Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cybersecurity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A Cybersecurity Testbed for Smart Buildings

Smart buildings are equipped with a plethora of cyber-physical systems, such as Internet of Things (IoT) devices and building automation systems. These devices, especially in commercial buildings, use legacy communications and hardware that were not designed with cybersecurity in mind. With increasing cyber threats in recent years, smart buildings have become an increasing target for attacks, but not enough published data are available from these incidents to study or replicate the scenarios to defend buildings. As part of the U.S. Department of Energy-funded project focusing on developing the Building Intelligence with Layered Defense Using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS) platform, we developed a cybersecurity test bed for smart buildings. This test bed includes a building simulation tool, virtual devices, emulated operational technology networks, and remote hardware-in-the-loop. Using this test bed, we performed different cyberattacks on the smart building model and collected both physical building data, to understand the impacts on the building, and network data, to aid in separating mechanical faults from cyberattacks during the detection. This test bed is a significant tool in protecting smart buildings from cyberattacks because they can aid in both cybersecurity analysis and the evaluation of cyberattack detection tools by testing the tools in a secure environment without impacting the building operations.

alfalfa↗

Cybersecurity Operational Research, Experimentation, Innovation, and Integration (COREII)

The Department of Energy’s Cybersecurity, Energy Security, and Emergency Response Office (CESER) has partnered with Idaho National Laboratory (INL) and energy companies to develop COREII. This research initiative aims to align with the national cybersecurity strategy, enhance the resilience of critical energy infrastructure, facilitate efforts to improve grid-enhancing technologies (GET) and major effects from other critical and emerging technologies, and to enable discovery of innovative solutions for emerging cybersecurity challenges

99 GENERAL AND MISCELLANEOUS↗

Idaho National Laboratory Energy Cybersecurity Programs Update

This brief presentation provides a status update on three Idaho National Laboratory energy cybersecurity programs of particular interest to NERC Reliability and Security Technical Committee annual in-person Security Groups summit. Public information on the following three programs is included: Cybersecurity for Operational Technology Environments (CyOTE™) program Cyber-Informed Engineering (CIE) Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, and associated high-level information on the Energy Software Bill of Materials POC, Executive Order 14017, and the Energy Cyber Sense Act

24 POWER TRANSMISSION AND DISTRIBUTION↗

Training a Quantum Annealing Based Restricted Boltzmann Machine on Cybersecurity Data

A restricted Boltzmann machine (RBM) is a generative model that could be used in effectively balancing a cybersecurity dataset because the synthetic data a RBM generates follows the probability distribution of the training data. RBM training can be performed using contrastive divergence (CD) and quantum annealing (QA). QA-based RBM training is fundamentally different from CD and requires samples from a quantum computer. We present a real-world application that uses a quantum computer. Specifically, we train a RBM using QA for cybersecurity applications. The D-Wave 2000Q has been used to implement QA. RBMs are trained on the ISCX data, which is a benchmark dataset for cybersecurity. For comparison, RBMs are also trained using CD. CD is a commonly used method for RBM training. Our analysis of the ISCX data shows that the dataset is imbalanced. We present two different schemes to balance the training dataset before feeding it to a classifier. The first scheme is based on the undersampling of benign instances. The imbalanced training dataset is divided into five sub-datasets that are trained separately. A majority voting is then performed to get the result. Our results show the majority vote increases the classification accuracy up from 90.24% to 95.68%, in the case of CD. For the case of QA, the classification accuracy increases from 74.14% to 80.04%. In the second scheme, a RBM is used to generate synthetic data to balance the training dataset. We show that both QA and CD-trained RBM can be used to generate useful synthetic data. Balanced training data is used to evaluate several classifiers. Among the classifiers investigated, K-Nearest Neighbor (KNN) and Neural Network (NN) perform better than other classifiers. They both show an accuracy of 93%. Our results show a proof-of-concept that a QA-based RBM can be trained on a 64-bit binary dataset. The illustrative example suggests the possibility to migrate many practical classification problems to QA-based techniques. Further, we show that synthetic data generated from a RBM can be used to balance the original dataset.

