Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contaminants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Exploration of methods to remove implanted 210 Pb and 210 Po contamination from silicon surfaces

Radioactive contaminants on the surfaces of detector components can be a problematic source of background events for physics experiments searching for rare processes. Exposure to radon is a specific concern because it can result in the relatively long-lived 210 Pb (and progeny) being implanted to significant subsurface depths such that removal is challenging. Here, in this article, we present results from a broad exploration of cleaning treatments to remove implanted 210 Pb and 210 Po contamination from silicon, which is a material frequently used in rare-events searches. We demonstrate for the first time that heat treatments (“baking”) can effectively mitigate such surface contamination, with a 1200 °C bake resulting in a 97$^{+2}_{-3}$% reduction. We also report results using wet-chemistry and plasma-based methods, which show that etching can be highly effective provided the etch depth is sufficiently aggressive. Our survey of cleaning methods suggests consideration of multiple approaches during the different phases of detector construction to enable greater flexibility for efficient removal of 210 Pb and 210 Po surface contamination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exposure, health effects, sensing, and remediation of the emerging PFAS contaminants – Scientific challenges and potential research directions

Per- and polyfluoroalkyl substances (PFAS) make up a large group of persistent anthropogenic chemicals which are difficult to degrade and/or destroy. PFAS are an emerging class of contaminants, but little is known about the long-term health effects related to exposure. In addition, technologies to identify levels of contamination in the environment and to remediate contaminated sites are currently inadequate. In this opinion-type discussion paper, a team of researchers from the University of Connecticut and the University at Albany discuss the scientific challenges in their specific but intertwined PFAS research areas, including rapid and low-cost detection, energy-saving remediation, the role of T helper cells in immunotoxicity, and the biochemical and molecular effects of PFAS among community residents with measurable PFAS concentrations. Potential research directions that may be employed to address those challenges and improve the understanding of sensing, remediation, exposure to, and health effects of PFAS are then presented. Here, we hope our account of emerging problems related to PFAS contamination will encourage a broad range of scientific experts to bring these research initiatives addressing PFAS into play on a national scale.

Challenges and research directions↗

Analysis of beam ion driven Alfvén eigenmode stability induced by Tungsten contamination in EAST

Alfvén eigenmodes (AE) activity is observed in the EAST high β N and low B T discharge 93910, operation scenario dedicated to explore the ITER baseline scenario. AEs are triggered after the plasma is contaminated by Tungsten that causes an abrupt variation of the thermal plasma and energetic particles (EPs) profiles. The aim of the present study is to analyze the AE stability in the 93910 discharge using the gyro-fluid code FAR3d, identifying the AE stability trends by comparing the plasma before and after the Tungsten contamination. Tungsten contamination causes the destabilization of Toroidal AEs (TAE) and Energetic particle modes (EPMs) in the same frequency range and radial location with respect to the experimental observation and M3D-K/GTAW code results. Next, a set of parametric studies are performed to analyze the effect of the thermal plasma and EP parameters on the AE stability. The analysis indicates a lower EP β threshold for the AEs destabilization if the EP energy increases, an improved AE stability of on-axis NBI configurations due to the stronger continuum damping in the inner plasma region as well as a large enhancement of the EP drive as the thermal ion density increases due to a higher ratio of the EP and Alfven velocities. Consequently, the simulations indicate the increment of the thermal ion density after the Tungsten contamination could be the main cause of the AE/EPM destabilization.

AE↗

Mixed waste contamination selects for a mobile genetic element population enriched in multiple heavy metal resistance genes

Abstract Mobile genetic elements (MGEs) like plasmids, viruses, and transposable elements can provide fitness benefits to their hosts for survival in the presence of environmental stressors. Heavy metal resistance genes (HMRGs) are frequently observed on MGEs, suggesting that MGEs may be an important driver of adaptive evolution in environments contaminated with heavy metals. Here, we report the meta-mobilome of the heavy metal-contaminated regions of the Oak Ridge Reservation subsurface. This meta-mobilome was compared with one derived from samples collected from unimpacted regions of the Oak Ridge Reservation subsurface. We assembled 1615 unique circularized DNA elements that we propose to be MGEs. The circular elements from the highly contaminated subsurface were enriched in HMRG clusters relative to those from the nearby unimpacted regions. Additionally, we found that these HMRGs were associated with Gamma and Betaproteobacteria hosts in the contaminated subsurface and potentially facilitate the persistence and dominance of these taxa in this region. Finally, the HMRGs were associated with conjugative elements, suggesting their potential for future lateral transfer. We demonstrate how our understanding of MGE ecology, evolution, and function can be enhanced through the genomic context provided by completed MGE assemblies.

