Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cyber Defense”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Evaluation of Joint Cyber/Safety Risk in Nuclear Power Systems

This report presents an analysis of the Emergency Core Cooling System (ECCS) for a generic Boiling Water Reactor (BWR)-4 NPP. The Electric Power Research Institute (EPRI) developed Hazards and Consequences Analysis for Digital Systems (HAZCADS) process is applied to the ECCS and its subsystems to identify unsafe control actions (UCAs) which act as possible cyber events of concern. The analysis is performed for two design basis events: Small-break Loss of Coolant Accident (SLOCA) and general transients (TRANS), such as unintended reactor trip. In previous work, HAZCADS UCAs were combined with other cyber-attack analysis to develop a risk-informed approach; however, this was for a single system. This report explores advanced systems engineering modeling approaches to model the interactions between digital assets across multiple systems which may be targeted by cyber adversaries. The complex and interdependent design of digital systems has the potential to introduce emergent cyber properties that are generally not covered by hazard analyses nor formal nuclear Probabilistic Risk Assessment (PRA). The R&D and supporting analysis presented here explores approaches to predict and manage how interdependent system properties effect risk. To show the potential impact of a successful cyber-attack to formal PRA event tree probabilities, HAZCADS analysis was also used. HAZCADS was also used to model the automatic depressurization system (ADS) automatic actuation. This analysis extended to an integrated system analysis for common-cause failure (CCF). In this aspect, the HAZCADS analysis continued by analyzing plant design details for system connectivity in support of critical plant functions. A dependency matrix was developed to depict the integrated functionality of the interconnected systems. Areas of potential CCF are indicated. Future work could include adversary attack development to show how CCF could be caused, resulting in PRA events. Across the multiple systems that comprise the ECCS, the analysis shows that the change in such probabilities was very different between systems. This indicates that some systems have a larger potential risk impact from successful cyber-attack or digital failure, which indicates a need for these systems to have a higher priority for design and defensive measures. Furthermore, we were able to establish that a risk analysis using any arbitrary threat model establishes an ordering of components with regard to cyber-risk. This ordering can be used to influence the overall system design with an eye to lowering risk, or as a way to understand real-time risk to operational systems based on a current threat landscape. Expert knowledge of both the analysis process and the system being analyzed is required to perform a HAZCADS analysis. The need for a tiered risk analysis is demonstrated by the results of this report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Cyber-Informed Engineering Workbook: SCADA (VoltVAR)

This case study workbook provides a hypothetical project to support discussion and application of Cyber-Informed Engineering principles. Participants in the workshop are encouraged to use the workbook to capture insights and lessons learned.

42 - ENGINEERING↗

Improving Cyber Situational Understanding

Effective cybersecurity operations require the ability to analyze large amounts of information to assess security risks and formulate defensive strategies against adversaries. This has become more complex in recent years as the sprawl and interconnectivity of devices grows through implementation of virtualization, cloud computing, and Internet of Things (IoT). The amount of data and analysis required for effective cybersecurity command and control decisions far exceeds humans’ capacity to perform manually. We characterize the analysis problem as cyber situational understanding. The research presented to improve cyber situational understanding focuses on vulnerability analysis and threat intelligence. Regarding vulnerabilities, entities must analyze and plan work for between thousands and tens of thousands of software vulnerabilities annually. Entities heavily use network firewalls to limit vulnerability exposure. As a result, some of these vulnerabilities permit exposure to adversarial exploitation, whereas others are inaccessible and therefore present negligible risk of exploitation. Distinguishing between high and low risk software vulnerabilities requires a deep understanding of the vulnerability, network firewall protection, and characteristics of the targeted device. This problem is solved by extracting network service features from vulnerability data features using both machine-learning and natural language processing. Then, the network firewall topology is parsed to determine which vulnerabilities are reachable by adversaries. Ultimately, a state-based safety analysis ascertains which vulnerabilities are unsafe. A related vulnerability analysis problem occurs in cybersecurity operations when associating an entity’s hardware and software assets to public vulnerability databases. Assets often reveal hardware and software through installation artifacts and network service identification, and entities store these artifacts in inventory databases. However, software and hardware vendors apply a standard Common Platform Enumeration (CPE) naming convention when publicly reporting vulnerabilities. Associating these two datasets often requires many hours to days of manual inspection. The proposed solution automates the mapping approach of human analysts using fuzzy matching techniques, natural language processing, and, ultimately, machine learning to present a small set of recommendations for mapping the two datasets. The result significantly reduces human analysis time and reduces the occurrence of false positives in vulnerability notifications. Finally, cyber threat intelligence (CTI) requires associating cyber observable artifacts, such as IP addresses, URIs, and file hashes, with cyber threat tactics, techniques, and procedures. Unfortunately, most CTI data is compartmentalized across multiple organizations and cannot be shared due to the legal and reputational risk with cyber threat being associated with the entity. The approach to solving this problem inovlves using a distributed ledger with anonymous token spending and authentication. This allows a consortium of semi-trusted entities to share the workload of curating CTI for a threat sharing community’s cooperative benefit.

