Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contaminated data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Chromium Plume at LANL - From Conceptual Site Model to Development of Complex Remediation Strategies - 18682

A hexavalent chromium plume is present in deep groundwater beneath Los Alamos National Laboratory (LANL or the Laboratory). The plume originated from releases of potassium dichromate from cooling towers from 1956 - 1972. Estimates are that up to 72,000 kg of chromium was released during that period. Data from surface water-balance studies, core-hole and groundwater characterization, geomorphic investigations and geology and geophysics provide the basis for an evolved conceptual model that chromium initially traveled rapidly via an effluent-supported stream for several kilometers, then infiltrated through a stratigraphically complex 275-300 meters thick vadose zone and eventually into a deep (regional) aquifer that is the water supply for the Laboratory and surrounding municipality. The travel time from the release point to the regional aquifer is estimated at 5-10 years based on modeling and contaminant tracers. Monitoring data from two-screen wells and piezometers within the regional aquifer, and data derived from stratified sampling conducted during sonic coring and from analysis of sonic core indicate that the chromium contamination occurs within the upper 23 meters of the highly stratified regional aquifer. Different geologic units at the water table and structural dip of depositional bedding appear to have little effect on chromium migration and plume shape and thickness which instead appear to be a manifestation of multiple breakthrough locations, interconnectedness of preferential hydraulic strata, and a negligible vertical gradient. Recent monitoring data indicate that the down-gradient plume edge (as defined by the New Mexico groundwater standard of 50 μg/L) may be advancing near the Laboratory's boundary with a neighboring Indian reservation. The Laboratory is addressing the increasing concentrations with a regulatory-driven interim measure that uses hydraulic control to manage plume migration. The interim measure involves limited-duration (2-3 years) pumping, treatment, and injection to rapidly establish and maintain the 50 μg/L plume edge within the Laboratory boundary while a final remediation strategy is developed and approved by the State regulator. A final remediation strategy will depend heavily on the ability to cost-effectively access the deep aquifer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multivariate Empirical Mode Decomposition Based Signal Analysis and Efficient-Storage in Smart Grid

Wide-area-measurement systems (WAMSs) are used in smart grid systems to enable the efficient monitoring of grid dynamics. However, the overwhelming amount of data and the severe contamination from noise often impede the effective and efficient data analysis and storage of WAMS generated measurements. To solve this problem, we propose a novel framework that takes advantage of Multivariate Empirical Mode Decomposition (MEMD), a fully data-driven approach to analyzing non-stationary signals, dubbed MEMD based Signal Analysis (MSA). The frequency measurements are considered as a linear superposition of different oscillatory components and noise. The low-frequency components, corresponding to the long-term trend and inter-area oscillations, are grouped and compressed by MSA using the mean shift clustering algorithm. Whereas, higher-frequency components, mostly noise and potentially part of high-frequency inter-area oscillations, are analyzed using Hilbert spectral analysis and they are delineated by statistical behavior. By conducting experiments on both synthetic and real-world data, we show that the proposed framework can capture the characteristics, such as trends and inter-area oscillation, while reducing the data storage requirements

Big Data↗

Specifications and a Prototype Software to Demonstrate a Data Catalog for Hanford Datasets

Environmental management activities at the Hanford Site produce extensive data about site conditions, contaminants, and cleanup activities. Managing, archiving, and accessing that data requires a high degree of collaboration among site contractors and a high level of awareness by project managers and staff. The Hanford Site has a range of databases (e.g., Hanford Environmental Information System [HEIS]) and their associated user interfaces (e.g., Environmental Dashboard Application [EDA], Virtual Library [VL]), as well as other document management systems (e.g., Integrated Document Management System [IDMS]). However, Hanford lacks a single unified resource to find data (which itself comes in multiple formats) amongst the multiple disparate systems, not to mention ad hoc data not contained in an official repository/database.