97 MATHEMATICS AND COMPUTING↗

FEMP Cybersecurity Arsenal

The FEMP Cyber Security Arsenal is a family of cyber security tools for the federal facility owners and operators. Using these tools, facility owners can evaluate their overall cybersecurity posture. These tools are web-based front-end tools. The tools are meant to help federal owners and operators to evaluate their overall cybersecurity posture. These tools are developed based on the NIST Cybersecurity framework, risk management framework, and DOE C2M2 architectures. Version 3 provides significant updates and features in ten areas

Ashley, Travis [Pacific Northwest National Laborat↗

Cybersecurity for Electric Vehicle Charging Infrastructure

As the U.S. electrifies the transportation sector, cyberattacks targeting vehicle charging could impact several critical infrastructure sectors including power systems, manufacturing, medical services, and agriculture. This is a growing area of concern as charging stations increase power delivery capabilities and must communicate to authorize charging, sequence the charging process, and manage load (grid operators, vehicles, OEM vendors, charging network operators, etc.). The research challenges are numerous and complicated because there are many end users, stakeholders, and software and equipment vendors interests involved. Poorly implemented electric vehicle supply equipment (EVSE), electric vehicle (EV), or grid operator communication systems could be a significant risk to EV adoption because the political, social, and financial impact of cyberattacks — or public perception of such — would ripple across the industry and produce lasting effects. Unfortunately, there is currently no comprehensive EVSE cybersecurity approach and limited best practices have been adopted by the EV/EVSE industry. There is an incomplete industry understanding of the attack surface, interconnected assets, and unsecured inter faces. Comprehensive cybersecurity recommendations founded on sound research are necessary to secure EV charging infrastructure. This project provided the power, security, and automotive industry with a strong technical basis for securing this infrastructure by developing threat models, determining technology gaps, and identifying or developing effective countermeasures. Specifically, the team created a cybersecurity threat model and performed a technical risk assessment of EVSE assets across multiple manufacturers and vendors, so that automotive, charging, and utility stakeholders could better protect customers, vehicles, and power systems in the face of new cyber threats.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AOI-2, A Novel Access Control Blockchain Paradigm for Cybersecure Sensor Infrastructure in Fossil Power Generation Systems

Fossil power generation systems are increasingly vulnerable to attack from both cybercriminals as well as internal threats. These vulnerabilities demand that emerging technologies such as blockchains be utilized to secure the data involved in the information flows within the Supervisory Control and Data Acquisition (SCADA) systems of the fossil power generation plants. The publicly accessible blockchain protocols, although secure, are visible to everyone. Even private blockchains currently are unable to support different levels of access to different participants, which is a critical requirement for the existing SCADA systems running the power plants. In light of the above, novel blockchain protocols that are specifically adapted to fossil power generation environments need to be developed in order to achieve the goal of cybersecure sensor networks. In this work, we address this question by creating a novel blockchain technology, namely smart private ledger, for cybersecure communication within the fossil power generation systems. A lab-scale sensor network consisting of strain and temperature sensors is constructed to develop the ledger. The technology has hierarchical access control which is compatible with the existing SCADA systems in fossil power plants. The sensor data is used with cryptographic digital signatures and secret sharing protocols within the nodes of the blockchain technology. The research results will lead to cybersecurity for machine-to-machine interactions, infrastructure for secure data logging for sensors, decentralized data storage, and second-layer technologies for high volume machine-to-machine interactions in the power plants. The work aims to largely address the concerns for the security of distributed sensor networks in such systems that can be compromised by insider threats and by cybercriminals. The research has led to the training of the next generation of engineers and scientists in the important areas of sensor engineering and blockchain technology.

01 COAL, LIGNITE, AND PEAT↗

Sample Cybersecurity Clauses for EV Charging Infrastructure Procurements

This is the final version of PNNL-34373, with sponsor updates. The proposed sample cybersecurity clauses for EVCI procurements are designed to assist in managing the risk of cyberattacks that may degrade the safety, security, and reliability of EVCI. The sample clauses are intended to be tailored and incorporated into procurement specifications for equipment and services related to the National EV Infrastructure Formula Program deployments. Widespread adoption of the sample cybersecurity procurement language will integrate cybersecurity throughout the life cycle of the infrastructure.

33 ADVANCED PROPULSION SYSTEMS↗

Countering Weapons of Mass Destruction (CWMD) Device Cybersecurity Characterization Process and Profile

