Electrokinetic In Situ Treatment of Metal-Contaminated Soil

An electrokinetic technique has been developed as a means of in situ remediation of soils, sludges, and sediments that are contaminated with heavy metals. Examples of common metal contaminants that can be removed by this technique include cadmium, chromium, zinc, lead, mercury, and radionuclides. Some organic contaminants can also be removed by this technique. In the electrokinetic technique, a low-intensity direct current is applied between electrodes that have been implanted in the ground on each side of a contaminated soil mass. The electric current causes electro-osmosis and migration of ions, thereby moving aqueous-phase subsurface contaminants from one electrode to the other. The half reaction at the anode yields H+, thereby generating an acid front that travels from the anode toward the cathode. As this acid front passes through a given location, the local increase in acidity increases the solubility of cations that were previously adsorbed on soil particles. Ions are transported towards one electrode or the other which one depending on their respective electric charges. Upon arrival at the electrodes, the ionic contaminants can be allowed to become deposited on the electrodes or can be extracted to a recovery system. Surfactants and other reagents can be introduced at the electrodes to enhance rates of removal of contaminants. Placements of electrodes and concentrations and rates of pumping of reagents can be adjusted to maximize efficiency. The basic concept of electrokinetic treatment of soil is not new. What is new here are some of the details of application and the utilization of this technique as an alternative to other techniques (e.g., flushing or bioremediation) that are not suitable for treating soils of low hydraulic conductivity. Another novel aspect is the use of this technique as a less expensive alternative to excavation: The cost advantage over excavation is especially large in settings in which contaminated soil lies near and/or under industrial buildings and therefore excavation would be made even more expensive by the need to prevent damage to numerous underground pipes and cables.

Quinn, Jacqueline↗

External Contamination Control of Attached Payloads on the International Space Station

The International Space Station (ISS) is an on-orbit platform for science utilization in low Earth orbit with multiple sites for external payloads with exposure to the natural and induced environments. Contamination is one of the induced environments that can impact performance, mission success and science utilization on the vehicle. This paper describes the external contamination control requirements and integration process for externally mounted payloads on the ISS. The external contamination control requirements are summarized and a description of the integration and verification process is detailed to guide payload developers in the certification process of attached payloads on the vehicle. A description of the required data certification deliverables covers the characterization of contamination sources. Such characterization includes identification, usage and operational data for each class of contamination source. Classes of external contamination sources covered are vacuum exposed materials, sources of leakage, vacuum venting and thrusters. ISS system level analyses are conducted by the ISS Space Environments Team to certify compliance with external contamination control requirements. This paper also addresses the ISS induced contamination environment at attached payload sites, both at the requirements level as well as measurements made on ISS.

Soares, Carlos E.↗

Determining Temperature Differential to Prevent Hardware Cross-Contamination in a Vacuum Chamber

When contamination-sensitive hardware must be tested in a thermal vacuum chamber, cross-contamination from other hardware present in the chamber, or residue from previous tests, becomes a concern. Typical mitigation strategies involve maintaining the temperature of the critical item above that of other hardware elements at the end of the test. A formula for relating the pumping speed of a chamber, the surface area of contamination sources, and the temperatures of the chamber, source, and contamination-sensitive items has been developed. The formula allows the determination of a temperature threshold about which contamination will not condense on the sensitive items. It defines a parameter alpha that is the fraction given by (contaminant source area)/[chamber pumping speed (time under vacuum) 0.5]. If this parameter is less than 10(exp -6), cross-contamination from common spacecraft material will not occur when the sensitive hardware is at the same temperature as the source of contamination (The chamber is isothermal within 5 C.). Knowing when it becomes safe to have the hardware isothermal permits faster and easier thermal transitions when compared with maintaining an arbitrary temperature differential between parts. Furthermore, the standard temperature differential may not be adequate under some conditions (alpha>10(exp -4)).