59 BASIC BIOLOGICAL SCIENCES↗

A Review of the Resuspension of Radioactively Contaminated Particles by Vehicle and Pedestrian Traffic—Current Theory, Practice, Gaps, and Needs

Here, the resuspension of radioactively contaminated particles in a built environment, such as from urban surfaces like foliage, building exteriors, and roadways, is described empirically by current plume and dosimetry models used for hazard assessment and long-term risk purposes. When applying these models to radiological contamination emergencies affecting urban areas, the accuracy of the results for recent contamination deposition is impacted in two main ways. First, the data supporting the underlying resuspension equations was acquired for open, quiescent conditions with no vehicle traffic or human activities, so it is not necessarily representative of the urban environment. Second, mechanical disturbance by winds in urban canyons and during emergency operations caused by vehicle traffic and human activities are not directly considered by the equations. Accordingly, plume and dosimetry models allow the user to input certain compensating values, but the models do not necessarily supply users instructions on what values to use. This manuscript reviews the available literature to comprehensively and consistently pool data for resuspension due to mechanically induced resuspension applicable to urban contamination. Because there are few studies that directly measured radioactive resuspension due to vehicles and pedestrians, this review novelly draws on a range of other studies involving non-radioactive particles, ranging from outdoor air pollution emissions to indoor allergen transport. The results lead to tabulated, recommended values for specific conditions in the emergency phase to help users of plume and dosimetry models maintain the conservativeness needed to properly capture the potential radiation dose posed by mechanically induced resuspension. These values are of benefit to model users until better data are available. The results also suggest the types of data that may result in improved plume and dose modeling.

61 RADIATION PROTECTION AND DOSIMETRY↗

Data-driven method to estimate contamination from light ion beam transmutation at colliders

Collisions of relativistic light ions, such as oxygen, neon, and magnesium, have been proposed as a way to examine the system-size dependence of dynamics typically associated with the quark-gluon plasma produced in collisions of heavier ions such as xenon, gold, or lead. Recent efforts at both the Relativistic Heavy Ion Collider (RHIC) and Large Hadron Collider (LHC) have produced large datasets of proton-oxygen, oxygen-oxygen, and neon-neon collisions, catalyzing intense interest in experimental backgrounds associated with light-ion collisions. In particular, electromagnetic dissociation of light ions while they are circulating in a collider can result in beam contamination that is difficult to simulate precisely. Here we propose a data-driven method for evaluating the potential impact of beam contaminants on physics analyses. The method exploits the time dependence and smaller size of contaminant ion species to define control regions that can be used to quantify potential contamination effects. A simple model is used to illustrate the method and to study its robustness. Furthermore, this method can inform studies of recent LHC and RHIC data and could also be useful for future light-ion programs at the LHC and beyond.

Beam loss↗

Co-occurrence of antibiotic, biocide, and heavy metal resistance genes in bacteria from metal and radionuclide contaminated soils at the Savannah River Site

Contaminants such as heavy metals may contribute to the dissemination of antimicrobial resistance (AMR)by enriching resistance gene determinants via co-selection mechanisms. In the present study, a survey was performed on soils collected from four areas at the Savannah River Site (SRS), South Carolina, USA, with varying contaminant profiles: relatively pristine(Upper Three Runs), heavy metals (Ash Basins), radionuclides (Pond B) and heavy metal and radionuclides (Tim’s Branch). Using 16S rRNA gene amplicon sequencing, we explored the structure and diversity of soil bacterial communities. Sites with legacies of metal and/or radionuclide contamination displayed significantly lower bacterial diversity compared to the reference site. Metagenomic analysis indicated that multidrug and vancomycin antibiotic resistance genes (ARGs) and metal resistance genes (MRGs) including those associated with copper, arsenic, iron, nickel and zinc were prominent in all soils including the reference site. However, significant differences were found in the relative abundance and diversity of certain ARGs and MRGs in soils with metal/radionuclide contaminated soils compared to the reference site. Co-occurrence patterns revealed significant ARG/MRG subtypes in predominant soil taxa including Acidobacteriaceae, Bradyrhizobium, Mycobacterium, Streptomyces, Verrumicrobium, Actinomadura and Solirubacterales. Overall, the study emphasizes the potential risk of human activities on the dissemination of AMR in the environment.