54 ENVIRONMENTAL SCIENCES↗

Contaminant Leach Testing of Hanford Tank 241-C-104 Residual Waste

Leach testing of Tank C-104 residual waste was completed using batch and column experiments. Tank C-104 residual waste contains exceptionally high concentrations of uranium (i.e., as high as 115 mg/g or 11.5 wt.%). This study was conducted to provide data to develop contaminant release models for Tank C-104 residual waste and Tank C-104 residual waste that has been treated with lime to transform uranium in the waste to a highly insoluble calcium uranate (CaUO4) or similar phase. Three column leaching cases were investigated. In the first case, C-104 residual waste was leached with deionized water. In the second case, crushed grout was added to the column so that deionized water contacted the grout prior to contacting the waste. In the third case, lime was mixed in with the grout. Results of the column experiments demonstrate that addition of lime dramatically reduces the leachability of uranium from Tank C-104 residual waste. Initial indications suggest that CaUO4 or a similar highly insoluble calcium rich uranium phase forms as a result of the lime addition. Additional work is needed to definitively identify the uranium phases that occur in the as received waste and the waste after the lime treatment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Catalog of Temporally Localized Systematic Deviations in Global Body Wave Travel-Time Measurements

Accurate measurements of the arrival times of seismic waves are crucial for seismological analyses such as robust locations of earthquakes, characterization of seismic sources, and high-fidelity imaging of the Earth’s interior. However, these travel-time measurements can sometimes be contaminated by timing errors at the stations which record this data. In this study, we apply a classical approach, based on identifying time-dependence in measured body wave arrival times, to identify these timing errors in a dataset on the order of 107 individual measurements. We find timing deviations at a subset of the stations in our dataset and document the temporal location, extent, and severity of these errors, finding errors at 83 stations, and impacting ~100,000 measurements. This catalog of deviations may enable future investigators to obtain a more accurate dataset through the implementation of quality control measures to eliminate the contaminated data we have identified.

58 GEOSCIENCES↗

Frequency domain analysis of errors in cross-correlations of ambient seismic noise

We analyse random errors (variances) in cross-correlations of ambient seismic noise in the frequency domain, which differ from previous time domain methods. Extending previous theoretical results on ensemble averaged cross-spectrum, we estimate confidence interval of stacked cross-spectrum of finite amount of data at each frequency using non-overlapping windows with fixed length. The extended theory also connects amplitude and phase variances with the variance of each complex spectrum value. Analysis of synthetic stationary ambient noise is used to estimate the confidence interval of stacked cross-spectrum obtained with different length of noise data corresponding to different number of evenly spaced windows of the same duration. This method allows estimating Signal/Noise Ratio (SNR) of noise cross-correlation in the frequency domain, without specifying filter bandwidth or signal/noise windows that are needed for time domain SNR estimations. Based on synthetic ambient noise data, we also compare the probability distributions, causal part amplitude and SNR of stacked cross-spectrum function using one-bit normalization or pre-whitening with those obtained without these pre-processing steps. Natural continuous noise records contain both ambient noise and small earthquakes that are inseparable from the noise with the existing pre-processing steps. Using probability distributions of random cross-spectrum values based on the theoretical results provides an effective way to exclude such small earthquakes, and additional data segments (outliers) contaminated by signals of different statistics (e.g. rain, cultural noise), from continuous noise waveforms. This technique is applied to constrain values and uncertainties of amplitude and phase velocity of stacked noise cross-spectrum at different frequencies, using data from southern California at both regional scale (~35 km) and dense linear array (~20 m) across the plate-boundary faults. A block bootstrap resampling method is used to account for temporal correlation of noise cross-spectrum at low frequencies (0.05–0.2 Hz) near the ocean microseismic peaks.

58 GEOSCIENCES↗

Modelling the impact of quasar redshift errors on the full-shape analysis of correlations in the Lyman-α forest.