Huff, Philip↗

Safety and Security Defense-in-Depth for Nuclear Power Plants

This report describes the risk-informed technical elements that will contribute to a defense-in-depth assessment for cybersecurity. Risk-informed cybersecurity must leverage the technical elements of a risk-informed approach appropriately in order to evaluate cybersecurity risk insights. HAZCADS and HAZOP+ are suitable methodologies to model the connection between digital harm and process hazards. Risk assessment modeling needs to be expanded beyond HAZCADS and HAZOP+ to consider the sequence of events that lead to plant consequences. Leveraging current practices in PRA can lead to categorization of digital assets and prioritizing digital assets commensurate with the risk. Ultimately, the culmination of cyber hazard methodologies, event sequence modeling, and digital asset categorization will facilitate a defense-in-depth assessment of cybersecurity.

97 MATHEMATICS AND COMPUTING↗

Power Sector Cybersecurity Building Blocks

The Power Sector Cybersecurity Building Blocks, developed through the USAID-NREL Partnership and the Resilient Energy Platform, are designed to help a variety of stakeholders improve security for the electrical grid. This effort grows out of USAID and NREL's discussions with utilities around the world, as well as past cybersecurity assessments performed by NREL on dozens of utilities and government agencies, with a focus on the cybersecurity challenges faced by small and under-resourced utilities. This document outlines eleven building blocks for power sector cyber security. It functions as a guide to help organizations develop a robust, balanced cybersecurity defense program. Individually, each building block represents a cluster of related activities within cybersecurity on which an organization should focus. Using the building blocks, organizations can effectively prioritize their cybersecurity efforts to best thwart a wide range of potential cyberattacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Building Blocks for Secure and Prosperous Defense Critical Supply Chains: A Case Study from Microelectronics

Securing defense-critical supply chains, built on resilient and sustainable microelectronics fabrication and deployment, is a national imperative and one that requires an investment in basic and applied research, development, and deployment into industries in (and out of) the Defense Industrial Base (DIB). Critical next steps include the development of pilots for revolutionary concepts in a new formal verification model and the Cyber-Physical Passport (CPP) concept for chain of custody. Critical infrastructure leadership should take action with a sense of urgency. Working in conjunction with the Under Secretary for Acquisition and Sustainment, the Assistant Secretary of Defense for Research and Engineering should establish pilot programs with the Defense Advanced Research Projects Agency and the service labs to build and test both concepts in legacy and new system development.. Additionally, the Pentagon may be aware that an existing Manufacturing Innovation Institute is piloting, with the semiconductor industry, cyber innovations to provide verifiable security properties and guarantees of physical functions to build a more cyber secure, resilient and efficient micro-electronics supply chain.