Hughes, David↗

Evaluation of a Candidate Trace Contaminant Control Subsystem Architecture: The High Velocity, Low Aspect Ratio (HVLA) Adsorption Process

Traditional gas-phase trace contaminant control adsorption process flow is constrained as required to maintain high contaminant single-pass adsorption efficiency. Specifically, the bed superficial velocity is controlled to limit the adsorption mass-transfer zone length relative to the physical adsorption bed; this is aided by traditional high-aspect ratio bed design. Through operation in this manner, most contaminants, including those with relatively high potential energy are readily adsorbed. A consequence of this operational approach, however, is a limited available operational flow margin. By considering a paradigm shift in adsorption architecture design and operations, in which flows of high superficial velocity are treated by low-aspect ratio sorbent beds, the range of well-adsorbed contaminants becomes limited, but the process flow is increased such that contaminant leaks or emerging contaminants of interest may be effectively controlled. To this end, the high velocity, low aspect ratio (HVLA) adsorption process architecture was demonstrated against a trace contaminant load representative of the International Space Station atmosphere. Two HVLA concept packaging designs (linear flow and radial flow) were tested. The performance of each design was evaluated and compared against computer simulation. Utilizing the HVLA process, long and sustained control of heavy organic contaminants was demonstrated.

Kayatin, Matthew J.↗

Cleanroom Contamination Identification Method Development

During fabrication, assembly, and testing of spacecraft and flight hardware it is vital to avoid contaminants that can cause degradation and could result in significant failure. Yet, there is no existing contamination monitoring method that provides the identity of airborne particles in a cleanroom facility. Knowing the particle identities, would allow scientists and engineers to determine the source of the contaminants and prevent setbacks before they occur or cause damage. Current cleanliness monitoring methods include airborne particle counters (APCs), fallout filters, and visual inspections. Particle counts from APCs are the primary metric used to define a cleanroom class and hence its level of cleanliness, but do not provide identification nor can they differentiate between large and small sizes of particles. In addition, using fallout filters is not a proactive, timely, or representative approach to cleanroom contamination monitoring because these samples are only retrieved after 30 days and are placed away from spacecraft processing to avoid interference with operations. In contrast, the forced air sampling method can collect a sample within an hour at any location required and provide results in less than a day. This system uses a cassette and filter sample medium to capture airborne particles which are then taken to a scanning electron microscope with energy dispersive spectroscopy (SEM/EDS) to identify and size the captured particles. Development of forced air sampling into an established laboratory capability will allow for fast sampling and routine identification of unknown contamination sources within the cleanroom. The test method development required market research for an air sampling cassette that increases sample collection efficiency and a filter with low enough background contamination to allow differentiation between a blank (control) and the collected sample. It was determined that a conductive black cassette and a polycarbonate filter were the best options. Conductive black cassettes, in comparison to the standard styrene, are manufactured using polypropylene filled with carbon. This makes the cassette conductive and minimizes the tendency of particles to stick to the wall of the cassette due to electrostatic force. In previous trials a mixed cellulose ester (MCE) filter was used to capture the contaminants, however the rougher surface of the filter contributed to entrapment of the particles within the filter structure and made it harder to identify the particles. In comparison, track etched polycarbonate filters have random cylindrical pores and a smooth surface which contributes to uniform sample distribution on the surface of the filter. Future work includes: testing the system using control samples to determine the efficiency and suitability of the medium, performing sample collection in various environments to establish ideal operating parameters and analyzing contaminant particles using SEM/EDS and assistant characterization techniques. Once fully developed, employing the forced air sampling method will help to prevent damage to spacecraft, avoid schedule delays, and allow for mission success.

