On the elastocaloric effect in CuAlBe shape memory alloys: A quantitative phase-field modeling approach

We report the reversible stress-induced phase transformation in shape memory alloys (SMAs) is a dissipative process during which heat is absorbed or released. The inherent temperature variations inside the material has an elastocaloric effect (eCE) with appealing applications in solid-state cooling technology such as compact and efficient on-board refrigeration system for eletronic devices. In this manuscript, we conduct the first study of eCE of CuAlBe SMAs utilizing phase-field modeling. For an applied stress of 500 MPa, the results for polycrystalline Cu-Al11-2Be (at. %) show a minimum adiabatic unloading temperature change of -10 K over a pseudoelastic window of 40 K. In the absence of plastic deformation, the material demonstrates good reproducibility of the eCE over a few loading–unloading cycles. The presence of plastic deformation is found to cause functional fatigue that deteriorates the cooling capacity; however, the coefficient of performance only decreases from 9.04 to 8.03, which is still a very good value. These results place CuAlBe as a frontrunner SMA for solid-state cooling compared to the expensive NiTi.

36 MATERIALS SCIENCE↗

Analyzing the Multiscale Impacts of Implementing Energy-Efficient HVAC Improvements Through Energy Audits and Economic Input–Output Analysis

Abstract Heating, ventilation, and air-conditioning (HVAC) systems are usually an industry’s highest consumer of energy, most of which goes toward space cooling in buildings. Industrial energy-efficiency audits not only benefit manufacturers but also generate significant economic and environmental benefits to localities, states, and the nation. This article analyzes the micro- and macro scale impacts of implementing energy-efficient HVAC systems by integrating the industrial building energy data with the macroeconomic regional economic flow model. Micro-scale data include 10 years of historical energy, cost, and carbon dioxide savings achieved from energy-efficient HVAC implementation offered to manufacturers through industrial energy audits. The data were integrated into the macroeconomic modeling framework to illuminate the cascading regional economic impacts of implementing energy-efficient HVAC recommendations in manufacturing facilities. Results show that if recommendations had been implemented throughout all manufacturers in the region, $656 M energy costs would have been directly saved, 7.8 million metric tons of carbon dioxide emissions would have been avoided, and 4387 jobs could have been created, resulting in a total annual economic impact of $899 M stemming from direct, indirect, and induced impacts. The results offer insight into how industrial energy systems can be designed and provide models for how communities can accomplish a net-zero society.

Energy & Fuels↗

Staying cool: The development of India's pioneering energy efficiency policy for chillers

Abstract Chillers are the key energy‐consuming piece of equipment in most large space cooling systems. They can account for more than 40% of total energy consumption in any typical commercial building and in specific industrial building installations depending on the product and process. With climate change driving rapidly rising demand for commercial and industrial cooling, especially in emerging economies, energy efficiency policies for chillers are crucial to moderate future electricity demand and thereby minimize greenhouse gas emissions. However, most developing and emerging economies lack energy efficiency policies for this significant and growing cooling equipment sector. India recently announced new energy efficiency policies for chillers, projected to avoid 28 TWh of electricity consumption and 23 million tons of CO 2 emissions cumulatively through 2030. This article presents a case study of the unique challenges and solutions required to design a new energy efficiency policy for chillers in India. First, the energy consumed in chiller systems is sensitive to building occupancy, load changes, seasonal variations, operation and maintenance, and climatic conditions. In order to address these sensitivities, the chiller testing standard in India factors local weather and temperature conditions into energy performance ratings to account for these sensitivities. Further, every large chiller is a customized product, therefore developing a viable policy and implementation process required collaboration with international and national experts in standardization, manufacturers, building consultants, and testing laboratories. This article is categorized under: Energy Efficiency > Economics and Policy Solar Energy: Thermal ‐‐> Climate and Environment

