 956 test runs were made. Comprehensive statistical modeling and analyses were conducted on methane, carbon dioxide, carbon monoxide, fuel economy, non-methane hydrocarbons, non-methane organic gases, oxides of nitrogen, particulate matter, and total hydrocarbons. In general, model fits determined that emissions and fuel economy were complicated by functions of the five fuel parameters. An extensive evaluation of alternative model fits produced a number of competing model fits. Many of these alternative fits produce similar estimates of mean emissions for the 27 program fuels but should be carefully evaluated for use with emerging fuels with combinations of fuel parameters not included here. The program includes detailed databases on each of the 27 program fuels on each of the 15 vehicles and on each of the vehicles on each of the program fuels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototype Courthouse Building Energy Model: Building Characteristics and Energy Simulation Results

To coordinate commercial building energy research activities, the US Department of Energy uses a suite of commercial prototype building models, which includes 16 building types and covers 80% of US commercial floorspace. Efforts are underway to expand this suite by developing prototype models for additional building types, including a courthouse. Informed by building design guides, databases, documented projects, and personal communication with courthouse design experts, a 3-story, 4-courtroom, 69,324 ft 2 building was considered as the prototype courthouse to represent an average-sized courthouse in the United States. This report documents the building and system characteristics of the prototype courthouse model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. To verify the energy simulation results, energy use statistics of existing courthouses from different building database are also presented. Based on the simulated energy use, the site energy use intensity of the prototype courthouse ranged from 45 to 159 kBtu/ft 2 compared with the average energy use intensity of 94.7 kBtu/ft 2 for the courthouse building type in the 2012 Commercial Building Energy Consumption Survey (CBECS) Data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the Impact of Road Grade on Simulated Commercial Vehicle Fuel Economy Using Real-World Drive Cycles

Commercial vehicle fuel economy is known to vary significantly with both positive and negative road grade. Medium- and heavy-duty vehicles operating at highway speeds require incrementally larger amounts of energy to pull heavy payloads up inclines as road grade increases. Non-hybrid vehicles are then unable to recapture energy on descent and lose energy through friction braking. While the on-road effects of road grade are well understood, the majority of standard commercial vehicle drive cycles feature no climb or descent requirements. Additionally, existing literature offers a limited number of sources that attempt to estimate the on-road energy implications of road grade in the medium- and heavy-duty space. This study uses real-world commercial vehicle drive cycles from the National Renewable Energy Laboratory's Fleet DNA database to simulate the effects of road grade on fuel economy across a range of vocations, operating conditions, and locations. Drive-cycles are matched with vocation-specific vehicle models and simulated with and without grade. Fuel use due to grade is presented, and variation in fuel consumption due to drive cycle and vehicle characteristics is explored through graphical and statistical comparison. The results of this study suggest that road grade accounts for 1%-9% of fuel use in commercial vehicles on average and up to 40% on select routes.

33 ADVANCED PROPULSION SYSTEMS↗

Global, Regional, and National Fossil-Fuel CO2 Emissions: 1751-2017

This data product is a time series of Carbon Dioxide (CO2) emissions from fossil fuel combustion and cement manufacture. Estimates of CO2 emissions are included for the globe and by nation back to 1751, and include emissions from solid fuel consumption, liquid fuel consumption, gas fuel consumption, cement production, and gas flaring. Per capita CO2 emissions and emissions from international trade (bunker fuels) are included as well; bunker fuels are not included in country totals, but are assigned to the country in which loading took place. Estimates are generated using the United Nations Energy Statistics database and the United States Geologic Survey’s cement statistics. Datasets produced from this group at Appalachian State University are located here, and are also located at https://energy.appstate.edu/research/work-areas/cdiac-appstate. Historic CDIAC data from Oak Ridge National Laboratory are located here: https://data.ess-dive.lbl.gov/view/doi:10.3334/CDIAC/00001_V2017. This dataset is the foundational dataset for the annual global carbon budget and other carbon cycle analyses that need relevant fossil fuel CO2 data. Within this data package are spreadsheets (.csv) of global and national estimates of CO2 emissions as well as text files of the ranking of each country’s total CO2 emissions and per capita for that year.

54 ENVIRONMENTAL SCIENCES↗

Evolutionary Tuning of Building Models to Monthly Electrical Consumption

Building energy models of existing buildings are unreliable unless calibrated so they correlate well with actual energy usage. Calibrating models is costly because it is currently an art which requires significant manual effort by an experienced and skilled professional. An automated methodology could significantly decrease this cost and facilitate greater adoption of energy simulation capabilities into the marketplace. The Autotune project is a novel methodology which leverages supercomputing, large databases of simulation data, and machine learning to allow automatic calibration of simulations to match measured experimental data on commodity hardware. This paper shares initial results from the automated methodology applied to the calibration of building energy models (BEM) for EnergyPlus (E+) to reproduce measured monthly electrical data.

Garrett, Aaron↗

A National Thermal Generator Performance Database

This submission contains cleaned and filtered data from the Environmental Protection Agency Clean Air Markets CAM database of thermal power plant operation and performance.

