Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Points”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Integrate Latimer Controls' Solution into RTAC (CRADA Final Report, CRD-23-24672)

Latimer Controls, Inc. was awarded two vouchers under the Department of Energy's American-Made Solar Prize Round 6 to conduct collaborative research at a national laboratory. The National Renewable Energy Laboratory (NREL) was selected as a partner to assist Latimer Controls in the performance evaluation of its photovoltaic (PV) control software. This collaboration focuses on developing a hardware-in-the-loop (HIL) testbed at NREL, which will be used to test and validate the Latimer PV control technology in a realistic yet de-risked environment. Both Latimer and NREL teams will work together to analyze the collected test data, derive insights, and disseminate the scientific findings. Recent studies underscore the potential of solar energy as a zero-marginal-cost and zero-emission flexibility resource within the bulk power system, particularly when integrated with advanced control systems. To enhance the performance of such systems, Latimer Controls has developed leading-edge technologies, including machine learning (ML) algorithms and hierarchical inverter set-point allocation methods. These innovations are designed to estimate the operational headroom of large PV plants for grid integration and control. However, comprehensive validation under real-world conditions remains necessary. To address this gap, the concurrent CRADA project proposes the real-world application and validation of the Latimer Control solution within a HIL environment. Initially, the Latimer algorithm was developed and tested within MATLAB Simulink, a platform suitable for research-level simulations and iterative development. However, transitioning this technology to a real solar site as an industry-ready solution necessitates implementation in a format compatible with widely used solar power plant controllers. In this additional CRADA work, the MATLAB Simulink-based logic will be translated into Structured Text, a programming language compliant with IEC 61131 standards, which is commonly used for custom logic implementations in industry-leading programmable logic controllers (PLCs), such as the Schweitzer SEL real-time automation controller (RTAC). This transition will facilitate the deployment of the Latimer Control solution in real-world solar power plants, thereby advancing the technology towards commercialization.

14 SOLAR ENERGY↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Nuclear microreactor transient and load-following control with deep reinforcement learning

The economic feasibility of nuclear microreactors will depend on minimizing operating costs through advancements in autonomous control, especially when these microreactors are operating alongside other types of energy systems (e.g., renewable energy). This study explores the application of deep reinforcement learning (RL) for real-time drum control in microreactors, exploring performance in regard to load-following scenarios. By leveraging a point kinetics model with thermal and xenon feedback, we first establish a baseline using a single-output RL agent, then compare it against a traditional proportional–integral–derivative (PID) controller. This study demonstrates that RL controllers, including both single- and multi-agent RL (MARL) frameworks, can achieve similar or even superior load-following performance as traditional PID control across a range of load-following scenarios. In short transients, the RL agent was able to reduce the tracking error rate in comparison to PID by one half to one third. Over extended 300-minute load-following scenarios in which xenon feedback becomes a dominant factor, PID maintained better accuracy, but RL still remained within a 1% error margin despite being trained only on short-duration scenarios. This highlights RL’s strong ability to generalize and extrapolate to longer, more complex transients, affording substantial reductions in training costs and reduced overfitting. Furthermore, when control was extended to multiple drums, MARL enabled independent drum control as well as maintained reactor symmetry constraints without sacrificing performance---an objective that standard single-agent RL could not learn. We also found that, as increasing levels of Gaussian noise were added to the power measurements, the RL controllers were able to maintain lower error rates than PID, and to do so with at least 10% and upwards of 150% less control effort. These findings illustrate RL's potential for autonomous nuclear reactor control, laying the groundwork for future integration into high-fidelity simulations and experimental validation efforts.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

High resolution identification and quantification of diffuse deep groundwater discharge in mountain rivers using continuous boat-mounted helium measurements