99 GENERAL AND MISCELLANEOUS↗

Cyber Attack Sequences Generation for Electric Power Grid

Security assessment of cyber-physical energy systems (CPESs) such as the electric power grid is a critical operation to maintain availability, reliability, and quality of service in the presence of persistent threats from malicious cyber actors. Existing security assessment approaches such as penetration testing and red teaming rely on subject matter expert experience and forensic cyber analysis of historical events to perform realistic, threat-informed assessments of CPES defense. CPESs have a large attack surface because of the heterogeneity and complexity of underlying topology, devices, measurements, and vulnerabilities. The aforementioned approaches lead to partial coverage of the attack surface with a large set of unknown but possible exploits. There is a need to automate the CPES attack surface discovery and contextualize it for relevant, highly probable, real-world attack scenarios. We propose a methodology and framework to facilitate the discovery of the CPES attack surface. We present a multilayer attack graph with ranked attack sequences to describe CPES failure scenarios. We present a work-in-progress framework that lists key components to automate the attack modeling and sequence generation. We demonstrate the published National Electric Sector Cybersecurity Organization Resource CPES failure scenario to highlight the trustworthiness of generated attack sequences.

Dutta, Ashutosh↗

Internship Presentation: Integrating Safety and Cybersecurity: Security-by-Design with SOWT Analysis for Reactor Testing

This study covers leveraging reactor testing facilities that are primarily designed with a focus on safety to enhance cybersecurity testing. By incorporating reactor security-by-design with reactor safety-by-design principles and adopting defense-in-depth strategies that emphasize both safety and security, the research evaluates applicable cyber tools, models, and solutions. This includes simulating specific cyber-attack scenarios using reactor simulators and performing SWOT (Strengths, Weaknesses, Opportunities, Threats) analysis to improve the cybersecurity of reactor systems.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Moving Target Defense Routing for SDN-enabled Smart Grid

The increasing attack surface area in the smart grid communication networks is making the grid more susceptible to cyber attacks that can lead to instability of the grid and even blackouts. While there are multiple types of cyber attacks that can impact the grid, Denial of Service (DoS) attacks are relatively easier to inject as they require lesser knowledge about the system as compared to data integrity attacks. Various research works showcase methods to prevent or mitigate the impacts of DoS attacks in the smart grid but the research still lacks in demonstrating the feasibility and efficacy of the solutions in a real-world environment. In this paper, we propose a Moving Target Defense (MTD)-enabled Software Defined Network (SDN) for the Smart Grid communication implemented on a Hardwarein- the-Loop (HIL) Testbed. We showcase the implementation of the proposed architecture of MTD-enabled SDN using Mininet 2.3.0 which enables communication between the physical grid and the control center. The results show the advantages of using MTD based on SDN for the wide-area network (WAN) with much lower packet drop percentages in the case of MTD-based routing in the SDN WAN. Index Terms—SDN,

97 MATHEMATICS AND COMPUTING↗

Resilient Energy Platform. Fact Sheet: Power Sector Cybersecurity Building Blocks

The Power Sector Cybersecurity Building Blocks, developed through the USAID-NREL Partnership and the Resilient Energy Platform, are designed to help a variety of stakeholders improve security for the electrical grid. This effort grows out of USAID and NREL's discussions with utilities around the world, as well as past cybersecurity assessments performed by NREL on dozens of utilities and government agencies, with a focus on the cybersecurity challenges faced by small and under-resourced utilities. This document outlines eleven building blocks for power sector cyber security. It functions as a guide to help organizations develop a robust, balanced cybersecurity defense program. Individually, each building block represents a cluster of related activities within cybersecurity on which an organization should focus. Using the building blocks, organizations can effectively prioritize their cybersecurity efforts to best thwart a wide range of potential cyberattacks.