59 BASIC BIOLOGICAL SCIENCES↗

Contaminant Cation Effect on Oxygen Transport through the Ionomers of Polymer Electrolyte Membrane Fuel Cells

We characterized the effects of cobalt (Co 2+ ) and other cation contaminants on the oxygen (O 2 ) transport properties of the PFSA ionomer used in polymer electrolyte membrane fuel cells (PEMFCs) and gained insight into the mechanisms by which contaminant cations inhibit O 2 transport. Such cations can be released by alloy catalysts and environmental conditions and pose a significant challenge to maintaining high current density performance with low platinum (Pt) loadings. We used a test cell capable of isolating the ionomer from the membrane electrode assembly (MEA), allowing for O 2 transport resistance (R O2 ) measurements using a limiting current technique. We contaminated ionomer membranes with Li + , Na + , Ni 2+ , Co 2+ , and Ce 3+ and found a general increase in R O2 for increased contamination levels and decreased water activity. In addition, our Co 2+ results indicated distinct concentration-dependent regimes. The other cation-form ionomers allowed us to separate the impacts of ion pair strength, multivalency, and reduced water uptake. We believe that these factors cause a more compressed hydrophilic domain and tortuous O 2 diffusion path, and a commensurate increase in R O2 . Lastly, we studied the impact of Co 2+ on an operating PEMFC and found an increase in R O2 consistent with the results of our isolated membrane tests.

25 ENERGY STORAGE↗

A novel approach to mitigating the potential release of radioisotopes under fire conditions - enhancing fire resiliency of radiological contamination fixatives during deactivation & decommissioning activities

Savannah River National Laboratory (SRNL), in close collaboration with the Florida International University Applied Research Center (FIU ARC), successfully executed a technology development activity on behalf of the Department of Energy, Office of Environmental Management (DOE EM). The purpose of the activity was to improve the capability of fixative technologies in immobilizing residual contamination when exposed to thermal stressors as postulated in accident scenarios in Basis for Interim Operations (BIO) documents across the DOE EM complex. The effort resulted in the test and evaluation of a down-selected, commercial-off-the-shelf (COTS) intumescent technology in a radioactive environment at the Savannah River Site (SRS) Building 235-F Plutonium Fuel Form (PuFF) Facility and highlighted the potential use of this technology as a stand-alone, fire retardant fixative. Furthermore, this activity highlighted significant shortfalls in common fixatives currently used to support decommissioning activities and brought to the forefront the need for a methodical, uniformed approach to certifying fixative technologies for operational use in Deactivation and Decommissioning (D&D) activities. An essential component of this research was to evaluate the state of industry fixatives currently in use and set the foundation for comparison to alternative technological solutions. A baseline of five (5) commonly used fixatives and decontamination gels (hereafter collectively referred to as fixatives) was conducted, and notable shortfalls and deficiencies were revealed, particularly when exposed to thermal, water, and other environmental stressors. At temperatures as low as 300 °F - 400 °F (148.89 °C – 204.44 °C), all commonly used fixatives melted from the substrates within 3-5 minutes of exposure, resulting in contaminant transport. Significant degradation in terms of mass loss, desiccation, and off-gassing occurred, and the chemical breakdown of the polymer was so complete researchers assessed there would likely have been a release of residual contamination. Additional vulnerabilities became evident when exposed to water immersion and high humidity; existing fixatives took up water, swelling and frequently delaminating from the substrate, once again increasing the likelihood of a contaminant release.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of Electrode Contamination Mitigation at 0.5 MA Scale