Discharge of deeply sourced groundwater to streams is difficult to locate and quantify, particularly where both discrete and diffuse discharge points exist, but diffuse discharge is one of the primary controls on solute budgets in mountainous watersheds. The noble gas helium is a unique identifier of deep groundwater discharge because groundwater with long residence times is commonly enriched in helium. In this study, a portable mass spectrometer was used to measure longitudinal variation in dissolved helium concentrations in two mountainous rivers at high spatial resolution not feasible with traditional sampling techniques. Helium profiles were then simulated using a mass-balance model to quantify longitudinal variation in groundwater discharge to the receiving rivers. Results indicate helium concentrations were enriched by multiple orders of magnitude above atmospheric equilibrium in both rivers and that this persisted for up to 18 km below observed pulse inputs in the Colorado River. Helium mass-balance models match observed longitudinal patterns with the exception of sharp initial increases in helium observed in the rivers. Increased longitudinal groundwater discharge rates correspond to mapped geologic structures in both watersheds that likely transport deep geothermal water. Models show variable sensitivity to spatial assignment of input variables representing the groundwater source, illustrating the importance of collecting data from discrete groundwater discharges where possible. The methodology shows promise for field experiments designed to assess air–water exchange rates and to quantify total groundwater discharge from a combination of discrete and diffuse sources.

Deep groundwater↗

Effects of Normal and Lateral Electric Fields on Membrane Mechanical Properties

As a core component of biological and synthetic membranes, lipid bilayers are key to compartmentalizing chemical processes. Bilayer morphology and mechanical properties are heavily influenced by electric fields such as those caused by biological ion concentration gradients. We present atomistic simulations exploring the effects of electric fields applied normally and laterally to lipid bilayers. We find that normal fields decrease membrane tension, while lateral fields increase it. Free energy perturbation calculations indicate the importance of dipole-dipole interactions to these tension changes, especially for lateral fields. We additionally show that membrane area compressibilities can be related to their cohesive energies, allowing us to estimate changes in membrane bending rigidity under applied fields. We find that normal fields decrease bending rigidity, while lateral fields increase it. Furthermore, these results point to the use of directed electric fields to locally control membrane stiffness, thereby modulating associated cellular processes.

Chemistry↗

Base excision repair and double strand break repair cooperate to modulate the formation of unrepaired double strand breaks in mouse brain

Abstract We lack the fundamental information needed to understand how DNA damage in the brain is generated and how it is controlled over a lifetime in the absence of replication check points. To address these questions, here, we integrate cell-type and region-specific features of DNA repair activity in the normal brain. The brain has the same repair proteins as other tissues, but normal, canonical repair activity is unequal and is characterized by high base excision repair (BER) and low double strand break repair (DSBR). The natural imbalance creates conditions where single strand breaks (SSBs) can convert to double strand breaks (DSBs) and reversibly switch between states in response to oxidation both in vivo and in vitro. Our data suggest that, in a normal background of repair, SSBs and DSBs are in an equilibrium which is pushed or pulled by metabolic state. Interconversion of SSB to DSBs provides a physiological check point, which would allow the formation of unrepaired DSBs for productive functions, but would also restrict them from exceeding tolerable limits.

Science & Technology - Other Topics↗

Differential roles of kinetic on- and off-rates in T-cell receptor signal integration revealed with a modified Fab’-DNA ligand