building blocks↗

Cyber Resilience and Social Equity: Twin Pillars of a Sustainable Energy Future

This paper examines the intersection of security and accessibility within energy systems amidst the rise of grid modernization and digitization, especially considering the regulatory changes and the imperatives of inclusive energy strategies. It addresses the dual need for secure, resilient infrastructure and a commitment to mitigate energy poverty while maintaining equitable access to energy. Amid escalating cybersecurity and physical threats, the paper advocates for sustainable energy delivery systems that ensure robust defenses without compromising the goals of reducing energy poverty and ensuring energy security. This paper identifies the pressing need for Cyber-Informed Engineering (CIE) and Secure-by-Design (SbD) principles, highlighting how these strategies can protect critical infrastructure and democratize access to secure energy, particularly for disadvantaged communities. The analysis underscores the challenges presented by the expansion of attack surfaces, interoperability requirements, and grid-edge analytics, offering innovative solutions that leverage advanced technologies and data-driven insights. Furthermore, this paper addresses the workforce development gap, emphasizing the necessity for public-private partnerships and vendor engagement in creating a skilled cybersecurity workforce. This paper has a dual focus on both the technological aspect of cybersecurity and the social dimension of equity within the context of sustainable energy development. It suggests a comprehensive examination of how these two critical elements interact and support the overarching goal of a sustainable energy future.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Power Over Ethernet Investigation Report

This report provides insight into collaboration between Savannah River National Laboratory’s (SRNL) Global Security Directorate, Augusta University (AU) and the Georgia Cyber Center (GCC) team with regards to device analysis, investigation, and R&D efforts. Most recently, the GCC/AU team approached SRNL to receive cybersecurity expertise in a joint effort to identify differences between a potentially questionable PoE injector recovered by Columbia County and an identical one purchased by the GCC. The questionable device was installed at a fire station operated in Columbia County, shown in the figure 1-1 below.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Robust Restoration From Cyber-Physical Attacks in Active Distribution Grids With Grid-Edge IBRs

The inverter-based resources (IBRs) have enabled the integration of renewable energy at the grid edge with enhanced control capabilities to support the reliable operation of power grids. Different control frameworks, such as hierarchical or distributed architecture, have been proposed with the expansion of cyber networks for real-time monitoring and control. This evolution of critical infrastructure into cyber-physical systems also brings more vulnerabilities for the broadened attack surfaces, and significantly increases the possibility of physical system failures or outages caused by cyberattacks. Among tremendous efforts in the defense-in-depth approach, it remains challenging to provide prompt detection and accurate location of attack entry points or paths. Therefore, the prevailing restoration framework may struggle to fully consider the cyber-physical interdependence, successfully isolate the compromised cyber and physical components, and safely recover the systems without the potential risks leading to secondary outages. This paper is motivated to develop a cyber-physical restoration framework for distribution grids to recover from cyber attacks by harnessing grid-edge IBRs. The framework is first built on the operational guidelines of IBRs considering the compromised cyber layer. Then, an ambiguity set is established to represent the uncertainty of attack scenarios and their possibility levels. Next, a distributionally robust optimization model is developed to provide the optimal load restoration strategy across all scenarios. The effectiveness of the proposed model is demonstrated through various use cases on the modified IEEE 13-node and 123-node test systems. Finally, simulation results demonstrate the effectiveness and advancement of developed post-attack restoration strategies.