In preparation for the first cosmological measurements from the full shape of the Lyman-α (Lyα) forest from DESI, we must carefully model all relevant systematics that might bias our analysis. It was shown in Youles et al. (2022) that random quasar redshift errors produce a smoothing effect on the mean quasar continuum in the Lyα forest region. This, in turn, gives rise to spurious features in the Lyα autocorrelation and its cross-correlation with quasars. Using synthetic data sets based on the DESI survey, we confirm that the impact on BAO measurements is small, but that a bias is introduced to parameters which depend on the full shape of our correlations. We combine a model of this contamination in the cross-correlation (Youles et al. 2022) with a new model we introduce here for the auto-correlation. These are parametrised by 3 parameters, which, when included in a joint fit to both correlation functions, successfully eliminate any impact of redshift errors on our full-shape constraints. We also present a strategy for removing this contamination from real data, by removing ∼0.3% of correlating pairs.

cosmology↗

Monitoring and flaw detection during wire-based directed energy deposition using in-situ acoustic sensing and wavelet graph signal analysis

The goal of this work is to detect flaw formation in the wire-based directed energy deposition (W-DED) process using in-situ sensor data. The W-DED studied in this work is analogous to metal inert gas electric arc welding. The adoption of W-DED in industry is limited because the process is susceptible to stochastic and environmental disturbances that cause instabilities in the electric arc, eventually leading to flaw formation, such as porosity and suboptimal geometric integrity. Moreover, due to the large size of W-DED parts, it is difficult to detect flaws post-process using non-destructive techniques, such as X-ray computed tomography. Accordingly, the objective of this work is to detect flaw formation in W-DED parts using data acquired from an acoustic (sound) sensor installed near the electric arc. To realize this objective, we develop and apply a novel wavelet integrated graph theory approach. The approach extracts a single feature called graph Laplacian Fiedler number from the noise-contaminated acoustic sensor data, which is subsequently tracked in a statistical control chart. Using this approach, the onset of various types of flaws are detected with a false alarm rate less-than 2%. This work demonstrates the potential of using advanced data analytics for in-situ monitoring of W-DED.

42 ENGINEERING↗

Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers

There is a concern that environmental-contamination caused corrosion may negatively affect Information Technology (IT) equipment reliability. Nineteen data centers in the United States and two in India were evaluated using Corrosion Classification Coupons (CCC) to assess environmental air quality as it may relate IT equipment reliability. The data centers were of two basic types: closed and outside-air cooled. A closed data center provides cool air to the IT equipment using air conditioning in which only a small percent age of the recirculation air is make-up air continuously supplied from outside to meet human health requirements. An outside-air cooled data center uses outside air directly as the primary source for IT equipment cooling. Corrosion measuring coupons containing copper and silver metal strips were placed in both closed and outside-air cooled data centers. The coupons were placed at each data center (closed and outside-air cooled types) with the location categorized into three groups: (1) Outside - coupons sheltered, located near or at the supply air inlet, but located before any filtering, (2) Supply - starting just after initial air filtering continuing inside the plenums and ducts feeding the data center rooms, and (3) Inside located inside the data center rooms near the IT equipment. Each coupon was exposed for thirty days and then sent to a laboratory for a corrosion rate measurement analysis. The goal of this research was to investigate whether gaseous contamination is a concern for U.S. data center operators as it relates to the reliability of IT equipment. More specifically, should there be an increased concern if outside air for IT equipment cooling is used To begin to answer this question limited exploratory measurements of corrosion rates in operating data centers in various locations were undertaken. This study sought to answer the following questions: (1) What is the precision of the measurements (2) What are the approximate statistical distributions of copper and silver corrosion rates in the sampled data centers(3) To what extent are copper and silver corrosion measurements related (4) What is the relationship of corrosion rate measurements between outside-air cooled data centers compared to closed data centers (5) How do corrosivity measurements relate to IT equipment failure rates The data from our limited sample size suggests that most United States data center operators should not be concerned with environmental gaseous contamination causing high IT equipment failure rates even when using outside-air cooling. The research team recommends additional basic research on how environmental conditions, specifically gaseous contamination, affect electronic equipment reliability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2019