Antibody-derived T-cell receptor (TCR) agonists are commonly used to activate T cells. While antibodies can trigger TCRs regardless of clonotype, they bypass native T cell signal integration mechanisms that rely on monovalent, membrane-associated, and relatively weakly binding ligand in the context of cellular adhesion. Commonly used antibodies and their derivatives bind much more strongly than native peptide major histocompatibility complex (pMHC) ligands bind their cognate TCRs. Because ligand dwell time is a critical parameter that tightly correlates with physiological function of the TCR signaling system, there is a general need, both in research and therapeutics, for universal TCR ligands with controlled kinetic binding parameters. To this end, we have introduced point mutations into recombinantly expressed α-TCRβ H57 Fab to modulate the dwell time of monovalent Fab binding to TCR. When tethered to a supported lipid bilayer via DNA complementation, these monovalent Fab’-DNA ligands activate T cells with potencies well-correlated with their TCR binding dwell time. Single-molecule tracking studies in live T cells reveal that individual binding events between Fab'-DNA ligands and TCRs elicit local signaling responses closely resembling native pMHC. The unique combination of high on- and off-rates of the H57 R97L mutant enables direct observations of cooperative interplay between ligand binding and TCR-proximal condensation of the linker for activation of T cells, which is not readily visualized with pMHC. This work provides insights into how T cells integrate kinetic information from TCR ligands and introduces a method to develop affinity panels for polyclonal T cells, such as cells from a human patient.

Science & Technology - Other Topics↗

Design and Performance Evaluation of a Resistive Control Using a Hydraulic PTO System for the TALOS Wave Energy Converter

This study is focused on developing a numerical model to evaluate the performance of a hydraulic PTO system for the TALOS Wave Energy Converter. The WEC device is described and the architecture of the hydraulic PTO system is presented with detail. The WEC is modeled using WEC-Sim, and the PTO is modeled using the Simscape Fluids library from Simulink. The hydraulic PTO is based on a constant pressure configuration that is suitable for WEC passive control. The hydraulic system is composed by a set of rectifying valves and two hydraulic accumulators that reduce the stiffness of the system and also serve as energy storage devices. One of the advantages of this hydraulic PTO architecture is the possibility of controlling the electric generator to operate around the optimal efficiency operating point. The main components of the hydraulic PTO are off-the-shelf devices that are commercially available, which will facility a future deployment of the designed system. The design variables used for this study are the accumulator size, the maximum pressure in the accumulators, the hydraulic motor maximum displacement, and the shaft speed in the electric generator. The performance of the system is evaluated individually, using sinusoidal inputs that replicates regular wave conditions. In addition to this, the numerical model of the PTO is coupled to a WEC-Sim simulation of the TALOS Wave Energy Converter with six PTOs to generate a wave-to-wire model. The main objective of this work is to present a comprehensive design methodology that could serve as a guideline for future research efforts focused on implementing control algorithms on multi degree of freedom WECs.

hydraulic systems↗

CODARcode/MGARD

MGARD is a software providing error-controlled lossy compression and data refactoring based on multi-grid theories. It transforms floating-point scientific data into a multilevel representation, followed by quantization and lossless encoding processes, resulting in a self-describing compressed buffer. It supports diverse data topologies, error control norms, and computing architectures.

Chen, Jieyang [University of Oregon]↗

Power Analysis of an ePump Applied to the Linear Functions of an Agricultural Planter

Like many other industries, the agricultural industry has recently ex-perienced pressure to reduce vehicle emissions while improving productivity. Electric actuation is perceived as a viable solution to replace or augment hydrau-lic and mechanical actuation. However, electrification presents challenges with regards to linear functions, where hydraulic actuators have advantages in terms of compactness, tolerance to contamination and resistance to shocks. A combined electro-hydraulic actuation architecture can leverage the benefits of both electric and hydraulic actuation, while reducing the drawbacks of both approaches. This work investigates the potential of a centralized electric driven pump (ePump) system powering the pressure-controlled linear functions of an agricul-tural planter, with the goal of improving the operating point of the main supply pump. In this application, the rotary functions are hydraulically actuated, alt-hough such a solution could be applied also to electric rotary actuation. This is accomplished by setting the ePump to boost the pressure supplied by the tractor to the level required by the linear functions. An accumulator is used to stabilize the flow requirements of the linear functions, and control the pressure supplied to the actuators. Two control schemes are proposed for the regulation of the ac-cumulator pressure, one favoring an efficient operating point for the ePump, the other favoring stable steady state operation. A simulation model of the baseline system and proposed system is developed and validated using experimental data from a full-scale machine. Using the vali-dated simulation, both control architectures are then evaluated for improvement in system power consumption and dynamic requirements on the ePump to assess their effectiveness. Both systems demonstrate significant improvement in power consumption over the baseline system, with the best solution improving effi-ciency by 64%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Degrees of Rate Control in Interconnected Reaction Networks