Cybersecurity↗

Precursor Analysis Report: JBS Foods Ransomware Attack 2021

The JBS Foods 2021 Ransomware Attack Precursor Analysis Report leverages publicly available information about the JBS ransomware cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. In late May 2021, one of the world’s largest meat producers, JBS Foods, announced they had fallen victim to a worldwide ransomware attack, later found to be REvil ransomware. In the United States alone, JBS Foods accounts for nearly 25% of beef and roughly 20% of pork production. Adversaries initially launched a Distributed Denial of Service (DDoS) attack on the company’s Information Technology (IT) networks in Australia, but the attack impacted operations in Brazil, Canada, and the United States, as well. The attack caused plant operations in all four countries to shut down for at least one day. All nine of the U.S. meatpacking plants temporarily shut down because of the attack. The adversaries initially demanded a $\$$22 million ransom for the company’s data, but later negotiated the ransom down to $\$$11 million even after JBS Foods restored most of their systems. JBS Foods eventually paid the $\$$11 Million for reassurance from the adversaries that none of their customers’ data would be compromised in the future. Despite its short duration, the attack still caused large stocks of meat to spoil. The incident also underscored how adversaries can simultaneously compromise and move laterally through global subsidiaries of an organization. Researchers and analysts identified 22 unique techniques (in a sequence of 21 steps) utilized during the attack with a total of 361 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Sixteen of the identified techniques used during the JBS Foods cyber attack were precursors to the triggering event. Analysis identified 308 observables associated with these precursor techniques, 163 of which were assessed to have an increased likelihood of being perceived in the 75 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Precursor Analysis Report: SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003

The SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003 Precursor Analysis Report leverages publicly available information about Davis-Besse’s 2003 cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. On 25 January 2003, the SQL Slammer worm infected more than 90% of vulnerable hosts and crashed the internet in 10 to 15 minutes, making it one of the fastest spreading worms in history. SQL Slammer is a fileless, memory-resident worm that remotely exploits a stack-based buffer overflow vulnerability on local hosts to intensively scan and rapidly self-propagate across the internet. The worm infected approximately 300,000 unpatched hosts running Microsoft Structured Query Language (SQL) Server 2000 or Microsoft Desktop Engine (MSDE) 2000 with SQL Server Resolution Service. The SQL Slammer worm indirectly infected FirstEnergy’s Davis-Besse nuclear power plant by first infecting a consultant’s company network server and then propagating through an external misconfigured connection into Davis-Besse’s site network. The infection caused major network congestion, slow performance, data overloads, and the inability of local hosts to communicate with each other, which eventually caused a loss of availability and a loss of view when the Safety Parameter Display System (SPDS) and Plant Process Computer (PPC) crashed. At the time of the infection, the plant was already offline, the digital monitoring systems had redundant analog backups, and the plant control and safety functions were not affected, so there were no concerns of a safety breach. However, this incident resulted in many lessons learned and spawned important discussions about cybersecurity’s role in nuclear safety and electric power reliability regulation, policy, and guidance. Researchers and analysts identified 10 unique techniques utilized during the attack with a total of 640 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Eight of the identified techniques used during Davis-Besse cyber attack were precursors to the triggering event. Analysis identified 596 observables associated with these precursor techniques, 428 of which were assessed to have an increased likelihood of being perceived in the 331 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Precursor Analysis Report: Industroyer Targeting Ukraine Electric Power Transport Utility (Ukrenergo) 2016

The Industroyer Targeting Ukraine Electric Power Transport Utility (Ukrenergo) 2016 Precursor Analysis Report leverages publicly available information about the December 2016 cyber attack against the Ukrainian Ukrenergo electric transmission utility and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. Industroyer is a modular malware framework designed to deploy several Industrial Control System (ICS) protocol-specific attack payloads to disrupt electricity distribution. Adversaries deployed Industroyer within the target network on a Microsoft Windows endpoint capable of directly manipulating or communicating with ICS. Industroyer abuses the functionality of a targeted ICS’s legitimate control system to achieve its intended impact. Adversaries likely first gained access to Ukrenergo enterprise networks in early 2016 after a successful spearphishing campaign against organizations in the electric power sector. Adversaries then began capturing credentials beginning on 1 December 2016. This allowed access to the ICS environment at the Pivnichna electric transmission substation outside Kyiv through a device dual-homed on the Information Technology (IT) and ICS networks. Adversaries conducted discovery, targeting, and access to this device using information and previously captured credentials from compromised enterprise IT machines. Finally, the adversaries deployed and launched the Industroyer malware just before midnight on 17 December. By midnight, Ukrenergo had lost control of a targeted substation, resulting in electric power outages for over an hour in the city of Kyiv and the Kyiv region. Researchers and analysts identified 31 unique techniques (used in a sequence of 33 steps) utilized during the attack with a total of 846 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Twenty-nine of the identified techniques used during the Industroyer cyber attack were precursors to the triggering event. Analysis identified 548 observables associated with these precursor techniques, 353 of which were assessed to have an increased likelihood of being perceived in the 300 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Precursor Analysis Report: Ryuk Ransomware Attack on Universal Health Services 2020

