Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Urban SAFE50: Modeling, Controlling, and Testing Safe UAS Operations in Low Altitude Settings

The research and development of UAVs (Unmanned Aerial Vehicles) are quickly progressing as industries and hobbyist societies recognize their utility. NASA is focused on the technology development and safety considerations surrounding commercial use of UAVs. Urban SAFE50 (Safe Autonomous Flight Environment within the notional last 50 feet of operation of 55 pound class UAS (Small Unmanned Aircraft Systems)) is focused on the necessary real-­time decision algorithms and flight models prevalent in low-­altitude, high-­density city environments. Construction of on-­board controls to respond to motor failure and wind dynamics as well as a database of computational flight models and battery discharge profiles will help policymakers to predict and regulate unmanned aircraft flight safely and effectively.

SAFE↗

Development of an emulation-simulation thermal control model for space station application

An improved capability for comparing various techniques for thermal management in the Space Station was developed. Current planning for the orbiting space station calls for a dual keel configuration. The thermal control system (TCS) for the space is composed of a central TCS and internal thermal control systems for the modules, as well as service facilities and attached payloads. The internal TCS may be attacted to the central TCS through a thermal bus. The central TCS is composed of a main transport system which collects waste thermal energy from each of the modules and transports it through coolant lines to the main rejection system. The waste heat loads in the modules arise from electrical and electronic equipment as well as metabolic loads in the manned modules. Several candidate technologies are being considered for acquiring the waste heat loads, for transporting the thermal energy between the acquisition and rejection systems, and for rejecting the waste heat to space. The analysis techniques described were developed for use in evaluating reliability, weights, costs, volumes, and power requirements for configurations using different candidates and different mission parameters.

Hartley, James G.↗

Measurements, modeling, control and simulation - as applied to the human left ventricle for purposeful physiological monitoring.

Interdisciplinary engineering research effort in studying the intact human left ventricle has been employed to physiologically monitor the heart and to obtain its 'state-of-health' characteristics. The left ventricle was selected for this purpose because it plays a key role in supplying energy to the body cells. The techniques for measurement of the left ventricular geometry are described; the geometry is effectively displayed to bring out the abnormalities in cardiac function. Methods of mathematical modeling, which make it possible to determine the performance of the intact left ventricular muscle, are also described. Finally, features of a control system for the left ventricle for predicting the effect of certain physiological stress situations on the ventricle performance are discussed.

Ghista, D. N.↗

Development of an emulation-simulation thermal control model for space station application

The orbiting space station being developed by NASA will have many thermal sources and sinks as well as requirements for the transport of thermal energy through large distances. The station is also expected to evolve over twenty or more years from an initial design. As the station evolves, thermal management will become more difficult. Thus, analysis techniques to evaluate the effects of changing various thermal loads and the methods utilized to control temperature distributions in the station are essential. Analysis techniques, including a user-friendly computer program, were developed which should prove useful to thermal designers and system analysts working on the space station. The program uses a data base and user input to compute costs, sizes, and power requirements for individual components and complete systems. User input consists of selecting mission parameters, selecting thermal acquisition configurations, transport systems and distances, and thermal rejection configurations. The capabilities of the program may be expanded by including additional thermal models as subroutines.

Hartley, James G.↗

Preliminary Results of the 1.5% TCA (Modular) Controls Model in the NASA Langley UPWT

To summarize the significant highlights in this report: (1) Data quality, determined by multiple repeat runs performed on the TCA baseline configuration, and long-term repeatability, determined by comparing baseline Reference H data from this test to a previous test, have been shown to be good. (2) The longitudinal stability of the TCA is more non-linear than for the Reference H, and while it is similar at normal lift values, the TCA has considerably more pitch-up at higher lift. (3) Longitudinal control effectiveness of the TCA is similar to the Reference H and the ratio of elevator effectiveness to horizontal tail effectiveness is approximately 0.3. 4) The directional stability of the TCA is improved relative to Reference H at higher angles-of attack. The chine is effective for improving directional stability. (5) The directional control effectiveness 'of the TCA rudder is the same as that of the Reference H rudder at low angles-of-attack, after taking factors, such as number of rudder panels deflected and vertical tail volume into account. However, rudder effectiveness was shown to be reduced at higher angles-of-attack. (6) The lateral stability was shown to be reduced relative to the Reference H, which may be beneficial at low speeds for alleviating lateral control saturation. (7) Lateral control effectiveness for the TCA was shown to be similar to the Reference H for negative trailing-edge flap deflections and was reduced by approximately 25% for positive trailing-edge flap deflections.

Kubiatko, Paul↗

Preliminary Results of the 1.5% TCA (Modular) Controls Model in the NASA Langley UPWT

To summarize the significant highlights in this report: (1) Data quality, determined by multiple repeat runs performed on the TCA baseline configuration, and long-term repeatability, determined by comparing baseline Reference H data from this test to a previous test, have been shown to be good. (2) The longitudinal stability of the TCA is more non-linear than for the Reference H, and while it is similar at normal lift values, the TCA has considerably more pitch-up at higher lift. (3) Longitudinal control effectiveness of the TCA is similar to the Reference H and the ratio of elevator effectiveness to horizontal tail effectiveness is approximately 0.3. (4) The directional stability of the TCA is improved relative to Reference H at higher angles-of attack. The chine is effective for improving directional stability.