Overall reactions in interconnected networks exhibit net, forward, and reverse rates that are governed by both constitutive elementary steps in the pathway of interest and branching elementary steps that lead to alternative products. Accordingly, steps in branching pathways exhibit negative net, forward, and reverse degrees of rate control, as they reduce reaction flux to the desired product. We here contextualize the forward and reverse degrees of rate control in terms of kinetic resistances (inverse of rates) and leverage the additive nature of kinetic resistance to decouple kinetic driving forces contributed by constitutive elementary steps and branching points (nodal species) in interconnected networks. Regardless of the network connectivity, forward and reverse degrees of rate control are shown to converge at equilibrium. Away from equilibrium, we identify two critical features of interconnected networks: stoichiometric regularity─condition where all stoichiometric numbers are unity─and pathway symmetry around nodal species─condition where branching pathways share the same rate constants, stoichiometry, and species concentrations/activities─that result in (i) equal forward, reverse, and consequently net degrees of rate control and (ii) forward and reverse degrees of rate control that exhibit constant offsets, respectively, across all extents of reaction. Furthermore, our discourse further provides a mathematical description for the influence of stoichiometric irregularity and pathway asymmetry on forward and reverse degrees of rate control. Altogether, the presented work details the effects of network (inter)connectivity and stoichiometry on reaction kinetics and, in doing so, establishes general protocols for capturing these effects as additive terms in the formulation of forward and reverse degrees of rate control.

10 SYNTHETIC FUELS↗

Digital Filter Design for Point-on-Wave Sensors: Highlighting Frequency Response Limitations and Enhancing Grid Simulation Accuracy

Data is proving to be the backbone of today's and, more importantly, tomorrow's grid. As the system changes and introduces fast-acting devices like power electronics, overall observability tends to decrease from the utility point-of-view. This can be mitigated by adding more high-fidelity sensors onto the grid, although this incurs a cost. These sensors are never ideal, and each have unique frequency responses that may influence the data produced. This may, in turn, impact the protection and control of the power grid. This paper presents a methodology of representing these point-on-wave sensors digitally by estimating digital-filter representations of them, thereby introducing means of improving the sensor models used in electromagnetic-transient (EMT) simulations. This may help with identifying potential high-frequency, sensor-induced distortions, and system resonance compensation. Three commercial-grade medium-voltage point-on-wave sensors are utilized in a lab environment to obtain experimental frequency responses with a frequency sweep, and it is shown that both Infinite Impulse Response (IIR) and Finite Impulse Response (FIR) filter representations may approximate these responses with varying degrees of accuracy, though each has their own strengths and weaknesses. It is found that, in general, FIR estimation better approximates these sensors than IIR estimation does.

Wilson, Aaron [ORNL] (ORCID:0000000327331697)↗

Real-time plasma equilibrium reconstruction and shape control for the MAST Upgrade tokamak

Real-time magnetic control has been developed to deliver precise control of multiple plasma shape parameters for advanced divertor configurations, including double-null, Super-X, X-point target and X-divertor for the first time on the MAST Upgrade (MAST-U) spherical tokamak. Successful real-time magnetic equilibrium control of different plasma shape variables has been accomplished in the 2022–2023 MAST-U experimental campaign for the advanced MAST-U divertor configurations. Application of the MAST-U boundary reconstruction algorithm, LEMUR, is described and compared with off-line equilibrium reconstruction and diagnostic measurements. The process of design and verification of the axisymmetric magnetic control schemes using a suite of control analysis tools (known collectively as TokSys) is also described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A multigigabit link layer protocol for single picosecond latency determinism using AMD ultrascale+ GTH and GTY transreceivers