The Z Machine at Sandia National Laboratories uses current pulses with peaks up to 27 MA to drive target implosions and generate high energy density conditions of interest for stockpile stewardship programs pertinent to the NNSA program portfolio . Physical processes in the region near the Z Machine target create electrode plasmas which seed parasitic current loss that reduce the performance and output of a Z experiment. Electrode surface contaminants (hydrogen, water, hydrocarbons) are thought to be the primary constituent of electrode plasmas which contribute to loss mechanisms. The Sandia team explore d in situ heating and plasma discharge techniques by integrating requisite infrastructure into Sandia's Mykonos LTD accelerator, addressing potential impacts to accelerator operation, and reporting on the impact of these techniques on electrode plasma formation and shot performance. The in situ discharge cleaning utilizes the electrodes of the accelerator to excite an argon-oxygen plasma to sputter and chemically react contaminants from electrode surfaces. Insulating breaks are required to isolate the plasma in electrode regions where loss processes are most likely to occur. The shots on Mykonos validate that these breaks do not perturb experiment performance, reducing the uncertainty on the largest unknown about the in situ cleaning system. Preliminary observations with electrical and optical diagnostics suggest that electrode plasma formation is delayed, and overall inventory has been substantively reduced. In situ heating embeds cartridge heaters into accelerator electrodes and employs a thermal bakeout to rapidly desorb contaminants from electrode surfaces. For the first time, additively manufactured (AM) electrode assemblies were used on a low impedance accelerator to integrate cooling channels and manage thermal gradients. Challenges with poor supplier fabrication to specifications, load alignment, thermal expansion and hardware movement and warpage appears to have introduced large variability in observed loss, though, preventing strong assertions of loss reduction via in situ heating. At this time, an in situ discharge cleaning process offers the lowest risk path to reduce electrode contaminant inventories on Z, though we recommend continuing to develop both approaches. Additional engineering and testing are required to improve the implementation of both systems. .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Predictive Contaminant Transport Simulation with the P2R Model for the Composite Analysis Inventory Sensitivity Case

The Plateau to River (P2R) Model is a groundwater flow and contaminant fate and transport (F&T) simulation model used to support remedial activities conducted by the Central Plateau Cleanup Company (CPCCo) at the Hanford Site in Washington State. The model simulates contaminants of concern within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. The overall objective of the saturated zone modeling effort is to provide a basis for making informed remedial action decisions based on descriptions of current and expected future contaminant concentrations in groundwater at decision points within and downgradient of the Central Plateau of the Hanford Site. Specifically, the purpose of this environmental calculation file (ECF) is to describe an inventory sensitivity case of the CA base case. The inventory sensitivity case implements a change in the activity contribution from the vadose zone in the A Trenches Area model (for tritium (H-3) and iodine-129 (I-129)), BC Cribs and Trenches model (for I-129 and technetium-99 (Tc-99)), and the PUREX Area model (for H-3 and I-129). All other simulated inventories are identical to the CA base case. The simulation of F&T of contaminants reported in this case will support dose predictions as part of the Hanford Site CA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vertical Characterization of Flow and Contaminant Concentration in New Hanford Extraction Wells

Effective groundwater remediation should focus on high-concentration, low-permeability zones within the aquifer, as these areas often present significant challenges to contaminant removal. Characterizing the vertical distribution of contamination in an aquifer is therefore critical for optimizing and monitoring pump-and-treat (P&T) systems to meet target cleanup timelines. Flow patterns driven by hydraulic gradients and variations in permeability are described to provide insight into contaminant mass removal from long-screened wells. The objective of this multi-phase work is to provide actionable recommendations for improving remedy performance monitoring and P&T operations, which ongoing evaluations will address. This report summarizes the preliminary results of vertical flow and contaminant distribution monitoring in new extraction wells at the Hanford Site.

54 ENVIRONMENTAL SCIENCES↗

Unveiling the Occupational Exposure to Microbial Contamination in Conservation–Restoration Settings

Assuring a proper environment for the fulfillment of professional activities is one of the Sustainable Development Goals and is contemplated in the One Health approach assumed by the World Health Organization. This particular study is applied to an often neglected sector of our society—the conservators/restorers—despite the many health issues reported by these professionals. Three different specialties (textiles, paintings and wood sculpture) and locations were selected for evaluation by placement of electrostatic dust cloths. After treatment of the samples, bacterial and fungal contamination were assessed, as well as mycotoxin determination, the presence of azole-resistant strains and cytotoxicity of the microorganisms encountered. Bacteria were only present in one of medias used and showed relatively low numbers. The highest level of contamination by fungi was identified in one of the textiles settings. The textile area also showed the highest variability for fungi. Aspergillus sp. are one indicator of possible environmental issues, and A. sections Fumigati and Circumdati were particularly relevant in two of the settings and identified in all of them. No mycotoxins were detected and the large majority of the fungi identified were non-cytotoxic. Overall, these can be considered low-contaminated environments but attention should be given to the Aspergillus sp. contamination. Additional studies are needed not only to make these results more robust, but also to test if the environmental sampling alone is the best approach in a setting where there is very little movement and dust displacement and where professionals are in very close proximity to the artefacts being treated, which may suggest the existence of a micro-atmosphere worth evaluating and comparing to the obtained results.