Desert Research Institute (DRI) conducted a field assessment of the potential for contaminated soil to be transported from the Smoky Site Contamination Area (CA) because of storm runoff. This activity supported U.S. Department of Energy (DOE) Environmental Management Nevada Program (EM NV) efforts to establish post-closure monitoring plans for the Smoky Site Soils Corrective Action Unit (CAU) 550. The work was intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause the movement of contaminated soils, as well as determine the particle size fraction most closely associated with transported radionuclide-contaminated soils. These data will facilitate the design of the appropriate post-closure monitoring program. In 2011, DRI installed a meteorological monitoring station on the west side of the Smoky Site CA and a hydrologic (runoff) monitoring station within the CA, near the east side. The meteorological station collected air temperature, wind speed, wind direction, relative humidity, precipitation, solar radiation, barometric pressure, soil temperature, and soil water content data. The maximum, minimum, and average or total values (as appropriate) for each of these parameters were recorded for each 10-minute interval. The maximum, minimum, and average water depth in the flume installed at the hydrologic station were also recorded for each 10-minute interval. This report presents the data collected from these stations during fiscal year (FY) 2019. During the FY2019 reporting period, the warmest months were June, July, and August and the coldest were December and February. The highest monthly solar radiation (i.e., sunshine) values were recorded in June, July, and August, whereas December through February had the lowest solar radiation values. Monthly mean wind speeds were highest in the spring (April) and early summer (June). Winds were predominantly from the north, except in February, July, August, and September when winds were mostly from the west. The monthly average relative humidity ranged from 17 percent to approximately 60 percent. Humidity was lowest in the summer and highest in the winter. Monthly total precipitation ranged from 0.0 during August and September to 2.22 inches (in) (56.39 millimeters [mm]) in February. Total precipitation for FY2019 was 7.83 in (198.88 mm). During the reporting period, a single, nonzero, flow event was recorded at the flume. This occurred over two days between March 6 and 7, 2019, in response to 1.16 in (29.46 mm) of precipitation falling within 9.3 hours on March 6, 2019. This event produced a peak water depth of 0.39 in (0.99 centimeters [cm]) in the flume, and runoff was measured for approximately 23.5 hours. However, the maximum recorded flow depth was less than the limit for flow discharge and velocity that can be calculated for the six-inch (15 cm) throat of a Parshall flume. The runoff event produced insufficient flow velocities through the natural channel to cause local erosion and transport of bedload materials. No bedload samples were collected for radiological analysis. Observing meteorological and environmental conditions that lead to storm runoff will help identify the parameters and threshold conditions that should be incorporated into post-closure monitoring plans for this and similar Soils CAU sites. Routine monitoring of meteorological and hydrologic parameters at the Smoky Site CA has been discontinued at the request of EM NV, effective at the conclusion of FY2019. Environmental data acquisition was completed and the meteorological and runoff monitoring stations were removed from the Smoky Site on October 15, 2019.

54 ENVIRONMENTAL SCIENCES↗

Automated identification of local contamination in remote atmospheric composition time series

Abstract. Atmospheric observations in remote locations offer a possibility of exploring trace gas and particle concentrations in pristine environments. However, data from remote areas are often contaminated by pollution from local sources. Detecting this contamination is thus a central and frequently encountered issue. Consequently, many different methods exist today to identify local contamination in atmospheric composition measurement time series, but no single method has been widely accepted. In this study, we present a new method to identify primary pollution in remote atmospheric datasets, e.g., from ship campaigns or stations with a low background signal compared to the contaminated signal. The pollution detection algorithm (PDA) identifies and flags periods of polluted data in five steps. The first and most important step identifies polluted periods based on the derivative (time derivative) of a concentration over time. If this derivative exceeds a given threshold, data are flagged as polluted. Further pollution identification steps are a simple concentration threshold filter, a neighboring points filter (optional), a median, and a sparse data filter (optional). The PDA only relies on the target dataset itself and is independent of ancillary datasets such as meteorological variables. All parameters of each step are adjustable so that the PDA can be “tuned” to be more or less stringent (e.g., flag more or fewer data points as contaminated). The PDA was developed and tested with a particle number concentration dataset collected during the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition in the central Arctic. Using strict settings, we identified 62 % of the data as influenced by local contamination. Using a second independent particle number concentration dataset also collected during MOSAiC, we evaluated the performance of the PDA against the same dataset cleaned by visual inspection. The two methods agreed in 94 % of the cases. Additionally, the PDA was successfully applied to a trace gas dataset (CO2), also collected during MOSAiC, and to another particle number concentration dataset, collected at the high-altitude background station Jungfraujoch, Switzerland. Thus, the PDA proves to be a useful and flexible tool to identify periods affected by local contamination in atmospheric composition datasets without the need for ancillary measurements. It is best applied to data representing primary pollution. The user-friendly and open-access code enables reproducible application to a wide suite of different datasets. It is available at https://doi.org/10.5281/zenodo.5761101 (Beck et al., 2021).