recision timing distribution systems require determin istic and repeatable high speed serial data link latency. The EIC Timing Data Link will employ a specialized link layer protocol for deterministic multigigabit communication us ing AMD Ultrascale+ GTH and GTY transceivers. Link la tency must also be measurable to accurately compensate in real time for latency variations of the physical medium. The point-to-point link is full duplex and fully synchronous with a latency control algorithm to align the internal clocks of each system with picosecond resolution. Deterministic clock domain crossing between systems is ensured using static timing analysis of the elastic buffer control signals.

43 PARTICLE ACCELERATORS↗

Real-Time Sea State Estimation for Wave Energy Converter Control via Machine Learning

Wave energy converters (WECs) harness the untapped power of ocean waves to generate renewable energy, offering a promising solution to sustainable energy. An optimal WEC control strategy is essential to maximize power capture that dynamically adjusts system parameters in response to rapidly changing sea states. This study presents a novel control approach that leverages neural networks to estimate sea states from onboard WEC measurements such as position, velocity, and force. Using a point absorber WEC device as a test platform, our proposed approach estimates sea states in real-time and subsequently adjusts PID controller gains to maximize energy extraction. Simulation results across diverse sea conditions demonstrate that our strategy eliminates the need for external wave monitoring equipment while maintaining power capture efficiency. The results show that our neural network-based control technique can improve power capture by 25.6% while significantly reducing system complexity. This approach offers a practical alternative for WEC deployments where direct wave measurements are either infeasible or cost prohibitive.

PIDcontrol↗

SULI End of Summer Presentation

This presentation made on Power Point is a brief summary of my work enhancing the Supervisory Control and Data Acquisition (SCADA) architecture for Idaho National Lab’s Critical Infrastructure Test Range Complex (CITRC). This work was part of an on-going project to create a digital twin of CITRC that will be implemented for resiliency research. Resiliency is growing more important as extreme weather, aging infrastructure, and increasing load all exert stress on the United States power grid. This presentation highlights how I documented the existing devices and data flow on site and then updated specific device settings to better support the needs of the project. It also examines future use of this data in the digital twin data warehouse (DeepLynx), and future Artificial Intelligence and Advanced Distribution Management System applications. It will be presented to the B751 Water and Energy Systems Analysis group at INL during my last week.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Power-Maximizing Region 2 Controllers for Wind and Marine Turbines

Wind and marine energy are rapidly growing and complementary technologies that share some techniques for simplified modeling and control, particularly in below-rated flow speeds. A turbine operator has several choices of controller for maximizing power in Region 2. The simple and ubiquitous KΩ 2 control law is often effective but limited in its flexibility. Alternative controllers use reference tracking to split the control objectives into a low-bandwidth optimal tip-speed ratio tracking loop to maximize steady-state power and a higher-bandwidth proportional-integral control loop to reject inflow turbulence. Several options exist for identifying the slowly varying optimal set point during operation, based on estimating the inflow velocity or filtering the power or torque signals. This study compares the trade-offs between performance and other design priorities for a few choices of reference-tracking controller in the literature for reference wind and marine turbines. Analysis is performed in the frequency domain using the linearization of each controller, and the impact of turbulent disturbances on the closed-loop system is described. The controllers are simulated in OpenFAST to analyze their performance with higher-order nonlinear turbine dynamics.

17 WIND ENERGY↗

A CHIL Validation of Machine Learning-Assisted Methods for Real-Time Controls of Solar PV for Grid Services

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been proposed; however, these technologies lack comprehensive validation under real-world application scenarios. This paper addresses this gap by designing and developing a controller-hardware-in-the-loop framework to evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. Simulation results indicate the superior performance of an ML-based approach compared to the conventional reference-control grouping-based approach, showcasing its potential to support grid stability and operational efficiency.

closed-loop validation↗