Viegas, Carla (ORCID:0000000215456479)↗

Designing Unmanned Aerial Survey Monitoring Program to Assess Floating Litter Contamination

Monitoring marine contamination by floating litter can be particularly challenging since debris are continuously moving over a large spatial extent pushed by currents, waves, and winds. Floating litter contamination have mostly relied on opportunistic surveys from vessels, modeling and, more recently, remote sensing with spectral analysis. This study explores how a low-cost commercial unmanned aircraft system equipped with a high-resolution RGB camera can be used as an alternative to conduct floating litter surveys in coastal waters or from vessels. The study compares different processing and analytical strategies and discusses operational constraints. Collected UAS images were analyzed using three different approaches: (i) manual counting (MC), using visual inspection and image annotation with object counts as a baseline; (ii) pixel-based detection, an automated color analysis process to assess overall contamination; and (iii) machine learning (ML), automated object detection and identification using state-of-the-art convolutional neural network (CNNs). Our findings illustrate that MC still remains the most precise method for classifying different floating objects. ML still has a heterogeneous performance in correctly identifying different classes of floating litter; however, it demonstrates promising results in detecting floating items, which can be leveraged to scale up monitoring efforts and be used in automated analysis of large sets of imagery to assess relative floating litter contamination.

Almeida, Sílvia (ORCID:0000000320636826)↗

One Health Approach to Tackle Microbial Contamination on Poultries—A Systematic Review

This study reports the search of available data published regarding microbial occupational exposure assessment in poultries, following the PRISMA methodology. Air collection through filtration was the most frequently used. The most commonly used passive sampling method was material collection such as dust, cages, soils, sediment, and wastewater. Regarding assays applied, the majority of studies comprised culture-based methods, but molecular tools were also frequently used. Screening for antimicrobial susceptibility was performed only for bacteria; cytotoxicity, virological and serological assays were also performed. Most of the selected studies focused on bacteria, although fungi, endotoxins, and β-glucans were also assessed. The only study concerning fungi and mycotoxins reported the carcinogenic mycotoxin AFB1. This study gives a comprehensive overview of microbial contamination in the poultry industry, emphasizing this setting as a potential reservoir of microbial pathogens threatening human, animal, and environmental health. Additionally, this research helps to provide a sampling and analysis protocol proposal to evaluate the microbiological contamination in these facilities. Few articles were found reporting fungal contamination in poultry farms worldwide. In addition, information concerning fungal resistance profile and mycotoxin contamination remain scarce. Overall, a One Health approach should be incorporated in exposure assessments and the knowledge gaps identified in this paper should be addressed in further research.

Gomes, Bianca (ORCID:0000000262646072)↗

A data-driven method to estimate contamination from light ion beam transmutation at colliders

Collisions of relativistic light ions such as oxygen, neon, and magnesium, have been proposed as a way to examine the system-size dependence of dynamics typically associated with the quark-gluon plasma produced in collisions of heavier ions such as xenon, gold, or lead. Recent efforts at both the Relativistic Heavy Ion Collider (RHIC) and Large Hadron Collider (LHC) have produced large datasets of proton-oxygen, oxygen-oxygen, and neon-neon collisions, catalyzing intense interest in experimental backgrounds associated with light ion collisions. In particular, electromagnetic dissociation of light ions while they are circulating in a collider can result in beam contamination that is difficult to simulate precisely. Here we propose a data-driven method for evaluating the potential impact of beam contaminants on physics analyses. The method exploits the time-dependence and smaller size of contaminant ion species to define control regions that can be used to quantify potential contamination effects. A simple mode

Accelerator Physics (physics.acc-ph)↗

Potential Advantages to Employing an Onsite Laboratory at FUSRAP Sites Contaminated with Radionuclides and Metals - 20353