Mukherjee, P. K.↗

Department of Energy/IDEA: More best-practices research

This article continues the overview of the U.S. Department of Energy and IDEA collaboration by highlighting additional case studies that demonstrate innovative engineering approaches in district energy systems. It focuses on how campuses are improving efficiency, integrating advanced technologies, and reducing energy use and emissions through data-driven strategies. The University of Cincinnati is featured for its highly efficient chilled water system, using advanced algorithms and upgraded “smart chillers” to optimize performance, reduce energy consumption, and lower costs. Wake Forest University emphasizes a data-informed modernization process, using system optimization and targeted building improvements to significantly boost efficiency and reduce overall energy use. Arizona Western College showcases creative solutions to extreme cooling demands, including system redesign, smart controls, and thermal storage to improve reliability and cut peak energy costs. Overall, the article demonstrates that combining innovative engineering, real-time data analysis, and system optimization can significantly enhance performance, reduce emissions, and deliver cost savings in district energy systems.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Numerical and experimental analysis of precooled desiccant system

This paper presents a numerical and experimental study of four novel, desiccant air-conditioning systems based on pre-cooling of the ambient air. The purpose of the study is to: 1) establish which configuration is most profitable for the future studies through numerical and experimental methods; 2) verify the concept of precooled system and confirm that it is working in experimental conditions (for this purpose two prototypes of evaporative cooling units were developed and compared for different operation arrangements with desiccant wheel); 3) Analyze practical aspects of the systems, which includes water consumption analysis, economic analysis and establishing operational modes during a cooling season in temperate climate conditions (the proposed solution has a significant advantage during operation in a temperate climate, since it can utilize its first evaporative cooler the only source of cooling energy when the humidity of outdoor air allows to to meet the latent cooling load). Four arrangements of the system with different dew point evaporative air cooler prototypes were selected and developed for comparative analysis. The system was simulated as a whole, also, each component was individually tested on measurement station. develop the optimal arrangement of the system through numerical and experimental analysis. Four different performance indicators were considered: thermal COP (Coefficient Of Performance), the ERR (Energy Efficiency Ratio), coefficient a describing the potential in compensating indoor cooling loads, water consumption ratio. Also costs of the systems were compared through economic analysis. It was established that arrangement which is characterized by best-averaged performance in terms of all considered factors is a unit combined with two different types of evaporative coolers (marked as System B)- this is caused by the favorable arrangement of two units, where one is better suited to the pre-cooler role, while the other is better suited as the post-cooler.

42 ENGINEERING↗

Flexible Fully-Decoupled Nuclear Plants with Thermal Energy Storage - Technoeconomic Optimization

New nuclear power plants may be one of the technologies for future zero carbon electricity production. These future systems will however also need significant flexibility to cope with fluctuating demand and large share of intermittent renewable supply, rather than running in conventional baseload generation. The present work explores the use of thermal energy storage (TES) as a buffer between the reactor heat and its conversion to electricity, enabling flexible operation of nuclear plants. The focus is on maximizing flexibility, ideally as full decoupling of the nuclear and power cycle islands, as well as on system efficiency in various modes. A system design presented for a high temperature gas cooled reactor (HTGR) presents a slightly complex solution, as separate high- and low-temperature TES systems are required in order to cover the extended temperature range. Although this configuration imposes certain limitations on the discharge system configuration, it also presents the opportunity to design a more efficient system. For this case in particular, a steam reheat cycle is advantageous. Dynamic models were developed for the decoupled system in order to generate insights into aspects of off design operation and system control. A technoeconomic analysis, furthermore, provides sizing and costing of the component, followed by size and dispatch economic optimization considering energy arbitrage. This optimization shows that in all explored markets, the addition of TES system with the proposed configuration results in positive impact on project net present value. Further sensitivity analyses show impact of multiple inputs and possible technical limitations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Increased panel height enhances cooling for photovoltaic solar farms

We report solar photovoltaic (PV) systems suffer substantial efficiency loss due to environmental and internal heating. However, increasing the canopy height of these systems promotes surface heat transfer and boosts production. This work represents the first wind tunnel experiments to explore this concept in terms of array flow behavior and relative convective heat transfer, comparing model solar arrays of varied height arrangements - a nominal height, extended height, and a staggered height configuration. Analyses of surface thermocouple data show average Nusselt number (Nu) to increase with array elevation, where panel convection at double height improved up to 1.88 times that of the nominal case. This behavior is an effect of sub-array entrainment of high velocity flow and panel interactions as evidenced through flow statistics and mean kinetic energy budgets on particle image velocimetry (PIV) data. The staggered height arrangement encourages faster sub-panel flow than in the nominal array. Despite sub-array blockage due to the lower panel interaction, heat shedding at panel surfaces promotes improvements on over 1.3 times that of the nominal height case.