Hernandez Melendez, Jailyn M.↗

Source Contaminant Control System Design, Operation, and Testing for the Trash Compaction and Processing System

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). This process involves heating the trash to high temperatures, which in turn releases gaseous contaminants. Effluent management scenarios involve releasing these gases back to the ISS cabin after processing and/or directly venting these gases out to space via the Vacuum Exhaust System (VES). Concerns for recovering the gases back to cabin are crew health, safety, and spacecraft environmental impact. The Heat Melt Compactor (HMC) at NASA Ames Research Center (ARC) serves as a test system that supports TCPS development by conducting risk reduction activities associated with an ISS flight demonstration. Previous gas effluent studies were conducted on the HMC. The results consisted of contaminants from the trash exhaust to exceed Spacecraft Maximum Allowable Concentrations (SMAC), which are selected airborne contaminants that can elicit toxicity symptoms to crewmembers via exposure. The Source Contaminant Control System (SCCS) aims to reduce that risk by converting the contaminants into carbon dioxide (CO2) and water (H2O) vapor. The SCCS is composed of a carbon adsorbent bed, to avoid catalyst poisoning, and a catalytic oxidizer (CatOx), which promotes oxidation of the contaminants to CO2 and H2O. In turn, the gases coming out of the SCCS should be compatible to the ISS cabin and systems such as the Trace Contaminant Control System (TCCS). Preparation for SCCS testing alongside the HMC Gen 3 are currently underway at ARC. The main objectives are to evaluate CatOx efficiency by CO2 conversion and characterize effectiveness of removal by comparing contaminant results before and after CatOx. This paper will report on the SCCS design, operation, and testing with results.

Janine Young↗

JPL Contamination Control Engineering

JPL has extensive expertise fielding contamination sensitive missions-in house and with our NASA/industry/academic partners.t Development and implementation of performance-driven cleanliness requirements for a wide range missions and payloads - UV-Vis-IR: GALEX, Dawn, Juno, WFPC-II, AIRS, TES, et al - Propulsion, thermal control, robotic sample acquisition systems. Contamination control engineering across the mission life cycle: - System and payload requirements derivation, analysis, and contamination control implementation plans - Hardware Design, Risk trades, Requirements V-V - Assembly, Integration & Test planning and implementation - Launch site operations and launch vehicle/payload integration - Flight ops center dot Personnel on staff have expertise with space materials development and flight experiments. JPL has capabilities and expertise to successfully address contamination issues presented by space and habitable environments. JPL has extensive experience fielding and managing contamination sensitive missions. Excellent working relationship with the aerospace contamination control engineering community/.

Molecular Contamination Spectral Effects (MCSE) Ch↗

Development of the Contamination Distribution Centered Toxics Mobility Vulnerability Index in the Beaumont–Port Arthur Region of Texas

This study advances the Toxics Mobility Inventory (TMI) and the Toxics Mobility Vulnerability Index (TMVI) to develop a new tool to assess the movement of hazardous substances and their implications for vulnerable communities. It emphasizes the need to include contamination distribution variables in such indices to address disproportionate impacts and more accurately reflect vulnerability. The study uses the TMI framework and TMVI methodology in the Beaumont–Port Arthur region of Texas, also integrating contamination distribution considerations into the analysis to develop a new framework and process. The new Contamination Distribution Centered Toxics Mobility Vulnerability Index (CDC-TMVI) consolidates climate change and topography variables into a broader built environment vulnerability category while introducing a contamination sources category. Using ArcGIS Pro and ToxPi tools, the study evaluates 27 geospatial variables across four categories: built environment vulnerability, social vulnerability, health outcomes, and contamination sources. The results indicate significant contributions from contamination and social vulnerability variables, highlighting areas with higher risks of flooding and air pollution. This article advocates for future research and policy efforts to enhance the integration of contamination sources and their spatial distributions into toxics mobility assessments to better protect vulnerable populations. Furthermore, the unique methodology and findings serve as a basis for developing targeted measures and strategic planning to improve environmental health.

contamination↗

Assessment of the Impact of the Single Stream Recycling on Paper Contamination in Recovery Facilities and Paper Mills