20 FOSSIL-FUELED POWER PLANTS↗

Utility Rate Database

The Utility Rate Database is a free storehouse of rate structure information from utilities in the United States. The database includes rates for utilities based on the authoritative list of U.S. utility companies maintained by the U.S. Department of Energy’s Energy Information Administration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of reduced-order urban scale building energy models

The aim of this study is to demonstrate a developed framework to rapidly create urban scale reduced-order building energy models using a systematic summary of the simplifications required for the representation of building exterior and thermal zones. These urban scale reduced-order models rely on the contribution of influential variables to the internal, external, and system thermal loads. OpenStudio Application Programming Interface (API) serves as a tool to automate the process of model creation and demonstrate the developed framework. The results of this study show that the accuracy of the developed reduced-order building energy models varies only up to 10% with the selection of different thermal zones. In addition, to assess complexity of the developed reduced-order building energy models, this study develops a novel framework to quantify complexity of the building energy models. Consequently, this study empowers the building energy modelers to quantify their building energy model systematically in order to report the model complexity alongside the building energy model accuracy. An exhaustive analysis on four university campuses suggests that the urban neighborhood buildings lend themselves to simplified typical shapes. Specifically, building energy modelers can utilize the developed typical shapes to represent more than 80% of the U.S. buildings documented in the CBECS database. One main benefits of this developed framework is the opportunity for different models including airflow and solar radiation models to share the same exterior representation, allowing a unifying exchange data. Altogether, the results of this study have implications for a large-scale modeling of buildings in support of urban energy consumption analyses or assessment of a large number of alternative solutions in support of retrofit decision-making in the building industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential radon and lung cancer incidence in a Danish cohort

High-level occupational radon exposure is an established risk factor for lung cancer. We assessed the long-term association between residential radon and lung cancer risk using a prospective Danish cohort using 57,053 persons recruited during 1993-1997. We followed each cohort member for cancer occurrence until 27 June 2006, identifying 589 lung cancer cases. We traced residential addresses from 1 January 1971 until 27 June 2006 and calculated radon at each of these addresses using information from central databases regarding geology and house construction. Cox proportional hazards models were used to estimate incidence rate ratios (IRR) and 95% confidence intervals (CI) for lung cancer risk associated with residential radon exposure with and without adjustment for sex, smoking variables, education, socio-economic status, occupation, body mass index, air pollution and consumption of fruit and alcohol. Potential effect modification by sex, traffic-related air pollution and environmental tobacco smoke was assessed. Median estimated radon was 35.8 Bq/m{sup 3}. The adjusted IRR for lung cancer was 1.04 (95% CI: 0.69-1.56) in association with a 100 Bq/m{sup 3} higher radon concentration and 1.67 (95% CI: 0.69-4.04) among non-smokers. We found no evidence of effect modification. We find a positive association between radon and lung cancer risk consistent with previous studies but the role of chance cannot be excluded as these associations were not statistically significant. Our results provide valuable information at the low-level radon dose range.

60 APPLIED LIFE SCIENCES↗

Commercial Buildings Partnership Projects - Metered Data Format and Delivery

A number of the Commercial Building Partnership Projects (CBPs) will require metering, monitoring, data analysis and verification of savings after the retrofits are complete. Although monitoring and verification (M&V) agents are free to use any metering and monitoring devices that they chose, the data they collect should be reported to Pacific Northwest National Laboratory (PNNL) in a standard format. PNNL will store the data collected in its CBP database for further use by PNNL and U.S. Department of Energy. This document describes the data storage process and the deliver format of the data from the M&V agents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improved scintillation detector performance via a method of enhanced layered coatings

Increasing demand for better detection performance with a simultaneous reduction in size, weight and power consumption has motivated the use of compact semiconductors as photo-converters for many gamma-ray and neutron scintillators. The spectral response of devices such as silicon avalanche photodiodes (APDs) is poorly matched to many common high-performance scintillators. We have developed a generalized analytical method that utilizes an optical reference database to match scintillator luminescence to the excitation spectrum of high quantum efficiency semiconductor detectors. This is accomplished by the fabrication and application of a series of high quantum yield, short fluorescence lifetime, wavelengthshifting coatings. Furthermore, we show here a 22% increase in photoelectron collection and a 10% improvement in energy resolution when applying a layered coating to an APD-coupled, cerium-doped, yttrium oxyorthosilicate (YSO:Ce) scintillator. Wavelength-shifted radioluminescence emission and rise time analysis are also discussed.

36 MATERIALS SCIENCE↗

Extending the Brick schema to represent metadata of occupants

Here, energy-related behaviors of occupants constitute a key factor influencing building performance; accordingly, the measured occupant data can support the objective assessment of the indoor environment and energy performance of buildings, which can inform building design and operational decisions. Existing data schemas focus on metadata of sensors, meters, physical equipment, and IoT devices in buildings; however, they are limited in representing the metadata of occupant data, including occupants' presence in spaces, movement between spaces, interactions with building systems or IoT devices, and preference of indoor environmental needs. To address this gap, an extension to the widely adopted metadata schema, Brick, is proposed to represent the contextual, behavioral, and demographic information of occupants. The proposed extension includes four parts: (1) a new “Occupant” class to represent occupants' demography and energy related behavioral patterns, (2) new subclasses under the Equipment class to represent envelope system and personal thermal comfort devices, (3) new subclasses under the Point class to represent occupant sensing and status, and (4) new auxiliary properties for occupant interactable equipment to represent the level of controllability for each piece of equipment by occupants. The extension is implemented in the Brick schema and has been tested using multiple occupant datasets from the ASHRAE Global Occupant Database. The extension enables Brick schema to capture diverse types of occupant sensing data and their metadata for FAIR data research and applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