14 SOLAR ENERGY↗

Demonstrating non-isothermal vacuum membrane air dehumidification for efficient next-generation air conditioning

Vacuum membrane air dehumidification has gained significant interest in recent years as a highly efficient means of air dehumidification. Prior theoretical modeling work by the authors introduced the Active Membrane Energy Exchanger (AMX) concept, which combines active heat exchange and vacuum membrane dehumidification into one non-isothermal system, and found that it could outperform other air conditioning technologies under many conditions. However, no experimental literature exists on combining active heat exchangers and vacuum membrane dehumidification. Here, the goal of the present study is to evaluate the dehumidification (mass transfer) performance of the AMX concept relative to isothermal membrane dehumidification through three main methodologies: (1) membrane material-level characterization, (2) experimental prototype development and testing, and (3) computational fluid dynamics (CFD) simulations. The dense membranes used in this work showed up to a 40% increase in water vapor permeance at cooler temperatures, and the prototype system showed up to a 6% increase in humidity removal when the air was simultaneously cooled. Furthermore, the membrane module-integrated heat exchange tubes provided additional mixing and turbulence, leading to a 4–8% increase in humidity removal. The upper limit coefficient of performance was equal to approximately 2.2, necessitating advanced system designs to improve efficiency. This study is the first to highlight that combining the cooling and vacuum dehumidification processes can improve dehumidification performance.

30 DIRECT ENERGY CONVERSION↗

Electrocoagulation Combined with Ultrafiltration Membranes as Pretreatment for RO Desalination of Synthetic Cooling Tower Blowdown Water

Electrocoagulation (EC), an electrochemical water treatment process, is commonly used to remove particulate and colloidal matter from water. Here, in this study, we demonstrate that EC, when coupled with membrane filtration, is also capable of removing dissolved species, such as Ca + , Mg 2+ , and SiO x . The removal of such species is important for downstream membrane-based desalination treatment of the water that can suffer from reduced performance due to membrane scaling. Here, we describe how EC can be combined with a low-pressure membrane (LPM) system to offer efficient (and potentially universal) pretreatment for downstream membrane desalination. Synthetic water, simulating cooling tower blowdown (CTBD) with elevated concentrations of hardness and silicates (Ca: 418 ppm, Mg: 63 ppm, SiO 2 : 50 ppm) is treated using EC coupled to ultrafiltration (UF) to remove Mg up to 30 ± 1%, Ca up to 29 ± 1%, and silica up to 99 ± 1%. We evaluated the effectiveness of the EC-UF pretreatment system in reducing downstream RO scaling using thermodynamic modeling to predict the saturation index (SI) at the RO membrane/water interface. An SI value below zero (SI < 0) indicates under-saturated conditions (with respect to a particular mineral) where mineral scaling does not take place, which correlates with improved water recovery. Our findings suggest that the EC-UF pretreatment system was able to increase water recovery by up to 30%, compared to 0% recovery without pretreatment, under optimal conditions (feed solution pH of 7 and an EC charge loading of 1800 C/L). Finally, we conducted an economic analysis showing that implementing an EC-UF system for CTBD water could yield a cost benefit of up to $\$$14.13 per m 3 compared to direct brine disposal.

cooling tower blowdown↗

Field Validation of Electrochemical Water Filtration System on an Open Loop Cooling Tower at Nissan Manufacturing Plant in Canton, Mississippi