Contaminated recyclables pose one of the largest roadblocks to an effective implementation of a circular economy system. Current knowledge surrounding the effects of various recycling methods on contamination rates is limited, thus preventing effective quantification of contamination effects. This study aims to fill this knowledge gap by assessing the impact of single stream recycling on paper contamination in MRFs and their end-products based on different composition studies conducted by facilities nationwide. This project expects to provide the foundational knowledge that could catalyze significant cost savings and energy consumption at MRFs and paper mills by understanding the levels of inbound and outbound contamination rates in SSR systems. Statistical analysis conducted in this project utilizes the available nationwide inbound and outbound samples collected as part of material composition and audit studies to identify and measure the significance of various factors on the resultant contamination levels. The research results provide benefits to both the recycling industry and its customers by addressing the causes and impact of contamination in recycled products, particularly with the wide applicability of single stream recycling within the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Contaminant Source Identification from Finite Sensor Data: Perron–Frobenius Operator and Bayesian Inference

Sensors in the built environment ensure safety and comfort by tracking contaminants in the occupied space. In the event of contaminant release, it is important to use the limited sensor data to rapidly and accurately identify the release location of the contaminant. Identification of the release location will enable subsequent remediation as well as evacuation decision-making. In previous work, we used an operator theoretic approach—based on the Perron–Frobenius (PF) operator—to estimate the contaminant concentration distribution in the domain given a finite amount of streaming sensor data. In the current work, the approach is extended to identify the most probable contaminant release location. The release location identification is framed as a Bayesian inference problem. The Bayesian inference approach requires considering multiple release location scenarios, which is done efficiently using the discrete PF operator. The discrete PF operator provides a fast, effective and accurate model for contaminant transport modeling. The utility of our PF-based Bayesian inference methodology is illustrated using single-point release scenarios in both two and three-dimensional cases. The method provides a fast, accurate, and efficient framework for real-time identification of contaminant source location.

42 ENGINEERING↗

Contamination Results of MISSE 8 Wake and Nadir Samples After 2 Years of Space Exposure on the International Space Station

Spacecraft in low Earth orbit (LEO) are subjected to harsh environmental conditions, including radiation (cosmic rays, ultraviolet, x-ray and charged particle radiation), micrometeoroids and orbital debris, temperature extremes, thermal cycling, and atomic oxygen. In addition, on-orbit spacecraft contamination is a serious spaceflight issue, with silicone contamination being a particular concern. In an effort to understand on-orbit contamination of Materials International Space Station Experiment 8 (MISSE 8) flight samples and other International Space Station (ISS) payloads, contamination studies were conducted post-flight on retrieved Teflon fluorinated ethylene propylene (FEP) samples flown in the wake and nadir orientations on MISSE 8. The wake sample was Teflon FEP (M8-W11) flown as part of the Glenn MISSE 8 Polymers Experiment on the Optical Reflector Materials Experiment-III Ram/Wake (ORMatE-III R/W) tray and exposed to the LEO wake environment for 2.0 years. The nadir samples were silver-Teflon FEP radiator pieces taken from the MISSE 8 Single Events Upset Xilinx-Sandia Experiment II (SEUXSE II) Power Box and exposed to the LEO nadir environment for 2.14 years. The Teflon FEP flight materials were analyzed for changes in surface morphology and chemistry as compared to pristine control samples. The wake samples were also analyzed for changes in optical properties. There was no evidence of a molecular contamination layer present on the surface of the MISSE 8 wake or nadir facing Teflon FEP flight samples, although both the wake and nadir flight samples contained particulate contamination in some regions. The analyzed nadir particles were primarily zinc rich. The majority of analyzed wake particles were comprised of oxidized aluminum with small amounts of zinc and magnesium. The wake particles appear to have arrived early in the mission (or pre-flight) during a single event. This paper provides details of the MISSE 8 sample contamination analyses.