54 ENVIRONMENTAL SCIENCES↗

Mathematical Morphological Filtering with a Self-Adaptive Reconstruction Technique and Application to Local Seismic Data

Recorded seismic data are generally contaminated by noise from different sources, which masks the signals of interest. In the seismology community, frequency filtering (FF) is the standard method for noise suppression. However, when the signal of interest and noise share the same frequency band, the latter cannot be filtered out without infringing on the former. We implemented a noise suppression approach based on the mathematical morphology theorem. The method involves compound operations of dilation and erosion using structuring elements of varying lengths and decomposes an input noisy waveform into several time functions with differing characteristics. Further, the filtered waveform is constructed from the time functions using a self-adaptive reconstruction technique. Application to a data set of >4700 local waveforms suggests that the implemented mathematical morphological filtering (MMF) approach is efficient for data with low signal-to-noise ratio (SNR) and significantly outperforms FF in that SNR range. For most of the dataset, FF, machine learning (ML) denoising, and continuous wavelet transform (CWT) thresholding result in higher SNR values compared with the MMF method. However, for ~42% of the waveforms, MMF outperforms FF, and the SNR gain achieved with MMF is as large as ~23 dB. Compared to ML denoising and CWT thresholding, this proportion drops to only ~10%–14%. Our results suggests that in an operational setting, MMF cannot replace the other noise suppression methods; however, signal detection can be improved if MMF is used to supplement them in some scenarios. MMF could help detect signals in problematic low-SNR data, which are currently being missed particularly when using FF alone.

58 GEOSCIENCES↗

ATLAS muon data quality with 2010 LHC

ATLAS is a large multipurpose detector, presently in the full operational phase at LHC, the CERN Large Hadron Collider accelerator. The ATLAS Muon Spectrometer has been designed to provide standalone measurement of the muon momentum up to a few TeV with a relative precision better that 10% and to trigger on single muons with transverse momentum down to a few GeV, and an efficiency close to 100%, taking into account the high level background environment, the inhomogeneous magnetic field, and the large size of the apparatus (24 m diameter by 44 m length). ATLAS MS detector has being commissioned using all types of physics data available: cosmic rays and events produced during a few days of LHC single beam operations. This first year of data taking has been of great interest, not only for the physics outcome, but also for operating the system under the environment it was designed for. This paper is describing the design, the implementation as well as the data quality performance achieved during this first year of data taking. We also describe how to reduce the cosmic background contamination in early collisions data. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First season MWA EoR power spectrum results at redshift 7

The Murchison Widefield Array (MWA) has collected hundreds of hours of Epoch of Reionization (EoR) data and now faces the challenge of overcoming foreground and systematic contamination to reduce the data to a cosmological measurement. We introduce several novel analysis techniques, such as cable reflection calibration, hyper-resolution gridding kernels, diffuse foreground model subtraction, and quality control methods. Each change to the analysis pipeline is tested against a two-dimensional power spectrum figure of merit to demonstrate improvement. We incorporate the new techniques into a deep integration of 32 hours of MWA data. This data set is used to place a systematic-limited upper limit on the cosmological power spectrum of Δ{sup 2}⩽2.7×10{sup 4} mK{sup 2} at k = 0.27 h Mpc{sup −1} and z = 7.1, consistent with other published limits, and a modest improvement (factor of 1.4) over previous MWA results. From this deep analysis, we have identified a list of improvements to be made to our EoR data analysis strategies. These improvements will be implemented in the future and detailed in upcoming publications.