The U.S. Department of Energy Industrial Efficiency and Decarbonization Office’s Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized technologies in the industrial sector to help inform decisions towards accelerating commercialization and deployment. This ITV demonstration investigated the performance of an early-commercial electrochemical water treatment technology on a cooling tower at an automotive plant. Cooling towers are vital equipment for dissipating heat from industrial processes, but they face challenges related to scaling, corrosion, and the growth of biological contaminants. Effective cooling tower water treatment is therefore essential in reducing these contaminants and other total suspended solids (TSS) and total dissolved solids (TDS). Various treatment systems, such as sand-based filters, centrifugal separators, and disc filters are available, each having its advantages and drawbacks. ElectroCell Systems, a filtration technology provider, offers an electrochemistry-based water treatment system that is skid-mounted and can be configured as a side-stream filtration system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

High-Temperature Particle Heat Exchanger for sCO2 Power Cycles

Particle receivers are being pursued to provide substantial performance improvements through higher temperatures (>700 °C) for more efficient and cost-effective concentrating solar power (CSP) systems with direct storage. However, the interface between the solar-collection and power-block subsystems - a high-temperature particle/supercritical CO 2 (sCO2) heat exchanger - has not been developed. The objective of this project is to design, construct, and test a first-of-a-kind particle-to-sCO2 heat exchanger. This work will enable emerging sCO2 power cycles that have the potential to meet SunShot targets of 50% thermal-to-electric efficiency, dry cooling with 40 °C ambient temperature, and $0.06/kWh for CSP systems. The development of next-generation particle-based systems and methods with potentially high consequences for improved performance and cost savings for CSP applications is an appropriate role for the government.

14 SOLAR ENERGY↗

An Advanced Cooling Device for Concentrated Photovoltaic Systems

Concentrated photovoltaics (CPV) have the potential to significantly enhance the energy conversion utilization of solar panels and reduce solar generation costs, making them a crucial area of advancement in solar power generation technology. However, the concentration of sunlight can lead to overheating of solar panels, resulting in a notable reduction in both the efficiency of solar power generation and the lifespan of the panels. This challenge remains the predominant technical hurdle that hinders the application of concentrated photovoltaic power generation technology. In this study, we propose a new cooling method for concentrated photovoltaic power generation systems via an integrated approach of incorporating Phase-Change Thermal Storage (PCTS) and Thermoelectric Generator (TEG) technology. This new method not only enhances the overall system's electricity generation efficiency but also effectively resolves the technical challenge of concentrated photovoltaic panel overheating issues, ensuring the continuity of concentrated photovoltaic power generation and extending the lifespan of solar panels and their components. In order to make full use of the wasted heat generated by photovoltaic power generation and effectively improve the power generation efficiency of the system, this work developed a phase change heat storage device based on a phase change material. This device uses the temperature difference between day and night to recover wasted heat from photovoltaic power generation. Through integration with the thermoelectric power generation system, thermal energy can be converted into electrical energy. In addition, the Peltier effect of thermoelectric materials is used to construct a photovoltaic panel overheating protection system, which significantly improves the reliability and service life of the system.

14 SOLAR ENERGY↗

An Advanced Cooling Device for Concentrated Photovoltaic Systems

Concentrated photovoltaics (CPV) have the potential to significantly enhance the energy conversion utilization of solar panels and reduce solar generation costs, making them a crucial area of advancement in solar power generation technology. However, the concentration of sunlight can lead to overheating of solar panels, resulting in a notable reduction in both the efficiency of solar power generation and the lifespan of the panels. This challenge remains the predominant technical hurdle that hinders the application of concentrated photovoltaic power generation technology. In this study, we propose a new cooling method for concentrated photovoltaic power generation systems via an integrated approach of incorporating Phase-Change Thermal Storage (PCTS) and Thermoelectric Generator (TEG) technology. This new method not only enhances the overall system's electricity generation efficiency but also effectively resolves the technical challenge of concentrated photovoltaic panel overheating issues, ensuring the continuity of concentrated photovoltaic power generation and extending the lifespan of solar panels and their components. In order to make full use of the wasted heat generated by photovoltaic power generation and effectively improve the power generation efficiency of the system, this work developed a phase change heat storage device based on a phase change material. This device uses the temperature difference between day and night to recover wasted heat from photovoltaic power generation. Through integration with the thermoelectric power generation system, thermal energy can be converted into electrical energy. In addition, the Peltier effect of thermoelectric materials is used to construct a photovoltaic panel overheating protection system, which significantly improves the reliability and service life of the system.