Kubiatko, Paul↗

Laboratory-developed contact models controlling instability on frictional faults: FORESHOCKS ON FRICTIONAL FAULTS

Laboratory experiments were performed on a polymethyl methacrylate (PMMA)-PMMA frictional interface in a direct shear apparatus in order to gain understanding of fault dynamics leading to gross rupture. Actual asperity sizes and locations along the interface were characterized using a pressure-sensitive film. Slow aseismic slip accumulated nonuniformly along the fault and showed dependency on the applied normal force-increased normal force resulted in higher slip gradients. The slow slip front propagated from the trailing (pushed) edge into a region of more densely distributed asperities at rates between 1 and 9.5 mm/s. Foreshocks were detected and displayed impulsive signals with source radii ranging between 0.21 and 1.09 mm; measurements made using the pressure-sensitive film were between 0.05 and 1.2 mm. The spatiotemporal clustering of foreshocks and their relation to the elastodynamic energy released was dependent on the normal force. In the region where foreshocks occurred, qualitative optical measurements of the asperities along the interface were used to visualize dynamic changes occurring during the slow slip phase. To better understand the nucleation process, a quasi-static asperity finite element (FE) model was developed and focused in the region where foreshocks clustered. The FE model consisted of 172 asperities, located and sized based on pressure-sensitive film measurements. The numerical model provides a plausible explanation as to why foreshocks cluster in space and observed a normal force dependency and lend credence to Ohnaka’s nucleation model.

58 GEOSCIENCES↗

An accurate polynomial-based analytical charge control model for AlGaN/GaN HEMT

A new nonlinear expression of Fermi-level variation with two-dimensional electron gas density in a high electron mobility has been proposed. It was found that our expression has a better fit with the numerical results. And, an analytical expression for n{sub s} in terms of the applied gate voltage is developed. Comparing with other previous approximations, the solutions of our expression has a better agreement with the exact numerical results over the entire range of interest. Besides, the solutions of our expression of n{sub s} versus V{sub G} are compared with the experimental data and shown to be in good agreement over a wide range of bias conditions.

36 MATERIALS SCIENCE↗

TEAMER - AquaHarmonics High Fidelity WEC Sim PTO and Control Model Validation, Sim Model

Collaborative effort between AquaHarmonics, Sandia National Laboratories (SNL), and the National Renewable Energy Laboratory (NREL) to revise and validate Aquaharmonics' full wave to wire model, allowing for reduced uncertainty and increased understanding of design requirements of a utility scale wave energy converter (WEC). SNL and NREL in collaboration with AquaHarmonics, will set up and run WEC Simulator (WEC-Sim) models of the AquaHarmonics WEC, building off past model developments for inclusion of custom PTO (power take-off) dynamics. The intent is to review, update, and verify or validate a new WEC-Sim model against wave tank experimental data. Furthermore, the WEC-Sim model will be coupled to an energy storage system model to better understand the wave-to-wire functionality. Project is part of the TEAMER (Testing & Expertise for Marine Energy) RFTS (request for technical support) system of WEC research projects. Testing data can be found in the associated MHKDR link below.

16 TIDAL AND WAVE POWER↗

TEAMER - AquaHarmonics High Fidelity WEC Sim PTO and Control Model Validation, Test Logs and Results

Collaborative effort between AquaHarmonics, Sandia National Laboratories (SNL), and the National Renewable Energy Laboratory (NREL) to revise and validate Aquaharmonics' full wave to wire model, allowing for reduced uncertainty and increased understanding of design requirements of a utility scale wave energy converter (WEC). SNL and NREL in collaboration with AquaHarmonics, will set up and run WEC Simulator (WEC-Sim) models of the AquaHarmonics WEC, building off past model developments for inclusion of custom PTO (power take-off) dynamics. The intent is to review, update, and verify or validate a new WEC-Sim model against wave tank experimental data. Furthermore, the WEC-Sim model will be coupled to an energy storage system model to better understand the wave-to-wire functionality. This data set is described in the "Test Log" excel file. Please refer to that document for details on each specific test date/time, constraint parameters and model hardware setup details. Sim model can be found in the associated MHKDR link below.

16 TIDAL AND WAVE POWER↗

Information quality-control model

Model serves as graphic tool for estimating complete product objectives from limited input information, and is applied to cost estimations, product-quality evaluations, and effectiveness measurements for manpower resources allocation. Six product quality levels are defined.

Vincent, D. A.↗

Dynamic control models of the semicircular canals

Vestibular system semicircular canals mathematical model determination of galvanic stimulation and directional preponderance, considering visual, postural and vehicle orientation feedback loops

Young, L. R.↗

Improvements and validation of the erythropoiesis control model for bed rest simulation

The most significant improvement in the model is the explicit formulation of separate elements representing erythropoietin production and red cell production. Other modifications include bone marrow time-delays, capability to shift oxyhemoglobin affinity and an algorithm for entering experimental data as time-varying driving functions. An area of model development is suggested by applying the model to simulating onset, diagnosis and treatment of a hematologic disorder. Recommendations for further improvements in the model and suggestions for experimental application are also discussed. A detailed analysis of the hematologic response to bed rest including simulation of the recent Baylor Medical College bed rest studies is also presented.

Leonard, J. I.↗