Countering Weapons of Mass Destruction (CWMD) recognizes that threats in the cyberspace domain continue to grow, which requires CWMD devices and supporting systems to be both cybersecure (ability to protect or defend from cyber-attacks) and resilient (ability to maintain required capability in the face of adversity) to cyber threats. The CWMD cybersecurity characterization approach in this document supports existing cyber resilience activities within the Acquisition Lifecycle Framework. Similarly, this process supports existing Department of Homeland Security Cyber Resilience Test and Evaluation activities, which consist of iterative processes, starting at the initiation of system acquisition and continuing throughout the entire device and system life cycle. Cyber resilience is the ability of an information system to continue to operate while under attack, even if in a degraded or debilitated state, and to rapidly recover operational capabilities for essential functions after a successful attack. The goal of the security characterization task for CWMD is to support the development of a CBRN device-dependent profile that aligns with device network capabilities and maps to recommended security controls to create a characterization security profile impact levels. The impact levels for CWMD devices should be characterized as Low (L), Moderate (M), High (H) to align with the low, moderate, high control baselines. To estimate the impact levels, the device’s security-related attributes are translated into the security objectives: Confidentiality (C), Integrity (I), and Availability (A), known as the CIA triad. The potential impact for each device can be L, M, H, for devices that connect and transmit different types of data and may have different impact levels. National Institute of Standards and Technology Federal Information Processing Standards Publication 199 states, “the potential impact values assigned to the respective security objectives shall be the highest value from among those security categories that have been determined for each type of information resident on the information system.” As CWMD is determining the cybersecurity impact levels of CBRN devices based on network connections and data transfers, the impact levels are aligned with the associated attributes of network connections and communications. For example, if the device system is connected to a wireless network and transmits different data types based on the confidentiality of the data, the highest impact value for each security objective should represent the device’s CIA impact level. This document is intended to be used by test managers, test team, and program managers.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Countering Weapons of Mass Destruction (CWMD) Device Cybersecurity Characterization Process and Profile

Countering Weapons of Mass Destruction (CWMD) recognizes that threats in the cyberspace domain continue to grow, which requires CWMD devices and supporting systems to be both cybersecure (ability to protect or defend from cyber-attacks) and resilient (ability to maintain required capability in the face of adversity) to cyber threats. The CWMD cybersecurity characterization approach in this document supports existing cyber resilience activities within the Acquisition Lifecycle Framework. Similarly, this process supports existing Department of Homeland Security Cyber Resilience Test and Evaluation activities, which consist of iterative processes, starting at the initiation of system acquisition and continuing throughout the entire device and system life cycle. Cyber resilience is the ability of an information system to continue to operate while under attack, even if in a degraded or debilitated state,1 and to rapidly recover operational capabilities for essential functions after a successful attack.2 The goal of the security characterization task for CWMD is to support the development of a CBRN device-dependent profile that aligns with device network capabilities and maps to recommended security controls to create a characterization security profile impact levels. The impact levels for CWMD devices should be characterized as Low (L), Moderate (M), High (H) to align with the low, moderate, high control baselines. To estimate the impact levels, the device’s security-related attributes are translated into the security objectives: Confidentiality (C), Integrity (I), and Availability (A), known as the CIA triad. The potential impact for each device can be L, M, H, for devices that connect and transmit different types of data and may have different impact levels. National Institute of Standards and Technology Federal Information Processing Standards Publication 199 states, “the potential impact values assigned to the respective security objectives shall be the highest value from among those security categories that have been determined for each type of information resident on the information system.”3 As CWMD is determining the cybersecurity impact levels of CBRN devices based on network connections and data transfers, the impact levels are aligned with the associated attributes of network connections and communications. For example, if the device system is connected to a wireless network and transmits different data types based on the confidentiality of the data, the highest impact value for each security objective should represent the device’s CIA impact level. This document is intended to be used by test managers, test team, and program managers.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Talk Title: AI & Cybersecurity in ASEAN's Digital Future Venue: CyberForum: ASEAN Cyber Resilience Conference Hosted by: Indonesia Cyber Security Forum (ICSF) in coordination with US State Department's mission to ASEAN in Indonesia

The talk covers: * Quick orientation around AI * Quick review of relevant domains of Cybersecurity * The promise of AI in cybersecurity – applications * Discussion of the state of technology today, referencing Gartner Hype Cycle diagram * The peril of AI for cybersecurity – threats and risks * A roadmap for where to go from here, emphasizing a trained workforce, referencing published (ISC)^2 survey results

Benz, Zachary O.↗

Cybersecurity Baselines for Electric Distribution Systems and DER

The National Association of Regulatory Utility Commissioners (NARUC) has partnered with the Department of Energy (DOE) to develop a set of cybersecurity baselines for electric distribution systems and the distributed energy resources (DERs) that connect to them. Cybersecurity is an integral underpinning of power system resilience, and this initiative builds on work that states have undertaken over the last decade to mitigate cybersecurity risk across their critical infrastructures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing Solar Cybersecurity: Questions for States to Ask Electric Utilities

To help State Energy Officials and Public Utility Commissions engaging investor-and consumer-owned utilities and the solar industry in topical discussions about their cybersecurity practices and priorities in general, and for interconnected solar systems, specifically, this report outlines discussions prompts for these discussions. By using the questions in this tool states can explore aspects of utilities’ cybersecurity risk management programs that target solar devices, systems, and communication pathways. Such discussions help states identify cybersecurity gaps and assist in emergency response planning, as well as general risk awareness.