Gou, Yimeng↗

Modeling and Validation of a Residential Multi-Functional Variable Refrigerant Flow Heat Pump System with Heat Recovery

To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.

Modeling, Variable refrigerant flow (VRF) systems,↗

Experimental study of a tri-functional propane hydronic heat pump

This study investigates the performance of a propane hydronic heat pump system for space cooling, heating, and water heating applications, focusing on various operational conditions, with a total refrigerant charge below 1200 g. Cooling performance was evaluated at different outdoor temperatures, compressor stages (capacity levels), and water flow rates. The results showed that the coefficient of performance (COP) for cooling was higher at lower outdoor temperatures, with peak values exceeding 5.0 under low-stage operation and lower water flow rate. The cooling capacity increased with higher flow rates and compressor stages, reaching 12 kW. Space heating performance, evaluated at ambient temperatures ranging from −8.3 °C to 16.7 °C, revealed a decrease in COP with lower temperatures. However, high-stage operation maintained higher heating capacities even at low temperatures. The system demonstrated high Heating Seasonal Performance Factors (HSPF), exceeding 10.0. For water heating, the COP decreased with lower ambient temperatures and higher supply water temperatures. The system efficiently heated an 189-L water tank, outperforming conventional water heaters, with process COPs exceeding 4.0 under cooling-season conditions. Despite some efficiency loss due to defrosting at low temperatures, the propane heat pump consistently delivered strong performance. Seasonal energy efficiency ratios (SEER) and seasonal heating COP values indicated significant overall efficiency. The study concludes that propane is a promising refrigerant for heat pump systems, with future research needed to future reduce total system charge and optimize system performance through advanced controls and heat exchanger designs.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

CoolPINNs: A physics-informed neural network modeling of active cooling in vascular systems

Emerging technologies like hypersonic aircraft, space exploration vehicles, and batteries avail fluid circulation in embedded microvasculatures for efficient thermal regulation. Modeling is vital during the design and operational phases of these engineered systems. However, many challenges exist in developing a modeling framework. What is lacking is an accurate framework that (i) captures sharp jumps in the thermal flux across complex vasculature layouts, (ii) deals with oblique derivatives (involving tangential and normal components), (iii) handles nonlinearity because of radiative heat transfer, (iv) provides a high-speed forecast for real-time monitoring, and (v) facilitates robust inverse modeling. Here, this paper addresses these challenges by availing the power of physics-informed neural networks (PINNs). We develop a fast, reliable, and accurate Scientific Machine Learning (SciML) framework for vascular-based thermal regulation—called CoolPINNs: a PINNs-based modeling framework for active cooling. The proposed mesh-less framework elegantly overcomes all the mentioned challenges. The significance of the reported research is multi-fold. First, the framework is valuable for real-time monitoring of thermal regulatory systems because of rapid forecasting. Second, researchers can address complex thermoregulation designs since the approach is meshless. Finally, the framework facilitates systematic parameter identification and inverse modeling studies, perhaps the most significant utility of the current framework.

97 MATHEMATICS AND COMPUTING↗

CityBES v2021

City Buildings, Energy, and Sustainability (CityBES) is a web-based data and computing platform, focusing on energy modeling and analysis of a city's building stock to support district or city-scale building energy efficiency programs. CityBES uses an international open data standard, CityGML, to represent and exchange 3D city models. CityBES employs EnergyPlus to simulate building energy use and savings from energy efficient retrofits. Other CityBES features include energy benchmarking, district heating and cooling system modeling, rooftop PV analysis, building performance visualization, heat resilience modeling, as well as urban scale mapping of microclimate and heat vulnerability at census tract level. Different from other tools, CityBES uses integrated open and standard 3D city building data and models each individual building using EnergyPlus. CityBES can be used by urban planners, city energy managers, building owners, utilities, energy consultants and researchers.

Hong, Tianzhen↗