Erosion↗

Updates to a Preliminary Probabilistic Performance Assessment Model for Radiological and Chemical Contamination at the West Valley Site, New York - 20420

The New York State Energy Research and Development Authority (NYSERDA) is the owner of the Western New York Nuclear Service Center (WNYNSC), a 1,351-ha site located approximately 48 km south of Buffalo, New York. In 1962, Nuclear Fuel Services, Inc. (NFS) entered into agreements with the Atomic Energy Commission and New York State to construct the first commercial reprocessing plant of nuclear fuel in the United States at the WNYNSC. NFS built and operated the spent fuel reprocessing plant and waste disposal facilities, processing 640 Mg (640 metric tons) of spent nuclear fuel from 1966 to 1972 under an Atomic Energy Commission license. Nuclear fuel reprocessing operations halted in 1972 and never restarted, leaving behind radioactive and chemical wastes. The U.S. Department of Energy (DOE) was required to complete certain waste management activities under the West Valley Demonstration Project (WVDP) Act of 1980 including decommissioning of WVDP facilities. As collaborating agencies, NYSERDA and the DOE are tasked with making decisions about decommissioning and risk reduction for the West Valley Site. Neptune and Company, Inc. (Neptune) was contracted to develop a probabilistic performance assessment (PPA) model to assist the agencies in their decision making process for decommissioning the WVDP and WNYNSC. One important tool that is needed in order to inform the decision-making process is a science-based model of the West Valley Site that evaluates potential future consequences for human health and the environment. This forms the core of the spatial domain of the West Valley PPA Model. The PPA Model, developed using the GoldSim system modeling software, is a tool intended to provide support for decision making that evaluates uncertainty, in a manner that is transparent, defensible, and robust. The PPA Model includes contaminant transport and health effects components, and is organized around geographically-grouped contaminated facilities. These include the waste disposal areas licensed by the U.S. Nuclear Regulatory Commission and the State of New York, a waste tank farm for storage of high level radioactive waste resulting from reprocessing operations, and several areas contaminated with radioactive and chemical constituents. The PPA Model evaluates contaminant transport from these sources to points of exposure across the site and into receiving surface waters and sediments. Hypothetical people and wildlife could be exposed to contamination at these locations, and the effects of these exposures are evaluated. Contaminant transport processes to be evaluated in the PPA Model include groundwater and surface water transport, contaminant translocation by plants and animals, diffusion, and erosion. The evaluation of exposures to people in this preliminary model is limited to a resident farmer scenario, and ecological assessment is performed at the level of a screening analysis. The results of these preliminary evaluations inform future model developments. PPA Model results are subjected to sensitivity analysis in order to determine those pathways and parameters that are most significant in influencing the results. This information allows analysts and decision makers to focus on those aspects of Site behavior and processes. With this information, the decision makers can drive informed, defensible decisions regarding decommissioning of the Site. This paper includes an update of the information presented at WM2019 [1]. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impacts on product quality attributes of monoclonal antibodies produced in CHO cell bioreactor cultures during intentional mycoplasma contamination events

Abstract A mycoplasma contamination event in a biomanufacturing facility can result in costly cleanups and potential drug shortages. Mycoplasma may survive in mammalian cell cultures with only subtle changes to the culture and penetrate the standard 0.2‐µm filters used in the clarification of harvested cell culture fluid. Previously, we reported a study regarding the ability of Mycoplasma arginini to persist in a single‐use, perfusion rocking bioreactor system containing a Chinese hamster ovary (CHO) DG44 cell line expressing a model monoclonal immunoglobulin G 1 (IgG1) antibody. Our previous work showed that M. arginini affects CHO cell growth profile, viability, nutrient consumption, oxygen use, and waste production at varying timepoints after M. arginini introduction to the culture. Careful evaluation of certain identified process parameters over time may be used to indicate mycoplasma contamination in CHO cell cultures in a bioreactor before detection from a traditional method. In this report, we studied the changes in the IgG1 product quality produced by CHO cells considered to be induced by the M. arginini contamination events. We observed changes in critical quality attributes correlated with the duration of contamination, including increased acidic charge variants and high mannose species, which were further modeled using principal component analysis to explore the relationships among M. arginini contamination, CHO cell growth and metabolites, and IgG1 product quality attributes. Finally, partial least square models using NIR spectral data were used to establish predictions of high levels (≥10 4 colony‐forming unit [CFU/ml]) of M. arginini contamination, but prediction of levels below 10 4 CFU/ml were not reliable. Contamination of CHO cells with M. arginini resulted in significant reduction of antibody product quality, highlighting the importance of rapid microbiological testing and mycoplasma testing during particularly long upstream bioprocesses to ensure product safety and quality.