14 SOLAR ENERGY↗

State Legislative Options to Enhance Solar Cybersecurity

One of the mitigative solutions to solar cybersecurity risks is to proactively develop legislation which can facilitate, guide, or require actionable policy and program development . Legislation can reinforce the criticality of protecting energy infrastructure from cyber threats in several ways that can have long lasting impacts . This tool outlines relevant state cybersecurity legislation examples which can apply to solar cybersecurity and can serve as frameworks for future legislation by states seeking legislative options to help mitigate these risks

14 SOLAR ENERGY↗

Cybersecurity Methods for Grid-Connected Power Electronics

The present work shows a secure-by-design process, defense-in-depth method, and security techniques for a secure distributed energy resource. The distributed energy resource is a cybersecure, solar inverter and battery energy storage system prototype, collectively called the Cybersecure Power Router. Consideration is given to the use of the Smart Green Power Node for a foundation of the present work. Metrics for controller security are investigated to evaluate firmware security techniques. The prototype's ability to mitigate, respond to, and recover from firmware integrity degradation is examined. The prototype shows many working security techniques within the context of a grid-connected, distributed energy resource. Further work is expected in the Cybersecure Power Router project. Consideration is also provided for the migration of the present research and the Smart Green Power Node to realize a pre-production prototype.

Moquin, Stephen Joe↗

Cybersecurity Education, Training, and WFD

Availability of skilled workforce in sufficient number is one of the most often cited barriers to improving cybersecurity. INL's research has determined that this is not a cybersecurity problem but rather a strategic business imperative; in response INL created the Cyber Competency Health and Maturity Progression Model (Cyber-CHAMP) to help organizations learn the realities of their cyber workforce and their development needs. The presentation starts with an overview of Cyber-CHAMP as a unifying theme for workforce development and then provides brief introductions to selected DHS (ICS cybersecurity hands-on training), DOE (CyberStrike, OT Defender Fellowship, Liberty Eclipse), and INL (Cybercore Summer Camp, University Collaboration Laboratory) programs. Cyber-Informed Engineering discussion concludes the presentation, with an update on activities conducted by the CIE Education Working Group to further the second pillar of the National CIE Strategy, Education.

42 ENGINEERING↗

Distributed Energy Resources Cybersecurity Framework: Applying the NIST Risk Management Process

In an effort to strengthen the cybersecurity posture for federal agencies and reduce the time and complexities of following the Risk Management Framework (RMF) six-step process, the National Renewable Energy Laboratory has dedicated research into expanding the existing Distributed Energy Resources Cybersecurity Framework to provide functionality that aids in the RMF steps. Users will have the opportunity to learn, document, and review the framework, saving time and resources. Existing functionality within the web application will continue to be available with added features for usability.

14 SOLAR ENERGY↗

Clean Energy Cybersecurity Accelerator Cohort 1: Authentication and Authorization

In the 2023 National Cybersecurity Strategy, the Biden-Harris Administration defines the need for a "defensible, resilient digital ecosystem where it is costlier to attack systems than defend them." The strategy cites the Clean Energy Cybersecurity Accelerator (CECA) as an exemplary effort to bolster the security and resilience of clean energy generation. These efforts help "secure the clean energy grid of the future and [generate] security best practices that extend to other critical infrastructure sectors" and promise broad and far-reaching impacts to bridge the capabilities of private industry and the needs of energy production. Cohort 1 of CECA launched in the fall of 2022 with a focus on solutions that provide strong authentication and authorization for industrial control systems to mitigate attacks on the energy grid. Authentication and authorization verify that the identity (authentication) and permissions (authorization) of a user or device are aligned with their assigned roles. Weaknesses in either can have serious repercussions. To assess the strength of Cohort 1's solutions, CECA devised threat scenarios grounded in historical precedents: the CECA team reviewed exploits from real-world case studies of state-sponsored actors to match the assessment's attack paths and targets. Cohort 1 results provided the energy industry, product vendors, and related agencies valuable insights into the efficacy and applicability of solutions in common system configurations under realistic threat scenarios. The results of the assessment highlight points for interrogation and improvement in subsequent technology iterations. CECA's evaluations are part of an ongoing conversation and collaboration to bolster U.S. cyber resilience against adversaries today and in the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