79 ASTRONOMY AND ASTROPHYSICS↗

Bicep2. III. INSTRUMENTAL SYSTEMATICS

In a companion paper, we have reported a >5σ detection of degree scale B-mode polarization at 150 GHz by the Bicep2 experiment. Here we provide a detailed study of potential instrumental systematic contamination to that measurement. We focus extensively on spurious polarization that can potentially arise from beam imperfections. We present a heuristic classification of beam imperfections according to their symmetries and uniformities, and discuss how resulting contamination adds or cancels in maps that combine observations made at multiple orientations of the telescope about its boresight axis. We introduce a technique, which we call “deprojection,” for filtering the leading order beam-induced contamination from time-ordered data, and show that it reduces power in Bicep2's actual and null-test BB spectra consistent with predictions using high signal-to-noise beam shape measurements. We detail the simulation pipeline that we use to directly simulate instrumental systematics and the calibration data used as input to that pipeline. Finally, we present the constraints on BB contamination from individual sources of potential systematics. We find that systematics contribute BB power that is a factor of ∼10× below Bicep2's three-year statistical uncertainty, and negligible compared to the observed BB signal. The contribution to the best-fit tensor/scalar ratio is at a level equivalent to r = (3–6) × 10{sup −3}.

79 ASTRONOMY AND ASTROPHYSICS↗

THE UNIVERSAL INITIAL MASS FUNCTION IN THE EXTENDED ULTRAVIOLET DISK OF M83

We report deep Subaru H{alpha} observations of the extended ultraviolet (XUV) disk of M83. These new observations enable the first complete census of very young stellar clusters over the entire XUV disk. Combining Subaru and Galaxy Evolution Explorer data with a stellar population synthesis model, we find that (1) the standard, but stochastically sampled, initial mass function (IMF) is preferred over the truncated IMF because there are low-mass stellar clusters (10{sup 2-3} M{sub Sun }) that host massive O-type stars; (2) the standard Salpeter IMF and a simple aging effect explain the counts of far-UV (FUV)-bright and H{alpha}-bright clusters with masses >10{sup 3} M{sub Sun }; and (3) the H{alpha}-to-FUV flux ratio over the XUV disk supports the standard IMF. To reach conclusion (2), we assumed instantaneous cluster formation and a constant cluster formation rate over the XUV disk. The Subaru Prime Focus Camera covers a large area even outside the XUV disk-far beyond the detection limit of the H I gas. This enables us to statistically separate the stellar clusters in the disk from background contamination. The new data, model, and previous spectroscopic studies provide overall consistent results with respect to the internal dust extinction (A{sub V} {approx} 0.1 mag) and low metallicity ({approx}0.2 Z{sub Sun }) using the dust extinction curve of the Small Magellanic Cloud. The minimum cluster mass for avoiding the upper IMF incompleteness due to stochastic sampling and the spectral energy distributions of O, B, and A stars are discussed in the Appendices.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep Learning Denoising Applied to Regional Distance Seismic Data in Utah

Seismic waveform data are generally contaminated by noise from various sources. Suppressing this noise effectively so that the remaining signal of interest can be successfully exploited remains a fundamental problem for the seismological community. To date, the most common noise suppression methods have been based on frequency filtering. These methods, however, are less effective when the signal of interest and noise share similar frequency bands. Inspired by source separation studies in the field of music information retrieval (Jansson et al., 2017) and a recent study in seismology (Zhu et al., 2019), we implemented a seismic denoising method that uses a trained deep convolutional neural network (CNN) model to decompose an input waveform into a signal of interest and noise. In our approach, the CNN provides a signal mask and a noise mask for an input signal. The short-time Fourier transform (STFT) of the estimated signal is obtained by multiplying the signal mask with the STFT of the input signal. To build and test the denoiser, we used carefully compiled signal and noise datasets of seismograms recorded by the University of Utah Seismograph Stations network. Results of test runs involving more than 9000 constructed waveforms suggest that on average the denoiser improves the signal-to-noise ratios (SNRs) by ~5 db, and that most of the recovered signal waveforms have high similarity with respect to the target waveforms (average correlation coefficient of ~0.80) and suffer little distortion. Application to real data suggests that our denoiser achieves on average a factor of up to ~2-5 improvement in SNR over band-pass filtering and can suppress many types of noise that band-pass filtering cannot. For individual waveforms, the improvement can be as high as ~15 db.