60 APPLIED LIFE SCIENCES↗

Decontamination of urban surfaces contaminated with radioactive materials and consequent onsite recycling of the waste water

Enhancing rapid remediation strategies is paramount for recovery after a large-scale nuclear contamination event in an urban environment. Some current strategies recommend use of readily available equipment, materials, and facilities to expedite recovery. For example, applying pressurized water to contaminated surfaces may effectively remove radioactive contamination. In this study, a commercial power washer removes soluble forms of 152 Eu 3 + , 85 Sr 2 + , and 137 Cs + contamination from common porous building materials, and computer simulations characterize the recycling of the resultant contaminated wash water. Pressure washing the porous building materials under spray conditions typical with do-it-yourself units improved decontamination factors (DFs) for 152 Eu compared to low-pressure application of tap water (majority of two-tailed t-test p-values < 0.1), but pressure did not improve DFs for 137 Cs or 85 Sr. For both pressurized and low-pressure applications, adding potassium ions (K + ) to promote ion exchange reactions produced significantly higher DFs for tested radionuclides on asphalt, brick, and concrete. The resultant contaminated wash water can be processed through self-prepared chemical filtration beds of clay and sand. Modeled in a prior study, the beds yielded linear trends (R 2 > 0.98) in sensitivity analyses between most bed configuration variables and bed performance variables, permitting flexible ad-hoc bed design. The experimental and simulation results led to estimates of the remediation rate and waste generated after cleaning 250 m 2 of cesium-contaminated concrete from the combined deployment of a power washer and two different mobile treatment beds. Furthermore, the first treatment bed was designed to reduce treatment time and processed 1900 L of wash solution in 70 min using 880 kg of clay/sand infill material. Designed to reduce the solid waste generated, the second bed processed the same solution volume in 1040 min (17 h) using 170 kg of clay/sand infill material. The results of this analysis warrant further investigation of power washing with recycled salt solution as an effective rapid decontamination method with manageable waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent-mediated contaminant removal from plastic waste using thermodynamic modeling

Plastics recycling is hindered by the compositional complexity of plastic waste, which can include numerous polymer components as well as low concentrations of additives and non-intentionally added substances. These latter small-molecule species, which we collectively refer to as contaminants, can harm human health and will build up in recycled plastic causing environmental and downstream processing challenges if not removed. In this work, we present molecular modeling approaches using the COnductor-like Screening MOdel for Real Solvents (COSMO-RS) to guide the selection of solvents that are capable of removing targeted contaminants from plastic waste. By considering the thermodynamic partitioning of contaminant species between a solvent phase and polymer phase, we identify guidelines for solvent selection to promote either the low-temperature extraction of contaminants from plastic waste or the removal of contaminants as part of a dissolution-based plastics recycling process. We present four case studies to illustrate the application of the computational approach to the removal of brominated flame retardants, phthalates, and selected perfluoroalkyl substances, and compare to both literature and newly collected experimental data to illustrate model prediction accuracy. Furthermore, the case studies highlight the capability of the modeling approach to help design recycling processes that explicitly account for contaminant removal, thereby increasing product purity during dissolution-based recycling or facilitating chemical recycling of contaminant-free plastics.