Various factors that support an evaluation of the relative costs, advantages and disadvantages of utilizing an onsite laboratory or an offsite laboratory for remediation of Formerly Utilized Sites Remedial Action Program (FUSRAP) sites contaminated with radionuclides and metals are presented. In terms of how much more quickly an onsite laboratory provides results versus an offsite laboratory, the results of this study provide tools for calculating the amount of cost savings per day for excavation of contaminated soils for various scenarios including: - State, municipal or local property remediation where the remediation schedule becomes time-critical due to the extra cost and inconvenience to the town or municipality caused by the need for increased security and safety personnel, possible road closures and detours, and the inconvenience to the public due to modified or decreased services of State or municipal facilities; - Residential property where the remediation schedule becomes time-critical due to the inconvenience to the homeowner as well as the importance of maintaining good community relations; - Commercial property where the remediation schedule becomes time-critical due to the hardship and potential loss of revenue endured by the property owner; - Open area where treatment of excavation water is required, and - Open area where treatment of excavation water is not required. For every scenario, the number of matrices, radionuclide and metal contaminants of concern and the project duration are important factors. The costs for the onsite laboratory included the capital costs associated with setting up the lab such as trailer(s) or building(s), power and water hookup, analytical testing equipment, balances, computers, desks and bookcases; support equipment such as hot plates, filtration assemblies, safety equipment, ovens, etc.; and supplies such as glassware, pipettes, filters, etc. and ongoing costs such as labor, chemicals and reagents, standards, cost of the laboratory obtaining certification and maintenance. Offsite laboratory sample testing costs are generally very competitive and typically substantially lower than onsite laboratory costs if only the sample testing costs are considered. The great disadvantage of using an offsite laboratory is that they often cannot guarantee rapid turnaround times for results which creates project delays associated with the remediation process including delays determining the completeness of the characterization and remediation processes, delays in backfilling a property and additional costs for treating wastewater (excavation water, stormwater or both). These costs will vary greatly depending upon the area of the country in which the project is located due to the wide range of labor costs for the onsite laboratory and field workers, as well as the contaminants of interest, matrices and most importantly the size of the impacted area and the number of properties located in that area. This paper provides guidelines for calculating the cost savings that may be realized if an onsite laboratory can generate results more quickly than an offsite laboratory by estimating the costs associated with the remediation process for the various scenarios noted above such as work crew labor costs, excavator and dump truck equipment rentals, wastewater treatment costs (if applicable) and the additional costs incurred by homeowners, commercial property owners and towns/municipalities that are reimbursed by the potentially responsible parties. Key assumptions involve the typical quickest turnaround time provided by the onsite and offsite laboratories. Costs for the operation of a wastewater treatment system and the remediation of a site area or property were provided by personnel who have been involved in the operation of a large FUSRAP site in New Jersey for many years. This study provides valuable information for determining the most cost-effective approach for analysis of project samples and therefore may be used on upcoming FUSRAP projects. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Iron Contamination and Polysilicon Gettering on the Performance of Polysilicon‐Based Passivating Contact Solar Cells

Over the past decade, silicon solar cells with carrier-selective passivating contacts based on polysilicon capping an ultra-thin silicon oxide (commonly known as TOPCon or POLO) have demonstrated promising efficiency potentials and are regarded as an evolutionary upgrade to the PERC (passivated emitter and rear contact) cells in manufacturing. The polysilicon-based passivating contacts also exhibit excellent gettering effects that relax the wafer and cleanroom requirements to some extent. Here, in this work, we experimentally explore the impact of bulk iron contamination and polysilicon gettering on the passivation quality of the polysilicon/oxide structure and the resulting solar cells performance. Results show that both n- and p-type polysilicon/oxide passivating contacts are not affected by iron gettering, demonstrating robust and stable passivation quality. However, for a very high bulk iron contamination (1 × 10 13 cm −3 ), the accumulated iron in the p-type lightly boron-doped emitter in crystalline silicon would degrade the emitter saturation current density. This can cause a reduction in both open-circuit voltage and short-circuit current. Meanwhile, this very high iron content (1 × 10 13 cm −3 ) can further degrade the fill factor and temperature coefficient of the cells. On the other hand, for an initial iron content of 2 × 10 12 cm −3 , which should be well above the iron level in the current industrial Czochralski silicon wafers, the resulting cells demonstrate similar performance as the control group with no intentional iron contamination. This work brings attention to both the benefits of polysilicon gettering effects as well as the potential degradation due to the accumulation of metal impurities in the p-type emitter region.

14 SOLAR ENERGY↗