The Ryuk Ransomware Attack on Universal Health Services (UHS) 2020 Precursor Analysis Report leverages publicly available information about the 2020 UHS cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. UHS manages over 400 hospitals and is one of the largest healthcare providers in the United States with 3.5 million patients each year. On 27 September 2020, UHS suffered a widespread ransomware attack that resulted in a denial of service to critical internet-dependent healthcare systems including workstations, phones, and data centers. Employees resorted to filing patient details with pen and paper, while other facilities had to redirect ambulances and urgent patients to other facilities for adequate care. Adversaries carried out the attack with Ryuk, a ransomware that encrypts data and generates a RyukReadMe.txt ransom note with the ransom fee to decrypt the data, varying from 15 Bitcoin (BTC) to 50 BTC, equivalent to roughly $\$$353,892 to $\$$964,617. UHS did not pay the ransom and was able to recover data through backups, but still reported an impact of $\$$67 million dollars in recovery costs. On 29 October, one month after the attack, UHS made an official statement that their systems had been restored and they were resuming normal operations. Researchers and analysts identified 18 unique techniques (used in a sequence of 19 steps) utilized during the attack with a total of 185 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Fourteen of the identified techniques used during the UHS cyber attack were precursors to the triggering event. Analysis identified 106 observables associated with these precursor techniques, 82 of which were assessed to have an increased likelihood of being perceived in the 30 days to two hours preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Precursor Analysis Report: Cyber Attack on Thyssenkrupp Blast Furnace 2014

The Cyber Attack on Thyssenkrupp Blast Furnace 2014 Precursor Analysis Report leverages publicly available information about the Thyssenkrupp Steel Mill cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. In December 2014, the German Government’s Federal Office for Information Security (BSI) released a report detailing a cyber attack on a German steel mill that occurred earlier that year, though exact dates and details of the attack were not revealed. While the report did not specify the name of the company, multiple sources identified the victim as one of Europe’s largest steel manufacturers, Thyssenkrupp AG. Further, Thyssenkrupp announced on 16 May of that year that Europe’s largest blast furnace, “Schwelgern 2,” located at its facility in Duisburg, Germany, would be offline for several weeks for repairs and upgrades, suggesting Schwelgern 2 was likely the target of the attack. The attack began in early 2014, when adversaries infiltrated the victim steel mill’s Information Technology (IT) network via a spearphishing campaign, then worked their way into the Operational Technology (OT) environment, where they executed software that caused denial of service, denial of control, and eventually a loss of control. This led to the blast furnace shutting down without proper safety procedures, resulting in catastrophic physical damage. No lives were lost in the incident, but ThyssenKrupp suffered $4 million in damage to the blast furnace and an additional $6 million in lost revenue. The adversaries required specialized knowledge and expertise in steel production, which enabled them to compromise a variety of internal systems and components across both IT and OT networks. The attack also demonstrated detailed knowledge of the industrial control systems (ICS) and production processes being used. This combination resulted in one of the earliest known publicly reported cybersecurity incidents resulting in physical damage to ICS equipment. Researchers and analysts identified 19 unique techniques (used in a sequence of 20 steps) utilized during the attack with a total of 454 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Fifteen of the identified techniques used during the Thyssenkrupp cyber attack were precursors to the triggering event. Analysis identified 369 observables associated with these precursor techniques, 316 of which were assessed to have an increased likelihood of being perceived in the 120 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