Zhou, Panzheng [University of, Wisconsin, Madison,↗

Accumulation of trace elements in soil and fauna within a site historically contaminated with coal combustion residues

Legacy contaminants tied to energy production are a worldwide concern. Coal combustion residues (CCRs) contain high concentrations of potentially toxic trace elements such as arsenic (As), mercury (Hg), and selenium (Se), which can persist for decades after initial contamination. Coal combustion residue disposal methods, including aquatic settling basins and landfills, can facilitate environmental exposure through intentional and accidental releases. Wildlife exposed to CCRs can experience numerous deleterious effects, such as on development, reproduction, and survival. In the current study, we quantified and compared concentrations of As, Hg, Se, and strontium (Sr) within soils and target fauna (three vertebrate and three invertebrate taxa) from a CCR-contaminated site and a reference site within the U.S. Department of Energy’s Savannah River Site, South Carolina, United States. Our objectives were to (1) compare current concentrations of tested elements in soil and resident fauna to levels from our reference site, (2) assess natural attenuation of elements in soils by comparing current concentrations to historic levels, and (3) evaluate the biomagnification potential of the elements measured via body burden and trophic position correlations among fauna. Here, element concentrations were higher in contaminated soils than reference soils; however, concentrations in 2022 were unchanged from concentrations measured in 2003, suggesting no natural attenuation of tested elements. Additionally, target fauna had elevated As, Se, and Sr levels in comparison to reference samples. A positive correlation was observed in southern toads between Sr concentrations and trophic position, as assessed by nitrogen stable isotope ratios, suggesting potential for biomagnification of Sr within our study system. Collectively, our results demonstrate that legacy contaminants are still present and bioaccumulate in a diversity of taxa in a CCR-contaminated site that has not received effluents in more than 50 years, suggesting monitoring programs in CCR-contaminated sites should be maintained long term in the absence of remediation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Correcting correlation functions for redshift-dependent interloper contamination

ABSTRACT The construction of catalogues of a particular type of galaxy can be complicated by interlopers contaminating the sample. In spectroscopic galaxy surveys this can be due to the misclassification of an emission line; for example in the Hobby–Eberly Telescope Dark Energy Experiment (HETDEX) low-redshift [O ii] emitters may make up a few per cent of the observed Ly α emitter (LAE) sample. The presence of contaminants affects the measured correlation functions and power spectra. Previous attempts to deal with this using the cross-correlation function have assumed sources at a fixed redshift, or not modelled evolution within the adopted redshift bins. However, in spectroscopic surveys like HETDEX, where the contamination fraction is likely to be redshift dependent, the observed clustering of misclassified sources will appear to evolve strongly due to projection effects, even if their true clustering does not. We present a practical method for accounting for the presence of contaminants with redshift-dependent contamination fractions and projected clustering. We show using mock catalogues that our method, unlike existing approaches, yields unbiased clustering measurements from the upcoming HETDEX survey in scenarios with redshift-dependent contamination fractions within the redshift bins used. We show our method returns autocorrelation functions with systematic biases much smaller than the statistical noise for samples with at least as high as 7 per cent contamination. We also present and test a method for fitting for the redshift-dependent interloper fraction using the LAE–[O ii] galaxy cross-correlation function, which gives less biased results than assuming a single interloper fraction for the whole sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance Losses and Current-Driven Recovery from Cation Contaminants in PEM Water Electrolysis

Water contaminants are a common cause of failure for polymer electrolyte membrane (PEM) electrolyzers in the field as well as a confounding factor in research on cell performance and durability. In this study, we investigated the performance impacts of feed water containing representative tap water cations at concentrations ranging from 0.5–500 μ M, with conductivities spanning from ASTM Type II to tap-water levels. We present multiple diagnostic signatures to help identify the presence of contaminants in PEM electrolysis cells. Through analysis of polarization curves and impedance spectroscopy to understand the origins of performance losses, we found that a switch from the acidic to alkaline hydrogen evolution mechanism is a key factor in contaminated cell behavior. Finally, we demonstrated that this mechanism switching can be harnessed to remove cation contaminants and recover cell performance without the use of an acid wash. We demonstrated near-complete recovery of cells contaminated with sodium and calcium, and partial recovery of a cell contaminated with iron, which was further investigated by post-mortem microscopy. The improved understanding of contaminant impacts from this work can inform development of strategies to mitigate or recover performance losses as well as improve the consistency and rigor of electrolysis research.