58 GEOSCIENCES↗

Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2018

Desert Research Institute (DRI) is conducting a field assessment of the potential for contaminated soil to be transported from the Smoky Site Contamination Area (CA) as a result of storm runoff. This activity supports U.S. Department of Energy (DOE) Environmental Management Nevada Program (EM NV) efforts to establish post-closure monitoring plans for the Smoky Site Soils Corrective Action Unit (CAU) 550. The work is intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause the movement of contaminated soils, as well as determine the particle size fraction that is most closely associated with transported radionuclide-contaminated soils. These data will facilitate the design of the appropriate post-closure monitoring program. In 2011, DRI installed a meteorological monitoring station on the west side of the Smoky Site CA and a hydrologic (runoff) monitoring station within the CA, near the east side. The meteorological station collects air temperature, wind speed, wind direction, relative humidity, precipitation, solar radiation, barometric pressure, soil temperature, and soil water content data. The maximum, minimum, and average or total values (as appropriate) for each of these parameters are recorded for each 10-minute interval. The maximum, minimum, and average water depth in the flume installed at the hydrologic station are also recorded for each 10-minute interval. This report presents the data collected from these stations during fiscal year (FY) 2018. During the FY2018 reporting period, the warmest months were June, July, and August and the coldest were December through March. Solar radiation showed the same seasonal trend. Monthly mean wind speeds were highest in the spring (March through May) and early summer (June). Winds were generally from the west during the summer and from the north throughout the fall and winter. The monthly average relative humidity ranged from the mid-teens to approximately 50 percent. Humidity was lowest in the fall and highest in the winter. Monthly total precipitation ranged from 0 in October, December, and June to approximately 1.38 inches (in) (35.05 millimeters [mm]) in July. Total precipitation for FY2018 was 3.86 in (98.04 mm). During the reporting period, two runoff events were recorded at the flume. One occurred on July 14, 2018, in response to precipitation earlier the same day. This event produced a peak water depth of 11.26 in (28.60 centimeters [cm]) in the flume, which is equivalent to a discharge of 1.86 cubic feet per second (cfs) (0.05 cubic meters per second [cm/s]) and a velocity of 3.97 feet per second (fps) (1.21 meters per second [m/s]) through the flume. Applying the flume hydraulic measurements to the channel geometry at the nearest surveyed cross-section it was determined that the velocity through the channel was 1.29 fps (0.39 m/s), which is sufficient to transport silts and fine sands. The second flow event occurred in response to earlier precipitation on September 4, 2018. This event produced a peak water depth of 0.78 in (1.98 cm) in the flume, which is equivalent to a discharge of 0.03 cfs (0.001 cm/s) and a velocity of 1.17 fps (0.36 m/s) through the flume. Applying the flume hydraulic measurements to the channel geometry at the nearest surveyed cross-section it was determined that the velocity through the channel was 0.03 fps (0.01 m/s). Although neither runoff event produced sufficient flow velocities through the natural channel to cause local erosion and transport of coarser bedload materials, the velocity of the first runoff event was sufficient to transport silts and fine sands, which have been shown to be preferentially associated with radionuclide contaminants. Therefore, a sampling event was planned after the first flow event in conjunction with a periodic maintenance inspection. As no suspended load sampling is available at this location, bedload samples were collected from the vicinity of the flume on August 7, 2018. The collected sediment was separated into three particle size fractions and each fraction was analyzed for americium-241 (Am-241), plutonium-238 (Pu-238), and plutonium-239/240 (Pu-239/240) by alpha spectrometry. The two smaller particle size fractions had higher concentrations of all three radionuclides than the largest particle size fraction. Additionally, Pu-239/240 had the highest concentration and Pu-238 had the lowest concentration in all samples. The same relationship between the concentrations of Pu-238 and Pu-239/240 was seen in samples reported in FY2013 and FY2014. Observation of meteorological and environmental conditions that lead to storm runoff will help identify parameters and threshold conditions that should be incorporated into postclosure monitoring plans for this and similar sites as well as aid in determining appropriate closure strategies for other Soils CAUs.

54 ENVIRONMENTAL SCIENCES↗